• Title/Summary/Keyword: abnormal waves

Search Result 83, Processing Time 0.022 seconds

Analysis of Abnormal Settlement Aspect of Caisson Breakwater by Incoming Wave Action in Affected Area of Typhoon (태풍영향권 내습파랑에 의한 직립방파제 이상침하 현상분석)

  • Lee, Joong-Koo;Kim, Hyo-Seob;Park, Koo-Yong;Ahn, Ik-Seong
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.6
    • /
    • pp.508-517
    • /
    • 2009
  • The real time movement of the caisson was measured when it was open to the waves during breakwater construction. As a result of measurement, no more settlement after the preloading in condition of designed loading was expected but sudden abnormal settlement took place through whole area of the breakwater when waves occurred by typhoon effect. To clarify the reason of this case, wave of the site has been reproduced and the equivalent wave pressure on the caisson was calculated. The numerical analysis of the effect of wave to the ground had been done. Site measurement data is in accordance with the result of numerical analysis.

Patterns of Strong Heat Waves within the Seoul Metropolitan Area and Its Impacts on Elderly Mortality Based on the Last 100 Year Observations (지난 100년 동안 서울시에 발생한 강한 열파 패턴과 노인사망자에 미치는 영향)

  • Choi, Gwang-Yong
    • Journal of the Korean Geographical Society
    • /
    • v.45 no.5
    • /
    • pp.573-591
    • /
    • 2010
  • In this study, trends of heat waves in the populous Seoul metropolitan area over the last 100 years (1908-2007) and spatio-temporal patterns of extreme heat waves and excessive human mortality are examined. In spite of recent global warming, there is no observable increasing or decreasing pattern in the frequency and intensity of heat waves in Seoul due to increases of summer precipitation. Among numerous episodes over the last 100 years in Seoul, 1994 summer is recognized as the unprecedented, most extreme hot episode with long-lasting, intense heat waves Meteorological data observed at the Automatic Weather Stations (AWS) and land surface temperature data derived from Landsat TM satellite imagery in July 1994 reveal that extreme heat waves cause more abnormal increase of elderly mortality in the urbanized areas than in the surroundings covered with more vegetation. This study provides bioclimatological evidences of why urban thermal environments should be seriously considered in the future urban revitalization planning.

CFD CONFIRMATION OF ABNORMAL SHOCK WAVE INTERACTIONS (전산해석을 통한 비정상 Mach Reflection Wave Configuration 확인)

  • Hu, Z.M;Yang, Y.R.;Zhang, Y.;Myong, R.S.;Cho, T.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.92-96
    • /
    • 2008
  • For the Mach reflection of symmetric shock waves, only the wave configuration of an oMR(DiMR+DiMR) is theoretically admissible. For asymmetric shock waves, an oMR(DiMR+InMR) will be possible if the two slip layers assemble a convergent-divergent stream tube while an oMR(InMR+InMR) is absolutely impossible. In this paper, an overall Mach reflection configuration with double inverse MR patterns is confirmed using the CFD technique. Classical two- and three-shock theories are also applied for the theoretical analysis. In addition, oscillations of shock wave patterns are computed for the interaction of a hypersonic flow and double-wedge-like geometries.

  • PDF

CFD CONFIRMATION OF ABNORMAL SHOCK WAVE INTERACTIONS (전산해석을 통한 비정상 Mach Reflection Wave Configuration 확인)

  • Hu, Z.M.;Yang, Y.R.;Zhang, Y.;Myong, R.S.;Cho, T.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.92-96
    • /
    • 2008
  • For the Mach reflection of symmetric shock waves, only the wave configuration of an oMR(DiMR+DiMR) is theoretically admissible. For asymmetric shock waves, an oMR(DiMR+InMR) will be possible if the two slip layers assemble a convergent-divergent stream tube while an oMR(InMR+InMR) is absolutely impossible. In this paper, an overall Mach reflection configuration with double inverse MR patterns is confirmed using the CFD technique. Classical two- and three-shock theories are also applied for the theoretical analysis. In addition, oscillations of shock wave patterns are computed for the interaction of a hypersonic flow and double-wedge-like geometries.

  • PDF

Numerical analysis of the ventricular fibrillation phenomena using two-dimensional Tissue Model (2차원 조직모델을 사용한 심실세동 현상의 수치적 해석)

  • Choi, Seung-Yun;Hong, Seung-Bae;Lim, Ki-Moo;Shim, Eun-Bo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1665-1668
    • /
    • 2008
  • Arrhythmia causes sudden cardiac death. In the past, there were medical limitations in finding the cause of arrhythmia. As an alternative solution for research of arrhythmia, there have been studies to find the causes of arrhythmia by producing a virtual heart model. Medically, arrhythmia has two main causes: abnormal occurrence of action potential and abnormal conduction of action potential. Based on these, the tachycardia, which is one of the arrhythmia, was manifested and the phenomenon of ventricular fibrillation was numerically analyzed in this study. For this purpose, an electrophysiological model of ventricular cells was implemented, which was subsequently applied to the reaction-diffusion partial differential equation to interpret the macroscopic conduction phenomenon in two-dimensional tissues. The ventricular fibrillation refers to a condition where several irregular waves occur in cardiac tissue, whose generation mechanism is pathologically related to the cardiac tissue.

  • PDF

Evaluation criteria for freezing and thawing of tunnel concrete lining according to theoretical and experimental analysis

  • Moon, Joon-Shik;An, Jai-Wook;Kim, Hong-Kyoon;Lee, Jong-Gun;Lattner, Tim
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.349-357
    • /
    • 2022
  • Abnormal climate events are occurring frequently around the world. In particular, cold waves and heavy snow lead to damage and deterioration of facilities, which can cause loss of life or property damage, such as shortening the lifespan of facilities. Therefore, it is very important to prepare an appropriate maintenance system and to establish a strategy to cope with abnormal weather conditions. In this study, laboratory freezing experiments were performed to analyze the freeze-thaw characteristics affecting the tunnel concrete lining, and heat flow analysis was carried out based on the test results. Based on these experimental and theoretical analysis results, quantitative freeze-thaw evaluation criteria for tunnel concrete linings were proposed.

Frequency Spectrum Analysis of Electromagnetic Waves Radiated by Electric Discharges

  • Park, Dae-Won;Kil, Gyung-Suk;Cheon, Sang-Gyu;Kim, Sun-Jae;Cha, Hyeon-Kyu
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.389-395
    • /
    • 2012
  • In this paper, we analyzed the frequency spectrum of the electromagnetic waves radiated by an electric discharge as a basic study to develop an on-line diagnostic technique for power equipment installed inside closed-switchboards. In order to simulate local and series arc discharges caused by an electric field concentration and poor connections, three types of electrode systems were fabricated, consisting of needle and plane electrodes and an arc generator meeting the specifications of UL 1699. The experiment was carried out in an electromagnetic anechoic chamber, and the measurement system consisted of a PD free transformer, a loop antenna with a frequency bandwidth of 150 kHz-30 MHz, an ultra log periodic antenna with a frequency bandwidth of 30 MHz-2 GHz, and an EMI test receiver with a frequency bandwidth of 3 Hz-3 GHz. According to the experimental results, the frequency spectra of the electrical discharges were widely distributed across a range of 150 kHz-400 MHz, depending on the defects, while commonly found between 150 kHz and 10 MHz. Therefore, considering the ambient noise and antenna characteristics, the best frequency bandwidth for a measurement system to monitor abnormal conditions by detecting electromagnetic waves in closedswitchboards is 150 kHz-10 MHz.

Severe hypermagnesemia presenting with abnormal electrocardiographic findings similar to those of hyperkalemia in a child undergoing peritoneal dialysis

  • Jhang, Won Kyoung;Lee, Yoon Jung;Kim, Young A;Park, Seong Jong;Park, Young Seo
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.7
    • /
    • pp.308-311
    • /
    • 2013
  • In this report, we present a pediatric case of severe symptomatic hypermagnesemia resulting from the use of magnesium oxide as a laxative in a child undergoing continuous cyclic peritoneal dialysis for end-stage renal disease. The patient showed abnormal electrocardiography (ECG) findings, such as tall T waves, a widened QRS complex, and irregular conduction, which were initially misdiagnosed as hyperkalemia; later, the correct diagnosis of hypermagnesemia was obtained. Emergent hemodialysis successfully returned the serum magnesium concentration to normal without complications. When abnormal ECG changes are detected in patients with renal failure, hypermagnesemia should be considered.

A Digital Filter for the Qrs Complex Detection Based-on Microcomputer (마이크로 컴퓨터를 이용한 QRS파형 검출용 디지탈필터)

  • 신건수
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.173-182
    • /
    • 1984
  • This paper represents a algorithm which improves the some drawbacks in the past methods for detecting QRS Complex waves. This proposed algorithm is very useful to detect correctly QRS Complex not only in a normal ECG, but in the abnormal ECG such as contaminating the noise with high amplitude, the existence of sharp T wave, and abrupt stepwise fluctuation of the base line.

  • PDF