• Title/Summary/Keyword: absolute test

Search Result 651, Processing Time 0.021 seconds

Absolute Temperature Measurement using White Light Interferometry

  • Kim, Jeong-Gon
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.89-93
    • /
    • 2000
  • Recently a new signal processing algorithm for white light interferometry was presented. In this paper, the proposed signal processing algorithm was applied for absolute temperature measurement using white light interferometry. Stability testing and absolute temperature measurement were demonstrated. Stability test demonstrated the feasibility of absolute temperature measurement with an accuracy of 0.015 fringe. The test also showed that the absolute temperature measurement system using white light interferometry is capable of obtaining the theoretical minimum detectable change (0.0005 fringe), which is consistent with the performance predicted by the proposed signal processing algorithm.

Development of Designing and Performing Procedure for Well Test in Coalbed Methane(CBM) Reservoir (석탄층 메탄가스 저류층의 유정생산시험 설계 및 수행절차 수립연구)

  • Park, Jinyoung;Lee, Jeonghwan
    • Economic and Environmental Geology
    • /
    • v.46 no.4
    • /
    • pp.279-289
    • /
    • 2013
  • The most critical factor in developing coalbed methane(CBM) reservoir is absolute permeability. Both productivity and economics of the CBM depend on the absolute permeability. The methods to estimate it are core analysis and well test. However, absolute permeability determined by core analysis cannot be a good representative of CBM reservoir. Therefore, it is generally estimated by well test. In this study, well test methods applicable of CBM reservoir were classified with their characteristics. Merits and demerits of each well tests were also analyzed. Based on those parameters, design considerations and procedures of well test were derived. After each well tests was performed, the procedure of well test interpretations to estimate reservoir properties such as absolute permeability and skin factor was presented.

Weighted Least Absolute Error Estimation of Regression Parameters

  • Song, Moon-Sup
    • Journal of the Korean Statistical Society
    • /
    • v.8 no.1
    • /
    • pp.23-36
    • /
    • 1979
  • In the multiple linear regression model a class of weighted least absolute error estimaters, which minimize the sum of weighted absolute residuals, is proposed. It is shown that the weighted least absolute error estimators with Wilcoxon scores are equivalent to the Koul's Wilcoxon type estimator. Therefore, the asymptotic efficiency of the proposed estimator with Wilcoxon scores relative to the least squares estimator is the same as the Pitman efficiency of the Wilcoxon test relative to the Student's t-test. To find the estimates the iterative weighted least squares method suggested by Schlossmacher is applicable.

  • PDF

Goodness of Fit and Independence Tests for Major 8 Companies of Korean Stock Market (한국 주식시장 상위 8개사에 대한 적합도 검정 및 독립성 검정)

  • Min, Seungsik
    • The Korean Journal of Applied Statistics
    • /
    • v.28 no.6
    • /
    • pp.1245-1255
    • /
    • 2015
  • In this paper, we investigated the major 8 companies of Korean stock market, and carried out the goodness of fit and independence tests. We found out the distributions of absolute returns are closed to compressed exponential distribution. The parameters are dominant that 1 < ${\beta}$ < 2, followed by ${\beta}=1$(exponential distribution) and ${\beta}=2$(normal distribution). Meanwhile, we assured that most of the absolute returns for major 8 companies have relevance to each other by chi-square independence test.

Secondary Current Range Extension of Current Transformers by Using Two Different Current Transformers and Absolute Evaluation Technique (전류변성기 두 대와 절대 평가 기술을 이용한 2차 전류 범위 확장)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.72-78
    • /
    • 2009
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

The Relative·Absolute Reliability and Validity of Step Test in Patients with Chronic Stroke (만성 뇌졸중 환자들의 Step Test의 상대적·절대적 신뢰도와 타당도)

  • Lee, Byoungkwon;Choi, Hyunsoo;An, Seungheon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.1
    • /
    • pp.43-53
    • /
    • 2017
  • Purpose : To examine the relative absolute reliability and validity of step test (ST) scores in subjects with chronic stroke. Method : A total of 27 stroke patients, participated in the study. A relative reliability index (intraclass correlation coefficient, ICC) was used to examine the level of agreement of inter-rater test-retest reliability for ST score. Absolute reliability indices, including the standard error of measurement(SEM) and the minimal detectable change (MDC), and limits of agreement by Bland and Altman analysis. The validity was demonstrated by spearman correlation of ST score with 10 m Walk Test (10mWT), Fugl-Meyer Assessment-Lower/Extremity (FMA-L/E)-total score, Berg Balance Scale (BBS)-total score. Result : An excellent inter-rater reliability in ST scores was found (paretic, ICC=0.993~0.996; nonparetic, ICC=0.982~0.991). In addition, excellent test-retest reliability was found (paretic, ICC=0.992; nonparetic, ICC=0.967). It all showed acceptable SEM of the ST score as paretic and nonparetic were 0.22 and 0.46 respectively (average score <10 %), and the MDC of the paretic and nonparetic were 0.61 and 1.27 respectively (possible highest score <20 %). indicating that measures had a small and acceptable measurement error. The ST score of paretic and nonparetic were also found to be significantly associated with 10MWT (r=0.77~0.79), FMA-LE scores (r=0.73~0.81) and BBS scores (r=0.72~0.76). Conclusion : The ST showed highly sufficient Inter-rater test-retest agreement and validity and acceptable measurement errors caused by due to chance variation in measurement. It also can be used by clinicians and researchers to assess the balance and mobility performance and monitor functional change in chronic stroke patients.

Prediction of Chest Deflection Using Frontal Impact Test Results and Deep Learning Model (정면충돌 시험결과와 딥러닝 모델을 이용한 흉부변형량의 예측)

  • Kwon-Hee Lee;Jaemoon Lim
    • Journal of Auto-vehicle Safety Association
    • /
    • v.15 no.1
    • /
    • pp.55-62
    • /
    • 2023
  • In this study, a chest deflection is predicted by introducing a deep learning technique with the results of the frontal impact of the USNCAP conducted for 110 car models from MY2018 to MY2020. The 120 data are divided into training data and test data, and the training data is divided into training data and validation data to determine the hyperparameters. In this process, the deceleration data of each vehicle is averaged in units of 10 ms from crash pulses measured up to 100 ms. The performance of the deep learning model is measured by the indices of the mean squared error and the mean absolute error on the test data. A DNN (Deep Neural Network) model can give different predictions for the same hyperparameter values at every run. Considering this, the mean and standard deviation of the MSE (Mean Squared Error) and the MAE (Mean Absolute Error) are calculated. In addition, the deep learning model performance according to the inclusion of CVW (Curb Vehicle Weight) is also reviewed.

Case study of a low head & kaplan turbine efficiency measurement using ASFM (절대유량법(ASFM)을 이용한 저낙차.카플란 수차효율측정 적용사례 연구)

  • Lee, Yongjun;Oh, Suegyoung;Shin, Changshik;Hyun, Jungjae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.205.1-205.1
    • /
    • 2011
  • This study concerns a low head and kaplan turbine efficiency measurement using the acoustic scintillation flow meter(ASFM). The ASFM is one of absolute discharge measurement methods because it measures velocity-area of discharge with couples of transducers. This study shows that the highest efficiency of turbine is 87.7% and the efficiency is 85.8% in the rated output(600kW). The test result is reliable because the efficiency trend from this test is similar to the result of index test conducted in 1986. In this paper, the principle, measurement methods, application and test procedures of the test are discussed.

  • PDF

Field Campaigns and test results for Absolute Radiometric Calibration (Absolute Radiometric Calibration을 위한 Field Campaign과 시험결과)

  • Lee, Seon-Gu;Kim, Yong-Seung
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.213-219
    • /
    • 2006
  • Korea Aerospace Research Institute(KARI) performed field campaigns for absolute radiometric calibration with overpassing of satellite Orbview-3 on Cal/ Val site in Goheung and Daejeon. The performed Cal/Val method is the reflectance-based of vicarious calibration methods. We collected ground-based and meteology data such as temperature, surface pressure and reflectance of targets, and radiosonde data only collected on Goheung. Data collected on each field served as input to radiative transfer codes to generate a top-of-atmosphere(TOA) radiance. Derived TOA is compared with DN of overpassing satellite Orbview-3 to calculate calibration coefficient of gain and offset. Also, This study proposed a proper method to prepare absolute radiometic calibration of KOMPSAT-2 by using experience of Field campaign.

  • PDF

The effects of knee joint position sense following local and general load protocols (국소적 부하와 전신적 부하가 슬관절 위치 감각에 미치는 영향)

  • Hwang, Yoon-Tae;Park, Rae-Joon;Choi, Jin-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.3
    • /
    • pp.429-440
    • /
    • 2005
  • The purpose of this study was to compare the effects of knee joint position sense following local and general load protocols in 25 healthy male subjects. Proprioception of the knee joint was evaluated by measuring absolute angular errors at matching angles before, after and between 2 different types of load protocols. Proprioception tests(on the dominant knee) were performed in which proprioception of the passivepassive reproduced and active-active reproduced knee position was measured. Local load was provided with maximum isokinetic knee extension-flexion on the isokinetic dynamometer(Cybex), and general load was 10 minutes running on a treadmill. Peak torque(knee extension and flexion) and heart rate(beats per minute) was evaluated as an indicator of local and general fatigue during load protocols. The results were as follows: 1. For pasive-pasive reproduced knee position test, significant difference in absolute angular errors after general load protocol was detected compared with that before general load protocol(P<.05), significant difference in absolute angular errors after local load protocol was detected compared with that before local load protocol(P<.05). However, no significant difference in absolute angular errors of general load protocol was detected compared with that of local load protocol (P>.05), no significant difference in absolute angular errors of local load protocol was detected compared with that of general load protocol(P>.05). 2. For active-active reproduced knee position test, significant difference in absolute angular errors after general load protocol was detected compared with that before general load protocol(P<.05), significant difference in absolute angular errors after local load protocol was detected compared with that before local load protocol (P<.05). Also, significant difference in absolute angular errors of general load protocol was detected compared with that of local load protocol(P<.05), significant difference in absolute angular errors of local load protocol was detected compared with that of general load protocol(P<.05). 3. A significant decrease of peak torque of knee extensors and flexors was seen after local load, although heart rate was significantly increased(P<.05). No significant change of peak torque of knee extensors and flexors was seen after general load(P>.05), although heart rate was also significantly increased(P<.05). The previous study revealed that knee proprioception is significantly altered when the muscle mechanoreceptors are dysfunctional due to muscle fatigue, although the joint mechanoreceptors have no significantly effect on knee proprioception when the presence of knee muscle fatigue. However, the results of this study are different from those of the previous study in that muscle weakness of the knee could not be seen after general load. This study shows that general load may diminish motor control by the central nervous system. Proprioceptional decline without muscle weakness of knee after general load suggests a change in the proprioceptional pathway without influence from muscle mechanoreceptors.

  • PDF