• 제목/요약/키워드: absolute distance

Search Result 275, Processing Time 0.024 seconds

Study About the Capstone Design Education for the Growth of Local Design Industries - Based on the Exhibitional Project, 'Jeju Tamranun Idea' (지역디자인 산업발전을 위한 캡스톤 디자인교육 사례연구 - '제주 탐라는아이디어전'을 중심으로)

  • Kim, Jong-Min
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.6
    • /
    • pp.653-662
    • /
    • 2021
  • This is a thesis about the whole process of cooperative study for the project, 'Jeju Tamranun idea' which produced by Capstone Design Class in communication design Dept, Hongik University. The purpose of this thesis is to know the primary educational goal and essence of capstone design class and to find the enhancement plan for the local design industry. The exhibitional project, 'Jeju Tamranun idea' was operated three times by hongik university with the company based on Jeju from 2017 to 2019. After the research, There are three positive effects of this project which are the new social function of the discarded assignments, the improvement of educational standard through the autonomous competition, and the growth of students' social consciousness in the process of considering local industries. And there are several points to be reviewed for a better capstone design class with local design industries. It is necessary to utilize the untact system for solving distance issues. And also, absolute evaluations, giving equal reward, and copyright protection are needed. Lastly, the continuous development of the curriculum to improve local design industries is needed.

K-Means Clustering Algorithm and CPA based Collinear Multiple Static Obstacle Collision Avoidance for UAVs (K-평균 군집화 알고리즘 및 최근접점 기반 무인항공기용 공선상의 다중 정적 장애물 충돌 회피)

  • Hyeji Kim;Hyeok Kang;Seongbong Lee;Hyeongseok Kim;Dongjin Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.6
    • /
    • pp.427-433
    • /
    • 2022
  • Obstacle detection, collision recognition, and avoidance technologies are required the collision avoidance technology for UAVs. In this paper, considering collinear multiple static obstacle, we propose an obstacle detection algorithm using LiDAR and a collision recognition and avoidance algorithm based on CPA. Preprocessing is performed to remove the ground from the LiDAR measurement data before obstacle detection. And we detect and classify obstacles in the preprocessed data using the K-means clustering algorithm. Also, we estimate the absolute positions of detected obstacles using relative navigation and correct the estimated positions using a low-pass filter. For collision avoidance with the detected multiple static obstacle, we use a collision recognition and avoidance algorithm based on CPA. Information of obstacles to be avoided is updated using distance between each obstacle, and collision recognition and avoidance are performed through the updated obstacles information. Finally, through obstacle location estimation, collision recognition, and collision avoidance result analysis in the Gazebo simulation environment, we verified that collision avoidance is performed successfully.

Accuracy of posteroanterior cephalogram landmarks and measurements identification using a cascaded convolutional neural network algorithm: A multicenter study

  • Sung-Hoon Han;Jisup Lim;Jun-Sik Kim;Jin-Hyoung Cho;Mihee Hong;Minji Kim;Su-Jung Kim;Yoon-Ji Kim;Young Ho Kim;Sung-Hoon Lim;Sang Jin Sung;Kyung-Hwa Kang;Seung-Hak Baek;Sung-Kwon Choi;Namkug Kim
    • The korean journal of orthodontics
    • /
    • v.54 no.1
    • /
    • pp.48-58
    • /
    • 2024
  • Objective: To quantify the effects of midline-related landmark identification on midline deviation measurements in posteroanterior (PA) cephalograms using a cascaded convolutional neural network (CNN). Methods: A total of 2,903 PA cephalogram images obtained from 9 university hospitals were divided into training, internal validation, and test sets (n = 2,150, 376, and 377). As the gold standard, 2 orthodontic professors marked the bilateral landmarks, including the frontozygomatic suture point and latero-orbitale (LO), and the midline landmarks, including the crista galli, anterior nasal spine (ANS), upper dental midpoint (UDM), lower dental midpoint (LDM), and menton (Me). For the test, Examiner-1 and Examiner-2 (3-year and 1-year orthodontic residents) and the Cascaded-CNN models marked the landmarks. After point-to-point errors of landmark identification, the successful detection rate (SDR) and distance and direction of the midline landmark deviation from the midsagittal line (ANS-mid, UDM-mid, LDM-mid, and Me-mid) were measured, and statistical analysis was performed. Results: The cascaded-CNN algorithm showed a clinically acceptable level of point-to-point error (1.26 mm vs. 1.57 mm in Examiner-1 and 1.75 mm in Examiner-2). The average SDR within the 2 mm range was 83.2%, with high accuracy at the LO (right, 96.9%; left, 97.1%), and UDM (96.9%). The absolute measurement errors were less than 1 mm for ANS-mid, UDM-mid, and LDM-mid compared with the gold standard. Conclusions: The cascaded-CNN model may be considered an effective tool for the auto-identification of midline landmarks and quantification of midline deviation in PA cephalograms of adult patients, regardless of variations in the image acquisition method.

Identifying Roadway Sections Influenced by Speed Humps Using Survival Analysis (생존분석을 활용한 과속방지턱 영향구간 분석)

  • YOON, Gyugeun;JANG, Youlim;KHO, Seung-Young;LEE, Chungwon
    • Journal of Korean Society of Transportation
    • /
    • v.35 no.4
    • /
    • pp.261-277
    • /
    • 2017
  • This study defines influencing sections as the part of the road section where passing vehicles are traveling with the lower speed compared to speed limit due to speed humps. The influencing section was divided into 3 parts; influencing section before the speed hump, interval section, and influencing section after the speed hump. This analysis focused on the changes of each part depending on installation types, vehicle types, and daytime or nighttime. For the interval section, especially, the ratio of distance traveled with lower speed than speed limit to interval section is defined as effective influencing section ratio to be analyzed. Vehicle speed profiles were collected with a speed gun to extract influencing section lengths. The survival analysis was applied and estimated survival functions are compared with each other by several statistical tests. As a consequence, the average length of influencing section on the 50m sequential speed humps was 75.3% longer during the deceleration than that of isolated speed hump, and 18.9% during the acceleration. The effective influencing section ratio for the 30m and 50m sequential speed humps had a small difference of 81.0% and 76.0% while the absolute values of the section that passing speed were less than the speed limit were longer on 50m sequential speed humps, each being 24.3m and 38.0m. Using the log rank test, it was evident that sequential speed humps were more effective to increase the length of influencing sections compared to the isolated speed hump. Vehicle type was the strong factor for influencing section length on the isolated speed hump, but daytime or nighttime was not the effective one. This research result can be used for improving the efficiency selecting the installation point of speed humps for road safety and estimating the standard of the distance between sequential speed humps.

Evaluating the Visual Contrast Rating of the Landscape Impact Factors - A case study for the Buildings in Natural Landscape - (경관영향 요소별 경관 대비성 평가 - 자연경관에 도입되는 건축물을 중심으로 -)

  • Choi, Won-Bin;Shin, Ji-Hoon
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.3
    • /
    • pp.87-96
    • /
    • 2018
  • While cities became bigger and bigger since 1990s, many indiscretely high buildings started to be built in the mountain areas inside a city and in the rural areas in the suburb of each city. To regulate such indiscrete developments, the government prepared for some relevant legal and institutional criteria by having enacted the "Landscape Act" and established a strong management means in the legal and institutional aspects by having introduced the natural landscape deliberation system and the landscape deliberation one into the "Natural Environment Conservation Act." However, since some uniform levels of absolute height and no. of stories are suggested legally and institutionally, it is hard to consider the effects of a real building structure onto the relevant landscape. Accordingly, this thesis is intended to grasp the contrast of the landscape elements in the allowable height section, which is presented through landscape sensitivity. As the results from the visual contrast rating on a small apartment complex located in Dangjin and a large scale of apartment complex in Seosan as the apartment complexes surrounded with natural landscapes that were selected as the subjects of this study, the following conclusion can be finalized. First, there were deducted some factors, that is, forms, lines, colors, textures and sizes as the ones with which can measure and evaluate the contrasting properties when a structure gets into a natural landscape. Second, in case of a small scale of apartment complex (in the foreground) compared to a large one (in the foreground), it was found that the contrasting properties were bigger. In addition, it was also found that the contrasting property of the landscape factor of the foreground compared to that of the middle one becomes bigger depending on a distance. Third, as the results from an evaluation on the contrasting properties of the landscape factor depending on the changes of each floor of a structure, it was found that the factors, that is, forms, lines, colors, textures and sizes are very significant. Among those factors, the factors, forms and lines in a small scale of apartment complex (in the foreground) showed each log regression. But in all of the other cases, they showed each line regression. Fourth, as the results from examining the regression coefficients of the landscape factor, the coefficients of the shapes and lines have similar coefficients and the colors and the textures have similar ones, too. In case of the sizes of apartment complexes, the colors and the textures of a large apartment complex (in the foreground) have similar coefficients, in case of that in the middle ground, the shapes and lines have similar coefficients. Fifth, as the results from estimating the contrasting properties of the landscape factor on the floors within the allowed scope of the landscape sensitivity, it was found that the contrasting property was 3.5 to 4.9 in case of a small scale of apartment complex (in the foreground), but 2.5to 3.7 in case of a small scale of one. In case of a large scale of apartment complex, the value was 3.5 to 5.3, but in case of a large one in the middle ground was 2.9 to 4.9. Sixth, it was comprehended that the contrasting properties of the landscape factor become different depending on each size of apartment complex and the distance of a view point. In this study, it is intended to find the meaning from the aspect that the results can be used as the baseline data for comprehending a proper range of heights of structures objectively during a natural landscape deliberation or a landscape deliberation.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.

Implementation of a Self Controlled Mobile Robot with Intelligence to Recognize Obstacles (장애물 인식 지능을 갖춘 자율 이동로봇의 구현)

  • 류한성;최중경
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.5
    • /
    • pp.312-321
    • /
    • 2003
  • In this paper, we implement robot which are ability to recognize obstacles and moving automatically to destination. we present two results in this paper; hardware implementation of image processing board and software implementation of visual feedback algorithm for a self-controlled robot. In the first part, the mobile robot depends on commands from a control board which is doing image processing part. We have studied the self controlled mobile robot system equipped with a CCD camera for a long time. This robot system consists of a image processing board implemented with DSPs, a stepping motor, a CCD camera. We will propose an algorithm in which commands are delivered for the robot to move in the planned path. The distance that the robot is supposed to move is calculated on the basis of the absolute coordinate and the coordinate of the target spot. And the image signal acquired by the CCD camera mounted on the robot is captured at every sampling time in order for the robot to automatically avoid the obstacle and finally to reach the destination. The image processing board consists of DSP (TMS320VC33), ADV611, SAA7111, ADV7l76A, CPLD(EPM7256ATC144), and SRAM memories. In the second part, the visual feedback control has two types of vision algorithms: obstacle avoidance and path planning. The first algorithm is cell, part of the image divided by blob analysis. We will do image preprocessing to improve the input image. This image preprocessing consists of filtering, edge detection, NOR converting, and threshold-ing. This major image processing includes labeling, segmentation, and pixel density calculation. In the second algorithm, after an image frame went through preprocessing (edge detection, converting, thresholding), the histogram is measured vertically (the y-axis direction). Then, the binary histogram of the image shows waveforms with only black and white variations. Here we use the fact that since obstacles appear as sectional diagrams as if they were walls, there is no variation in the histogram. The intensities of the line histogram are measured as vertically at intervals of 20 pixels. So, we can find uniform and nonuniform regions of the waveforms and define the period of uniform waveforms as an obstacle region. We can see that the algorithm is very useful for the robot to move avoiding obstacles.

UBVI CCD Photometry of NGC 7790 (NGC 7790의 UBVI CCD 측광)

  • Choi, Dong Yeol;Kim, Hee Soo;Lim, Beomdu;Sung, Hwankyung
    • Journal of the Korean earth science society
    • /
    • v.36 no.7
    • /
    • pp.661-673
    • /
    • 2015
  • UBVI CCD photometry of the intermediate age open cluster NGC 7790 has been obtained using AZT-22 1.5 m telescope (f/7.74) at the Maidanak Astronomical Observatory in Uzbekistan. NGC 7790 contains three ${\delta}$ Cep variable stars including CEa Cas, CEb Cas, and CF Cas. PSF photometry was carried out using IRAF/DAOPHOT for all observations. The total number of stars observed both in V and I filter was 1008 and the limiting magnitude was $V{\approx}22$. To determine atmospheric extinction coefficients and photometric zero points, many blue and red standard stars as well as the standard stars in the celestial equator under various airmass were observed. Photometric data were transformed into the standard Johnson-Cousins' UBVI standard system. From the analysis of UBVI color-magnitude diagram and color-color diagram, the color excess in V and I filter [$E(B-V)=0.58{\pm}0.02$], the selective extinction ratio in V and I filter [$R_V{\equiv}A_V/E(B-V)=3.02{\pm}0.09$] and distance modulus ($V_0-M_V=12.65{\pm}0.10$) of the cluster were determined. The age of the cluster was estimated to be log $age=8.05{\pm}0.05$ [yr] based on the position of these three Cepheid variables in the color-magnitude diagram, the isochrone of the Geneva group ($Ekstr{\ddot{o}}m$ et al., 2012-Z=0.019), and the isochrone of the Padova group (Bressan et al., 2012-Z=0.014) were used to compare each other. Of them, the Geneva models that considered stellar rotation well described the position of ${\delta}$ Cepheid variables in the blue loop. Although they were well consistent with standard period-luminosity relation of ${\delta}$ Cepheid variables, three Cepheid variables in NGC 7790 were, on average, brighter by about 0.5 mag than the absolute magnitude estimated from the mean period-luminosity relation at a given period.

Relationship between Stomach Volume and Tumor Location in Radiation Treatment for Hepatic Tumors (간 종양의 방사선치료에서 위내용적과 종양 위치 간의 관계)

  • Jeon, Mi-Jin;Lee, Chang-Geol;Lee, Ik-Jae;Choi, Won-Hoon;Choi, Yun-Sun;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Ha, Jin-Suk;Cho, Yoon-Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.75-83
    • /
    • 2010
  • Purpose: It aims to evaluate the location change and tendency of hepatic and intrahepatic tumors according to gastric volume and change of location. Materials and Methods: It studied 9 patients with hepatic tumors who visited Gangnam Severance Hospital from March 2009 to April 2010 and who underwent CT or PET (Positron Emission Tomography) within 2 weeks before CT-simulation. The patients fasted for 6 hours before CT-simulation and drank 240~250 cc of water just before CT or PET for image fusion. Those two types of images were fused to RTP (Radiation Treatment Planning, Pinnacle 8.0h) focusing on bone structure of individual patients. Results: They drank 240~260 cc of water but their stomach volume after drinking water varied from 259.3 cc to 495.4 cc. Even though individual differences existed in the change of stomach volume before and after drinking water, the volume was increased by 130 cc (174%) on average. The change in absolute distance between the centers of tumors ranged from 0.52 cm to 3.04 cm (1.52 cm on average); from 0.1 cm to 1.35 cm (0.44 cm on average) in cranial-caudal direction; from 0.05 cm to 2.75 cm (1.22 cm on average) in left-right direction; and from 0.05 cm to 1.85 cm (0.33 cm on average) in ventral-dorsal direction. Conclusion: It is hard to predict the movement of tumors by observing stomach movement, due to great individual differences; however, it was observed that the location of hepatic tumors was right-sided as the stomach was filled with water. Thus, it is recommended to maintain the fastened state to secure the accuracy of hepatic tumor treatment. If it cannot maintain the fastened state, it is recommended to measure stomach volumes and movement in the patient to consider the movement of hepatic tumors before radiation treatment.

  • PDF