• Title/Summary/Keyword: ablation rate

Search Result 177, Processing Time 0.029 seconds

Femtosecond laser pattering of ITO film on flexible substrate (펨토초 레이저를 이용한 플렉시블 ITO 패터닝 연구)

  • Sohn, Ik-Bu;Kim, Young-Seop;Noh, Young-Chul
    • Laser Solutions
    • /
    • v.13 no.1
    • /
    • pp.11-15
    • /
    • 2010
  • Indium tin oxide (ITO) provides high electrical conductivity and transparency in the visible and near IR (infrared) wavelengths. Thus, it is widely used as a transparent electrode for the fabrication of liquid crystal displays (LCDs) and organic light emitting diode displays (OLRDs), photovoltaic devices, and other optical applications. Lasers have been used for removing coating on polymer substrate for flexible display and electronic industry. In selective removal of ITO layer, laser wavelength, pulse energy, scan speed, and the repetition rate of pulses determine conditions, which are efficient for removal of ITO coating without affecting properties of the polymer substrate. ITO coating removal with a laser is more environmentally friendly than other conventional etching methods. In this paper, pattering of ITO film from polymer substrates is described. The Yb:KGW femtosecond laser processing system with a pulse duration of 250fs, a wavelength of 1030nm and a repetition rate of 100kHz was used for removing ITO coating in air. We can remove the ITO coating using a scanner system with various pulse energies and scan speeds. We observed that the amount of debris is minimal through an optical and a confocal microscope, and femtosecond laser pulses with 1030nm wavelength are effective to remove ITO coating without the polymer substrate ablation.

  • PDF

Properties of Conformal Antenna for Mobile Phone by Laser Direct Structuring

  • Park, Sang-Hoon;Kim, Gi-Ho;Jeon, Yong-Seung;Na, Ha-Sun;Seong, Won-Mo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.246-249
    • /
    • 2007
  • A triple-band antenna was developed and fabricated by LDS(Laser Direct Structuring) process. The effects of the plating rate and heat treatment condition were investigated and the gains of fabricated antennas were measured at various frequencies. The laser irradiated surface shows clearly that there are prominence and depression. It shows anchoring effect between a plating material and ablation surface. The plating rate was decreased when the plating material is exhausted in the solution. This solution needs to refreshed by the new aid solution. The copper plating thickness is decreased with the increase of heat treatment temperature in the same time but it does not change other condition. The gain of LDS antenna showed higher than the generally processed antenna. This result was related with practical use of the dimension and effective dielectric constant.

Reconstruction with Radial Forearm Free Flap after Ablative Surgery for Oral Cavity and Oropharyngeal Cancers (구강암과 구인두암의 절제술 후 전완유리피판술을 이용한 재건술)

  • Cho Kwang-Jae;Chun Byung-Jun;Sun Dong-Il;Cho Seung-Ho;Kim Mn-Sik
    • Korean Journal of Head & Neck Oncology
    • /
    • v.19 no.1
    • /
    • pp.41-46
    • /
    • 2003
  • Background and Objectives: Surgical ablation of tumors in the oral cavity and the oropharynx results in a three dimensional defect because of the needs to resect the adjacent area for the surgical margin. Although a variety of techniques are available, radial forearm free flap has been known as an effective method for this defect, which offers a thin, pliable, and relatively hairless skin and a long vascular pedicle. We report the clinical results of our 54 consecutive radial forearm free flaps used for oral cavity and oropharynx cancers. Materials and Methods: We reviewed the medical records of patients who were offered intraoral reconstruction with a radial forearm free flap after ablative surgery for oral cavity and oropharyngeal cancers from August 1994 to February 2003 and analyzed surgical methods, flap survival rate, complication, and functional results. Among these, 20 cases were examined with modified barium swallow to evaluate postoperative swallowing function and other 8 cases with articulation and resonance test for speech. We examined recovery of sensation with two-point discrimination test in 15 cases who were offered sensate flaps. Results: The primary sites were as follows : mobile tongue (18), tonsil (17), floor of mouth (4), base of tongue (2), soft palate (2), retromolar trigone (3), buccal mucosa (1), oro-hypopharynx (6), and lower lip (1). The paddles of flaps were tailored in multilobed designs from oval shape to tetralobed design and in variable size according to the defects after ablation. This procedures resulted in satisfactory flap success rate (96.3%) and showed good swallowing function and social speech. Eight of 15 cases (53.3%) who had offered sensate flap showed recovery of sensation between 1 and 6 postoperative months (average 2.6 month). Conclusion: The reconstruction with radial forearm free flap might be an excellent method for the maximal functional results after ablative surgery of oral cavity and oropharyngeal cancers that results in multidimensional defect.

CUTTING EFFICACY OF Er:YAG LASER AND CONVENTIONAL BUR IN DECIDUOUS AND PERMANENT TEETH (Er:YAG laser와 Conventional bur의 유치와 영구치 치아삭제효과 비교)

  • Park, In-Cheon;Lee, Chang-Seop;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.272-285
    • /
    • 2003
  • This study was conducted to observe the microscopic structures of cavities formed after ablation of primary teeth, permanent teeth, enamel and dentin in using a bur and cavities formed after ablation using laser and the following results were obtained after comparing the effects of ablation. Using a #330 bur and Er:YAG laser irradiated at 150 mJ, 200 mJ, 250 mJ and 300 mJ all at the frequency of 5 Hz, 1 mm enamel and dentin samples were ablated and the ablation time was measured. In order to measure the surfaces ablated, 5 each of primary teeth and permanent teeth were ablated using a #330 bur and Er:YAG laser at 150 mJ, 200 mJ, 250 mJ and 300 mJ for 1 sec and the cross section and vertical section were observed. The following results were obtained : 1. Cutting time of Er:YAG laser was longer than that of conventinal high-speed bur regardless of teeth type. 2. Cutting on enamel, Cutting time of conventional high-speed bur in deciduous teeth was longer than in permanent teeth(P<0.05). But Er:YAG laser was not showed any difference between the deciduous and permanent teeth(P>0.05). 3. Cutting on dentin, Cutting time of conventional high-speed bur in permanent teeth was longer than deciduous teeth. Er:YAG laser of 150 mJ, 5 Hz in permanent teeth was longer than in deciduous teeth(p<0.05). But laser of other power did not showed mean difference. 4. The cavity surface treated with the convetional high-speed bur revealed a relatively flat appearance, almost covered with a debris-like smear layer. Cavity wall showed striped appearance because of blade of bur. 5. The cavity surface treated by the Er:YAG laser system was irregular or rough surface with the absence charring, carbonization, or cracking of the dentin. In addition, there was an absence of a smear layer. Cavity floor was round and relatively smooth. According to these results, cutting time of Er:YAG laser was almostly same in permanent and deciduous teeth, but more effective in dentin than enamel. Cutting the sample, Er:YAG laser was needed more time than conventional bur. But SEM findings suggested that laser device produced favorable surface characteristic(i.e, no smear layer, irregular surface, cracking).

  • PDF

Ultrasonic dissection versus electrocautery for immediate prosthetic breast reconstruction

  • Lee, Dongeun;Jung, Bok Ki;Roh, Tai Suk;Kim, Young Seok
    • Archives of Plastic Surgery
    • /
    • v.47 no.1
    • /
    • pp.20-25
    • /
    • 2020
  • Background Ultrasonic dissection devices cause less thermal damage to the surrounding tissue than monopolar electrosurgical devices. We compared the effects of using an ultrasonic dissection device or an electrocautery device during prosthetic breast reconstruction on seroma development and short-term postoperative complications. Methods We retrospectively reviewed the medical records of patients who underwent implant-based reconstruction following mastectomy between March 2017 and September 2018. Mastectomy was performed by general surgeons and reconstruction by plastic surgeons. From March 2017 to January 2018, a monopolar electrosurgical device was used, and an ultrasonic dissection device was used thereafter. The other surgical methods were the same in both groups. Results The incidence of seroma was lower in the ultrasonic dissection device group than in the electrocautery group (11 [17.2%] vs. 18 [31.0%]; P=0.090). The duration of surgery, total drainage volume, duration of drainage, overall complication rate, surgical site infection rate, and flap necrosis rate were comparable between the groups. Multivariate analysis revealed that the risk of seroma development was significantly lower in the ultrasonic dissection device group than in the electrocautery group (odds ratio for electrocautery, 3.252; 95% confidence interval, 1.242-8.516; P=0.016). Conclusions The findings of this study suggest that the incidence of seroma can be reduced slightly by using an ultrasonic dissection device for prosthesis-based breast reconstruction. However, further randomized controlled studies are required to verify our results and to assess the cost-effectiveness of this technique.

7-mm-long dental implants: retrospective clinical outcomes in medically compromised patients

  • Nguyen, Truc Thi Hoang;Eo, Mi Young;Cho, Yun Ju;Myoung, Hoon;Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.5
    • /
    • pp.260-266
    • /
    • 2019
  • Objectives: Dental implants shorter than 8 mm, called short dental implants (SDIs), have been considered to have a lower success rate than standard length implants. But recent studies have shown that SDIs have a comparable success rate, and implant diameter was more important for implant survival than implant length. Also, SDIs have many advantages, such as no need for sinus lifting or vertical bone grafting, which may limit use in medically compromised patients. Materials and Methods: In this study, 33 patients with 47 implants 7-mm long were examined over the last four years. All patients had special medical history and were categorized into 3 groups: systemic disorders, such as diabetes mellitus (controlled or uncontrolled), mental disability, and uncontrolled hypertension; oral cancer ablation with reconstruction, with or without radiotherapy; diverse osteomyelitis, such as osteoradionecrosis and bisphosphonate-related osteonecrosis of the jaw. Most of these patients have insufficient residual bone quality due to mandible atrophy or sinus pneumatization. Results: The implant diameters were 4.0 (n=38), 4.5 (n=8), and 5.0 mm (n=1). Among the 47 implants placed, 2 implants failed before the last followup. The survival rate of 7-mm SDIs was 95.74% from stage I surgery to the last follow-up. Survival rates did not differ according to implant diameter. The mean marginal bone loss (MBL) at 3 months, 1 and 2 years was significantly higher than at implant installation, and the MBL at 1 year was also significantly higher than at 3 months. MBL at 1 and 2 years did not differ significantly. Conclusion: Within the limitations of the present study, the results indicate that SDIs provide a reliable treatment, especially for medically compromised patients, to avoid sinus lifting or vertical bone grafting. Further, long-term follow-up is needed.

Hybrid argon plasma coagulation in Barrett's esophagus: a systematic review and meta-analysis

  • Sagar N. Shah;Nabil El Hage Chehade;Amirali Tavangar;Alyssa Choi;Marc Monachese;Kenneth J. Chang;Jason B. Samarasena
    • Clinical Endoscopy
    • /
    • v.56 no.1
    • /
    • pp.38-49
    • /
    • 2023
  • Background/Aims: Patients with Barrett's esophagus are at increased risk of developing esophageal adenocarcinoma. Endoscopic therapies aim to eradicate dysplastic and metaplastic tissues. Hybrid argon plasma coagulation (hybrid-APC) utilizes submucosal fluid injection to create a protective cushion prior to ablation that shields the submucosa from injury. We performed a pooled meta-analysis to evaluate the safety and efficacy of hybrid-APC. Methods: We conducted a systematic search of major electronic databases in April 2022. Studies that included patients with dysplastic and non-dysplastic Barrett's esophagus undergoing treatment with hybrid-APC were eligible for inclusion. Outcome measures included complete remission of intestinal metaplasia (CR-IM), stricture formation, serious adverse events, and number of sessions necessary to achieve CR-IM. Results: Overall pooled CR-IM rate for patients undergoing hybrid-APC was 90.8% (95% confidence interval [CI], 0.872-0.939; I2=0%). Pooled stricture rate was 2.0% (95% CI, 0.005-0.042; I2=0%). Overall serious adverse event rate was 2.7% (95% CI, 0.007-0.055; I2=0%). Conclusions: Results of the current meta-analysis suggest that hybrid-APC is associated with high rates of CR-IM and a favorable safety profile. Interpretation of these results is limited by the inclusion of retrospective cohort and case series data. Randomized controlled trials that standardize treatment and outcome evaluation protocols are necessary to understand how this treatment option is comparable to the current standards of care.

Development of New Device to Improve Sucess Rate of Maze Procedure with Radiofrequency Energy (고주파에너지를 이용한 미로술식의 성적향상을 위한 새로운 기구의 개발)

  • 박남희;유양기;이재원
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.467-473
    • /
    • 2004
  • Background: The sinus conversion rate after the maze procedure in chronic atrial fibrillation using radiofrequency energy is lower than with either conventional 'cut and saw' technique or cryothermia. The creation of incomplete transmural lesions due to poor tissue-catheter contact is thought to be the main cause. To address this problem, the current study was aimed to evaluate the effectiveness of a specially constructed compression device designed to enhance tissue catheter contact during unipolar radiofrequency catheter ablation. Material and Method: Circum-ferential right auricular epicardial lesions were created with a linear radiofrequency catheter in 10 anesthetized pigs. A device specially designed to increase contact by compression of the catheter to the atrial wall was used in 5 pigs (study group). This device was not used in the control group (5 pigs). Conduction block across the right auricular lesion was assessed by pacing, and the transmurality of the lesions were confirmed by microscopic examination. Result: Conduction block was observed in a total of 8 pigs; 5 in study group and 3 in control group. Transmural injury was confirmed microscopically by the accumulation of acute inflammatory cells and loss of elastic fibers in the endocardium. In two pigs with failed conduction block, microscopic examination of the endocardium appeared normal. Conclusion: Failed radiofrequency ablation is strongly related to non-transmural energy delivery. The specially constructed compression device in the current study was successful in creating firm tissue-catheter contact and thereby generating transmural lesions during unipolar radiofrequency ablation.

Probing of Microscale Phase-Change Phenomena Based on Michelson Interforometry (Michelson 간섭계를 응용한 미세 상변화 현상 계측)

  • Kim, Dong-Sik;Park, Hee-K.;Grigoropoulos, Costas P.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.348-353
    • /
    • 2001
  • Experimental schemes that enable characterization of phase-change phenomena in the micro scale regime is essential for understanding the phase-change kinetics. Particularly, monitoring rapid vaporization on a submicron length scale is an important yet challenging task in a variety of laser-processing applications, including steam laser cleaning and liquid-assisted material ablation. This paper introduces a novel technique based on Michelson interferometry for probing the liquid-vaporization process on a solid surface heated by a KrF excimer laser pulse (${\lambda}=248nm,\;FWHM=24\;ns$) in water. The effective thickness of a microbubble layer has been measured with nanosecond time resolution. The maximum bubble size and growth rate are estimated to be of the order of $0.1{\mu}m\;and\;1\;m/s$, respectively. The results show that the acoustic enhancement in the laser induced vaporization process is caused by bubble expansion in the initial growth stage, not by bubble collapse. This work demonstrates that the interference method is effective for detecting bubble nucleation and microscale vaporization kinetics.

  • PDF

Filtration Characteristics of Metal Foam Filters for DPF Combined with Electrostatic Precipitation Mechanism (전기집진 기제를 조합시킨 DPF용 금속 폼 필터의 여과 특성)

  • Park, Seok-Joo;Lee, Dong-Geun;Kim, Jin-Hyun;Cho, Gyu-Baek;Kim, Hong-Suk;Jeong, Young-Il
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.151-158
    • /
    • 2007
  • Filtration studies, using simulated test nanoparticles or diesel nanoparticles, have been performed about Inconel foam filters for DPF combined with electrostatic precipitation. The simulated test particles were synthesized by laser ablation in the nitrogen atmosphere at the standard condition. The diesel particles were exhausted from the diesel engine driven on the condition of idle or load mode. Filtration efficiency of the metal foam filter is very low because most of particles are penetrated through the large pores of filter. However, the efficiency was considerably improved by applying the electric field to the filter and/or charging the nanoparticles. Nevertheless, the pressure drop of filter hardly increased because the filter-pores were not clogged by deposited particles and kept open.