• 제목/요약/키워드: absolute test

검색결과 667건 처리시간 0.032초

Evaluation of Characteristics and Useful Life of Rubber Spring for Railway Vehicle

  • Woo, Chang-Su;Park, Hyun-Sung;Park, Dong-Chul
    • International Journal of Railway
    • /
    • 제1권3호
    • /
    • pp.122-127
    • /
    • 2008
  • Rubber components are widely used in many application such as vibration isolators, damping, ride quality. Rubber spring is used in primary suspension system for railway vehicle. Characteristics and useful life prediction of rubber spring was very important in design procedure to assure the safety and reliability. Non-linear properties of rubber material which are described as strain energy function are important parameter to design and evaluate of rubber spring. These are determined by physical tests which are uniaxial tension, equi-biaxial tension and pure shear test. The computer simulation was executed to predict and evaluate the load capacity and stiffness for rubber spring. In order to investigate the useful life, the acceleration test were carried out. Acceleration test results changes as the threshold are used for assessment of the useful life and time to threshold value were plotted against reciprocal of absolute temperature to give the Arrhenius plot. By using the acceleration test, several useful life prediction for rubber spring were proposed.

  • PDF

암모니아의 수평관내 단상 및 응축 열전달계수의 측정 (Measurement of Single Phase and Condensation Heat Transfer Coefficients of Ammonia in a Horizontal Tube)

  • 백영진;장영수;김영일
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.561-569
    • /
    • 2000
  • Single phase and condensation heat transfer characteristics of ammonia in a horizontal tube have been investigated experimentally The horizontal test section is composed of smooth SUS316 tube for refrigerant flow, surrounding annulus for water flow, and temperature and Pressure measuring sensors. For single phase test, subcooled ammonia mass flux was varied from 320 to 501 kg/mrs and temperature was varied from 18 to $47^{\circ}C$. For condensation test, mass flux and saturation temperature were varied from 86 to 128 kg/$m^2$s and 34 to $47^{\circ}C$, respectively. The equations of Gnielinski Soliman et al., Traviss et at., Cavallini and Zecchin, Shah, Chen et al., Tandon et al., and Chilli and Anand were compared with the experimental data. New correlations are proposed based on the experimental results and the absolute mean deviation of the experimental data becomes 1.0% for single phase test and 4.9% for condensation test.

  • PDF

동적 지반강성을 갖는 지반-구조물계의 실시간 하이브리드 진동대 실험 (Real-Time Hybrid Shaking Table Test of a Soil-Structure Interaction System with Dynamic Soil Stiffness)

  • 이성경;민경원
    • 한국전산구조공학회논문집
    • /
    • 제20권2호
    • /
    • pp.217-225
    • /
    • 2007
  • 본 연구에서는 건물모델만을 물리적인 실험체로 이용하여 동적 지반강성을 갖는 지반-구조물계의 동적거동을 모사하기 위한 하이브리드 진동대 실험법을 제안하고 이를 실험적으로 검증하였다. 본 연구에서 제안되는 실험방법은 상부구조물과 진동대의 가속도를 계측하여 진동대 제어기로 피드백하고, 전체 지반-구조물계의 동적거동을 묘사하기 위해 요구되는 기초부분의 절대가속도 응답(가속도 피드백 방법) 또는 절대속도 응답(속도 피드백 방법)을 계산하여 진동대를 구동시키는 방법이다. 지반부분을 계산하기 위해서 이론적인 동적지반강성을 제안방법에 따라서 다르게 근사화하여 진동대 제어기에 반영함으로써 실험을 수행하였다. 기초 고정계 모델에 대한 실험으로부터 계측된 응답과 본 논문에서 가정한 지반-구조물 계에 대한 실험으로부터 측정된 응답을 비교하고, 진동대 제어기에 반영한 동적지반강성과 실험데이터를 이용하여 식별된 동적지반강성을 비교함으로써 본 논문에서 제안된 실험방법의 유효성을 검증하였다.

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

  • von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.100-106
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.

고속 금형가공센터 구조물의 강성평가에 관한 연구 (A Study on the Static and Dynamic Stiffness Evaluation of a High Speed Mold/Die Machining Center Structure)

  • 최영휴;강영진;차상민;김태형;박보선;최원선
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.102-106
    • /
    • 2003
  • An experimental modal analysis and dynamic stiffness evaluation of a moving body structure of a high speed machining center are presented in this paper. The natural frequencies and corresponding modes, and dynamic compliance of a moving body structure of high speed machining center are investigated by using F.E.M., hydraulic exciter test, and impulse hammer test. The lowest three natural frequencies were found to be 56.6 Hz, 112.7 Hz, and 142.7 Hz by FEA respectively, while those were 55 Hz, 112 Hz, 131 Hz by experimental analysis. Furthermore, both computed and measured absolute dynamic compliances of the moving body structure in iso-direction showed good agreement especially at the first two mode frequencies. With our experimental data, the dynamic characteristics of the machining center can be exploited to get a new development of structural dynamic design and modification.

  • PDF

Steering Control of the Autonomous Guided Vehicle Driving System for Durability Test

  • Jeong, Jong-Won;Lee, Young-Jin;Yoon, Kang-Sup;Lee, Man-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.104-104
    • /
    • 2000
  • Among durability tests, the accelerated durability test has been widely used to evaluate the durability of vehicle structure and chassis pans in a shon period of time on the designed road which has severe surface conditions. However it increases the drivers fatigue mainly caused by the severe driving conditions. The drivers difficulty of maintaining constant speed and controlling the steering wheel reduces the reliability of test results. The durability test includes the position and distance sensing system for the recognition of the absolute and relative driving position, the driving control system for the control of whole driving circumstance, the emergency system for responding to system errors. AGVDS (Autonomous Guided Vehicle Driving System) was Proved to facilitate the development of now car projects. Therefore the AGVDS we propose will help make the fundamentals for all future traffic systems.

  • PDF

가속 열노화시험을 통한 레일패드 사용수명예측 (Useful lifetime prediction of rail-pad by using the accelerated heat aging test)

  • 우창수;박현성;최병익;양신추;장승엽;김은
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1010-1015
    • /
    • 2009
  • Rail-pad is an important and readily replaceable component of a railway track, as it is the elastic layer between the rail and the sleeper. Characteristics and useful lifetime prediction of rail-pad was very important in design procedure to assure the safety and reliability. In order to investigate the useful lifetime, the accelerate test were carried out. Accelerated test results changes as the threshold are used for assessment of the useful life and time to threshold value were plotted against reciprocal of absolute temperature to give the Arrhenius plot. By using the acceleration test, several useful lifetime prediction for rail-pads were proposed.

  • PDF

강박장애 및 조현병 환자에서의 정량뇌파 소견과 신경인지기능 간의 연관성 (Correlation between Quantitative Electroencephalogram Findings and Neurocognitive Functions in Patients with Obsessive-Compulsive Disorder and Schizophrenia)

  • 김서영;신정은;김민주;권준수;최수희
    • 생물정신의학
    • /
    • 제23권4호
    • /
    • pp.193-198
    • /
    • 2016
  • Objectives Obsessive-compulsive disorder (OCD) and schizophrenia have many common clinical and neurocognitive features. However, not all of them share the same underlying mechanism. The aim of this study was to discover evidences that indicate a pathophysiological mechanism specific to OCD by comparing correlations of quantitative electroencephalography (QEEG) patterns and neurocognitive function in patients with OCD and schizophrenia. Methods Resting-state QEEG data of total 265 patients were acquired retrospectively and parameters such as absolute power, relative power and peak frequency were analyzed from the data. Stroop test and Trail Making Test results as well as demographic features were reviewed for this study. The correlation of neurocognitive functions and brain electrical activities in each group were assessed and compared by correlation analysis. Results Compared with the OCD group, the schizophrenia group performed poorly in neurocognitive tests. Mean values of QEEG parameters in patients with OCD and schizophrenia did not show significant differences. Both absolute and relative power of alpha rhythm in central and frontal regions showed significant positive correlation with Stroop test results in OCD patients. Conclusions Findings in this study shows distinctive correlations between frontal executive dysfunction and frontal alpha rhythm in the OCD patients, both of which might be a candidate for endophenotype underlying obsessive rumination.

HMC05의 Sprague-Dawley 흰쥐를 이용한 4주 반복 경구투여 DRF 독성시험 (Repeated Dose 4-Week Oral-Treatment for DRF Toxicity Test of HMC05 in Sprague-Dawley Rats)

  • 신흥묵
    • 대한한의학회지
    • /
    • 제30권5호
    • /
    • pp.102-114
    • /
    • 2009
  • Objectives: HMCO5 is an extract obtained from 8 different herbal mixtures. We undertook a safety evaluation of HMCO5 for a dose range finding (DRF) toxicity test in specific pathogen free (SPF) Sprague-Dawley (SD) male and female rats. Methods: The male and female rats were divided into 4 groups, respectively; G(0), treated with distilled water: G(1), treated with 222 mg/kg HMC05: G(2), treated with 667 mg/kg HMC05, and G(3), treated with 2,000 mg/kg HMC05; HMC05 was administered orally for 4 weeks. The safety evaluation examined clinical signs, mortality, body weight, food consumption, water consumption, ophthalmic findings, urinalysis, hematological values, absolute & relative organ weights, and necropsy findings during the tests. Results: There were no changes in clinical signs, mortality, body weight, food consumption, water consumption, and ophthalmic findings examined during the test periods. In serum biochemical values, triglyceride was increased in male group G(3) and Na$^+$ decreased significantly in male groups G(2), G(3) and G(4). In male group G(4), spleen weight decreased relatively and increases of absolute & relative left ovary weights were found. In addition, an adhesion of liver to diaphragm was found in male group G(2). However, we could not find any dose-interrelationships in these changes. Conclusions: These results indicate that HMC05 extract did not show any toxicity in the DRF toxicity study. Therefore, it suggests that establishment of 1,000, 333 and 111 mg/kg dosages are moderate in a repeated dose 26-week oral toxicity study of HMC05.

  • PDF

청각 및 후각자극에 의한 뇌파(EEG)와 진동이미지기술의 상관성 분석에 관한 연구 (A Study on the Correlation Analysis of EEG and Vibraimage due to Auditory and Olfactory Stimulation)

  • 김정민;김명호
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.4291-4297
    • /
    • 2015
  • 실내공간에서 인간의 쾌적감 및 불쾌적감 등의 감성을 측정하기 위하여 뇌파(EEG)측정을 많이 사용하고 있으나, 뇌파(EEG)측정은 접촉식으로써 실험에 제한적이다. 그러나 진동이미지기술은 웹캠 카메라를 이용하여 인간의 감성을 측정할 수 있는 비접촉식 방법으로써 실내공간에 적용하기에 적합하다고 판단된다. 따라서 인간의 감성을 측정할 수 있는 접촉식인 뇌파(EEG)와 비접촉식인 진동이미지기술의 상관변수를 도출하고자 한다. 본 연구에서는 소리크기 60[dB] 및 90[dB]과 로즈마리 및 쟈스민 향기에 대한 피험자의 뇌파(EEG)와 진동이미지기술의 상관분석을 하였다. 피험자는 건강상태를 점검하여 대학생 남자 3명으로 선별하여 10회 반복 실험하였고, 실험기간은 약 한 달간 진행되었으며, 측정실의 조건은 온도 25[$^{\circ}C$], 상대습도 50[%], 조도 1.000[lux] 및 기류속도 0.02[m/sec]로 하였다. 뇌파(EEG) 23가지 지표(절대${\theta}$, 상대${\theta}$, 절대$S{\alpha}$, 상대$S{\alpha}$, 절대${\alpha}$, 상대${\alpha}$, 절대${\beta}$, 상대${\beta}$, 절대$\gamma$, 상대$\gamma$, 절대$F{\alpha}$, 상대$F{\alpha}$, 절대SMR, 상대SMR, $SMR/{\theta}$, $SMR+M{\beta}/{\theta}$, 절대$H{\beta}$, 상대$H{\beta}$, $H{\beta}/{\alpha}$, 절대$M{\beta}$, 상대$M{\beta}$, SEF50, ASEF50)와 진동이미지기술 10가지 지표(긴장/불안, 억제, 신경과민증, 밸런스, 매력, 자신감, 의심, 스트레스, 공격성, 에너지)를 상관 분석한 결과 뇌파(EEG)의 상대${\gamma}$파와 진동이미지기술의 신경과민증 지표가 (${\pm}$).414와 (${\pm}$).424로 높은 정적상관관계로 분석되었다.