• Title/Summary/Keyword: aPTT

Search Result 247, Processing Time 0.03 seconds

Analysis of Change Rate of SBP and DBP Estimation Fusion Algorithm According to PTT Measurement change PPG Pulse Wave Analysis (PPG 맥파 분석의 PTT 측정변화에 따른 SBP, DBP 추정 융합 알고리즘 변화율 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.7
    • /
    • pp.35-40
    • /
    • 2020
  • Recently, devices such as smart watches capable of measuring small biosignals have been released. Body composition, blood pressure, heart rate, and oxygen saturation can be easily obtained. However, the part that is not trusted by the user is accuracy. These biosignals are sensitive to the external environment and have large fluctuations depending on the conditions inside the subject's body. Blood pressure measurements, in particular, still give different results, depending on how the conditions in the body are handled. Therefore, in this study, PPG was analyzed to measure PTT at two points of 80% and 100%, the highest in PTT measurement. The effect of the measured value on SBP and DBP was analyzed and a method was proposed to increase the accuracy. As a result of the study, the measured value of PTT at 80% of the peak PPG is more effective in estimating blood pressure of SBP and DBP than the value measured at 100%. In the regression analysis of the rate of change blood pressure estimation, the coefficient of determination of SBP (80%) was 0.6946, and DBP (100%) was 0.547.

Malignant Proliferating Trichilemmal Tumor - A Case Report - (악성 증식성 모낭 종양 - 증례 보고 -)

  • Hong, Ki-Do;Kim, Jae-Young;Ha, Sung-Sik;Sim, Jae-Chun;Cho, Hye-Jae;Choi, Yoon-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.15 no.1
    • /
    • pp.65-68
    • /
    • 2009
  • Proliferating trichilemmal tumor(PTT) is a rare neoplasm derived from the outer root sheath of the hair follicle. Malignant transformation is rare, but abrupt enlargement of size, infiltrative growth, and non-scalp location are suggestive of malignant PTT. Histopathologic characteristics of malignant PTT are nuclear atypia, pleomorphism, and mitotic figures. Recurrence and metastasis have been documented in malignant PTT. Wide resection of the tumor with the normal tissue and accurate follow-up is the treatment of choice of the both malignant and benign PTT. We report a 51-year-old man with the mass on right 5th finger distal phalanx for 7 years. The tumor was excised with middle phalangiectomy, and based on the histopathologic findings of the tumor, this case was diagnosed as mailignant PTT. We cannot detect recurrence and metastasis because the patient was lost to follow-up.

  • PDF

Design and Implementation of a PoC System (PoC 시스템의 설계 및 구현)

  • Kim, Kyu-Yeon;Kim, Jin-Man;Shin, Dong-Ryeol
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.1537-1540
    • /
    • 2005
  • PTT 서비스란 무전기처럼 Half-duplex 통신에서 사용하는 방식으로 말하고자 하는 사람이 PTT 버튼을 눌러 그 권한을 얻은 후에야 말을 할 수 있는 일종의 그룹 통화 방식이다. 본 논문에서는 이동통신망에서 데이터 서비스의 하나로서 VoIP 에 기반한 PTT 서비스 및 부가 서비스를 구현하기 위한 구조를 제시할 뿐만 아니라, PTT 서비스를 위한 논리적 구성 요소인 서버 및 단말 등의 기능을 설계하고, 각 구성요소를 통한 각종 서비스 제어 알고리즘을 구현한다.

  • PDF

Physical Property of PTT/Wool/Modal Air Vortex Yarns for High Emotional Garment (고감성 의류용 PTT/울/모달 에어 볼텍스 복합사의 물성)

  • Kim, Hyunah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.39 no.6
    • /
    • pp.877-884
    • /
    • 2015
  • Polytrimethylene Terephthalate (PTT) is an eco-fiber with good elastic properties; however, it requires more detailed studies related to spinnability according to blending of various kinds of fibers. The evolution of spinning technology was focused on improved productivity with good quality; in addition, air vortex spinning was recently invented and applied on the spinning factory as the facility with good productivity and quality. More detail spinning technology according to the blending of various kinds of fibers on the air vortex spinning system is required to obtain good quality yarns for high emotional fabrics. In this paper, the physical properties of air vortex, compact and ring staple yarns using PTT/wool/modal blend fibers were investigated with yarn structure to promote high functional PTT that includes fabrics for high emotional garments. Unevenness of air vortex yarns was higher than those of compact and ring yarns; in addition, imperfections were greater than those of compact and ring yarns, which was attributed to a fascinated vortex yarn structure. Tenacity and breaking strain of air vortex yarns were lower than those of compact and ring yarns, caused by higher unevenness and more imperfections of air vortex yarns compared to compact and ring yarns. Vortex yarns showed the highest initial modulus and ring yarns showed the lowest ones which results in a stiff tactile feeling of air vortex yarns in regards to the initial modulus of yarns. Dry and wet thermal shrinkages of air vortex yarns were lower than ring yarns. Good shape retention of vortex yarns was estimated due to low thermal shrinkage.

Safety of low-dose anticoagulation in extracorporeal membrane oxygenation using the Permanent Life Support System: a retrospective observational study

  • Kyungsub Song;Jae Bum Kim
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.3
    • /
    • pp.276-282
    • /
    • 2023
  • Background: Bleeding and thrombosis are major complications associated with high mortality in extracorporeal membrane oxygenation (ECMO) management. Anticoagulant therapy should be adequate to reduce thrombosis. However, related studies are limited. Methods: We retrospectively reviewed all patients supported with ECMO at a single institution between January 2014 and July 2022 and included those on all types of ECMO using the Permanent Life Support System. Patients were classified into two groups according to their measured mean activated partial thromboplastin time (aPTT) during ECMO management: a high-anticoagulation (AC) group (aPTT, ≥55 seconds; n=52) and a low-AC group (aPTT, <55 seconds; n=79). The primary outcome was thrombotic or bleeding events during ECMO. Results: We identified 10 patients with bleeding; significantly more of these patients were in the high-AC group (n=8) than in the low-AC group (15.4% vs. 2.5%, p=0.01). However, thrombus events and oxygenator change-free times were not significantly different between the two groups. Four patients in the high-AC group died of bleeding complications (brain hemorrhage, two; hemopericardium, one; and gastrointestinal bleeding, one). One patient in the low-AC group developed a thrombus and died of ECMO dysfunction due to circuit thrombosis. Conclusion: Heparin did not significantly improve thrombotic outcomes. However, maintaining an aPTT of ≥55 seconds was a significant risk factor for bleeding events, especially those associated with mortality.

Evaluation of the Burning Properties of Various Carpet Samples by using the Cone Calorimeter and Gas Toxicity Test (콘칼로리미터와 가스유해성 시험법을 이용한 카페트류의 연소특성 평가)

  • Lee, Bong-Woo;Kwon, Seong-Pil;Lee, Jang-Won;Lee, Byoung-Ho;Kim, Hee-Soo;Kim, Hyun-Joong
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.1-9
    • /
    • 2009
  • In this study, the burning behaviours of five different kinds of carpet samples covered with nylon, PP (polypropylene), PTT (poly(trimethylene terephthalate)), wool fabric and NW (nylon and wool) were evaluated by using the cone calorimeter having a radiant flux of 50kW/$m^2$. And the combustion gas toxicity was evaluated according to KS F 2271 test method. As a result of the cone calorimeter test (KS F ISO 5660-1), nylon carpet samples were ignited most easily. In ignition ability or initial flammability, NW carpet samples showed the highest value. In heat release rate (HRR), fire intensity, PP carpet samples were larger than any other samples. Nylon carpet samples were the highest smoke production rate, while N/W carpet samples the lowest. The following were in mass loss rates: NW > wool > nylon > PP > PTT. CO (carbon monoxide) was one of the most toxic gases released from the combustion. PTT carpet samples gave rise to the highest CO concentration, while NW carpet samples the lowest. In addition, PP carpet samples caused the highest $CO_2$ (carbon dioxide) concentration, while NW carpet samples the lowest. Toxicity of the gas produced from carpet samples was determined by the mouse stop motion, and it resulted in the fact that the combustion gas of PTT carpet samples was more toxic than that of any other samples.

Structure Development in Drawn Poly(trimethylene terephthalate) (연신에 의한 폴리(트리메틸렌 테레프탈레이트)의 구조 변형)

  • 전병환;김환기;강호종
    • Polymer(Korea)
    • /
    • v.27 no.5
    • /
    • pp.477-483
    • /
    • 2003
  • The structure development of drawn poly(trimethylene terephthalate) PTT as a function of draw down ratio and drawing temperature was studied. The special effort was made to find out the effect of structural development on thermal properties and crystallinity in drawn PTT. The changes in shrinkage ratio and mechanical properties were understood base on the level of crystallinity and orientation of the drawn PTT. The stress induced crystallization caused the increase in glass transition temperature and the decrease in cold crystallization temperature and enthalpy. The crystallinity and orientation were dependent upon the level of applied stress level as well as chain flexibility at high drawing temperature. The drawing resulted in the increase of shrinkage ratio but it was minimized by increasing of crystallinity. The development of orientation resulted in increasing modulus and tensile strength while decreasing elongation at break.

A Study of Ultrasound Rehabilitation Therapy: Physiological Effects by Change of Ultrasound Intensity (초음파 치료 시 초음파 세기 변화에 따른 생리적 효과 연구)

  • Kim, S.M.;Lee, M.P.;Choi, B.C.;Choi, S.H.;Bae, H.S.;Jung, H.S.;Park, S.Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.1
    • /
    • pp.40-45
    • /
    • 2008
  • Therapeutic ultrasound which is developed for rehabilitation therapy have already been used for healing joint contracture, synechia, acute and chronic inflammatory diseases. Medical devices for pain-relief and healing using therapeutic ultrasound are actively being developed. This study measured the change of PTT with the transmitted ultrasound through the human body to find out the increase of compliance of blood vessels. Measurement method of PTT in this study is employed as useful ways to acquire physiological information of patients in the clinical case in order to measure the change of mechanical characteristics of blood vessels. This study confirmed the PTT change of rehabilitation patients through the thermal effects of ultrasound by using PTT and also found that it is possible to increase PTT by adjusting the warm water and ultrasound. The increase of PTT means the decrease of the pulse wave velocity from the cardiovascular system to the peripheral arteries. The physiological effects occurred using the warm water and ultrasound.

A Study of Factor XII Deficiency in Recurrent Spontaneous Abortion (반복자연유산에서 12번 응고인자 결핍증에 대한 연구)

  • Nam, Yoon-Sung;Kim, Nam-Keun;Lee, Su-Man;Kang, Myung-Seo;Oh, Do-Yeon;Cha, Kwang-Yul
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.28 no.3
    • /
    • pp.209-213
    • /
    • 2001
  • Objective : To evaluate factor XII deficiency in patients with recurrent spontaneous abortion and its relation to aPTT. Material and Method: Factor XII was analyzed by clotting method. Results: Of 70 patients with recurrent spontaneous abortion, there were 35 cases of factor XII deficiency. Among them, there were only 3 cases of prolonged aPTT. Conclusions: It is still unclear whether factor XII deficiency is related to recurrent spontaneous abortion. Molecular approaches should be used to understand further the causal relationship. But based on this result, in the workup of patients with recurrent spontaneous abortion, factor XII should be included. aPTT is not likely to represent the abnormality of factor XII.

  • PDF

Estimation of Non- Invasive Blood Pressure Using Peripheral Plethysmograph (말초혈관 혈류 측정을 이용한 비관혈적 혈압 추정법에 대한 연구)

  • Jeong In-cheol;Shin Tae-min;Yoon Hyung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.8
    • /
    • pp.504-509
    • /
    • 2005
  • This paper presents a new method for obtaining the noninvasive and unrestrained blood pressure readings noninvasively and unrestrainedly using based on reflected wave arrival time(RAT) in the volume of pulse. Since this new method employs only volume pulse, is more rapider and simpler than the method using pulse transit time(PTT) because it only employs the volume of pulse. Blood pressure, PTT and RAT were acquired from 15 healthy subjects. Each subjects were performed forty trials of each measurement. As a result of those trials, the mean error between oscillometric and RAT measurements for systolic blood pressure was $4.55\pm5.64mmHg$. This result showed quite equal with the mean error between oscillometric and PPT measurf:ments, $4.22\pm5.30mmHg$, However, it was not obtained a satisfactory result in the relativity of oscillometric to both RAT and PPT measurements for diastolic blood pressure because of personal difference. To conclude, the method of systolic blood pressure estimation noninvasively and unrestrainedly using by RAT may be used as the method by PTT. Nevertheless, additional studies would be necessary for the RAT/PTT estimation of diastolic blood Pressure measurement.