• 제목/요약/키워드: absolute test

검색결과 662건 처리시간 0.028초

Relative SATD-based Minimum Risk Bayesian Framework for Fast Intra Decision of HEVC

  • Gwon, Daehyeok;Choi, Haechul
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권1호
    • /
    • pp.385-405
    • /
    • 2019
  • High Efficiency Video Coding (HEVC) enables significantly improved compression performance relative to existing standards. However, the advance also requires high computational complexity. To accelerate the intra prediction mode decision, a minimum risk Bayesian classification framework is introduced. The classifier selects a small number of candidate modes to be evaluated by a rate-distortion optimization process using the sum of absolute Hadamard transformed difference (SATD). Moreover, the proposed method provides a loss factor that is a good trade-off model between computational complexity and coding efficiency. Experimental results show that the proposed method achieves a 31.54% average reduction in the encoding run time with a negligible coding loss of 0.93% BD-rate relative to HEVC test model 16.6 for the Intra_Main common test condition.

삼차원 좌표 측정을 위한 부피 간섭계의 오차분석 및 성능평가 (Error analysis and Performance test of the Volumetric interferometer for Absolute distance measurement)

  • 이혁교;주지영;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2002
  • In this paper, we accomplish uncertainty evaluation and performance test of the volumetric interferometer using two spherical wavefronts emitted from the ends of two single mode fibers. We verify that the volumetric interferometer has the volume uncertainty of 690nm through the error analysis and it has the resolution of 0.1 0.1$\mu\textrm{m}$ for x axis which is the same order of repeatability for x axis. Also, we obtain the systematic error of $1\mu\textrm{m}$ for $60\times 60\times 20 mm^3$ working volume using self-calibration with an artifact plate.

  • PDF

무수 알코올에 의한 내장신경차단에 관한 임상적 연구 (A Clinical Evaluation of Splanchnic Nerve Block with Absolute Ethanol)

  • 이효근;윤덕미;오흥근
    • The Korean Journal of Pain
    • /
    • 제4권2호
    • /
    • pp.111-121
    • /
    • 1991
  • It has been well known that the splanchnic nerve block is effective for patients who suffer from intractable upper abdominal pain. However, it is unclear whether the effect of the splanchnic nerve block depends on varied alcoholic concentration. In this study, an attempt was made to use absolute ethanol on patients who recieved a splanchnic nerve block at Severance Hospital during the period from September l990 to April l991. The results are as follows; 1) Among the 33 patients, including 22 males and 1l females, the fifties and sixties were the major age groups. 2) Stomach cancer was the most common underlying disease(13 cases), with pancreatic can- cer next(9 cases). 3) The main locations of pain were the upper abdomen, epigastrium, and entire abdomen in decreasing order. 4) There were 17 cases who had had chemotherapy, and 1l cases of whom had had surgery before the splanchnic nerve block. 5) The volume of alcohol used was 12 ml bilaterally. 6) Among the 33 patients, 15.2% required a second block within two weeks of the first block. One case required a third block. 7) The most common complications of splanchnic nerve block were hypotension(33.3%), occasional transient sharp burning pain, flushing of face, pain on injection site, nausea, vomiting, dyspnea, chest discomfort and diarrhea. 8) The supplemental block most commonly used was a continuous epidural block. It was used both as a diagnostic block and to afford relief from pain before the splanchnic nerve block was done. 9) The interval between the receiving the absolute ethanol block and discharge was within 2 weeks in l5 cases. But, in the patients with poor general health, the interval between the splanchnic nerve block and discharge prolonged. The above results suggest that bilateral splanchnic nerve block done with absolute ethanol after an effective test block with 1% lidocaine under C-arm fluroscopic control is satisfactory and reliable. Still, 26.6% of the patients received a repeat block within 2 weeks. Insufficient spread of ethanol due to its small volume seems to be a major factor in the repeat block. Minimizing the incidence of repeat block remains a problem to be solved.

  • PDF

Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown

  • Ji, Min-Kyung;Park, Ji-Hee;Park, Sang-Won;Yun, Kwi-Dug;Oh, Gye-Jeong;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.271-277
    • /
    • 2015
  • PURPOSE. This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. MATERIALS AND METHODS. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau$^{(R)}$Zirconia and ZENOSTAR$^{(R)}$ZR translucent) and lithium disilicate glass ceramic (IPS e.max$^{(R)}$press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. RESULTS. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max$^{(R)}$press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). CONCLUSION. The lithium disilicate glass ceramic crown (IPS e.max$^{(R)}$press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR$^{(R)}$ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max$^{(R)}$press) had overextended margins.

초음파 음속 및 경도법에 의한 발전소 고온배관재의 크리프 손상평가 (Creep Damage Evaluation of High-Temperature Pipeline in Power Plant by Using Ultrasonic Velocity Measurement and Hardness Test)

  • 허광범;유근봉;조용상;이상국
    • 한국해양공학회지
    • /
    • 제13권3호통권33호
    • /
    • pp.92-99
    • /
    • 1999
  • High temperature and pressure materials in power plant are degraded by creep damage, if they are exposed to constant loads for long times, which occurs in load bearing structures of pressurized components operationg at elevated temperatures. Many conventional measurement techniques such as replica method, electric resistance method, and hardness test method for measuring creep damgage have been used. So far, the replica method is mainly used for the inspection of high temperature and pressure components. This technique is, however, restricted to applications at the surface of the testpieces and cannot be used to material inside. In this paper, ultrasonic evaluation for the detection of creep damage in the form of cavaties on grain boundaries or intergranular microcracks were carried out. And the absolute measuring method of quantitative ultrasonic velocity technique for Cr-Mo material degradation was analyzed. As a result of ultrasonic tests for crept for specimens, we founded that the sound velocity was decreased as increase of creep life fraction(${phi}c$) and also, confirmed that hardness was decreased as increase of creep life fraction(${phi}c$).

  • PDF

요부 안정화운동이 요통환자의 요추부 기능개선에 미치는 영향 (The Effects of Lumbar Stabilization Exercise for Spinal Function in Patients with Low Back Pain)

  • 양승훈
    • 대한물리치료과학회지
    • /
    • 제13권1호
    • /
    • pp.39-52
    • /
    • 2006
  • The purpose of this study was to investigate the effects of lumbar stabilization exercise therapy on low back pain patients' lumbar spinal function. Identify the effect of stabilization exercise therapy, this study attempted to determine lumbar spinal functions, using spinoscopy, for 20 patients with low back pain This study applied lumbar stabilization exercise to 20 low back pain patients without a control group for 8 weeks and 4 times a week, and examined their spinal functions before and after the application. Data collected from the test were analyzed using Wilcoxon signed ranked test, a nonparametric test. Absolute index, functionality and performance increased significantly compared to them before treatment. FE loads and velocity control while conducting exercise tasks increased significantly compared to them before treatment. Test item ROL and ROM, which indicate the change of angle, both showed significant differences. Of stiff spine, stiff pelvic score and sprain score, which indicate the effects of the conduct of exercise tasks on the movement of the spine, stiff spine score and sprain score showed significant differences. According to the results as presented above, lumbar stabilization exercise may be greatly helpful in improving low back pain patients' lumbar spinal functions.

  • PDF

의약품 함량분석 정도관리에서의 변이 요인에 대한 통계분석 (Statistical Analysis on the Sources of Variance in Proficiency Test of Quantitative Analysis of Medicines)

  • 조정환
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권1호
    • /
    • pp.27-37
    • /
    • 2007
  • Proficiency test is an essential tool far ensuring analytical ability of analytical chemists and analytical institutes. Usually, the standard protocol for proficiency test is focused on acceptability of reported analytical results of participants by calculating z-scores and related diagnostic parameters. The ultimate goal of this process is to reveal the sources of variability of analytical results and to find the way to reduce their influence. In this study, the method of analysis of variance (ANOVA) was applied to the analytical data collected from qualify control departments of pharmaceutical companies in KyungIn province in Korea in the year of 2000. As influencing factors of variability of analytical results, the use of internal standards for liquid and gas chromatograpy, the educational and professional background of participants, geological locations and yearly production sizes of participating companies were evaluated. To evaluate the variability in accuracy of analytical results, absolute differences from sample mean and sample median were used and to evaluate variability in precision of individual participants, the reported standard deviation of each participant was used. As a result, the use of internal standards in gas chromatographic analysis, participants' academic background and the yearly production sizes of pharmaceutical companies showed statistically significant influence to the accuracy and the precision of the reported analytical results used in this study.

초음파에 의한 발전소 고온배관재료의 크리프손상 평가 (Creep Damage Evaluation of High-Temperature Pipeline Material for Fossil Power Plant by Ultrasonic Test Method)

  • 이상국;정민화
    • 한국해양공학회지
    • /
    • 제13권2호통권32호
    • /
    • pp.99-107
    • /
    • 1999
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operationg conditions which are high temperature and high pressure for an extended period time. Such material degradation leads to various component failures causing serious accidents at the plants. Conventional measurement techniques such as replica method, electric resistance method, and hardness test method have such disadvantages as complex preparation and measurement procedures, too many control parameters, and therefore, low practicality and they were applied only to component surfaces with good accessibility. In this paper, artificial creep degradation test and ultrasonic measurement for their creep degraded specimens have been carried out for the purpose of evaluation for creep damage which can occur in high-temperature pipeline of fossil power plant. Absolute measuring method of quantitative ultrasonic measurement for material degradation was established, and long term creep degradationtests using life prediction formula were carried out. As a result of ultrasonic tests for crept specimens, we confirmed that the sound velocity decreased and the attenuation coefficient linearly increased in proportion to the increase of creep fractiin(${\phi}$c).

  • PDF

Dynamic Behaviors of Skewed Bridge with PSC Girders Wrapped by Steel Plate

  • Rhee, In-Kyu;Kim, Lee-Hyeon;Kim, Hyun-Min;Lee, Joo-Beom
    • International Journal of Railway
    • /
    • 제3권3호
    • /
    • pp.83-89
    • /
    • 2010
  • This paper attempts to extract the fundamental dynamic properties, i.e. natural frequencies, damping ratios of the 48 m-long, $20^{\circ}$ skewed real bridge with PSC girders wrapped by a steel plate. The forced vibration test is achieved by mounting 12 Hz-capacity of artificial oscillator on the top of bridge deck. The acceleration histories at the 9 different locations of deck surface are recorded using accelerometors. From this full-scaled vibration test, the two possible resonance frequencies are detected at 2.38 Hz and 9.86 Hz of the skewed bridge deck by sweeping a beating frequency up to 12 Hz. The absolute acceleration/energy exhibits much higher in case of higher-order twist mode, 9.86 Hz due to the skewness of bridge deck which leads asymmetric situation of vibration. This implies the test bridge is under swinging vertically in fundamental flexure mode while the bridge is also flickered up and down laterally at 9.86 Hz. This is probably by asymmetric geometry of skewed deck. A detailed 3D beam-shell bridge models using finite elements are performed under a series of train loads for modal dynamic analyses. Thereby, the effect of skewness is examined to clarify the lateral flickering caused by asymmetrical geometry of bridge deck.

  • PDF

경비행기의 상승 비행시험에 대한 연구 (A Study on the Climb Flight Test of Light Airplane)

  • 이정훈;최병철
    • 한국항공우주학회지
    • /
    • 제35권4호
    • /
    • pp.308-315
    • /
    • 2007
  • 연구는 경비행기인 창공-91의 인증 획득을 위한 비행시험의 일부로서 상승성능을 파악하기 위하여 수행되었다. 창공-91은 1993년에 대한민국의 건설교통부로부터 최초로 인증을 취득한 단발엔진을 장착한 일반유형의 5인승 항공기이다. 상승을 위한 비행시험 절차 및 자료는 형식증명을 획득하는데 사용되었다. 톱니형 상승 데이터로부터 양항곡선방법으로 데이터를 처리하여 창공-91의 최대상승률, 최대상승각 속도, 최대상승률 속도, 그리고 절대상승한도를 구하였다. 또한, 상승성능의 결과로부터 양항곡선식을 구함으로써 형상항력계수와 오스왈드 효율계수를 비행기 설계시의 값과 비교하였다.