• Title/Summary/Keyword: abnormality detection

Search Result 153, Processing Time 0.023 seconds

An u-healthcare system using an wireless sensor node with ECG analysis function by QRS-complex detection (QRS검출에 의한 ECG분석 기능을 갖춘 무선센서노드를 활용한 u-헬스케어 시스템)

  • Lee, Dae-Seok;Bhardwaj, Sachin;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.361-368
    • /
    • 2007
  • Small size real-time ECG signal analysis function by QRS-complex detection was put into sensor nodes. Wireless sensor nodes attached on the patient’s body transmit ECG data continuously in normal u-healthcare system. So there are heavy communication traffics between sensor nodes and gateways. New developed platform for real-time analysis of ECG signals on sensor node can be used as an advanced diagnosis and alarming system for healthcare. Sensor node does not need to transmit ECG data all the time in wireless sensor network and to server PC via gateway. When sensor node detects suspicion or abnormality in ECG, then the ECG data in the network was transmitted to the server PC for further powerful analysis. This system can reduce data packet overload and save some power in wireless sensor network. It can also increase the server performance.

Damage Detection in Bridges Using Modal Flexibility Matrices Under Temperature Variation (상시 온도변화 효과를 고려한 모드 유연도행렬 기반의 교량의 손상탐색기법)

  • Koo, Ki-Young;Lee, Jong-Jae;Yun, Chung-Bang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.651-656
    • /
    • 2007
  • Changes in measured structural responses induced by a damage could be significantly smaller than those by environmental effects such as temperature and temperature gradients. It is highly desirable to develop a methodology to distinguish the changes due to the structural damage from those by the environmental variations. In this study, a novel method to extract the damage-induced deflection under temperature variations is presented using the outlier analysis on the deflections obtained using the modal flexibility matrices. The main idea is that temperature change in a bridge would produce global increase or decrease in deflections over the whole bridge while structural damages may cause local variations in deflections near the damage locations. Hence, the correlation between the deflection measurements may show high abnormality near the damage locations. A series of laboratory tests were carried out on a bridge model with a steel box-girder for 14 days. It has been found that the damage existence assessment and localization can carried out for a case with relatively small damage under the temperature variations

  • PDF

Medical Image Segmentation: A Comparison Between Unsupervised Clustering and Region Growing Technique for TRUS and MR Prostate Images

  • Ingale, Kiran;Shingare, Pratibha;Mahajan, Mangal
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.5
    • /
    • pp.1-8
    • /
    • 2021
  • Prostate cancer is one of the most diagnosed malignancies found across the world today. American cancer society in recent research predicted that over 174,600 new prostate cancer cases found and nearly 31,620 death cases recorded. Researchers are developing modest and accurate methodologies to detect and diagnose prostate cancer. Recent work has been done in radiology to detect prostate tumors using ultrasound imaging and resonance imaging techniques. Transrectal ultrasound and Magnetic resonance images of the prostate gland help in the detection of cancer in the prostate gland. The proposed paper is based on comparison and analysis between two novel image segmentation approaches. Seed region growing and cluster based image segmentation is used to extract the region from trans-rectal ultrasound prostate and MR prostate images. The region of extraction represents the abnormality area that presents in men's prostate gland. Detection of such abnormalities in the prostate gland helps in the identification and treatment of prostate cancer

GNSS/Multiple IMUs Based Navigation Strategy Using the Mahalanobis Distance in Partially GNSS-denied Environments (GNSS 부분 음영 지역에서 마할라노비스 거리를 이용한 GNSS/다중 IMU 센서 기반 측위 알고리즘)

  • Kim, Jiyeon;Song, Moogeun;Kim, Jaehoon;Lee, Dongik
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.4
    • /
    • pp.239-247
    • /
    • 2022
  • The existing studies on the localization in the GNSS (Global Navigation Satellite System) denied environment usually exploit low-cost MEMS IMU (Micro Electro Mechanical Systems Inertial Measurement Unit) sensors to replace the GNSS signals. However, the navigation system still requires GNSS signals for the normal environment. This paper presents an integrated GNSS/INS (Inertial Navigation System) navigation system which combines GNSS and multiple IMU sensors using extended Kalman filter in partially GNSS-denied environments. The position and velocity of the INS and GNSS are used as the inputs to the integrated navigation system. The Mahalanobis distance is used for novelty detection to detect the outlier of GNSS measurements. When the abnormality is detected in GNSS signals, GNSS data is excluded from the fusion process. The performance of the proposed method is evaluated using MATLAB/Simulink. The simulation results show that the proposed algorithm can achieve a higher degree of positioning accuracy in the partially GNSS-denied environment.

Autoencoder-based MCT Anomaly Detection Algorithm (오토인코더를 활용한 MCT 이상탐지 알고리즘 개발)

  • Kim, Min-hee;Jin, Kyo-hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.89-92
    • /
    • 2021
  • In a manufacturing fields, an abnormality or breakdown of equipment is a factor that causes product defects. Recently, with the spread of smart factory services, a lot of research to predict and prevent machine's failures is actively ongoing. However, there is a big difficulty in developing a classification model because the number of abnormal or failure data of the machine is severely smaller than normal data. In this paper, we present an algorithm for detecting abnormalities in an MCT at manufacturing work site depending on the differences between inputs and outputs of Autoencoder model and analyze its performance. The algorithm detects abnormalities using only features of normal data from manufacturing data of the MCT in which abnormal data does not exist.

  • PDF

Abnormal Situation Detection Algorithm via Sensors Fusion from One Person Households

  • Kim, Da-Hyeon;Ahn, Jun-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.4
    • /
    • pp.111-118
    • /
    • 2022
  • In recent years, the number of single-person elderly households has increased, but when an emergency situation occurs inside the house in the case of single-person households, it is difficult to inform the outside world. Various smart home solutions have been proposed to detect emergency situations in single-person households, but it is difficult to use video media such as home CCTV, which has problems in the privacy area. Furthermore, if only a single sensor is used to analyze the abnormal situation of the elderly in the house, accurate situational analysis is limited due to the constraint of data amount. In this paper, therefore, we propose an algorithm of abnormal situation detection fusion inside the house by fusing 2DLiDAR, dust, and voice sensors, which are closely related to everyday life while protecting privacy, based on their correlations. Moreover, this paper proves the algorithm's reliability through data collected in a real-world environment. Adnormal situations that are detectable and undetectable by the proposed algorithm are presented. This study focuses on the detection of adnormal situations in the house and will be helpful in the lives of single-household users.

A Study on Oriental Medical Diagnosis of Musculoskeletal Disorders using Moire Image (Moire 영상을 이용한 근골격계 질환의 한의학적 진단에 관한 연구)

  • Lee Eun-Kyoung;Yu Seung-Hyun;Lee Su-Kyung;Kang Sung-Ho;Han Jong-Min;Chong Myong-Soo;Chun Eun-Joo;Song Yung-Sun;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.4 no.2
    • /
    • pp.72-92
    • /
    • 2000
  • This research has conducted studies on an Oriental medicine-based method of diagnosing of occupational musculoskeletal system diseases. This researcher has searched through existing relevant medical literature. Also, this researcher has worked on a moire topography using moire topography. In this course, this researcher has reached the following conclusion in relation to the possibility of using a moire topography as a diagnosing device of musculoskeletal system diseases under Oriental medicine . 1 The Western medicine outlines its criteria of screening occupational musculoskeletal system diseases as follows A. The occupational musculoskeletal diseases must clearly include one or more of the subjective symptoms characterized by pain, hypoesthesia dysaesthesia, anaesthesia. etc . B, There should be clinically admitted objective observations and diagnosis outlining that the disease concerned shows symptoms such as tenderness, induration. and edema that can appear with occupational musculoskeletal system diseases. dyscinesia should be admitted with the disease concerned, or there should be observations and diagnosis outlining that abnormality exists in electric muscular or nervous diagnosis and examination . C. It should be admitted that prior to the occurrence of symptoms or observations and diagnosis on musculoskeletal system-related diseases, a patient has been engaged in works with conditions requiring improper work posture or work movement. That is, this is an approach whereby they see abnormality in the musculoskeletal system come from material and structural defect, and adjust and control abnormality in the musculoskeletal system and secreta . 2. The Oriental medicines sees that a patient develops the pain of occupational musculoskeletal diseases as he cannot properly activate the flow of his life force and blood thus not only causing formation of lumps in the body and blocking the flow of life force and blood in some parts of the body. Hence, The Oriental medicine focuses on resolving the cause of weakening the flow of life force and blood, instead of taking material approach of correcting structural abnormality Furthermore , Oriental medicine sees that when muscle tension builds up, this presses blood vessels and nerves passing by, triggering circulation dyscrasia and neurological reaction and thus leading to lesion. Thus, instead of taking skeletal or neurophysiological approach. it seeks to fundamentally resolve the cause of the flow of the life force and blood in muscles not being activated. As a result Oriental medicine attributes the main cause of musculoskeletal system diseases to muscle tension and its build-up that stem from an individual's long formed chronicle habit and work environment. This approach considers not only the social structure aspect including companies owners and work environment that the existing methods have looked at, but also individual workers' responsibility and their environmental factors. Hence, this is a step forward method. 3 The diagnosis of musculoskeletal diseases under Oriental medicine is characterized by the fact that an Oriental medicine doctor uses not only photos taken by himself, but also various detection devices to gather information and pass comprehensive judgment on it. Thus, it is the core of diagnosis under Oriental medicine to develop diagnosing devices matching the characteristics of information to be induced and to interpret information so induced from the views of Oriental medicine. Diagnosis using diagnosing devices values the whole state of a patient and formal abnormality alike, and the whole balance and muscular state of a patient serves as the basis of diagnosis. Hence, this method, instead of depending on the information gathered from devices under Western medicine, requires devices that provide information on the whole state of a patient in addition to the local abnormality information that X-ray. CT, etc., can offer. This method sees muscle as the central part of the abnormality in the musculoskeletal system and thus requires diagnosing devices enabling the muscular state. 4. The diagnosing device using moire topography under Oriental medicine has advantages below and can be used for diagnosing musculoskeletal system diseases with industrial workers . First, the device can Provide information on the body in an unbalanced state. and thus identify the imbalance and difference of height in the left and right stature that a patient can not notice at normal times. Second, the device shows the twisting of muscles or induration regions in a contour map. This is not possible with existing shooting machines such as X-ray, CT, etc., thus differentiating itself from existing machines. Third, this device makes it possible for Oriental medicine to take its unique approach to the abnormality in the musculoskeletal system. Oriental medicine sees the state and imbalance state in muscles as major factors in determining the lesion of musculoskeletal system, and the device makes it possible to shoot the state of muscles in detail. In this respect, the device is significant. Fourth, the device has an advantage as non-aggression diagnosing device.

  • PDF

CT Study of Spondylolisthesis Comparison Between Isthmic and Degenerative Type (척추 전방전위증의 전산화 단층촬영 소견 : 협부형과 퇴행형의 비교)

  • Lee, Jong-Deok;Byun, Jae-Young
    • Journal of Acupuncture Research
    • /
    • v.17 no.4
    • /
    • pp.79-87
    • /
    • 2000
  • Objectives : To evaluate the findings useful for differential diagnosis and associated abnormaiities of isthmic spondylolisthesis and degenerative spondylolisthesis on CT. Materials and methods : We reviewed retrospectively the CT images of 65 patients who were diagnosed spondylolisthesis during 3 years period. Our technique was 5mm slices at 5mm intervals with gantry angle to parallel the interspaces. Also reformatted sagittal views were taken. 41 patients were isthmic spondylolisthesis and 24 patients were degenerative spondylolisthesis. Resuits : Isthmic spondylolisthesis. 1. Isthmic type was more common at L5-S1. 2. The degree of anterior displacement was grade I and II. 3. The plane of defect was more horizontal than the usual facet joint. 4. The defect had an irregular shape. 5. Medial aspect of bone just anterior to defect had a small round prominence. 6. Anteroposterior elongation of the spinal canal was common. 7. Pseudobulging disk was common. 8. The most common associated abnormality was a HNP at the upper level of the defect. Degenerative spondylolisthesis. 1. Degenerative type was more common at L4-5. 2. The degree of anterior disptacement was grade I and II. 3. The Plane of facet joint was oriented obliquely instead of horizontally. 4. The posterior facet(inferior facet of superior vertebra) was anteriorly displaced. 5. Bony spur of the posterior portion of anterior facet was seen. 6. The facet joints often contain gas(vaccum phenomenum). 7. The most common associated abnormality was a HNP at the level of the displacement. Conclusions : CT is a highly accurate and most sensitive technique for recognition, differential diagnosis of isthmic and degenerative types and the detection of associated abnormalities.

  • PDF

Human Telomerase Gene and High-Risk Human Papillomavirus Infection are Related to Cervical Intraepithelial Neoplasia

  • Zhao, Xu-Ye;Cui, Yongm;Jiang, Shu-Fang;Liu, Ke-Jun;Han, Hai-Qiong;Liu, Xiao-Su;Li, Yali
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.693-697
    • /
    • 2015
  • Our aims were to evaluate the clinical performance of human telomerase RNA gene component (hTERC gene) amplification assay with high-risk human papillomavirus (HR-HPV) DNA test of Hybrid Capture 2 DNA test (HC2), for the detection of high grade cervical precancerous lesions and cancer (CIN 2+). In addition, the association shown between hTERC gene amplification and HPV DNA test positive in women with and without cervical neoplasia was assessed. There were 92 women who underwent cytology, HR-HPV DNA test, hTERC gene amplification test, colposcopy and biopsy. We compared the clinical performance of hTERC gene test along with HR-HPV DNA test of women with colposcopy and routine screening. The samples were histology-confirmed high-grade cervical intraepithelial neoplasia (CIN 2) or worse (CIN2+) as the positive criterion. The test of hTERC gene showed the hTERC gene amplification positivity increased with the severity of histological abnormality and cytological abnormality. The test of hTERC gene showed higher specificity than HR-HPV DNA test for high-grade lesions (84.4% versus 50%) and also higher positive predictive value (90.4% versus 76.5%). Our results predicted that hTERC gene amplification demonstrated more specific performance for predicting the risk of progression and offer a strong potential as a tool for triage in cervical cancer screening, with the limited sensitive as HR-HPV DNA test.

Genomic Alteration of Bisphenol A Treatment in the Testis of Mice

  • Kim, Seung-Jun;Park, Hye-Won;Youn, Jong-Pil;Ha, Jung-Mi;An, Yu-Ri;Lee, Chang-Hyeon;Oh, Moon-Ju;Oh, Jung-Hwa;Yoon, Seok-Joo;Hwang, Seung-Yong
    • Molecular & Cellular Toxicology
    • /
    • v.5 no.3
    • /
    • pp.216-221
    • /
    • 2009
  • Bisphenol A (BPA) is commonly used in the production of pharmaceutical, industrial, and housing epoxy, as well as polycarbonate plastics. Owing to its extensive use, BPA can contaminate the environment either directly or through derivatives of these products. BPA has been classified as an endocrine disruptor chemicals (EDCs), and the primary toxicity of these EDCs in males involves the induction of reproductive system abnormality. First, in order to evaluate the direct effects on the Y chromosome associated with reproduction, we evaluated Y chromosome abnormalities using a Y chromosome microdeletion detection kit. However, we detected no Yq abnormality as the result of BPA exposure. Secondly, we performed high-density oligonucleotide array-based comparative genome hybridization (CGH) to assess genomic alteration as a component of our toxicity assessment. The results of our data analysis revealed some changes in copy number. Seven observed features were gains or losses in chromosomal DNA (P-value<1.0e-5, average log2 ratio>0.2). Interestingly, 21 probes of chr7:7312289-10272836 (qA1-qA2 in cytoband) were a commonly observed amplification (P-value 3.69e-10). Another region, chr14:4551029-10397399, was also commonly amplified (P-value 2.93e-12, average of log2 ratios in segment>0.3786). These regions include many genes associated with pheromone response, transcription, and signal transduction using ArrayToKegg software. These results help us to understand the molecular mechanisms underlying the reproductive effects induced by BPA.