• Title/Summary/Keyword: absorbable suture

Search Result 67, Processing Time 0.021 seconds

Clinical Results of Arthroscopic Bankart Repair with Absorbable Knot-tying and Absorbable Knotless Suture Anchors (견관절 전방 불안정증에서 관절경적 방카트르 봉합술 시 흡수성 매듭 봉합 나사못과 흡수성 비 매듭 봉합 나사못을 이용한 임상적 치료결과 비교)

  • Kim, Seong-Jun;Lu, Yao-Jia;Oh, Kyung-Soo;Bahng, Seung-Chul;Park, Jin-Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.50-55
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the clinical results of absorbable knot-tying and absorbable knotless suture anchors in arthroscopic Bankart repair. Materials and Methods: This study compared the patients who underwent arthroscopic Bankart repairs using absorbable knottying suture anchors (59 patients: KT Group), and absorbable knotless suture anchors (52 patients: KL Group). Preoperative and postoperative evaluations were performed by Rowe scores, patient satisfaction score, visual analogue scale (VAS), American shoulder and elbow surgeons (ASES) score, range of motion (ROM), and re-dislocation rate. Results: Postoperative VAS, Rowe scores, ASES score were significantly not different between the 2 groups (VAS: p=0.250, Rowe score: p=0.412, ASES: p=0.052). Mean postoperative VAS was 0.5 in KT Group and 0.8 in KL Group (p=0.250), and limited ROM was noted only in one patient in KL Group. Mean Rowe score was 94.3 in KT Group and 96.3 in KL Group (p=0.412), and mean ASES score was 97.3 in KT Group and 94.0 in KL Group (p=0.052). Re-dislocation rate were no different between the 2 groups. Conclusion: There were no differences in clinical outcomes and re-dislocation rate between Knot-Tying and Knotless repairs.

  • PDF

The Overlapping Running Suture Method Using Single Knotless Barbed Absorbable Suture Material for Abdominal Wall Closure after Single Incision Laparoscopic Appendectomy: Comparison with the Traditional Interrupted Closure Technique

  • Kim, Dong Hyun;Park, Jung Ho;Joo, Jung Il;Jeon, Jang Yong;Lim, Sang Woo
    • Journal of Minimally Invasive Surgery
    • /
    • v.21 no.4
    • /
    • pp.160-167
    • /
    • 2018
  • Purpose: The aim of our study was to present an abdominal wall closure technique using barbed suture $V-Loc^{TM}$ 90 after single incision laparoscopic appendectomy (SILA) and to compare perioperative outcomes with conventional layer by layer abdominal wall closure after SILA. Methods: From March 2014 to July 2016, a retrospective case-control study was conducted for a total of 269 consecutive patients who underwent SILA. According to abdominal wall closure methods, 129 patients were classified into the V-Loc closure group and 140 patients were assigned into the conventional layer by layer closure group. In the V-Loc group, abdominal wall closure was performed from the fascia to the skin with a single thread of unidirectional absorbable barbed suture $V-Loc^{TM}$ 90 2-0 using continuous running suture and reverse overlapping reinforced running technique. Subcutaneous closure and subcuticular suture were performed with the remaining portion of V-Loc. Results: The V-Loc closure group showed shorter total operation time ($40.0{\pm}15.4min$ vs. $44.9{\pm}16.3min$, p=0.013) and abdominal wall cusing continuous running suture and reverse overlapping reinforced running technique. Subcutaneous closure and subcuticular suture were performed with the remaining portion of V-Loc. Results: The V-Loc closure group showed shorter total operation time losure time ($5.5{\pm}0.9min$ vs. $6.5{\pm}0.8min$, p<0.001). Postoperative incision length was significantly shorter in the V-Loc closure group ($1.1{\pm}0.3cm$ vs. $1.8{\pm}0.4cm$, p<0.001). Postoperative wound pain, time to resume diet, postoperative hospital stay, complications including surgical site infection, or mean patient satisfaction score at one month after hospital discharge was not significantly different between the two groups. Conclusion: In conclusion, unidirectional knotless barbed suture is a safe alternative method for abdominal wall closure after SILA. It can save time while providing comparable cosmesis.

In-vitro and in-vivo Behaviors of Poly(glycolide-caprolactone) Copolymer for Bioabsorbable Suture Materials

  • Yoo, Yeon-Chun;Kim, Hak-Yong;Jin, Fan-Long;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.4137-4140
    • /
    • 2012
  • A novel bioabsorbable suture material, poly(glycolide-caprolactone) (PGLCL) monofilament, was prepared by spinning of the PGLCL copolymer. The physical properties, strength retention, biocompatibility, and organism resolvability of the PGLCL monofilament were investigated. The results showed that the knot pull strength of the monofilament was higher than that stated in European Pharmacopoeia. The in vivo retention strength following implantation was 64%, 23%, 7%, and 0% after one, two, three, and four weeks, respectively. Mortality, clinical signs, validation, and sterility tests indicated that all items had passed. Organism resolvability tests showed that the PGLCL monofilament, as a suture, was absorbed within 91 days.

The Mechanical Appearances and Microscopic Tissue Reactions of the Suture Materials in vivo (생체내 이식된 흡수성 봉합사들의 물리적 성질 변화와 조직 소견에 관한 연구)

  • 김남중;김명철
    • Journal of Veterinary Clinics
    • /
    • v.13 no.2
    • /
    • pp.184-194
    • /
    • 1996
  • A comparative study of three absorbable suture materials of chromic catgut, Dexon II (a polyglycolic acid suture with a polycaprolate coating system) and Coated Vicryl (a polyglactin 910 suture with a glycolide-lactide-calcium stearate coating system) was undertaken in terms of tensile strength, breaking elongation, appearances of the suture materials in the subcutaneous layer of rats and of tissue reaction in the intramuscular layer of rats. The initial tensile strength of chromic catgut and the tensile strength after 21 days were about 1.55 kg and 0.19 kg, respectively. Those of Dexon II were about 2.01 kg and 0. 20 kg, respectively. Those of Coated Vicryl were about 2.39 kg and 0.48 kg, respectively. Coated Vicryl showed the highest tensile strength among the three materials during the whole period. On the other hand, Dexon II showed the highest breaking elongation among the three materials during the first week. But the breaking elongation of Dexon II rapidly continuously decreased during the whole period. The appearances of the suture materials in the subcutaneous layer of rats showed that chromic catgut was the fastest among the three materials, whereas it formed comparatively much connective tissue. The intramuscular absorption rate and tissue reaction of Dexon II were similar to those of Coated Vicryl. The intramuscular absorption rate of these was fairly late when compared with chromic catgut. And the tissue reaction appearance of these showed the formation of a granuloma with foreign body giant cells, macrothages and epitheloid cells by the 28th day in the experimental period.

  • PDF

The Safety and Usefulness of Synthetic Absorbable Monofilament, Glycoside-$\varepsilon$-caprolactonetrimethylene Carbonate Interpolymer, in Gastrointestinal Anastomosis and Closure (위장관문합 및 봉합 시 인공 흡수성 단사인 Glycoside-$\varepsilon$- caprolactone-trimethylene Carbonate 혼성중합체의 안정성 및 유용성)

  • Lee Hyuk-Joon;Kim Yoon Ho;Yang Han-Kwang;Lee Kuhn Uk;Choe Kuk Jin
    • Journal of Gastric Cancer
    • /
    • v.3 no.2
    • /
    • pp.93-96
    • /
    • 2003
  • Purpose: Synthetic absorbable monofilaments offer excellent glide characteristics and cause minimal tissue trauma as a result of their smooth monofilament structure and gradual absorption within the healing tissues. For these reasons, these suture materials are commonly used in various surgical fields such as gastroenterology, urology, gynecology, and plastic surgery. The aim of this study was to evaluate the safety and usefulness of a new synthetic absorbable monofilament, Glycoside-..-caprolactone-trimethylene carbonate interpolymer (GCT), in gastrointestinal anastomosis and closure. Materials and Methods: We evaluated 55 gastrointestinal anastomoses and closures using GCT $MONOSYN^{R}$, B. Braun, Germany) in 47 patients who underwent gastric surgery between December 2001 and May 2002 at Seoul National University Hospital. Patient's characteristics, operative procedure, surgeon's opinion of handling properties of GCT, and suture-related complications were analyzed. Results: There were 34 males and 13 females (M:F= 2.6:1) with an average age of 54.2 years old. Forty-five cases of gastrointestinal anastomosis (20 gastrojejunostomies and 25 jejunojejunostomies) and 10 cases of intestinal closure (7 gastrostomy closures and 3 duodenal stump closures) were performed in 41 cases of stomach cancer, three of peptic ulcer disease, two of GIST, and one MALToma. The handling properties of GCT according to the criteria of knot breaking load, knot security, and placing property were always scored with 7 to 9 points (10=excellent, 1=very poor). Two cases of postoperative complications ($3.6\%$) were noted. One was a leak of the gastrojejunostomy site which was successfully managed conservatively, and the other was a stricture of the gastrojejunostomy site which was managed by reoperation (side-to-side jejunojejunostomy). Conclusion: GCT seems to be an applicable suture material for various gastrointestinal anastomoses and closures.

  • PDF

Ventriculoperitoneal Shunt without Hair Shaving Using Absorbable Suture Materials

  • Lee, Yun Ho;Kwon, Young Sub;Cho, Jin Mo
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.120-124
    • /
    • 2021
  • Objective : Infection is one of most devastating complications in ventriculoperitoneal (VP) shunt surgery. Preoperative hair removal has traditionally been performed to reduce infectious complications. We performed VP shunt surgeries and evaluated the prevalence of infection in patients who were shaved and those who were unshaven. Methods : A retrospective analysis was conducted of 82 patients with hydrocephalus of various pathologies who underwent VP shunt surgery, with or without having the head shaved, between March 2010 and March 2017. For patients in the non-shaved group (n=36), absorbable suture materials were used for wound closure, and Nylon sutures or staples were used in the shaved group (n=46). We evaluated the infection outcomes of patients in the two groups. Results : There was no difference in the average age of patients in the two groups. In the non-shaved group, there were no infections, while two patients in the shaved group required revision because of shunt infection. Conclusion : Non-shaved shunt surgery may be safe and effective, with no increase of infection rate. We recommend that shunt procedures could be performed without shaving the hair, which may increase patients' satisfaction without increasing infection risk.

A Case of Bladder Stone and Vesicovaginal Fistula after McDonald Operation (자궁경부봉축술 후 발생한 방광석 및 방광질루 1 예)

  • Yoon, Chang-Jun;Moon, Ki-Hak;Jung, Hee-Chang
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.108-112
    • /
    • 2006
  • The frequency of a bladder foreign body in the female is lower than in the male, and bladder stones attached to foreign bodies such as non-absorbable suture material are not common. Moreover, vesicovaginal fistulas due to migration or puncture of suture materials into the bladder are rare. In this report, we present a case of bladder stone and vesicovaginal fistula formation in a 29-year-old female patient who had been treated with the McDonald operation for an incompetent internal os of the cervix (IIOC) during pregnancy. The patient was successfully treated by cystoscopic removal of the bladder stone with suture material and conservative treatment for the vesicovaginal fistula.

  • PDF

Comparative Study of Tissue Response of Various Suture Materials in Rats (수종의 봉합사의 조직반응에 관한 비교연구)

  • Kim, Jae-seok;Park, Joon-Bong;Lee, Man-Sup;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.113-127
    • /
    • 2002
  • The purpose of this study is to evaluate histologically the tissue response and resorption of various nonresorbable and resorbable suture materials used for periodontal surgery, using a subcutaneous model on the dorsal surface of the rat. In this study, 10 Sprague-Dawley male rats (mean BW 150gm) were used and the commercially available materials included polyglactin 910, pain gut, nylon, e-PTFE. Animals were sacrificed at 3 days, 1, 2 and 4 weeks after implantation of various nonresorbable and resorbable suture materials. Specimens were prepared with Hematoxylin-Eosin stain for light microscopic evaluation. The results of this study were as follows: 1. Resorption : The resorption of plain gut was showed at 1 week after implantation, was lost their structure and almost resorbed at 4 weeks. The resorption of polyglactin 910 was started at 2 weeks and slowly absorbed untill 4 weeks. 2. Tissue response : Plain gut showed persistent and severe inflammatory reactions from 3 days to 4 weeks. Polyglactin 910, e-PTFE and nylon showed mild inflammatory reactions. Suture material should be biocompatible and be able to be functioned until tissue tensile strength reaches maximum level. In this study, polyglactin 910, nylon and e-PTFE are considered to be proper suture materials for periodontal surgery.

Effectiveness of Vicryl $plus^{(R)}$ (Ethicon, USA) in Nosocomial Bacteria (실제 병원성 균주에서 Vicryl $plus^{(R)}$ (Ethicon, USA)의 효용성)

  • Jin, Young-Wan;Na, Young-Cheon
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.590-593
    • /
    • 2011
  • Purpose: Surgical site infections (SSIs) are the third most frequently reported nosocomial infection. Of these SSIs, mostly were confined to the incision associated with underlying disease as diabetes, cigarette smoking, systemic steroid use, obesity, operating room environment, suture and surgical technique. This study has been planned to reduce the SSIs by using Vicryl $plus^{(R)}$ (Ethicon, USA) which contains triclosan, a broad-spectrum antibacterial agent, into the infected wound to evaluate whether or not Vicryl $plus^{(R)}$ (Ethicon, USA) is effective to nosocomial bacteria using a zone of inhibition assay. Methods: We did a comparison of Vicryl $plus^{(R)}$ suture (with triclosan) size 2-0, 5-0 with $Vicryl^{(R)}$ suture (without triclosan) size 4-0 each as treatment and control group, applied in Mueller-Hinton agar infected by following mircroorganisms: Methicillin-sensitive $Staphylococcus$ $aureus$ (MSSA), Methicillin-resistant $Staphylococcus$ $aureus$ (MRSA), Acinetobacter baumanii, $Escherichia$ $coli$, Enterobacter faecalis, Pseudomonas aeruginosa, Candida albicans. Cultures were made of the selected mircroorganisms, seeding the study strain in agar plates for 24 and 48-hour period in an oven at $37^{\circ}C$ followed by zone of inhibition assay. Results: Vicryl $plus^{(R)}$ group has demonstrated to create a zone of inhibition against MRSA, MSSA and $A.$ $baumanii$, but no effect on $E.$ $faecalis$, $P.$ $aeruginosa$, $C.$ $albicans$. Vicryl $plus^{(R)}$ suture size 2-0 also had antibactericidal effect while Vicryl $plus^{(R)}$ suture size 5-0 did not. $Vicryl^{(R)}$ group had no zones of inhibition showing colonization at all mircroorganisms. Conclusion: Our results seem to warrant the use of Vicryl $plus^{(R)}$ as absorbable buried suture when concerning SSIs as a prophylaxis against surgical nosocomial infection.

Iatrogenic Tracheal Posterior Wall Perforation Repaired with Bronchoscope-Guided Knotless Sutures Through Tracheostomy

  • Jung, Yong Chae;Sung, Kiick;Cho, Jong Ho
    • Journal of Chest Surgery
    • /
    • v.51 no.4
    • /
    • pp.277-279
    • /
    • 2018
  • A 68-year-old man presented with a posterior tracheal wall injury caused by percutaneous dilatational tracheostomy. The wound was immediately covered with an absorbable polyglycolic acid sheet. Ten days after the injury, the perforation was closed with knotless sutures using a Castroviejo needle-holder through the tracheostomy. The successful repair in this case indicates the feasibility of the knotless suture technique for perforations. The technique is described in detail in this report. The patient was weaned from the mechanical ventilator on postoperative day 25. In cases of posterior tracheal posterior wall perforation, every effort should be made to repair the perforation through an existing opening.