• 제목/요약/키워드: acceleration amplification

검색결과 160건 처리시간 0.02초

Seismic response evaluation of 154 kV transformer porcelain bushing by shaking table tests

  • Chun, Nakhyun;Jeon, Bubgyu;Kim, Sungwan;Chang, Sungjin;Son, Suwon
    • Structural Engineering and Mechanics
    • /
    • 제84권2호
    • /
    • pp.155-165
    • /
    • 2022
  • The use of electricity and communication between electronic devices is increasing daily, which makes the stability of electrical power supply vital. Since the 1990s, large earthquakes have occurred frequently causing considerable direct damage to electrical power facilities as well as secondary damage, such as difficulty in restoring functions due to the interruption of electric power supply. Therefore, it is very important to establish measures to protect electrical power facilities, such as transformers and switchboards, from earthquakes. In this study, a 154 kV transformer whose service life had expired was installed on the base fabricated by simulating the field conditions and conducting the shaking table tests. The dynamic characteristics and seismic behavior of the 154 kV transformer were analyzed through the resonance frequency search test and seismic simulation test that considers the front, rear, left, and right directions. Since the purpose of this study is to analyze the acceleration amplification in the bushing due to the acceleration amplification, the experimental results were analyzed focusing on the acceleration response and the converted acceleration amplification ratio rather than the failure due to the displacement response of the transformer. The seismic force amplification at the transformer bushing was evaluated by simulating the characteristics of electrical power facilities in South Korea, and compared with the IEC TS 61463 acceleration amplification factor. Finally, the amplification factor at zero period acceleration (ZPA) modified for each return period was summarized. The results of this study can be used as data to define the amplification factor at ZPA of the transformer bushing, simulating the characteristics of electrical power facilities in Korea.

전력설비의 내진설계를 위한 변전소 구조형식에 따른 가속도 증폭계수의 평가 (Evaluation of Acceleration Amplification Factors Based on the Structural Type of Substation for the Seismic Design of Power Facilities)

  • 박성제;전낙현;황경민;문지호;송종걸
    • 한국전산구조공학회논문집
    • /
    • 제33권3호
    • /
    • pp.159-169
    • /
    • 2020
  • 변전소 구조물 내부에 설치되는 전력설비의 내진설계 시 사용되는 변수인 가속도 증폭계수는 미국, 일본과 국내의 변전소 내진설계기준에서 제시되어 있다. 국내 설계기준에 제시된 가속도 증폭계수는 미국, 일본의 설계기준에서 제시된 계수와는 달리 변전소 구조물의 층수가 4층 이상일 경우에는 동적해석을 수행하여 가속도 증폭계수를 구하게 되어 있다. 국내의 변전소 구조물은 대부분 층수가 4~5층이므로 기존의 가속도 증폭계수는 실제 변전소 구조물에 적용하기에 미흡한 상황이다. 국내 변전소 구조물 형식에 적합한 가속도 증폭계수를 제시하기 위하여 대표적인 7가지 구조형식의 변전소 구조물에 대하여 가속도 증폭계수를 평가하였다. 가속도증폭계수는 변전소 구조물에 대하여 원거리 지진과 근거리 지진을 사용하여 내부-구조물 응답스펙트럼을 작성하여 이로부터 평가하였다. 미국, 일본 전력설비 내진설계 기준에 따른 각각의 가속도 증폭계수 αJ, αA는 근거리 및 원거리 지진을 사용한 동적 해석으로 구한 가속도 증폭계수에 비하여 다소 과대평가하는 경향이 있다.

다양한 다층 지반모형에 대한 지진동 증폭 (Earthquake Amplification for Various Multi-Layer Ground Models)

  • 정수근;김호연;김대현
    • 지질공학
    • /
    • 제33권2호
    • /
    • pp.293-305
    • /
    • 2023
  • 지진이 발생할 때 대한 지진동 증폭 현상을 확인하기 위해 1g 진동대와 연성토조(Laminar Shear Box, LSB)를 이용하여 모형지반을 조성하였고, 3가지 모델에 대하여 지진동 증폭현상에 대하여 확인하였다. 3가지의 모형지반을 선정하였으며 모든 모형지반에서 조밀한 층과 느슨한 층으로 나누었고, 지반모형의 경우는 다층 수평지반, 다층 제방지반, 다층 분지지반모형으로 선정하였다. 각 지반모형을 제작하며 가속도계 매설을 진행하였으며, 인공지진파, Sinesweep파와 Sine 10 Hz의 지진파를 통하여 증폭현상을 확인하였다. 최대지반가속도(Peak ground acclelration, PGA)와 응답스펙트럼 가속도(Spectrum acceleration, SA)를 통해 지진동 증폭현상을 확인하였다. 수평 다층지반에서 조밀한 지반을 통과 후 느슨한 지반에서 가속도 증폭이 조밀한 지반에 비해 크게 발생하는 것을 확인할 수 있었으며, 다른 두 모형지반에서는 층의 경계면을 통과 후 점차 중심부에서 가속도 증폭이 더 크게 발생하는 것을 확인할 수 있었다.

Acceleration amplification characteristics of embankment reinforced with rubble mound

  • Jung-Won Yun;Jin-Tae Han;Jae-Kwang Ahn
    • Geomechanics and Engineering
    • /
    • 제36권2호
    • /
    • pp.157-166
    • /
    • 2024
  • Generally, the rubble mound installed on the slope embankment of the open-type wharf is designed based on the impact of wave force, with no consideration for the impact of seismic force. Therefore, in this study, dynamic centrifuge model test results were analyzed to examine the acceleration amplification of embankment reinforced with rubble mound under seismic conditions. The experimental results show that when rubble mounds were installed on the ground surface of the embankment, acceleration response of embankment decreased by approximately 22%, and imbalance in ground settlement decreased significantly from eight to two times. Furthermore, based on the experimental results, one-dimensional site response (1DSR) analyses were conducted. The analysis results indicated that reinforcing the embankment with rubble mound can decrease the peak ground acceleration (PGA) and short period response (below 0.6 seconds) of the ground surface by approximately 28%. However, no significant impact on the long period response (above 0.6 seconds) was observed. Additionally, in ground with lower relative density, a significant decrease in response and wide range of reduced periods were observed. Considering that the reduced short period range corresponds to the critical periods in the design response spectrum, reinforcing the loose ground with rubble mound can effectively decrease the acceleration response of the ground surface.

Evaluating the effective spectral seismic amplification factor on a probabilistic basis

  • Makarios, Triantafyllos K.
    • Structural Engineering and Mechanics
    • /
    • 제42권1호
    • /
    • pp.121-129
    • /
    • 2012
  • All contemporary seismic Codes have adopted smooth design acceleration response spectra, which have derived by statistical analysis of many elastic response spectra of natural accelerograms. The above smooth design spectra are characterized by two main branches, an horizontal branch that is 2.5 times higher than the peak ground acceleration, and a declining parabolic branch. According to Eurocode EN/1998, the period range of the horizontal, flat branch is extended from 0.1 s, for rock soils, up to 0.8 s for softer ones. However, from many natural recorded accelerograms of important earthquakes, the real spectral amplification factor appears to be much higher than 2.5 and this means that the spectrum leads to an unsafe seismic design of the structures. This point is an issue open to question and it is the object of the present study. In the present paper, the spectral amplification factor of the smooth design acceleration spectra is re-calculated on the grounds of a known "reliability index" for a desired probability of exceedance. As a pilot scheme, the seismic area of Greece is chosen, as it is the most seismically hazardous area in Europe. The accelerograms of the 82 most important earthquakes, which have occurred in Greece during the last 38 years, are used. The soil categories are taken into account according to EN/1998. The results that have been concluded from these data are compared with the results obtained from other strong earthquakes reported in the World literature.

Prediction of dynamic behavior of full-scale slope based on the reduced scale 1 g shaking table test

  • Jin, Yong;Kim, Daehyeon;Jeong, Sugeun;Park, Kyungho
    • Geomechanics and Engineering
    • /
    • 제31권4호
    • /
    • pp.423-437
    • /
    • 2022
  • The objective of the study is to evaluate the feasibility of the dynamic behavior of slope through both 1 g shaking table test and numerical analysis. Accelerometers were installed in the slope model with different types of seismic waves. The numerical analysis (ABAQUS and DEEPSOIL) was used to simulate 1 g shaking table test at infinite boundary. Similar Acceleration-time history, Spectral acceleration (SA) and Spectral acceleration amplification factor (Fa) were obtained, which verified the feasibility of modeling using ABAQUS and DEEPSOIL under the same size. The influence of the size (1, 2, 5, 10 and 20 times larger than that used in the 1 g shaking table test) of the model used in the numerical analysis were extensively investigated. According to the similitude law, ABAQUS was used to analyze the dynamic behavior of large-scale slope model. The 5% Damping Spectral acceleration (SA) and Spectral acceleration amplification factor (Fa) at the same proportional positions were compared. Based on the comparison of numerical analyses and 1 g shaking table tests, it was found that the 1 g shaking table test result can be utilized to predict the dynamic behavior of the real scale slope through numerical analysis.

Occurrence mechanism of recent large earthquake ground motions at nuclear power plant sites in Japan under soil-structure interaction

  • Kamagata, Shuichi;Takeqaki, Izuru
    • Earthquakes and Structures
    • /
    • 제4권5호
    • /
    • pp.557-585
    • /
    • 2013
  • The recent huge earthquake ground motion records in Japan result in the reconsideration of seismic design forces for nuclear power stations from the view point of seismological research. In addition, the seismic design force should be defined also from the view point of structural engineering. In this paper it is shown that one of the occurrence mechanisms of such large acceleration in recent seismic records (recorded in or near massive structures and not free-field ground motions) is due to the interaction between a massive building and its surrounding soil which induces amplification of local mode in the surface soil. Furthermore on-site investigation after earthquakes in the nuclear power stations reveals some damages of soil around the building (cracks, settlement and sand boiling). The influence of plastic behavior of soil is investigated in the context of interaction between the structure and the surrounding soil. Moreover the amplification property of the surface soil is investigated from the seismic records of the Suruga-gulf earthquake in 2009 and the 2011 off the Pacific coast of Tohoku earthquake in 2011. Two methods are introduced for the analysis of the non-stationary process of ground motions. It is shown that the non-stationary Fourier spectra can detect the temporal change of frequency contents of ground motions and the displacement profile integrated from its acceleration profile is useful to evaluate the seismic behavior of the building and the surrounding soil.

비구조요소의 내진설계를 위한 등가정적 층가속도 평가 (Evaluation of Equivalent-Static Floor Acceleration for Seismic Design of Non-Structural Elements)

  • 전수찬;이철호;배창준;김성용
    • 대한건축학회논문집:구조계
    • /
    • 제36권3호
    • /
    • pp.121-128
    • /
    • 2020
  • In this paper, the ASCE 7 equivalent static approach for seismic design of non-structural elements is critically evaluated based on the measured floor acceleration data, theory of structural dynamics, and linear/nonlinear dynamic analysis of three-dimensional building models. The analysis of this study on the up-to-date database of the instrumented buildings in California clearly reveals that the measured database does not well corroborate the magnitude and the profile of the floor acceleration as proposed by ASCE 7. The basic flaws in the equivalent static approach are illustrated using elementary structural dynamics. Based on the linear and nonlinear dynamic analyses of three-dimensional case study buildings, it is shown that the magnitude and distribution of the PFA (peak floor acceleration) can significantly be affected by the supporting structural characteristics such as fundamental period, higher modes, structural nonlinearity, and torsional irregularity. In general, the equivalent static approach yields more conservative acceleration demand as building period becomes longer, and the PFA distribution in long-period buildings tend to become constant along the building height due to the higher mode effect. Structural nonlinearity was generally shown to reduce floor acceleration because of its period-lengthening effect. Torsional floor amplification as high as 250% was observed in the building model of significant torsional irregularity, indicating the need for inclusion of the torsional amplification to the equivalent static approach when building torsion is severe. All these results lead to the conclusion that, if permitted, dynamic methods which can account for supporting structural characteristics, should be preferred for rational seismic design of non-structural elements.

지진계측 기록을 이용한 저수지 지진응답가속도 증폭 특성 분석 (Analysis of Reservoir Seismic Response Acceleration Amplification Characteristics Using Seismic Measurements Data)

  • 이무재;김용성;타망비벡;이승주;이길용;허준
    • 한국지반신소재학회논문집
    • /
    • 제19권4호
    • /
    • pp.51-63
    • /
    • 2020
  • 본 연구에서는 지진가속도 계측기의 계측 데이터를 사용하여 저수지의 동적해석방법에 대한 모형 검정 및 저수지 높이에 따른 지진가속도 증폭 특성을 분석하였다. 모형을 검정하기 위해 댐 기초의 계측 데이터를 입력 데이터로 사용하였고 해석 결과를 댐 상부의 계측 데이터와 비교한 결과 수치해석을 이용해 출력된 지진파와 계측 지진파의 최댓값과 그 파형이 비슷하게 나타났고 지진가속도 증폭 특성의 경우 지진가속도 증폭비는 저수지의 높이와 지진의 크기에 비례하는 것으로 나타났다. 본 연구를 통해 저수지에 설치된 가속도계에서 얻은 계측 데이터를 활용하여 반복 탄소성 구성식을 이용한 동적해석방법은 지진파 특성 분석이 적절하게 수행될 수 있는 기법임을 확인하였고 향후 이러한 기법을 적용해 저수지의 지진가속도 계측기의 활용도를 제고할 수 있을 것으로 판단된다.

비구조요소의 내진 설계를 위한 기존 층응답스펙트럼의 평가 (A Study on Evaluation of Floor Response Spectrum for Seismic Design of Non-Structural Components)

  • 최경석;이원호;양원직;김형준
    • 한국지진공학회논문집
    • /
    • 제17권6호
    • /
    • pp.279-291
    • /
    • 2013
  • The seismic damage of non-structural components, such as communication facilities, causes direct economic losses as well as indirect losses which result from social chaos occurring with downtime of communication and financial management network systems. The current Korean seismic code, KBC2009, prescribes the design criteria and requirements of non-structural components based on their elastic response. However, it is difficult for KBC to reflect the dynamic characteristics of structures where non-structural components exist. In this study, both linear and nonlinear time history analyses of structures with various analysis parameters were carried out and floor acceleration spectra obtained from analyses were compared with both ground acceleration spectra used for input records of the analyses and the design floor acceleration spectrum proposed by National Radio Research Agency. Also, this study investigates to find out the influence of structural dynamic characteristics on the floor acceleration spectra. The analysis results show that the acceleration amplification is observed due to the resonance phenomenon and such amplification increases with the increase of building heights and with the decrease of structure's energy dissipation capacities.