• Title/Summary/Keyword: absorption simulation

Search Result 532, Processing Time 0.029 seconds

Dynamic Models and Simulation of the Absorption Air Conditioning System (흡수식 공조 시스템의 동적 모델과 시뮬레이션)

  • 한도영;이승기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.994-1003
    • /
    • 2000
  • Control algorithms for the absorption air conditioning system may be developed by suing dynamic models of the system. The simplified effective dynamic models, which can predict the dynamic behaviors of the system, may help the development of effective control algorithms for the system. In this study, a dynamic simulation program for the absorption air conditioning system was developed. Dynamic models for an absorption chiller, a cooling tower, an air handling unit, a boiler, a three way valve, a controller, and a duct were developed and programed. Control algorithms for the absorption chiller, the cooling tower, and the air handling unit were selected, and analyzed to show the effectiveness of dynamic models. From the simulation results, it may be concluded that this simulation program may be effectively used for the development of optimal control algorithms of the absorption air conditioning system.

  • PDF

Simulation of the Characteristics of High-Performance Absorption Cycles (고성능 흡수냉동 사이클의 특성 시뮬레이션)

  • 윤정인;오후규;이용화
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.231-239
    • /
    • 1995
  • This paper describes a computer simulation of the triple effect, water-lithium bromide absorption cooling cycles. The performance of the absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature, the working solution concentrations, the ratio of the amount of the weak solution to the high, middle and low temperature generators, and the temperature difference of each solution heat exchanger. The efficiency of different cycles has been studied and the simulation results show that higher coefficient of performance could be obtained for the parallel cycle of constant solution distribution rate. As a result of this analysis, the optimum designs and operating conditions were determined based on the operating conditions and coefficient of performance.

Modeling and simulation on an IR absorbing structure with the cascaded transmission line model (전송선 이론에 의한 적외선 흡수 구조체의 흡수율 모의시험)

  • Park, Seung-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1725-1729
    • /
    • 2013
  • In this paper, the modeling and simulation of infrared absorption in an infrared absorbing structure with the cascaded transmission line model were carried out. Each layer in the infrared absorbing structure can be modeled as a characteristic impedance of the cascaded transmission line model. The simulation results show that the cavity thickness to get a maximum absorption should be less than a quarter wavelength, which is somewhat different from prevalent thickness. It can be assured that the sheet resistance of an absorbing layer to get a maximum absorption is $377{\Omega}/{\square}$, that the thickness of the absorbing layer dose not affect the spectral characteristics of absorption. It is also shown that the thickness of the active layer is not critical to the IR absorption. It can also be assured that the validation of this modeling is proved in comparison with the previous results from similar absorbing structures.

Development for Shock Absorption System by Using FE Analysis (FE 해석을 통한 충격흡수시설의 개발)

  • Kang, Y.H.;Kim, H.J.;Park, D.H.;Kim, K.S.;Kang, B.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.224-229
    • /
    • 2000
  • This paper describe a (mite element computer simulation of a absorption system using full scale car crash test. The full scale test selected for this study is a 80kmh frontal, side and 25% offset impact of a 1993 Ford Taurus vehicle into a absorption system. This absorption system has external rubber and internal steel pannel. This simulation has completed for decision of these components energy absorption performance. Dynamical performance of this system and movement are obtained from this simulation. and then We can appreciate the safety of passenger from measure the vehicle C.G's acceleration.

  • PDF

Solar Absorption System Analysis with Spreadsheet Models (태양열 이용 흡수식 냉난방시스템의 스프레드쉬트 모델)

  • Choi, Hong-Kyu;Fazzolari, Rocco A.
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.15-24
    • /
    • 1992
  • An hourly simulation model of a solar LiBr-water absorption cooling and heating system (for brevity, solar absorption system) is presented, based on SuperCalc spreadsheet computational procedures. This paper demonstrates the value of using spreadsheet simulation techniques by examining the thermal performances of a solar absorption system. The hourly heating and cooling coil loads for a typical office building in Tucson, Arizona are modeled and calculated using ASHRAE methods. The details of the algorithms for the components and control schemes are presented. Two case studies are also presented using real system parameters.

  • PDF

Simulation of Membrane-absorption Hybrid Process for LNG-FPSO (LNG-FPSO용 막-흡수 하이브리드 공정 전산모사)

  • Min, Kwang-Joon;Cho, Habin;Kim, Jin-Kuk;Kang, Sang Wook
    • Membrane Journal
    • /
    • v.28 no.2
    • /
    • pp.90-95
    • /
    • 2018
  • A process design was performed for a removal of acid gases using membrane-absorption hybrid system in LNG-FPSO. Commercial process simulator Promax version 4.0 was utilized for comparing acid gases removal capabilities of amine absorption process and hybrid process. Simulation results show hybrid process could be small amine solvent circulate rate, energy consumption, equipment sizing compared to typical amine absorption process. As a result, hybrid process which is small footprint and energy saving process may be a good solution for the pre-treatment of natural gas in LNG-FPSO.

Numerical simulation on capillary absorption of cracked SHCC with integral water repellent treatment

  • Yao Luan;Tetsuya Ishida
    • Computers and Concrete
    • /
    • v.34 no.1
    • /
    • pp.123-135
    • /
    • 2024
  • Strain-hardening cement-based composites (SHCC) under cracked condition exhibits remarkable capillary absorption due to water ingress from multiple cracks. Surface treatment using water repellent agents is an effective way for improving water resistance of SHCC, but the water resistance may remarkably decrease when cracks penetrate impregnation depth. Another way is to add water repellent agents directly into the mixture, offering SHCC integral water repellency even if cracks form later. However, although integral water repellent treatment has been proved feasible by previous studies, there is still lack of simulation work on the treated SHCC for evaluating its durability. This study presents a simulation method for capillary absorption of cracked SHCC with integral treatment based on a multi-scale approach proposed in the authors' previous work. The approach deals with water flows in bulk matrix and multiple cracks using two individual transport equations, respectively, whereas water absorbed from a crack to its adjacent matrix is treated as the mass exchange of the two equations. In this study, the approach is enhanced for the treated SHCC by integrating the influencing of water repellency into the two transport equations as well as the mass exchange term. Using the enhanced approach, capillary absorption of water repellent SHCC under cracked condition is simulated, showing much more reduced water ingress than the untreated concrete, which is consistent with total absorption data from previous tests. This approach is also capable of simulating water spatial distribution with time in treated SHCC reasonably.

Finite Element Analysis on the Energy Absorption Characteristics of Hybrid Structure (충격흡수용 복합부재의 에너지 흡수특성에 관한 유한요소해석)

  • 신현우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.101-107
    • /
    • 2004
  • Recently the objective of vehicle design was focused on the crash safety and the energy saving. For the energy saving vehicle structures must be light weight, but for the crash safety some energy absorbing elements must be added. In this paper hybrid structure which consists of a steel and a FRP was studied on the energy absorption characteristics under the impact load by finite element method. Test results of the other researchers were compared with that of computer simulation on this simple hybrid structure. Side rail of vehicle front structure was replaced with hybrid materials for the application of the vehicle structure. 35mph frontal crash simulation was performed with hybrid structure and with conventional steel structure. By the adoption of hybrid structure, the improvement of energy absorption characteristics and reduction of weight was observed under the frontal crash simulation.

Performance Characteristics on the Mixed Flow Type Absorption Chiller-Heater (혼합흐름 사이클용 흡수식 냉온수기의 성능특성)

  • Yoon, J.I.;Shin, G.B.;Park, S.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.351-360
    • /
    • 1996
  • This study focuses on the development and evaluation of the high efficiency absorption chiller-heater, which can be applied to a direct gas fired, double effect system with 40RT (508,000kJ) cooling capacity. The performance of the absorption chiller-heater is investigated through cycle simulation and experiment to obtain the system characteristics with the inlet tenperature of cooling, chilled water, and gas input flow rate. The efficiency of the different cycles has been studied and the simulation and experiment results show that higher coefficient of performance could be obtained for mixed flow cycle. The five percent difference was obtained from the comparison between experimental and cycle simulation results. As a result of this study, the optimum designs were determined based on the operating conditions and the coefficient of performance.

  • PDF

Simulation of Solar/Absorption Cooling Hybrid System and Examination of Its Operating Condition (태양열을 이용한 흡수식 냉방시스템의 시뮬레이션과 운전조건의 검토)

  • Her, Jae-Young;Lee, Sang-Yong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 1985
  • Solar/absorption cooling system was analyzed and its operating condition was examined. For the system, the optimum size of absorption refrigerator and collector area should be determined. As the temperature of water supplied to the generator increases, the collector efficiency decreases whereas the coefficient of performance of absorption refrigerator increases up to a certain point, and vice versa for decreasing of the temperature of water supplied to the generator . Thus if the reeling load is given, the appropriate operating condition can be determined between the two opposing trends by simulation program. As an example of the simulation, the case of Jejudo province was studied. Under the conditions (such as weather data and prices of components, etc.) given en the sample calculation, the result shows that the optimum temperature of water supplied to the generator turned out to be $80.3^{\circ}C$, and still shows a large economical disadvantage in present stage compared to the case of conventional vapor compression cooling/heating combined heat pump system.

  • PDF