• Title/Summary/Keyword: absorbent filter

Search Result 13, Processing Time 0.021 seconds

TRANSITIVE AND ABSORBENT FILTERS OF LATTICE IMPLICATION ALGEBRAS

  • Rao, M. Sambasiva
    • Journal of applied mathematics & informatics
    • /
    • v.32 no.3_4
    • /
    • pp.323-330
    • /
    • 2014
  • The notion of transitive filters is introduced in lattice implication algebras. A necessary and sufficient condition is derived for every filter to become a transitive filter. Some sufficient conditions are also derived for a filter to become a transitive filter. The concept of absorbent filters is introduced and their properties are studied. A set of equivalent conditions is obtained for a filter to become an absorbent filter.

Odor Removal with Powdered Adsorbent using Bag-filter System (분말 흡착제를 이용한 악취 저감 여과 집진장치 개발연구)

  • Xu, Rong-bin;Kim, Tae-Hyeung;Ha, Hyun-Chul;Piao, Cheng-Xu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.291-301
    • /
    • 2017
  • Objectives: In order to improve the working environment and solve the complaints, many efforts have been made to remove the odor from the industrial process. There are many disposal methods to remove odor, but there are many disadvantages and inadequate applications. The Purpose of this study was to develop a bag-filer system for odor removal using powder adsorbent. Methods: The bag-filter system is composed of a shear bag filter, an absorbent spraying system and an absorbent circulation system. The spraying absorbent system was connected with the inlet duct of the shear bag filter for inputting adsorbent. And the absorbent circulation system can transport the collecting adsorbent from hoper to the inlet duct of the system. As a result, the adsorbent can remove odor with recycling in the system. Also affective factors like the powdered absorbent combination and injection method was researched for maximization of system efficiency. The study was conducted in two stages. The first step was testing equipment made and the second is to evaluate the efficiency of the odor control by connecting to the actual odor generation process. Results: Both experiment stages showed efficient odor control ability. The adsorption efficiency of the system is demonstrated and the odor was adsorbed well by the powder adsorbent. It is essential to accurately understand the characteristics of the odorous and use the appropriate adsorbent. Although the powder adsorbent was used in the experiment, the problem of scattering did not occur due to the high degree of system sealing. Also the system manufactured in this study was designed to recycle the adsorbent, so adsorbent reuse or batch processing is convenient. Conclusions: The applicability of the system has been proven through this research. Customized systems for industrial process and the appropriate adsorbent base on the characteristics of pollutant generation will show efficient odor collection ability.

Development of Polymeric Water Absorbent Film(PWAF) for the Collection of Size-classified Fog Droplets

  • Ma, Chang-Jin;Mikilo-kasahara;Park, Kum-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E1
    • /
    • pp.17-24
    • /
    • 2001
  • For the purpose of collecting fog droplets as a function of size a new sampling method was developed in this study. Formation of 100$\pm$10㎛ thickness of polymeric water absorbent film (PWAF) on a nuclepore filter could be successfully realized. Also applicability of particle induced X-ray emission (PIXE) method to the chemical analysis of size-segregated fog droplets collected on PWAF was examined experimentally with synthetic fog droplets generated from a nebulizer. Absorption capacity of S-PAAS polymeric water absorbent shows marked decreases in the range less than 1 wt% and slight decrease between 1 and 3.5 wt% of every salt concentration. Dependency of absorption capacity on pH shows the maximum at pH 7. No apparent peak which can influence the quantitative analysis of elements dissolved and suspended in fog droplets was found at PIXE spectrum of PWAF blank. PWAF kept the original shape without rupture under the PIXE analytical conditions of beam intensity for 10 to 60 nA and irradiation time of 4∼5 min. It should be said that the proposed new technique in the work is helpful to get more detailed information of fog droplets, to clarify the fog formation processes, and to develop a model of acid deposition process.

Simultaneous Removal of TVOC and Particulate Matters Using Rectangular Bag-Filter System with for a Foundry (주물공정 악취·분진 동시 처리를 위한 여과 집진장치 개발연구)

  • Xu, Rong-Bin;Kim, Tae-Hyeung;Ha, Hyun-Chul;Piao, Cheng-Xu
    • Journal of Environmental Science International
    • /
    • v.23 no.8
    • /
    • pp.1409-1418
    • /
    • 2014
  • Foundry has an important economic value in the industry. However, the generation of air pollutants like particulate and odor are serious. Due to the unavoidable usage of molding sand, particulate occurs in almost all the processes. That accounts for the majority of respirable dust in the size less than $10{\mu}m$ As well as particulate, over 22 species of odor-causing gases and VOCs including hydrogen sulfide and ammonia are occurred. Therefore, the development of equipment that can simultaneously remove TVOC and particulate is regarded as an essential research. In this study, the spraying absorbent system was connected with the shear bag filter for the purpose to remove TVOC and particulate simultaneously. Maximization of process efficiency for the affective factors like the powder combination and injection method is conducted. The experiment was performed at the de-molding process of one foundry plant. Through these devices, the removal efficiency of more than 95% for TVOC was achieved with the absorbent that composed by 800 mesh Activated carbon (80%) and 300 mesh zeolite (20%). Also, the durability and economic evaluation were assessed. In the result of Durability assessment, the available recovery to maintain the deodorizing effect at 90% was counted to 350 degree.

Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas (흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능)

  • Kwun, Soon-Kuk;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.310-315
    • /
    • 1999
  • The feasibility of an absorbent biofilter system was examined for rural wastewater treatment. Hydraulic loading rates varied from 50 to 250 cm/day. Effluent of the septic tank was fed into the absorbent biofilter, and small ventilation fan was provided to supply air at the rate of 250 L/min to aerate the biofilter. The biofilter system demonstrated high removal rates for $BOD_5$ and TSS at the loading rate of 150 cm/day, generally meeting the Korean effluent water quality standard of 20 mg/L applicable to both. The nutrient removal was less satisfactory than the results of $BOD_5$ and TSS, but it was within the expected range of biological treatment processes. Considering the abnormally high influent concentration of nutrients during the experiment, better performance results could have been obtained if ordinary domestic wastewater was used. The system performance was not significantly affected by the hydraulic loading up to 150 cm/day, which is far more than the loading limit of the sand filter systems. Maintenance requirement was minimal, and no problems with noise, odor, flies or sludge arose. Since the biofilter system can be operated at a distance, operation in remote rural area and multi-system connected to one control office might be advantageous to the rural area. Overall, considering the cost-effectiveness, stable performance, and minimum maintenance, the biofilter system was thought to be a competitive alternative to treat wastewater in Korean rural communities.

  • PDF

Development of a Passive Sampler using a Fluorescence Material for the Ambient Ozone (형광물질을 이용한 대기 중 오존 Passive Sampler의 개발)

  • 임봉빈;정의석;김선태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.483-491
    • /
    • 2004
  • The purpose of this study is to develop an ozone passive sampler and to evaluate its performance p-Acetamidophenol using as the reagent for ozone reacts specifically with the ambient ozone to produce a fluorescence material (p-acetamidopheonl dimer). The volume of absorbent solution and the extraction time determined at suitable conditions for measuring ozone were 100$\mu$L and 60 min, respectively. The changes of fluorescence were observed with incresing the storage period of passive samplers in ambient air. but the cool storage in a refrigerator did not remarkably influence the increase of fluorescence. The measurement for the precision oi the passive sampling was carried out with duplicate measurement of passive samplers. The intra-class correlation coefficients of passive samplers using dry and wet filters were 0.992 and 0.962, respectively The results from field validation tests indicated practical agreement (dry filter: r=0.963, wet filter: r=0.995) between the passive sampler and an UV photometric $O_3$ analyzer. The limit of quantification of ozone passive samplers with sampling time of 8 hr (wet filter) and 24 hr (dry filter) were 8.0 ppb and 2.7 ppb, respectively.

A Study on Adsorption Characteristics of the Heavy Metals using Melting Slag of Incinerator Ash (소각재 용융슬래그를 이용한 중금속 흡착특성에 관한 연구)

  • Yoo, Seung-Chol;Kim, Hwan-Gi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.413-420
    • /
    • 2008
  • In order to utilize cinder melting slag as a filter media to control the quality of early rainwater, its environmental stability was verified by heavy metal elution experiment and improved by pre-treatment. Possibilities of improving its function as an absorbent was considered. Absorption characteristics of melting slag before and after the pre-treatment were analyzed by heavy metal equilibrium and stationary-phase column experiments, which in turn were analyzed by comparison experiment with activated carbon. As a result of heavy metal elution experiment, every metal item existed in a much lower amount than the criteria or was not detected, implying that there is no problem recycling it. Absorption equilibrium experiment showed that the time for pre-treatment melting slag to reach the equilibrium was reduced, while the absorbed amount was greatly increased. Stationary-phase column experiment assures us that the elimination rate was not changed much by influx rate, pH and the change in packing volume rate, indicating that this melting slag can be used not only as a filter media to control the quality of early rainwater but also in many areas of water-processing.

Evaluation of Ventilation System Performance Using Indoor Air Quality Model (실내공기질 모델을 이용한 환기 시스템의 공기 정화 효율성 평가)

  • 최성우
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.57-66
    • /
    • 1997
  • Successful energy conservation and good indcfor air quality (IAQ) are highly dependent on ventilation system. Air filtration is a primary solution of indoor air control strategies in terms of reducing energy consumption and improving ihdoor air quality. A conventional system with bypass filter, as it is called variable-air-volume/bypass filtration system (VAV/BPFS), is a variation of the conventional variable air volume (VAV) systems, which is designed to eliminate indoor air pollutant and to save energy. Bypass filtration system equipped with a high-efficiency particulate filter and carbon absorbent provides additional cleaned air into indoor environments and maintain good IAQ for human health. The objectives of this research were to compare the relative total decay rate of indoor air pollutant concentrations, and to develop a mathematical model simulating the performance of VAV/BPFS. All experiments were performed in chamber under the controlled conditions. The specific conclusions of this research are: 1. The VAV/BPFS system is more efficient than the VAV system in removing indoor air pollutant concentration. The total decay rates of aerosol, and total volatile organic compound (TVOC) for the VAV/BPFS system were higher than those of the conventional VAV system. 2. IAQ model predictions of each pollutant agree closely with the measured values. 3. According to IAQ model evaluation, reduction of outdoor supply air results in decreased dilution removal rate and on increased bypass filtration removal rate with the VAV/BPFS. As a results, we recommends the VAV/BPFS as an alternative to conventional VAV systems.

  • PDF

SOC/SOH Estimation Method for AGM Battery by Combining ARX Model for Online Parameters Identification and DEKF Considering Hysteresis and Diffusion Effects (파라미터 식별을 위한 ARX 모델과 히스테리시스와 확산 효과를 고려한 이중 확장 칼만필터의 결합에 의한 AGM 배터리의 SOC/SOH 추정방법)

  • Tran, Ngoc-Tham;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.401-402
    • /
    • 2014
  • State of Charge (SOC) and State of Health (SOH) are the key issues for the application of Absorbent Glass Mat (AGM) type battery in Idle Start Stop (ISS) system which is popularly integrated in Electric Vehicles (EVs). However, battery parameters strongly depend on SOC, current rate and temperature and significantly change over the battery life cycles. In this research, a novel method for SOC, SOH estimation which combines the Auto Regressive with external input (ARX) method using for online parameters prediction and Dual Extended Kalman Filter (DEKF) algorithm considering hysteresis is proposed. The validity of the proposed algorithm is verified by the simulation and experiments.

  • PDF

Development of a Time-temperature Indicator for Managing the Distribution Temperature of Frozen Mackerel Scomber japonicus (냉동 고등어(Scomber japonicus)의 유통 온도 관리를 위한 Time-temperature Indicator 개발)

  • Choi, Jeong-Wook;Lee, Min-Kyeong;Choi, Jae-Hyuk;Jang, Myung-Kee;Ahn, Dong-Hyun;Nam, Taek-Jeong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.51 no.5
    • /
    • pp.590-594
    • /
    • 2018
  • We developed a time-temperature indicator (TTI) that rapidly determines whether frozen mackerel Scomber japonicus has thawed during its distribution. Our TTI was made from filter paper capable of absorbing mackerel exudate that was soaked in a 20% citric acid solution at pH 4.0 and then dried. The dried absorbent paper was cut and attached to blue litmus paper with a 2 mm overhang. The fixed litmus paper was covered with a polypropylene film and sealed. The indicator was placed inside a polyvinyl vacuum package containing the mackerel sample. The vacuum-sealed packaged was frozen at $-20^{\circ}C$ for 24 h. After freezing, the color change and time dependence of the indicator were observed at room temperature ($25^{\circ}C$) and demonstrated the utility of this TTI for rapidly determining whether frozen mackerel underwent thawing during distribution.