• Title/Summary/Keyword: absolute values

Search Result 789, Processing Time 0.03 seconds

The Accuracy of the Digital Imaging System and the Frequency Dependent Type Apex Locator in Root Canal Length Measurement (근관장 측정에 있어서 디지털 영상 처리기와 주파수 의존형 측정기의 정확도)

  • Lee Byaung-Rib;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.435-459
    • /
    • 1998
  • In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora/sup (R)/(digital imaging system) and Root ZX/sup (R)/(the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems. whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with #15, #20, #25 files by 3 different dentists each using the periapical radiography. Digora/sup (R)/ and Root ZX/sup (R)/. The measurements were then compared with the true length. The results were as follows: 1. In comparing mean discrepancies between measurements obtained by using periapical radiography(mean error: -0.449±0.444 mm), Digora/sup (R)/(mean error: -0.417±0.415 mm) and Root ZX/sup (R)/(mean error: 0.123±0.458 mm) with true length. periapical radiography and Digora/sup (R)/ system had statistically significant differences(p<0.05) in most cases while Root ZX/sup (R)/ showed none(p>0.05). 2. By subtracting values obtained by using periapical radiography, Digora/sup (R)/ and Root ZX/sup (R)/ from the true length and making a distribution table of their absolute values. the following analysis was possible. In the case of periapical film. 140 out of 261<53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm. 151 out of 261 (53,6%) were acceptable in the Digora/sup (R)/ system while Root ZX/sup (R)/ had 197 out of 261(75.5%) within the limits of 0.5mm margin of error. 3. In determining whether the thickness of files has any effect on measuring methoths, no statistically significant differences were found(p>0.05). 4. In comparing data obtained from these methods in order to evaluate the difference among measuring methods, there was no statistically significant difference between periapical radiography and Digora/sup (R)/ system(p>0.05), but there was statistically significant difference between Root ZX/sup (R)/ and periapical radiography(p<0.05). Also there was statistically significant difference between Root ZX/sup (R)/ and Digora/sup (R)/ system(p<0.05). In conclusion, Root ZX/sup (R)/ was more accurate when compared with the Digora/sup (R)/ system and periapical radiography and seems to be more effective clinically in determining root canal length. But Root ZX/sup (R)/ has its limits in determining root morphology and number of roots and its accuracy becomes questionable when apical foramen is open due to unknown reasons. Therefore the combined use of Root ZX/sup (R)/ and the periapical radiography are mandatory. Digora/sup (R)/ system seems to be more effective when periapical radiographs are needed in a short period of time because of its short processing time and less exposure.

  • PDF

Pharmacokinetics of Florfenicol and its Metabolite, Florfenicol Amine, in Broiler Chickens (육계에서의 플로르페니콜 및 그의 대사체인 플로르페니콜 아민의 약물동태학적 연구)

  • Park Byung-Kwon;Lim Jong-Hwan;Kim Myoung-Seok;Hwang Youn-Hwan;Yun Hyo-In
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.114-118
    • /
    • 2006
  • A study on bioavailability and pharmacokinetics of florfenicol was conducted in broilers following a single intravenous (i.v.) and oral (p.o.) doses of 20 mg/kg body weight (b.w.). Florfenicol concentrations in plasma were determined by a high-performance liquid chromatography/mass spectrometry. Plasma concentration-time data after i.v. administration were analyzed by a non-compartmental analysis. Following i.v. injection, the total body clearance was $0.74{\pm}0.25L/kg/h$ and the volume of distribution at steady-state was $1.16{\pm}0.19L/kg$. Florfenicol was rapidly distributed and eliminated following i.v. injection with $1.15{\pm}1.06h$ of elimination half-life. After oral administration, the calculated $C_{max}$ values ($8.18{\pm}0.97{\mu}g/mL$) were reached at $1.33{\pm}0.29h$ in broilers. The elimination half-life of florfenicol was $1.31{\pm}0.27h$ and the absolute bioavailability (F) was 75.46% after oral administration of florfenicol. Florfenicol amine, a major metabolite of florfenicol, was detected in all broilers after i.v. and p.o. administration of florfenicol. The observed $C_{max}$ values of florfenicol amine ($3.96{\pm}2.60\;and\;2.22{\pm}1.71{\mu}g/mL$) were reached at $0.16{\pm}0.19\;and\;1.61{\pm}1.02h$ after i.v. and p.o. administration of florfenicol, respectively. Florfenicol amine was eliminated with $1.88{\pm}0.39\;and\;2.64{\pm}1.39h$ of the elimination half-life after i.v. and p.o. administration of florfenicol, respectively.

Improved Activity Estimation using Combined Scatter and Attenuation Correction in SPECT (단일광자방출단층촬영 영상에서 산란 및 감쇠 보정에 위한 절대방사능 측정)

  • Lee, Jeong-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Seong-Wun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.382-390
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the accuracy of radioactivity quantitation in Tc-99m SPECT by using combined scatter and attenuation correction. Materials and Methods: A cylindrical phantom which simulates tumors (T) and normal tissue (B) was filled with varying activity ratios of Tc-99m. We acquired emission scans of the phantom using a three-headed SPECT system (Trionix, Inc.) with two energy windows (photopeak window: $126{\sim}154keV$ and scatter window: $101{\sim}123keV$). We performed the scatter correction with dual-energy window subtraction method (k=0.4) and Chang attenuation correction. Three sets of SPECT images were reconstructed using combined scatter and attenuation correction (SC+AC), attenuation correction (AC) and without any correction (NONE). We compared T/B ratio, image contrast [(T-B)/(T+B)] and absolute radioactivity with true values. Results: SC+AC images had the highest mean values of T/B ratios. Image contrast was 0.92 in SC+AC, which was close to the true value of 1, and higher than AC (0.77) or NONE (0.80). Errors of true activity by SPECT images ranged from 1 to 11% for SC+AC, $22{\sim}47%$ for AC, and $2{\sim}16%$ for NONE in a phantom which was located 2.4cm from the phantom surface. In a phantom located 10.0cm from the surface, SC+AC underestimated by 24%, NONE 40%. However, AC overestimated by 10%. Conclusion: We conclude that accurate SPECT activity quantitation of Tc-99m distribution can be achieved by dual window scatter correction combind with attenuation correction.

  • PDF

Environmental Change of High Moor in Mt. Dae-Am of Korean Peninsula (대암산 고층습원의 환경변천)

  • Yoshioka, Takahito;Kang, Sang-Joon
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.1 s.110
    • /
    • pp.45-53
    • /
    • 2005
  • The environmental change of Yong-nup in Mt. Dae-Am, which is located at the northern part of Kangwon-Do, Korea, was assesed with peat sedimentary carbon and nitrogen isotope analysis. The surface layer of the peat (0 ${\sim}$ 5 cm) was 190 year BP, and the middle layers (30 ${\sim}$ 35 cm and 50 ${\sim}$ 55 cm) were 870 year BP and 1900 year BP, respectively. Bulk sedimentation rate was estimated to be about 0.4 mm $year^{-1}$ for 0 cm to 30 cm and 0.15 mm $year^{-1}$ for 35 cm to 50 cm. The $^{14}C$ age of the bottom sediment (75 ${\sim}$ 80 cm) collected and measured in this study was about 1900 year BP, although it was measured that the $^{14}C$ of the lowest bottom sediment in Yong-nup was 4105 ${\pm}$ 175 year BP (GX-23200). Since the $^{14}C$ ages for 50 ${\sim}$ 55 cm and 75 ${\sim}$ 80 cm layers were almost the same as 1890 ${\pm}$ 80 fear BP (NUTA 5364) and 1850 ${\pm}$ 90 year BP (NUTA 5462), respectively, we have estimated that the deep layers (55 ${\sim}$ 80 cm) in the high moor were the original forest soil. The low organic C and N contents in the deeper layers supported the inference. The sediment of 50 ${\sim}$ 55 cm layer contains much sandy material and showed very low organic content, suggesting the erosion (flooding) from the surrounding area. In this context, the Yong-nup, high moor, of Mt. Dae-Am, might have developed to the sampling site at about 1900 year BP. The ${\delta}^{13}C$ values of organic carbon and the ${\delta}^{15}N$ values of total nitrogen in the peat sediments fluctuated with the depths. The profile of ${\delta}^{13}C$ may indicate that the Yong-nup of Mt. Dae-Am have experienced the dry-wet and cool-warm period cycles during the development of the high moor. The ${\delta}^{15}N$ may indicate that the nitrogen cycling in the Yong-nup have changed from the closed (regeneration depending) system to the open (rain $NO_3\;^-$ and $N_2$ fixation depending) system during the development of the high moor.

Palatability and Physicochemical Properties in 2001 Yield Increased by 10% than Normal Level in 2000 (쌀 수량이 평년수준인 2000년 대비 10% 증가한 2001년의 식미 및 이화학특성 비교)

  • Lee, Jeom-Sig;Lee, Jeong-Heui;Yoon, Mi-Ra;Kwak, Jieun;Mo, Young Jun;Chun, Areum;Kim, Chung-Kon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.58 no.3
    • /
    • pp.292-300
    • /
    • 2013
  • In this study, we examine the palatability and physicochemical properties of rice in the year, when there was 10% increase in yield compared to normal year due to daily temperature range and sunshine hours. The results of the analysis of rice yield over the last 20 years (1993-2012) showed 10% difference between the yield in 2000, which was normal, and that in 2001. With regard to the crop weather condition during the ripening period in 2001 compared to 2000, the daily range and sunshine hours were higher, but the mean temperature was similar. The rice yield in 2001 was 9.8% higher than that in 2000 due to the increased number of spikelets per panicles and ratio of ripened grain. In terms of chemical traits, protein, Mg, and K contents decreased in 2001 compared to 2000, but amylose content increased. Trough and final viscosity assessed with a Rapid Visco Analyser were significantly higher in 2001 than 2000. The quality of cooked rice was measured through the Toyo Mido Meter Glossiness Value (TGV) instead of a palatability score because a sensory test produces relative comparison values rather than absolute values. The correlation coefficients between the sensory evaluation parameters and the TGV in several rice materials harvested in two years showed a highly significant positive correlation ($r=0.81^{**}-0.89^{**}$, n=27-47). TGV was also significantly higher in 2001 than in 2000. The results suggested that the palatability of cooked rice was good in 2001 with about 10% increase in rice yield compared to normal year in 2000 due to daily temperature range and sunshine hours.

Risk Factors of Extubation Failure and Analysis of Cuff Leak Test as a Predictor for Postextubation Stridor (발관 실패의 위험 인자 및 발관 후 천음과 재삽관의 예측에 있어 Cuff Leak Test 의 유용성과 의미 분석)

  • Lim, Seong Yong;Suh, Gee Young;Kyung, Sun Yong;An, Chang Hyeok;Park, Jung Woong;Lee, Sang Pyo;Jeong, Sung Hwan;Ham, Hyoung Suk;Ahn, Young Mee;Lim, Si Young;Koh, Won Jung;Chung, Man Pyo;Kim, Ho Joong;Kwon, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.34-40
    • /
    • 2006
  • Background: Extubation failure was associated with poor prognosis and high hospital mortality. Cuff leak test (CLT) has been proposed as a relatively simple method for detecting laryngeal obstruction that predispose toward postextubation stridor (PES) and reintubation. We examined the risk factors of extubation failure and evaluated the usefulness and limitation of CLT for predicting PES and reintubation. Methods: Thirty-four consecutive patients intubated more than 24 hours were examined. The subjects were evaluated daily for extubation readiness, and CLT was performed prior to extubation. Several parameters in the extubation success and failure group were compared. The accuracy and limitation of CLT were evaluated after choosing the thresholds values of the cuff leak volume (CLV) and percentage (CLP). Results: Of the 34 patients studied, 6 (17.6%) developed extubation failure and 3 (8.8%) were accompanied by PES. The patients who had extubation failure were more likely to have a longer duration of intubation and more severe illness. The patients who developed PES had a smaller cuff leak than the others: according to the CLV ($22.5{\pm}23.8$ vs $233.3{\pm}147.1ml$, p=0.020) or CLP ($6.2{\pm}7.3$ vs $44.3{\pm}24.7%$, p=0.013). The best cut off values for the CLV and CLP were 50ml and 14.7%, respectively. The sensitivity, negative predictive value, and specificity of CLT were relatively high, but the positive predictive value was low. Conclusion: The likelihood of developing extubation failure increases with increasing severity of illness and duration of intubation. A low CLV or CLP (<50ml or 14.7%) is useful in identifying patients at risk of PES, but the CLT is not an absolute predictor and should not be used an indicator for delaying extubation.

Changes of Hemodynamic and Central Pulmonary Artery Dimension After Bidirectional Cavopulmonarv Shunt (양방향성 체정맥-폐동맥 단락술후 혈역학 및 중심 폐동맥 크기의 변화)

  • 이정렬;이해원
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1306-1315
    • /
    • 1996
  • This study reviewed the changes of hemodynamlcs and centrAl pulmonary artery dimension in 54 patients who underwent bidirectional cavopulmonary shunt(BCPS) between February 1992 and December 1995 at Seoul National University Childrell's Hospital. Ag and body weight of patients averaged 36.8 $\pm$ 37.7 months and 8.0$\pm$3.0 kg, respectively Eightynine percent of patients had more than 2 violations of the risk factors for Fontan operation, resulting overall hospital mortality of 16.6%(9154). Serial hemodynamic and anglographic examinations before and mean 16.3 $\pm$ 14.3 months iirter BCPS were compared. The arterial oxygen saturation improved from a preoperative value of 71 9: 10.1 % to 79.H $\pm$ 8. 5% (n:4), p<0.05). The values of arterial oxygen saturation were lower as the age of the patients with BCPS in place was older(n=22, R'=0.341, p=0.004). A mean pulmonary artery pressure and pulmonary vascular resistance reduced from 31 $\pm$17 to 1).5$\pm$3.SmmHg(n=22, p<0.05) and from ).2$\pm$2.1 to 2.3$\pm$2.7 unit (n=7. p>0.05), respectively. Follow-up study showed a significant Increase of absolute values of ipsilateral pulmoanry artery (n: 14, p<0.05), but no change of contralateral pulmonary artreries (n: 14. p=not significant(HSI). However, there w re significant decreases in diameters of both ipsilateral and contralateral pulmonary arteries standardized by patients' body surface areas(16.8% decrease, n: 14, p< 0. 05 for ipsilatreal, 25.1%, n=14, p<0.05 for contralateral). Pulmonary artery indices for cross sectional areas of both pulmonary arterises decreased 9.3 $\pm$ 13.8% with showing a trend of more decrease as the follow-up duration was longer, We conclude that the bidirectional cavopulmonary shunt provide an excellent.

  • PDF

The Effect of Rain on Traffic Flows in Urban Freeway Basic Segments (기상조건에 따른 도시고속도로 교통류변화 분석)

  • 최정순;손봉수;최재성
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.1
    • /
    • pp.29-39
    • /
    • 1999
  • An earlier study of the effect of rain found that the capacity of freeway systems was reduced, but did not address the effects of rain on the nature of traffic flows. Indeed, the substantial variation due to the intensity of adverse weather conditions is entirely rational so that its effects must be considered in freeway facility design. However, all of the data in Highway Capacity Manual(HCM) have come from ideal conditions. The primary objective of this study is to investigate the effect of rain on urban freeway traffic flows in Seoul. To do so, the relations between three key traffic variables(flow rates, speed, occupancy), their threshold values between congested and uncontested traffic flow regimes, and speed distribution were investigated. The traffic data from Olympic Expressway in Seoul were obtained from Imagine Detection System (Autoscope) with 30 seconds and 1 minute time periods. The slope of the regression line relating flow to occupancy in the uncongested regime decreases when it is raining. In essence, this result indicates that the average service flow rate (it may be interpreted as a capacity of freeway) is reduced as weather conditions deteriorate. The reduction is in the range between 10 and 20%, which agrees with the range proposed by 1994 US HCM. It is noteworthy that the service flow rates of inner lanes are relatively higher than those of other lanes. The average speed is also reduced in rainy day, but the flow-speed relationship and the threshold values of speed and occupancy (these are called critical speed and critical occupancy) are not very sensitive to the weather conditions.

  • PDF

Melanogenesis regulatory constituents from Premna serratifolia wood collected in Myanmar

  • WOO, SO-YEUN
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.04a
    • /
    • pp.21-22
    • /
    • 2019
  • Melanin is a mixture of pigmented biopolymers synthesized by epidermal melanocytes that determine the skin, eye, and hair colors. Melanocytes produce two different kinds of melanin, eumelanin (dark brown/black insoluble pigments found in dark skin and dark hair and pheomelanin (lighter red/yellow). The biological role of melanin is to prevent skin damage by ultraviolet (UV) radiation. However, the overproduction or deficiency of melanin synthesis could lead to serious dermatological problems, which include melasma, melanoderma, lentigo, and vitiligo. Therefore, regulating melanin production is important to prevent the pigmentation disorders. Myanmar has a rich in natural resources. However, the chemical constituents of these natural resources in Myanmar have not been fully investigated. In the effort to search for compounds with anti-melanin deposition activity from Myanmar natural resources, five plants were collected in Myanmar. Extracts of these collected five plants were tested for anti-melanin deposition activity against a mouse melanoma cell line (B16-F10) induced with ${\alpha}$-melanocyte-stimulating hormone (${\alpha}$-MSH) and 3-isobutyl-1-methylxanthine (IBMX), and their anti-melanin deposition activities were compared with the positive control, arbutin. Among the tested extracts, the CHCl3 extracts of the Premna serratifolia (syn: P. integrifolia) wood showed anti-melanin deposition activities with IC50 values of $81.3{\mu}g/mL$. Hence, this study aims to identify secondary metabolites with anti-melanin deposition activity from P. serratifolia wood of Myanmar. P. serratifolia belongs to the Verbenaceae family and is widely distributed in near western sea coast from South Asia to South East Asia, which include India, Malaysia, Vietnam, Cambodia, and Sri Lanka. People in Tanintharyi region located in the southern part of Myanmar utilize the P. serratifolia, Sperethusa crenulata, Naringi crenulata, and Limonia acidissima as Thanaka, traditional cosmetics in Myanmar. Thanaka is applied in the form of paste onto skins to make it smooth and clear, as well as to prevent wrinkles, skin aging, excessive facial oil, pimples, blackheads, and whiteheads. However, the chemical constituents responsible for their cosmetic properties are yet to be identified. Moreover, the chemical constituents of P. serratifolia was almost uncharacterized. Investigation of the P. serratifolia chemical constituents is thus an attractive endeavor to discover new anti-melanin deposition active compounds. The investigation of the chemical constituents of the active CHCl3 extract of P. serratifolia led to isolation of four new lignoids, premnan A (1), premnan B (2), taungtangyiol C (3), and 7,9-dihydroxydolichanthin B (4), together with premnan C (5) (assumed to be an artifact), one natural newlignoid,(3R,4S)-4-(1,3-benzodioxol-5-ylcarbonyl)-3-[(R)-1-(1,3-benzo dioxol-5-yl)-1-hydroxy methyl]tetrahydro-2-furanone (6), and five known compounds (7-11)1,2). The structures of all isolated compounds were determined on the basis of their spectroscopic data and by comparison with the reported literatures. The absolute configurations of 1-3 and 5 were also determined by optical rotation and circular dichroism (CD) data analyses1). The anti-melanin deposition activities of all the isolated compounds were evaluated against B16-F10 cell line. 7,9-Dihydroxydolichanthin B (4) and ($2{\alpha},3{\alpha}$)-olean-12-en-28-oic acid (11) showed strong anti-melanin deposition activities with IC50 values of 18.4 and $11.2{\mu}M$, respectively, without cytotoxicity2). On the other hand, compounds 1-3, 5, and 7 showed melanogenesis enhancing activities1). To better understand their anti-melanin deposition mechanism, the effects of 4 and 11 on tyrosinase activities were investigated. The assay indicated that compounds 4 and 11 did not inhibit tyrosinase. Furthermore, we also examined the mRNA expression of microphthalmia-associated transcription factor (MITF), tyrosinase (TYR), tyrosinase-related protein-1 (TRP-1), and tyrosinase-related protein-2 (TRP-2). Compounds 4 and 11 down-regulated the expression of Tyr and Mitf mRNAs, respectively. Although the P. serratifolia wood has been used as traditional cosmetics in Myanmar for centuries, there are no scientific evidences to support its effectiveness as cosmetics. Investigation of the anti-melanin deposition activity of the chemical constituents of P. serratifolia thus provided insight into the effectiveness of the P. serratifolia wood as a cosmetic agent.

  • PDF

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.