• Title/Summary/Keyword: ac PDP(alternating current Plasma Display Panel)

Search Result 16, Processing Time 0.019 seconds

A Study on the Surface Characteristics of MgO Layer as the Various Deposition Methods of Electron-beam Evaporation (Electron-beam Evaporation의 증착 방법에 따른 MgO Layer의 표면 특성에 관한 연구)

  • Heo, Jeong-Eun;Lee, Don-Kyu;Cho, Sung-Yong;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.5
    • /
    • pp.468-473
    • /
    • 2008
  • A MgO layer is used as electrode protective film in the alternating current plasma display panel (AC PDP). The properties of MgO layer are thought to be one of the most important factors that affects the panel reliability through the firing voltage variation. In this study, we investigated the relations between the surface characteristics and e-beam evaporation process parameters such as deposition rate, temperature of substrate and distance between the MgO pellet and substrate. To produce the MgO layer of (200) crystal orientation, we suggest the high temperature of the substrate, the long distance between the pellet and substrate and the high deposition rate.

A Study of Discharge Characteristics in Xe-Ne Gas Mixture for ac PDP with Long Gap Hump Electrode (Long Gap Hump 전극구조를 가진 ac PDP에서의 Xe-Ne 가스의 방전 특성 연구)

  • Heo, Jong-Cheol;Ok, Jung-Woo;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.155-159
    • /
    • 2009
  • To increase the luminance and luminous efficacy in the discharge for alternating current plasma display panel (ac PDP), the increment of Xe contents and long discharge gap are necessary. However, the driving voltage and the cost of driving circuit increases in the high Xe contents and long discharge path condition. In this paper, a long gap ITO hump electrode (LGH) model for discharge cells of ac PDP is evaluated in the various Xe contents($5{\sim}20%$). The discharge voltage of LGH structure is lower about 30V than that of ITa reference structure with same main discharge gap. The LGH structure has lower power consumption and higher luminance than those of reference structure, respectively. Also, the luminous efficacy of LGH structure is higher about 20% than that of ITO reference structure in the 20% Xe contents.

Micro-discharged plasma density, electron temperature and excited xenon density for enhancement of vacuum ultraviolet luminous efficiency in alternating current plasma display panel

  • Choi, Eun-Ha;Oh, Phil-Yong;Seo, Yoon-Ho;Cho, Guang-Sup;Uhm, Han-S
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.161-166
    • /
    • 2005
  • The plasma ion density in AC-PDP has shown to be increased from $5.6{\times}10^{11}cm^{-3}$ to $9.0{\times}10^{11)cm^{-3}$ as the Xe mixture ratio to neon increase from 1 % to 10 %, respectively, at fixed pressure of 400 Torr, by using the micro-Langmuir probe. It is noted that the plasma ion density is density increases as the gas pressure increases in this experiment. The electron temperature decreases from 2.3 to 1.2 eV as the Xe mole fraction increases from 1 % to 10 % at fixed pressure of 400 Torr, which is measured by the micro Langmuir probe and high-speed ICCD camera in this experiment. It is noted that the electron temperature decreases as the gas pressure increases from 150 to 400 Torr in this experiment. It is also observed that the exited Xe atom density and the plasma ion density are in strong correlation sharp between each other in this experiment. It is noted that $5.2{\times}10^{12}cm^{-3}$ in the $1s_5$ metastable state and $1.2{\times}10^{12}cm^{-3}$ in the $1s_4$ resonance state for the PDP cell with gap of 50 um distances under the fixed gas pressure of 400 Torr and Xe content ratio of 10 %.

  • PDF

Influence of Sustaining Frequency on the luminous Efficiency in AC-PDP (교류형 플라즈마 디스플레이에 있어서 유지방전 주파수에 따른 발광 효율에 미치는 영향)

  • 정의선;김대일
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.1-5
    • /
    • 2000
  • Recently alternating-current Plasma Display Panel(AC-PDP) is in the spotlight as a digital television and high definition television. The panel structure widely adapted in commercial AC-PDP is three electrodes surface discharge type. At present time, the luminous efficiency is around 1lm/W, it should be a key factor for the commercialization. For the high luminous efficiency, the development of panel structure is necessary. At a given panel structure, a driving method should be optimized to get a sufficient luminous efficiency. The display image of AC-PDP could be realized by the repeated light emission from the discharge. Because most of discharge power is consumed in the sustaining period, the optimization of sustaining waveform is very important for the high luminous efficiency. ADS (Address and Display period Separated) driving method is commonly used. The average driving frequency of ADS driving method is ranged by several tens kilo of [kHz], however the actual frequency of sustaining period is in range of 100[kHz] to 200[kHz]. Based on this study, when the phosphor emits the visible light, it has a decay time of few milliseconds due to the material transfer to the phosphor to emit the visible light. Consequently the luminous efficiency decreases in proportion to the driving frequency. It is found that the luminous efficiency could be significantly improved by the low frequency sustaining driving method.

  • PDF

A Study on the Discharge Characteristics of an Ac PDP with the Variation of Scan Electrode Driver (PDP 스캔 전극 구동방식에 따른 방전 특성의 변화에 관한 연구)

  • Kim, Joong-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.13-18
    • /
    • 2005
  • The variation of discharge characteristics of an ac PDP was observed with the charge of scan electrode driving circuit. Conventional scan electrode driving circuit provides two switches per one scan line, and the suggested one can be constituted by one switch per one scan line with the consideration of capacitive load characteristic of an ac PDP. To verify the workability of the suggested scheme, the performances of the ac PDP was investigated. The dynamic voltage margin was slightly decreased with the adoption of the suggested scheme, which is estimated to result from the misfiring of unselected discharge cells due to the deformation of voltage level of the neighboring scan electrode. In the observation of the delay characteristics of addressing discharge, the performances of the conventional circuit and the suggested one are assumed to be equivalent.

Comparison of the fluid simulation with experimental data of excited Xe species density in PDP cell

  • Yang, Sung-Soo;Ko, Sang-Woo;Kim, Hyun-Chul;Mukherjee, Sudeshna;Lee, Jae-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.739-742
    • /
    • 2003
  • We have compared 2-D and 3-D fluid simulation results of alternating current plasma display panel (AC-PDP) cell with experimentally measured two kinds of excited Xe species $Xe^{\ast}(^{3}P_{1})$ and $Xe^{\ast}(^{3}P_{2})$ characteristics. Although direct experimental access and diagnostics of the discharge in a PDP cell is problematic due to the small cell size, some of experimental technologies have made it possible to diagnose the behavior of excited Xe species [1, 2]. The simulation shows the similar characteristics to the experimental results in the excited Xe species density distribution and the number of excited Xe atoms in anode and cathode region. In certain cases, we obtained the arch-shaped discharge path between two sustain electrodes due to the additional pulse applied to address electrode analogous to experiment. This long path discharge induced higher luminous and discharge efficiency compared to the standard case.

  • PDF