• 제목/요약/키워드: abutment-implant connection

검색결과 132건 처리시간 0.023초

Comparison of marginal bone loss between internal- and external-connection dental implants in posterior areas without periodontal or peri-implant disease

  • Kim, Dae-Hyun;Kim, Hyun Ju;Kim, Sungtae;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제48권2호
    • /
    • pp.103-113
    • /
    • 2018
  • Purpose: The purpose of this retrospective study with 4-12 years of follow-up was to compare the marginal bone loss (MBL) between external-connection (EC) and internal-connection (IC) dental implants in posterior areas without periodontal or peri-implant disease on the adjacent teeth or implants. Additional factors influencing MBL were also evaluated. Methods: This retrospective study was performed using dental records and radiographic data obtained from patients who had undergone dental implant treatment in the posterior area from March 2006 to March 2007. All the implants that were included had follow-up periods of more than 4 years after loading and satisfied the implant success criteria, without any peri-implant or periodontal disease on the adjacent implants or teeth. They were divided into 2 groups: EC and IC. Subgroup comparisons were conducted according to splinting and the use of cement in the restorations. A statistical analysis was performed using the Mann-Whitney U test for comparisons between 2 groups and the Kruskal-Wallis test for comparisons among more than 2 groups. Results: A total of 355 implants in 170 patients (206 EC and 149 IC) fulfilled the inclusion criteria and were analyzed in this study. The mean MBL was 0.47 mm and 0.15 mm in the EC and IC implants, respectively, which was a statistically significant difference (P<0.001). Comparisons according to splinting (MBL of single implants: 0.34 mm, MBL of splinted implants: 0.31 mm, P=0.676) and cement use (MBL of cemented implants: 0.27 mm, MBL of non-cemented implants: 0.35 mm, P=0.178) showed no statistically significant differences in MBL, regardless of the implant connection type. Conclusions: IC implants showed a more favorable bone response regarding MBL in posterior areas without peri-implantitis or periodontal disease.

임상적 방법을 이용한 내부연결 임플랜트에서 고정체수준 인상법의 정확도 평가 (EVALUATION OF THE ACCURACY OF FIXTURE-LEVEL IMPRESSION TECHNIQUE FOR INTERNAL CONNECTION IMPLANT USING CLINICAL METHODS)

  • 최정한
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.421-431
    • /
    • 2006
  • Statement of problem : Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression technique in internal connection implant system. Purpose: This study evaluated the accuracy of splinted fixture-level impression technique using clinical methods and the effect of internal hex on fit of superstructure in internal connection implant system (Astra Tech). Material and method : Two metal master frameworks made from two abutments (Cast-to Abutment ST) each for parallel and divergent conditions and a corresponding. passively fitting, dental stone master cast with four future replicas (Fixture Replica ST) were fabricated. Ten dental stone casts were made with vinyl polysiloxane impressions from the master cast by acrylic resin splinted fixture-level impression technique. To evaluate the accuracy of impression technique, the fit of master frameworks for test models was evaluated using screw resistance test (SRT) and one-screw test. The results of SRT were recorded as SRT values from grade 1 to grade 5 by 1/4 turn. And to evaluate the effect of hex on fit of superstructure, the same tests were performed after removing hexes of master frameworks. Results: 1. There was only one case (2.5%) showing SRT value of test model below ade 2 in total before and after removing hexes of master frameworks. And, by removing hexes. SRT values decreased in only one test model (5%) and did not change in 17 test models (85%). 2. SRT values of the 1$^{st}$ screws were grade 2 in 80% of cases before, and grade 1 in 80% of cases after removing hexes. And, by removing hexes, SRT values decreased in 72.5% of cases. 3. SRT values of the 2$^{nd}$ screws were grade 3 in 85% of cases before, and grade 3 in 95% of cases after removing hexes. And, by removing hexes, SRT values did not change in 85% of cases. 4. There were only 2 cases regarded as acceptable fit by one-screw test, and SRT values of 2$^{nd}$ screws of both cases were grade 2. Conclusion. Within the limitations of this study, future-level impression of internal connection implant system is considered to obtain inaccurate working cast, even using acrylic resin splinted impression technique. And, it is considered to be unable improve the fit to remove the hexes of implant restoration.

내부 원추형 연결형태 임플란트에서 지대주 나사머리의 좌면각도가 연결부 기계적 안정성에 미치는 영향 (Influence of bearing surface angle of abutment screw on mechanical stability of joint in the conical seal design implant system)

  • 김주현;허중보;윤미정;강은숙;허재찬;정창모
    • 구강회복응용과학지
    • /
    • 제30권3호
    • /
    • pp.206-214
    • /
    • 2014
  • 목적: 내부 원추형 연결형태 임플란트에서 지대주 나사의 좌면각도가 연결부의 기계적 안정성에 미치는 영향을 알아보기 위함이다. 연구 재료 및 방법: 원추형 연결구조 티타늄 임플란트와 시멘트 유지형 지대주, 텅스텐 카바이드 코팅된 티타늄 합금 지대주 나사를 사용하였다. 좌면각도가 $45^{\circ}$$90^{\circ}$를 갖는 지대주와 지대주 나사를 제작하여 30 Ncm 조임회전력으로 지대주를 체결한 후 하중을 가하고 체결 및 하중 부여에 따른 침하량을 측정하였다(n = 5). 유압식 피로시험기에 임플란트를 고정하고 스테인리스 스틸 금속관을 지대주에 합착하였다. 이 후 반복 하중을 가한 후 풀림토크 변화량을 측정하고, 압축굽힘강도와 피로강도를 측정하였다(n = 5). 결과: 지대주 침하량은 지대주나사 체결 시 가장 크게 나타났으며(P < 0.05), 나사체결과 하중부여에 따른 총 침하량은 $45^{\circ}$군보다 $90^{\circ}$군에서 더 크게 측정되었다(P < 0.05). 반복하중 부여 후 풀림 토크, 그리고 최대 압축굽힘강도와 피로강도는 통계적으로 유의한 차이를 보이지 않았다(P > 0.05). 결론: 본 실험조건하에서 지대주 나사머리의 원추형 설계가 지대주의 총 침하량을 약간 감소시키는 효과를 나타냈으나, 연결부의 전체적인 기계적 안정성에 미치는 영향은 크지 않을 것으로 판단된다.

A STUDY ON THE CHANGE OF IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS

  • Park Chan-Jin;Kim Yung-Soo;Kim Chang-Whe;Cho Lee-Ra;Yi Yang-Jin
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.271-287
    • /
    • 2003
  • Statement of problem: Resonance frequency analysis (RFA) has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized baseline data using RFA. Purpose: This study was performed to evaluate RFA value changes in two stage surgery group and one stage surgery group in patients. Material and method: Forty-seven mandibles in consecutively implant installed patients were selected for this study and 141 fixtures were installed. Ninety-three fixtures were double threaded, machined surface design ($Br{\aa}anemark^{(R)}$ MK III, Nobel Biocare AB, Goteborg, Sweden) and 48 fixtures were root form, threaded, HA-coated surface one ($Replace^{TM}$, Steri-Oss/Nobel Biocare AB, USA). Among those, each 10 fixture was installed in one stage group patients. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, at healing abutment connection and in the loading period for two stage surgery group patients and during at each 4, 6, 8, 10, 12week and in the loading phase for one stage surgery group patients and evaluated the changes according to the time and fixture type. Results: In two stage surgery group, mean and SO of ISQ values of machined surface implants were $76.85{\pm}3.74,\;75.76{\pm}5.04,\;75.73{\pm}4.41$ and those of HA-coated surface implant were $75.05{\pm}6.23,\;77.58{\pm}5.23,\;78.32{\pm}4.29$ during fixtures installation, at healing abutment connection and in the loading period, respectively. In one-stage surgery group, the ISQ values of machined surface and HA-coated surface implants decreased until 4 or 6 week and maintained at plateau for 1-3 week and increased to the loading period. Conclusions: Machined and HA-coated surface implants showed minimal ISQ changes with time if they were installed at the sites showing at least intact cortical plate and good bone qualities. And HA-coated implants had a tendency to show somewhat increased ISQ values with time.

CAD/CAM으로 제작한 점막하 지르코니아 임플란트 보철 수복 증례 (Submucosal zirconia implant prosthesis fabricated with CAD/CAM)

  • 장재승;김선재
    • 대한치과보철학회지
    • /
    • 제52권4호
    • /
    • pp.352-358
    • /
    • 2014
  • 최근 지르코니아와 CAD/CAM을 이용하는 심미적인 임플란트 보철치료 방법들이 많이 소개되고 있다. 그러나 이러한 방법들은 치은부위와 교합면부위에서 한계점들을 가지고 있다. 이에 본 증례에서는 지르코니아와 CAD/CAM 시스템을 이용하여 고정체 1 mm 상부에서부터 형성되는 점막하지르코니아 임플란트 보철물을 제작하고 이를 타이타늄 지대주와 접착하여 시멘트 나사 유지형 보철물을 제작하였다. 임상적으로 심미적이고 기능적면에서 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

보철물 조건에 따른 Periotest수치의 실험적 평가 (IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES)

  • 한중석
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

2종의 임플란트 내부결합구조체에 따른 치조골상 유한요소응력 분석 (Finite Element Stress Analysis of Bone Tissue According to the Implant Connection Type)

  • 변욱;정다운;한인혜;김성량;이창희
    • 구강회복응용과학지
    • /
    • 제29권3호
    • /
    • pp.259-271
    • /
    • 2013
  • 임플란트 고정체-지대주 결합구조체의 형태에 따른 교합부하의 반응이 다양하여 본 연구에서는 하중위치 및 결합구조체 접촉 비율에 따라 3단 계단형 결합구조체와 경사형에서 어떠한 차이가 있는 지를 3차원 유한요소분석을 시행하였다. 2종의 임플란트-지대주 결합 구조체에 연결된 상부 치관을 제작하여 각 치관에 설정된 하중위치에 200 N의 하중을 부여하였다. 임플란트 중심 부위에서 하중조건이 멀어질수록 피질골정에 가해지는 응력이 증가되기에 하중조건은 응력발생에 영향을 미치는 주요 요소이며 다음으로 결합구조형태에도 영향을 받았다. 또한 수직 하중에 비해 빗금 경사 하중이 부여된 경우 계단형은 경사형에 비해 유리한 응력 분포를 보였다. 그리고 지대주 결합구조체가 고정체의 내벽에 대해 접촉이 많아 질수록 골질에 대한 응력분산이 유리한 것으로 나타났다. 결론적으로 고정체 폭경에서 벗어난 빗김 수직 및 경사 하중은 결합구조체의 종류와 관계없이 피질골정에 응력을 집중시키므로 저작기능시 교합접촉면을 고정체의 폭경 내에 위치하도록 하는 것이 생체역학적으로 바람직 할 것으로 사료되었다.

임플란트 연결부의 개념과 적용: Part 1. 원추형 내부연결 임플란트의 식립과 보철 (Concept and application of implant connection systems: Part I. Placement and restoration of internal conical connection implant)

  • 고경호;강현구;허윤혁;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제36권4호
    • /
    • pp.211-221
    • /
    • 2020
  • 원추형 내부연결 임플란트의 독특한 생역학적 현상이 수직침하와 전하중 상실이다. 원추형 내부연결 임플란트에서 수직적 정지점의 부재로 발생하는 수직침하에 의해 나사의 전하중이 상실되고 교합이 낮아지는 현상이 유발된다. 원추형 내부연결 임플란트에 발생하는 응력은 나사가 아니라 지대주가 접촉하는 계면에 집중되므로 식립할 때는 가급적 상부직경이 두꺼운 임플란트를 선택하는 것이 중요하다. 원추형 내부연결 임플란트는 치조정보다 하방에 식립해야 하며 수복 시에는 적절한 지대주 형태와 정확한 연결을 가지는지 주의해야 한다. 최상의 임상적 결과를 얻기 위해서는 상부 직경을 잘 선택하고 적절한 위치에 식립하여 수복하는 것이 필요하다.

임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구 (Effect of Tightening Torque on Abutment-Fixture Joint Stability using 3-Dimensional Finite Element Analysis)

  • 엄태관;서승우;전계록;신정욱;정창모
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.125-135
    • /
    • 2009
  • 연구목적: 임플란트 치료에서 흔히 발생하는 기계적인 문제점을 하나가 지대주나사의 풀림과 파절이다. 일반적으로 나사 연결의 안정성을 위해서는 지대주나사의 조임회전력에 의한 전하중을 나사의 탄성한계까지 증가시킬 필요가 있다. 그러나 저작운동에 의한 기능부하는 전하중이 가해진 지대주나사에 추가적인 인장력을 가하게 되어 나사의 풀림이나 파절의 가능성을 높인다. 이러한 풀림이나 파절을 방지하면서 동시에 최대의 결합 강도를 가지는 조임회전력을 찾는 연구가 필요하다. 본 연구는 지대주나사의 조임회전력이 임플란트-지대주 연결부 안정성에 미치는 영향을 3차원 유한요소 분석을 통하여 확인하고자했다. 연구 재료 및 방법: External butt joint를 가진 임플란트를 기반으로 3차원 유한요소 해석모형을 설계하였다. 조임회전력에 따른 지대주나사의 전하중을 이론치, 실험치 및 해석치를 비교하여 해석모형을 검증하였다. 검증한 해석모형에서 대해 조임회전력을 10 Ncm, 20 Ncm, 30 Ncm, 그리고 40 Ncm로 각각 적용하고 지대주에 30도 경사지게 250 N의 외부하중을 가하여 유산요소 해석을 실시하였다. 그 결과를 통해 지대주나사의 최대 등가응력을 계산하고 고정체와 지대주 연결부의 응력분포 및 이개거리(gap distance)를 산출하였다. 결과 및 결론: 본 연구조건 하에서 다음과 같은 결과를 얻었다. 1. 전하중은 조임회전력이 클수록 증가하였다. 2. 조임회전력 적용 후 최대 등가응력은 지대주나사 경부에서 발생하였으며, 나사산 체결부에서는 주로 경부쪽 네 개의 나사산에 응력이 집중되었다. 3. 외부하중을 가했을 때에도 조임회전력을 적용했을 때와 동일하게 최대 등가응력은 주로 지대주나사 경부에서 발생하였으나, 10 Ncm의 조임회전력을 적용한 경우에서는 지대주나사 두부밑면에서 발생하였다. 4. 외부하중을 가했을 때 10 Ncm와 20 Ncm의 조임회전력을 적용한 경우에서는 연결부 이개(joint opening) 현상이 관찰 되었다. 5. 조임회전력이 40 Ncm인 경우에는 경사하중에 의해 지대주나사의 경부에 발생하는 최대등가응력이 나사의 소재인 티타늄 합금의 허용응력을 초과하였다. 이상의 결과로 볼 때, 조임회전력은 고정체와 지대주 연결부의 안정성에 영향을 미치는 것이 확인되었다. 임플란트 지대주나사는 임상에서 발생하는 기능 하중을 고려하여 고정체와 지대주 연결의 안정성을 유지할 수 있는 적정 조임회전력의 크기가 제안되어야 한다.