Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles (외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도)

  • Kim, Chang-Yong;Choi, Jong-Duk;Kim, Suhn-Yeop;Oh, Duck-Won;Kim, Jin-Kyung
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.

Primary Conjunctival Mast Cell Tumor in a Korean Native Jindo Dog (진도견에서 발생한 원발성 결막 비만세포종양 1예)

  • Lee, Jae Yeon;Jeong, Seong Mok
    • Journal of Veterinary Clinics
    • /
    • v.30 no.2
    • /
    • pp.131-133
    • /
    • 2013
  • A 9-year-old, intact female Jindo dog weighing 23 kg was presented to the Veterinary Medical Teaching Hospital of Chungnam National University with a history of two months of ocular discharge. Initial ocular examination showed a 2 cm elongated mass arising from the ventral bulbar conjunctiva of the left eye. Ocular ultrasound, performed to rule out any orbital and intraocular involvement, was negative. Thoracic radiographs and abdominal ultrasonography revealed no abnormalities. Fine needle aspiration (FNA) of mass was performed. Aspiration cytology showed the presence of a round cell population mostly characterized. A moderate amount of eosinophils was present among round cells. The mass was excised and identified hitologically as a mast cell tumor. Six months after surgical treatment, thoracic radiographs and abdominal ultrasonography did not reveal any clinical signs of local recurrence or metastatic disease.

A Rare Case of Canine Huge Renal Cell Carcinoma with Ovarian Metastasis

  • Koo, Jiyoung;Song, Woo-Jin;Jo, Heesoo;Ahn, Hyerin;Choi, Solji;Jeong, Hyohoon;Cheong, Jongtae;Park, Hyun-Jung;Yun, Youngmin
    • Journal of Veterinary Clinics
    • /
    • v.39 no.4
    • /
    • pp.168-172
    • /
    • 2022
  • A 10-year-old female Pomeranian weighing 2.25 kg with a history of gradual weight loss and an intraabdominal mass confirmed with ultrasonography at a local hospital was referred to the Veterinary Medical Teaching Hospital, Jeju National University. Physical examination revealed abdominal distention. Blood analysis revealed hypoglycemia (57 mg/dL; reference range, 60-110 mg/dL). On abdominal ultrasonography, a heterogeneously hyperechoic mass measuring 7.51 × 10.6 cm was found at the level of the left kidney. Computed tomographic findings showed a unilateral left kidney mass with a 10-cm diameter and vessel contrast enhancement in the corticomedullary phase. Unilateral nephrectomy and ovariohysterectomy were performed because left ovary enlargement was observed during surgery. The renal mass was adjacent to the aorta and vena cava and attached to a portion of the small intestine, greater omentum, and left ovary. The mass was huge (12.5 × 10 × 7 cm) and was 16.5% of the body weight. Histopathological examination revealed renal cell carcinoma (RCC) and ovarian metastasis. After surgery, clinical signs improved remarkably, and serum glucose level returned to normal. As RCC is resistant to radiation and chemotherapy, the owner decided not to proceed with postoperative adjunctive therapies. To the best of our knowledge, this is the first case report of ovarian metastasis with huge RCC in a dog.

The Usefulness of Visceral Fat Thickness Measured by Ultrasonography as an Abdominal Obesity Index (초음파로 측정된 내장지방두께의 복부 비만지표로서의 유용성)

  • Kim, Yong-Kyun;Han, Man-Seok
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.249-258
    • /
    • 2008
  • Purpose : Abdominal obesity with visceral fat accumulation have been known to be intimately associated with the development of metabolic syndrome. Therefore, it is important to estimate the precise amount of visceral fat. Ultrasonography has been reported that it is a simple and noninvasive method for visceral fat evaluation. Purpose of this study is to evaluate the association of ultrasonographic visceral fat thickness, anthropometric indexes, and risk factor of metabolic syndrome, and to investigate the cut-off value of abdominal visceral fat thickness leading to increased risk of metabolic syndrome. Materials and methods : The subject included 200 men and 200 women who visited D healthcare center in Daejeon from January to April 2008. The subcutaneous fat thickness and visceral fat thickness were measured by ultrasonograph. As anthropometric index, we measured body mass index, waist circumference and waist/height ratio. As for the risk factor of metabolic syndrome, we measured blood pressure, high density lipoprotein cholesterol, triglyceride and fasting serum glucose. Results : VFT was significantly correlated with waist circumference, (r=0.683/M, r=0.604/F), waist to height ratio (r=0.633/M, r=0.593/F) and BMI (r=0.621/M, r=0.534/F) in both men and women. In addition it was significantly correlated with Systolic blood pressure (r=0.229/M, r=0.232/F), Diastolic blood pressure ((r=0.285/M, r=0.254/F), high density cholesterol (r=-0.254/M, r=-0.254/F), Triglyceride (r=0.475/M, r=0.411/F), and Fasting blood sugar (r=0.158/M, r=0.234/F) in both men and women. The cut-off value of visceral fat thickness leading to the increased risk of metabolic syndrome was 4.58cm (sensitivity89.2%, specificity 71.2%) in men and 3.50cm (sensitivity61.2% specificity 80.8%) in women respectively. The odds ratio of the risk of metabolic syndrome was dramatically increased with the abdominal visceral fat thickness level over 6cm in men and 5cm in women. Conclusion : The visceral fat thickness using ultrasonography was significantly correlated with anthropometric indexes and risk factors of metabolic syndrome in both men and women. The cut-off value of visceral fat thickness leading to the increased risk of metabolic syndrome was 4.58cm in men and 3.50cm in women.

  • PDF

Analysis of the Correlation Between Kidney Function Indicators and Kidney Size According Age Groups in Ultrasonography (신장 초음파 검사에서 연령대에 따른 신장 기능 지표와 신장 크기 간의 상관관계 분석)

  • Go, Ryo-won;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.871-879
    • /
    • 2020
  • The purpose of this study was to analysis the correlation between kidneys function indicators and these size in ultrasonography. A total of 170 (male:86, female:84) patients of sex and age groups were examined by abdominal ultrasonography. The patients classified as those in their 20's, 30's, 40's, and over 50's. We measured the length, width, and cross-sectional height of the kidneys twice. At this time, the length of these were measured from the maximum upper to the maximum lower pole and the widest width in the same ultrasonography was measured to obtain the cross-sectional area. Other relevant indicators included body surface area, serum creatinine, glomerular filtration rate (GFR), MDRD (Modification of diet in renal disease) and C-G (Cockcroft-Gault). Significant comparisons of differences between relevant factors by age groups and sex were conducted with a one-way distribution analysis. Correlation analysis was also performed between relevant factors by using Pearson and Spearman correlation coefficient. It was defined as meaningful when the p-value was less than 0.05. As a result, the length, the width, and the cross-sectional area of kidneys were correlated with GFR, C-G, MDRD. Therefore, it is expected that the accuracy of diagnosis of kidneys disease will be increased if the relevant indicators are evaluated together rather than measuring only length of these in ultrasonography.

FAST Reappraisal: Cross-sectional Study (혈역학적으로 안정된 복부둔상환자에서 FAST의 유용성 평가)

  • Ha, Sang Hyun;Hong, Chong Kun;Lee, Jun Ho;Hwang, Seong Youn;Choi, Seong Hee
    • Journal of Trauma and Injury
    • /
    • v.25 no.3
    • /
    • pp.67-71
    • /
    • 2012
  • Purpose: Focused Assessment with Sonography for Trauma (FAST) provides an important initial screening examination in adult trauma patients. However, due to its low sensitivity, FAST is not a replacement for computed tomography (CT) in hemodynamically stable trauma patients. The aim of this study was to determine the test characteristics of FAST in adult, hemodynamically stable, blunt abdominal trauma patients by using a critical action as a reference standard. Methods: The medical records for FAST examination at a single hospital from January 2009 to February 2011 were retrospectively reviewed. The inclusion criterion was isolated, hemodynamically stable, blunt abdominal trauma. Hemodynamically unstable patients or patients with penetrating injuries were excluded. The reference standard was the presence of a critical action, which was defined as one of the following: 1) operative intervention for a finding discovered on CT, 2) interventional radiology for bleeding, 3) transfusion of 2 or more packed RBCs, or 4) death at the emergency department. Results: There were 230 patients who met the inclusion criterion. There were 20 true positive, 206 true negative, 0 false positive, and 4 false negative results. The sensitivity and the specificity were 83% and 100%, respectively. Conclusion: Despite its low sensitivity for detecting any abnormal finding discovered on CT, negative FAST could aid to exclude critical action in hemodynamically stable, blunt abdominal trauma patients.

Comparative Effect of Modified Shrug Exercises With and Without Trunk Stabilization Exercise on Scapular Upward Rotator EMG and Thickness in Subjects With Scapular Downward Rotation Syndrome

  • Kim, Ji-hyun;Yoon, Hyeo-bin;Park, Joo-hee;Jeon, Hye-seon
    • Physical Therapy Korea
    • /
    • v.24 no.4
    • /
    • pp.60-67
    • /
    • 2017
  • Background: Scapular downward rotation syndrome (SDRS) is a common scapular alignment impairment that causes insufficient upward rotation and muscle imbalance, shortened levator scapulae (LS) and rhomboid, and lengthened serratus anterior (SA) and trapezius. A modified shrug exercise (MSE), performing a shrug exercise with the shoulders at $150^{\circ}$ abduction, is known as an effective exercise to increase scapular stabilizer muscle activation. Previous studies revealed that scapular exercise are more effective when combined with trunk stabilization exercises in decreasing scapular winging and increasing scapular stabilizer muscle activation. Objects: The purpose of our study was to clarify the effect of MSE with or without trunk stabilization exercises in subjects with SDRS. Methods: Eighteen volunteer subjects (male=10, female=8) with SDRS were recruited for this experiment. All subjects performed MSE under 3 different conditions: (1) MSE, (2) MSE with an abdominal draw-in maneuver (ADIM), and (3) MSE with an abdominal expansion maneuver (AEM). The muscle thickness of the lower trapezius (LT) and the SA were measured using an ultrasonography in each condition. Electromyography (EMG) data were collected from the LT, LS, SA, and upper trapezius (UT) muscle activities. Data were statistically analysed using one-way repeated analysis of variance at a significance level of .05. Results: The muscle thickness of the LT and the SA were the significant different in the MSE, MSE with ADIM (MSE+ADIM) and MSE with AEM (MSE+AEM) conditions (p<.05) In both LT and SA, the order of thick muscle thickness was MSE+AEM, MSE+ADIM, and MSE alone. No significant differences were found in the EMG activities of the SA, UT, LS, and LT in all condition. Conclusion: In conclusion, MSE is more beneficial to people with SDRS when combined with trunk stabilization exercises by increased thickness of scapular stabilizer muscles.

Evaluation of Normal Abdominal Organs by Diagnostic Imaging in the Premature Miniature Pig (미성숙 미니돼지에서 방사선과 초음파를 이용한 복부장기의 평가)

  • Chang, Jin-Hwa;Jung, Joo-Hyun;Oh, Sun-Kyoung;Choi, Min-Cheol
    • Journal of Life Science
    • /
    • v.19 no.3
    • /
    • pp.417-421
    • /
    • 2009
  • This report describes the normal radiographic and ultrasonographic morphological features of premature minipigs at 4, 8, 12 and 20 weeks of age. Radiographic examination is a simple diagnostic method used to identify the general morphologic state of major organs and their adjacent structures, and to assess the presence of abnormalities. The parameters for evaluation in plain abdominal radiographs are the degree of diffuse serosal margin details, extent of visualization of each organ, their size, shape, and contour, locations of main organs - such as the liver, stomach, spleen, kidneys, urinary bladder - the distribution of the intestines, and assessment of the retroperitoneal space and its contents. Ultrasonographic examinations are used to investigate their internal condition. The parameters for evaluation in abdominal ultrasonography are echogenicity, echotexture, and size and shape of the main organs such as the liver, spleen, kidney, urinary bladder and gastrointestinal tract. Minipigs had similar findings compared to dogs or cats.

Effects of Different Sitting Postures on Transverse Abdominis Muscle Thickness and Sitting Balance in Children With Cerebral Palsy (다른 앉은 자세가 뇌성마비 환자의 복횡근 두께와 앉기 균형에 미치는 영향)

  • Yun, Chang-Kyo;Kim, Won-Bok
    • Physical Therapy Korea
    • /
    • v.21 no.3
    • /
    • pp.11-19
    • /
    • 2014
  • The purpose of this study was to investigate the activity of the transverse abdominal muscle resulting from changed posture by measuring the thickness of the transverse abdominal muscle in a supine posture, a slouched sitting posture, and an erect sitting posture. The subjects of the study were 28 patients with cerebral palsy. All their transverse abdominal muscles at the end of inhalation were measured at supine, slouched sitting (S sitting) and erect sitting (E sitting) postures by using ultrasonography, and then their dynamic sitting balance was measured at S sitting and E sitting postures by using BioRescue. For the statistical analysis, the Kruskal-Wallis test and the Wilcoxon signed-rank test were used to compare the differences among each the postures. The results were as follows. The thickness of the transverse abdominal muscle when comparing the supine posture and the S sitting posture showed no statistically significant difference. But the E sitting posture showed a statistically significant difference as compared with the others. In addition, the dynamic sitting balance in comparing the S sitting and E sitting postures showed a significant difference. In conclusion, the E sitting posture has a more positive effect on postural control and balance than generally taking the S sitting posture, for the sitting posture of a patient with cerebral palsy. It is suggested that patients with cerebral palsy mainly experiencing a sedentary life or being in a wheelchair should be seated in the E sitting posture during their daily life, and it may be necessary to continue to monitor and manage the proper E sitting posture.

Computed Tomographic Features of Blunt Abdominal Trauma in a Dog (개에서 컴퓨터단층촬영을 이용한 복부 장기 열상 진단 1례)

  • Park, Hyun-young;Seo, Ji-won;Lee, Young-won;Choi, Ho-jung
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.39-42
    • /
    • 2016
  • A 10 months old, male Poongsan dog was referred with a history of right forelimb lameness due to hit by a car a few hours before presentation. On the physical examination, the dog showed pale mucous membrane, respiration distress, and skin abrasions. The main laboratory finding was leukocytosis, while hematocrit was normal. Abdominal radiography revealed the loss of abdominal serosal detail, which was diagnosed as peritoneal hemorrhage on ultrasonography (US) and aspiration. On computed tomography (CT), hepatic and splenic injuries were seen characterized by the discontinuity of the capsule with irregular margin and lower density lesions than parenchyma. No contrast enhancing area were shown in the laceration lesion. The accessory spleen was incidentally found by US and CT. In this case, acute intra-abdominal hemorrhage from splenic and hepatic laceration was diagnosed using CT.