• 제목/요약/키워드: accelerated corrosion

검색결과 451건 처리시간 0.021초

배관감육관리에 활용되는 CHECWORKS 프로그램의 열수력해석 방법론 검증에 관한 연구 (A Study on the Verification of Network Flow Analysis Methodology of CHECWORKS Program used in Pipe Wall Thinning Management)

  • 서혁기;황경모
    • Corrosion Science and Technology
    • /
    • 제12권2호
    • /
    • pp.79-84
    • /
    • 2013
  • In general, pipelines at nuclear power plants are affected by various types of degradation mechanisms and may be ruptured after gradually thinning. FAC (Flow-Accelerated Corrosion) is typical aging mechanism affecting the secondary side piping system. In Korea nuclear power plants, CHECWORKS program have been used for management of wall thinning damages. However, sometimes, CHECWORKS program shows wrong results at the stage of NFA (Network Flow Analysis) in case of complex pipelines. This paper describes the calculation results of pressure drop in a complex pipeline and single line by using the CHECWORKS program and the analysis results are compared with those of engineering calculation results including errors between them.

원전 2차계통의 수화학 변화가 배관감육에 미치는 영향 분석 (Analysis of Pipe Wall-thinning Caused by Water Chemistry Change in Secondary System of Nuclear Power Plant)

  • 윤훈;황경모;문승재
    • Corrosion Science and Technology
    • /
    • 제14권6호
    • /
    • pp.325-330
    • /
    • 2015
  • Pipe wall-thinning by flow-accelerated corrosion (FAC) is a significant and costly damage of secondary system piping in nuclear power plants (NPPs). All NPPs have their management programs to ensure pipe integrity from wall-thinning. This study analyzed the pipe wall-thinning caused by changing the amine, which is used for adjusting the water chemistry in the secondary system of NPPs. The pH change was analyzed according to the addition of amine. Then, the wear rate calculated in two different amines was compared at the steam cycle in NPPs. As a result, increasing the pH at operating temperature (Hot pH) can reduce the rate of FAC damage significantly. Wall-thinning is affected by amine characteristics depending on temperature and quality of water.

철근보강 지오폴리머 콘크리트 시험체에 전기화학적 방식기법 적용과 방식성능 분석 (Electro Chemical Protection Property for Reinforced Geo-Polymer Specimen Under Ocean Environment and Accelerated Test)

  • 박동천;조규환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.178-179
    • /
    • 2014
  • Corrosion is very serious problem in RC structure under ocean environment. There is no enough experiment information using the reinforced geo polymer concrete applied by electo chemical protection system. Three condition, such as tidal zone, submerged zone and crack were simulated to geo polymer specimen. Corrosion rate and natural electrode potential were measured through accelerated test. Anti corrosion property of geo polymer was better than OPC regardless of specimen condition and applied time.

  • PDF

Effect of Aluminum and Silicon on Atmospheric Corrosion of Low-alloying Steel under Containing NaHSO3 Wet/dry Environment

  • Chen Xinhua;Dong Junhua;Han Enhou;Ke Wei
    • Corrosion Science and Technology
    • /
    • 제7권6호
    • /
    • pp.315-318
    • /
    • 2008
  • The atmospheric corrosion performance of Al-alloying, Si-alloying and Al-Si-alloying steel were studied by wet/dry cyclic corrosion tests (CCT) at $30^{\circ}C$ and 60% relative humidity (RH). The corrosion electrolyte used for CCT was 0.052 wt% $NaHSO_{3}$ (pH~4) solution. The result of gravimetry demonstrated that Al-Si-bearing steels showed lower corrosion resistance than other rusted steels. But the rusted 0.7%Si-alloying steel showed a better corrosion resistance than rusted mild steel. Polarization curves demonstrated that Al-/Si-alloying and Al-Si-alloying improved the rest potential of steel at the initial stage; and accelerated the cathodic reduction and anodic dissolution after a rust layer formed on the surfaces of steels. XRD results showed that Al-Si-alloying decreased the volume fraction of $Fe_{3}O_{4}$ and $\alpha-FeOOH$. The recycle of acid accelerated the corrosion of steel at the initial stage. After the rust layer formed on the steel, the leak of rust destabilized the rust layer due to the dissolution of compound containing Al (such as $FeAl_{2}O_{4}$, $(Fe,\;Si)_{2}(Fe,\;Al)O_{4}$). Al-Si-alloying is hence not suitable for improving the anti-corrosion resistance of steel in industrial atmosphere.

철근콘크리트구조물의 철근부식에 대한 비파괴 측정과 부식에 따른 균열거동 (A Study of Non-destructive Measurement on the Reinforced Concrete Structure Damaged by Reinforcing Steel Corrosion)

  • 김성운;정한중;김창환;임선택
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1991년도 가을 학술발표회 논문집
    • /
    • pp.80-85
    • /
    • 1991
  • This experimental study was performed to derive the relationship between the measured values(corrosion potential) and the actual amount of corrosion products(reinforcing steel weight loss rate). Also the growth of crack due to the steel corrosion was oberved. First, the reinforcing steel of R/C specimen was corroded with chloride penetration and accelerated galvanostatic corrosion method. And then, the corrosion potential of reinforcing steel was measured with nondestructive tester.

  • PDF

플라이애시 혼합 콘크리트의 철근 부식 저항성능 평가 (Corrosion-Resisting Performance Evaluation of Concrete Mixed with Fly-Ash)

  • 박상순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권1호
    • /
    • pp.117-125
    • /
    • 2017
  • 플라이애시가 시멘트의 대체재로 사용되면서 플라이애시는 콘크리트의 특성변화에 중요한 역할을 하고 있다. 본 연구에서는 보통 콘크리트와 플라이애시를 혼입한 콘크리트의 철근부식에 대한 저항성을 평가하였다. 부식속도가 가장 빠른 간만대 환경을 모사한 최적 건습반복시험방법을 찾고 해양환경폭로시험장의 간만대에 장기간 노출된 시편의 철근부식모니터링 시험결과와의 비교를 통해 FA 혼입에 따른 OPC 대비 부식 지연비를 도출하였다. 반전지전위법에 의한 부식 모니터링 결과 인공해수에 3일간 침지 후 4일간 건조의 반복 조건보다는 염수를 시편 상부에 침지시켜 염수 및 산소의 공급이 계속되는 염수 ponding 시험법이 부식을 촉진시키는 것으로 나타났다. 모든 시험법에서 OPC에 비해 FA의 철근 부식이 지연되었다. FA의 철근부식 지연비율은 재령이 증가할수록 증가하였으며 OPC 대비 최대 27%까지 철근부식이 지연되었다. 그 결과 플라이애시 콘크리트는 재령이 증가할수록 철근부식 저항성능이 향상됨을 알 수 있었다.

CoCrMo 자성박막의 부식에 관한 연구 (A Study on Corrosion CoCrMo Magnetic Thin Films)

  • 남인탁;홍양기
    • 한국자기학회지
    • /
    • 제3권3호
    • /
    • pp.221-228
    • /
    • 1993
  • 고밀도기록용 박막재료로서의 충족조건은 높은 보자력, 높은 포화자화, 생산성, 그리고 화학적 안정성으로써 수직자기기록매체 CoCrMo 자성박막을 RF 스퍼터링 방법으로 제조한 후, 부식 특성을 전기화학적 측정, acceleration corrosion test 및 부식후 박막의 표면분석을 통하여 조사 하였다. CoCrMo 박막의 부식특성은 스퍼터링 조건에 따라서 다르게 나타났으며, Mo의 함량이 증가 할수록 내식성은 향상되었다. 전기화학부식실험 결과 박막의 Mo 함량이 증가할수록 뚜렷한 활성- 불활성 전이를 나타내었으며 부동태전류밀도의 감소를 나타내었다. Accelerated corrosion test에 서 CoCrMo 박막의 부식은 전기화학반응에 의하여 일어났으며 Mo첨가에 따라 부식이 일어난 곳의 수는 감소하였다. AES분석결과 부식 장소에는 많은 양의 $Cl_{-}$ 이온이 존재하였고, Cr의 고갈이 부식의 원인이었다.

  • PDF

인공 해수에 침적한 모르터 중의 철근 부식에 대한 연구 (A study on Corrosion of Steel in Mortar under the Environment of Artificial Seawater)

  • 문한영;김성수;류재석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 봄 학술발표회 논문집
    • /
    • pp.73-78
    • /
    • 1993
  • This study was performed for the purposes of estimating steel corrosion of concrete structures under the environment of seawater. The corrosion of steel was accelerated in artificial seawater with seven kinds of specimen which was embedded in mortar. By measuring choride content in mortar, half cell potential and corrosion area ratio, the degree of steel corrosion can be assumed.

  • PDF

촉진부식실험을 이용한 OPC 및 슬래그 콘크리트의 부식-부착강도 평가 (Corrosion-bond Strength Evaluation in OPC and Slag Concrete using Accelerated Corrosion Test)

  • 오상진;이현우;권성준
    • 한국건설순환자원학회논문집
    • /
    • 제12권1호
    • /
    • pp.1-7
    • /
    • 2024
  • 다공성인 콘크리트에서는 외부의 수분 및 염화물 유입이 발생하며, 이는 매립된 철근의 부식을 야기한다. 본 연구에서는 촉진부식실험(ICM: Impressed Current Method)를 이용하여 10 V의 전압을 인가하였으며, 이에 따라 10 % 수준까지 부식량을 조절하였다. 부식량은 부식전류량 누계와 선형적인 관계가 도출되었으며, 균열의 영향으로 부식 유도 시간에 따라 2차 함수의 형태로 증가하였다. 부착응력에 대해서는 OPC 콘크리트에 대해서는 부식량 3.0 % 이후 급격한 부착응력의 감소가 발생하였다. 또한 치환률 30 %의 슬래그 콘크리트에서는 일반 콘크리트에 비하여 51.4~71.6 %의 낮은 부식량을 나타내었으며 5일간의 촉진실험에도 일정 수준의 부착강도를 유지하였다.

써모스타트 하우징의 침전물 생성에 관한 고장분석 및 가속시험법 개발 (Failure Analysis on Scale Formation of Thermostat Housing and Development of Accelerated Test Methodology)

  • 조인희;형신종;최길영;원종일
    • 공업화학
    • /
    • 제20권2호
    • /
    • pp.177-185
    • /
    • 2009
  • 자동차용 써모스타트 하우징 피팅부상의 침전물(스케일)에 대한 고장분석을 실시하였다. 에너지분산형분석기와 전자현미분석기를 이용하여 침전물이 부동액의 주요 첨가제 성분임을 확인하였다. 자세한 유기성분 분석을 위해 열분해 기체크로마토그래피/질량분석을 수행한 결과, 침전물의 주성분이 벤조산이며, 소량의 아세토페논, 벤젠 및 페닐계 화합물 등으로 이루어져 있음을 확인하였다. 더불어 침전물 생성 원인은 알루미늄 하우징과 고무호스 사이에 존재하는 틈새 공간에 부동액 성분의 침전에 따른 틈새부식에 기인한 것으로 판단된다. 이런 결과를 바탕으로 하여 써모스타트 하우징상의 침전물 생성과 틈새부식을 재현할 수 있는 가속시험기법을 개발하였다. 가속인자(온도, 습도)를 변화시키면서 실제 가동조건을 묘사하였다. 가속시험에서 얻은 침전물을 성분 분석을 통해 완벽히 재현되었음을 확인하였다.