무가압함침법으로 제조된 입자강화 금속복합재료의 마모특성 (Wear Characteristics of Particulate Reinforced Metal Matrix Composites Fabricated by a Pressureless Metal Infiltration Process)

  • 김재동;정순억;김형진
    • 한국해양공학회지
    • /
    • 제17권1호
    • /
    • pp.55-60
    • /
    • 2003
  • The effect of size and volume fraction of ceramic particles, with sliding velocity on the wear properties were investigated for the metal matrix composites fabricated by the pressureless infiltration process. The metal matrix composites exhibited about 5.5 - 6 times the wear resistance compared with AC8A alloy at high sliding velocity, and by increasing the particle size and decreasing the volume fraction, the wear resistance was improved. The wear resistance of metal matrix composites and AC8A alloy exhibited different aspects. Wear loss of AC8A alloy increased with sliding velocity, linearly : whereas, metal matrix composites indicated more wear loss than AC8A alloy at the slow velocity region. However, a transition point of wear loss was found at the middle velocity region, which shows the minimum wear loss. Further, wear loss at the high velocity region exhibited nearly the same value as the slow velocity region. In terms of wear mechanism, the metal matrix composites generally exhibited abrasive wear at slow to high sliding velocity; however, AC8A alloy showed abrasive wear at low sliding velocity and adhesive and melt wear at high sliding velocity.

무가압함침법으로 제조된 입자강화 금속복합재료의 마모특성 (Wear Characteristics of Particulate Reinforced Metal Matrix Composites Fabricated by Pressureless Metal Infiltration Process)

  • 김재동;정순억;김형진
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.379-384
    • /
    • 2002
  • The effect of size and volume fraction of ceramic particles with sliding velocity on the wear properties were investigated for the metal matrix composites fabricated by pressureless infiltration process. The particulate metal matrix composites exhibited about 5.5 - 6 times of excellent wear resistance compared with AC8A alloy at high sliding velocity, and as increasing the particle size and decreasing the volume fraction the wear resistance was improved. The wear resistance of metal matrix composites and AC8A alloy exhibited different aspects. Wear loss of AC8A alloy increased with sliding velocity linearly. whereas metal matrix composites indicated more wear loss than AC8A alloy at slow velocity region, however a transition point of wear loss was found at middle velocity region which show the minimum wear loss, and wear loss at high velocity region exhibited nearly same value with slow velocity region. In terms of wear mechanism, the metal matrix composites exhibited the abrasive wear at slow to high sliding velocity generally, however AC8A alloy showed abrasive wear at low sliding velocity and adhesive and melt wear at high sliding velocity.

  • PDF

무가압함침법으로 제조한 SiCp/AC8A 복합재료의 기계적 성질 (Mechanical Properties of SiCp/AC8A Composites Fabricated by Pressureless Metal Infiltration Process)

  • 김재동;고성위;김형진
    • Composites Research
    • /
    • 제15권3호
    • /
    • pp.1-10
    • /
    • 2002
  • 무가압함침법에 의해 제조된 SiCp/AC8A복합재료에 대하여 SiC 입자 크기와 부가적인 Mg의 첨가가 복합재료의 기계적 성질과 마모특성에 미치는 영향을 조사하였다. SiCp/AC8A복합재료의 경도와 굽힘강도는 입자의 크기가 작아짐에 따라 증가하였다. Mg 첨가량이 증가함에 따라 SiCP/AC8A복합재료의 경도는 경질의 반응생성물에 의해 상승하였으나 굽힘강도는 석출물의 조대화와 기공율의 증대에 의해 저하하였다. SiCp/AC8A복합재료는 AC8A 기지재에 비하여 고속의 마찰속도에서 6배의 내마모성을 나타냈으며 강화입자의 크기가 작아짐에 따라 내마모성은 향상되는 것으로 나타났다. 마모기구에 있어서 SiCp/AC8A복합재료는 마찰속도에 관계없이 연삭마모를 나타냈으나 AC8A 기지재는 마찰속도가 고속화됨에 따라 응착 및 용융마모의 마모면을 나타냈다.

$TiS_2$ Composite/SPE/Li Cell의 충방전에 따른 AC 임피던스의 변화 (Variation of AC Impedance of the $TiS_2$ Composite/SPE/Li Cell with Cycling)

  • 김종욱;구할본;문성인;윤문수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1034-1038
    • /
    • 1995
  • The purpose of this study is to research and develop $TiS_2$ composite cathode for lithium polymer battery(LPB). $TiS_2$ electrode represent a class of insertion positive electrode used in Li secondary batteries. In this study, we investigated preparation of $TiS_2$ composite cathode and AC impedance response of $TiS_2$ composite/SPE/Li cells as a function of state of charge(SOC) and cycling. The resistance of B type cell using $TiS_2PEO_8LiClO_4PC_5EC_5$ composite cathode was lower than that of A type cell using $TiS_2PEO$ composite cathode. The cell resistance of B type cell is high for the first few percent discharge, decreases for midium discharge and then increases again toward the end of discharge. We believe the magnitude of the cell resistance is dominated by passivation layer impedance and small cathode resistance. AC impedance results indicate that the cell internal resistance increase with cycling, and this is attributed to change of passivation layer impedance with cycling. The passivation layer resistance($R_f$) of B type cell decreases for the 2nd cycling and then increases again with cycling. Redox coulombic efficiency of B type cell was about 141% at 1st cycle and 100% at 12th cycle. Also, $TiS_2$ specific capacity was 115 mAh/g at 12 cycle.

  • PDF

중방식 도료의 내식성에 관한 전기 화학적 평가(II) (An Electrochemical Evaluation on the Corrosion Resistance of Heavy Anticorrosive Paint(II))

  • 성호진;김진경;이명훈;김기준;문경만
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.382-387
    • /
    • 2005
  • An electrochemical evaluation on the corrosion resistance for heavy anticorrosive paint was carried out for 5 kinds of heavy anticorrosive paints such as High solid epoxy(HE), Solvent epoxy(SE), Tar epoxy(TE), Phenol epoxy(PE), and Ceramic epoxy(CE) as parameters of DFT(Dry Film Thickness, 25${\mu}m$50${\mu}m$, solution condition(Flow of Nonflow). Corrosion current density of HE(DFT 50${\mu}m$ in case of flow condition was larger than that of nonflow condition. However, their values of the other anticorrosive paints were decreased compared to the nonflow condition. The values of AC impedance were increased with increasing of DFT regardless of kinds of anticorrosive paints. And the polarization resistance of cyclic voltammogram showed a good tendency to correspond with well the values of AC impedance measurement. HE and CE had a relatively good corrosion resistance than other heavy anticorrosive paint.

  • PDF

외부 교류자장이 Bi-2223테이프의 동저항 및 손실특성에 미치는 영향 (Effect of an External AC Magnetic field on Dynamic Resistance and Loss Characteristic in a Bi-2223 Tape)

  • 류경우;최병주
    • 한국전기전자재료학회논문지
    • /
    • 제18권5호
    • /
    • pp.473-477
    • /
    • 2005
  • A Bi-2223 tape has been developed for power applications such as a fault current limiter, a power cable and a superconducting magnetic energy storage system. In such applications, the Bi-2223 tape carries time varying transport current and in addition experiences time varying external magnetic field. It is well known that the external magnetic field not only causes magnetization loss in the Bi-2223 tape, but also drastically increases transport loss due to a so-called 'dynamic resistance' We developed an evaluation setup, which can measure transport loss in external at magnetic fields. Using this equipment, we measured the dynamic resistances for various amplitudes and frequencies of an external at magnetic field perpendicular to the face in the tape. Simultaneously we investigated the effect of an external ac field on transport loss with different experimental conditions. This paper describes test results ana discussions on correlation between the dynamic resistance and the transport loss for the Bi-2223 tape.

알루미늄 합금의 미세조직 개선에 의한 절삭 가공 특성 향상 (Machining Characteristics Elevation by Micro-structure Improvement of Aluminum Alloy)

  • 채왕석;김경우;최현민;김동현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.290-295
    • /
    • 2002
  • This research has been carried out to experiment machining characteristics by elements addition and subtraction of AC8B and sample that is used fur car piston materials. 1.Mechanical properties of development sample expressed unique mechanical properties than AC8B. 2. Cutting resistance of development sample decreased about 10% than AC8B according to increase of the cutting speed. 3. According to increase of the feedrate, all comparison workpiece found that specific cutting resistance decrease. 4. It was found that sample's machining characteristics that is developed by addition and subtraction of elements improves.

  • PDF

외부 교류지장에 대한 Bi-2223테이프의 통전손실 특성 (Transport Loss Characteristics of a Bi-2223 Tape in External AC Magnetic Fields)

  • 류경우;김창완;차귀수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권6호
    • /
    • pp.290-295
    • /
    • 2001
  • The transport loss of a Bi-2223 tape exposed to external magnetic fields was investigated. The results show that the transport loss is independent on voltage lead arrangements in case the magnetization loss is compensated. A serous increase of the transport loss due to external AC magnetic field is observed. The loss is described well by dynamic resistance loss in relatively high fields, but another mechanism than the dynamic resistance must be responsible for the increase of the loss in low fields. The transport loss is also dependent strongly on the orientation of the external fields.

  • PDF

Corrosion Rate of Buried Pipeline by Alternating Current

  • Song, H.S.;Kim, Y.G.;Lee, S.M.;Kho, Y.T.;Park, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2005
  • An alternating current (AC) corrosion on buried pipeline has been studied using coupon and ER probe. Coupons and ER probes were applied to the sites from high value of AC voltage to low value based on the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion (; below -850 mV vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relation could be obtained according to effective AC current density, in which AC corrosion rate increased linearly with effective AC current density, and its slope was 0.619 in coupon method and 0.885 in ER probes.

단상 트랜스-Z-소스 AC-AC 컨버터 (Single-phase Trans-Z-Source AC-AC Converter)

  • 신현학;채준영;정민재
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.407-408
    • /
    • 2015
  • The existing (q)Z-source PWM AC-AC converters have limited voltage gain because of the equivalent series resistance in the Z-source inductor. In order to obtain higher voltage gain than (q)Z-source AC-AC converters, a coupled inductor (or transformer) based Z-source AC-AC converter is proposed in this paper. By increasing turns ratio of the coupled inductor more than 1, the proposed converter can obtain higher output voltage than (q)Z-source converters with the same duty ratio. A 120 W prototype AC-AC converter is built and tested to verify performances of the proposed converter.

  • PDF