• 제목/요약/키워드: a xenon lamp

검색결과 90건 처리시간 0.032초

Development portable hair removal applies PET ($Pause^{10-90}$ and $Energy^{20-40}$ $Trigger^{1-7}$) function

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • 제7권2호
    • /
    • pp.223-230
    • /
    • 2009
  • For pulse trigger way and the energy injection rate according to PET ($Pause^{10-90}$ $Energy^{20-40}$ $Trigger^{1-7}$) function, indeed, human body condition, period of dormancy in this research about this back correctly adjustment possible and designed harmless micro carrying along style hair exclusion so that can design and manufacture and run special quality examination and Xenon flash lamp to crawl in human body. Because creating individual's skin model to do stable treatment by light transmission way by skin impedance and measure, must embody treatment special quality of most suitable that draw skin color, energy, wave length, approximately, transmission time, pulse delay etc. and want. Specially, saved standard of war treatment pulse modeling by skin impedance, and manufacture pulse modeling system of most suitable by skin subordinate, and embody suitable treatment pulse. Specially, embody as could do root of a hair exclusion being emitted in pulse form using multi wave length of 560nm, 590nm, 640nm, 755nm and embodied clinical data. If become research repletion furthermore little more, is seen that can approximate in commercialization.

자동차 조명장치용 고압 방전등 시스템의 특성해석에 관한 연구 (A Study on the Characteristics Analysis of Automotive Ballast System)

  • 이두호;김병우
    • 한국산학기술학회논문지
    • /
    • 제12권9호
    • /
    • pp.3795-3801
    • /
    • 2011
  • 자동차 방전 램프의 전압과 전류에 대한 수학적 해석은 고전압 안정기 해석 및 설계에 유용하게 활용된다. 본 논문에서는 자동차 방전 램프에서 발생되는 램프 전력과 음극 전압 강하 현상에 대한 수학적 모델을 제안하였다. 제안된 모델에 적용된 수치해석 알고리즘을 구현하였고 여기에서 발생된 해석결과는 실험과 비교 검토하였다. 또한, 본 논문에서는 설계 기반의 해석방법을 적용하여 자동차용 고전압 안정기 핵심 부품에 대한 설계 인자를 도출하였다.

Surface Discharge Characteristics of New Flat Fluorescent Lamp Enhanced by MgO Nano-Crystals

  • Lee, Yang-Kyu;Heo, Seung-Taek;Lee, You-Kook;Lee, Dong-Gu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.687-690
    • /
    • 2009
  • It has been recently reported that nano-sized MgO single crystal powders emit ultraviolet by stimulation of electrons under vacuum condition. Therefore, in this study, nano-crystalline MgO powders were applied to a xenon plasma flat fluorescent lamp for LCD backlight to improve emission efficiency of the lamp by help of extra ultraviolet from nano-MgO. For comparison with nano-crystalline MgO powders, MgO nano-thin film was applied directly on phosphors inside a lamp panel through e-beam evaporation The luminance and efficiency of FFL with an addition of MgO nano-crystal powders on phosphors were improved by around 20%. Application of MgO thin film to phosphors worsened the emission characteristics of FFLs, even rather than FFL without MgO. The reason came from insufficient stimulation of phosphors by UV, crystallinity of MgO, and low secondary electron coefficient.

  • PDF

방전램프의 광질에 따른 상추의 생장 및 파이토케미컬 분석 (Growth and Phytochemicals of Lettuce as Affected by Light Quality of Discharge Lamps)

  • 이재수;남상운;김용현
    • 생물환경조절학회지
    • /
    • 제22권4호
    • /
    • pp.400-407
    • /
    • 2013
  • 본 연구는 식물공장용으로 방전램프로서 메탈할라이드램프(MH), 고압나트륨램프(HPS), 제논램프(XE)를 사용하고, 냉백색형광등(FL)을 대조구로 사용한 가운데 상추(Lactuca sativa L. cv. Jeokchima)의 생육 및 파이토케미컬의 특성을 분석하고자 수행되었다. 식물공장 내부의 환경조건은 광주기 16/8h, 광합성유효광양자속(photosynthetic photon flux, PPF) $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, 기온 $22/18^{\circ}C$, 습도 70%, $CO_2$ 농도 $400{\mu}mol{\cdot}mol^{-1}$로 조절하였다. 각 램프의 분광 특성을 이용하여 PPF에 대한 청색광 영역(400~500nm), 녹색광 영역(500~600nm), 적색광 영역(600~700nm)의 비율을 계산하였다. MH램프의 청색광 영역은 23.0%로서 다른 처리구에 비해서 가장 높게 나타났다. 한편 HPS램프의 청색광 영역은 4.7%로서 가장 낮게 나타났으나, 적색광 영역은 38.0%로서 다른 처리구에 비해서 높게 나타났다. 정식 후 11일째와 21일째에 측정된 상추의 엽장, 엽폭, 엽면적, 지상부 생체중 및 건물중은 방전램프의 광질에 따른 유의차가 나타날 정도로 다르게 나타났다. HPS 처리구의 엽면적은 $143,486mm^2$로서 대조구의 $98,474mm^2$에 비해서 45.7% 크게 나타났으며, MH와 XE 처리구는 대조구에 비해서 각각 16.3%, 9.5%로 크게 나타났다. 이러한 결과는 지상부 생체중에서도 유사하게 나타났다. 적색광 영역의 비율이 높은 HPS 처리구에서는 상추의 잎 관련 생장 특성에서 최대치가 나타났으나, 청색광 영역의 비율이 높은 MH와 XE 처리구에서는 낮게 나타났다. 방전등 처리구에 따라 상추 잎에 축적된 아스코르빈산 함량은 대조구에 비해서 작게 나타났으며, 처리구 사이에 유의차가 인정되지 않았다. 상추 잎의 안토시아닌 함량은 MH 처리구에서 0.70mg/100g으로 최대치가 나타났으며, XE와 HPS 처리구는 대조구의 0.58mg/100g에 비해서 각각 79.3%, 8.6%수준이었다. 결과적으로 방전램프의 종류에 따라 상추의 생장 특성, 아스코르빈산 및 안토시아닌 함량이 다르게 나타났다. 따라서 식물공장용 인공광원으로서 방전램프를 효율적으로 활용하면서, 상추의 생장 및 파이토케미컬 함량을 증진시키기 위해서는 분광 특성이 상이한 방전램프의 병용 또는 단색광 LED의 추가 설치 등과 같은 방전램프의 광질 개선이 요구된다.

자외선 및 가시광선에 의한 염색시료의 변퇴색 (Color Change of the Dyed Materials by Ultra-Violet and Visible Irradiation)

  • 김홍범;한종성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1995년도 추계학술발표회논문집
    • /
    • pp.13-18
    • /
    • 1995
  • To evaluate the color change of the dyed materials by ultraviolet and visible rays in the museum, a system that accelerates dye fading was developed. Radiation energy from a Xenon lamp is irradiated on the samples through the filters of defferent cut-on wavelengths. As a result, the color change as a function of the wavelength and irradiation is calculated.

  • PDF

Development of On -Line Work Roll Surface Monitoring System At Hot Strip Mill

  • Moon, Bae-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.53.4-53
    • /
    • 2001
  • This paper described about the system which can be inspect work roll surface for deciding a milling schedule and roll changing at hot strip mill in POSCO. Developed system consists of CCD camera, Xenon lamp with fiber bundle and mechanical control part. The water probe build up water pole between head of probe and roll surface to acquisite a good image from a work roll surface under the bad environment with steam, cooling water and high temperature. This system is possible to monitor a work roll surface of about 12${\times}$9mm. We have shown the validation of the developed system which can monitor the evolution of degradation on work roll surface.

  • PDF

불투명 수지재료의 복사에너지에 의한 변색 측정 (Measurement of Color Change of Opaque Resin Materials by Radiation Energy)

  • 한종성;김홍범;김훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1998년도 학술발표회논문집
    • /
    • pp.138-141
    • /
    • 1998
  • To evaluate the color change of the opaque resin materials, a measuring system including PAS(photodegradation acceleration system) was constructed. Xenon lamp is used as a light source in the PAS, and the radiant energy from the lamp is irradiated to the samples through serveral high-pass filters with cut-off wavelength in UV and visible region. The color difference of the samples were measured by using the measuring system with a spectrophotometer(CM-2002) and a computer. The result showed that the opaque resin materials changed severely in their color in the wavelength of UV region and changed a little in the wavelength of visible region.

  • PDF

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

Pulse Density Modulated Zero Voltage Soft-Switching High-Frequency Inverter with Single Switch for Xenon Gas Dielectric Barrier Discharge Lamp Dimming

  • Sugimura, Hisayuki;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.391-394
    • /
    • 2006
  • This paper presents soft switching zero voltage switching high frequency inverter for rare gas fluorescent lamp using dielectric-barrier discharge phenomenon. The simple high-frequency inverter can completely achieve stable zero voltage soft switching (ZVS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZVS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this high frequency Inverter are illustrated as compared with computer simulation results and experimental ones. Its light dimming characteristics due to power regulation scheme are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proven from the practical point of view.

  • PDF

Study on the Design of a High Condensing LED Searchlight

  • Kim, Tae-Seong;Kim, Jin-Wook;Kim, Sun-Jae;Kil, Gyung-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권4호
    • /
    • pp.201-205
    • /
    • 2015
  • This paper dealt with the condensing technology of an LED light source that uses a parabolic reflector to replace a searchlight equipped with a xenon lamp. A ray-tracing simulation was conducted to analyze the influence of the diameter of the reflector and the size of the light source on light condensing. The combination of a parabolic reflector with a diameter of 620 mm and a focal distance of 220 mm, and a 9 mm multi-chip package (MCP) with a luminous flux of 7,000 lm showed the narrowest beam angle. The luminous intensity at the center was measured at 7.7×106 cd. The distance between the light source and the point where the illuminance was 1 lx was calculated to be 2.8 km. The power consumption of the system was 95 W, which is only 9.5% of that of the 1 kW xenon searchlight, and the beam angle was 1.03°. In a site experiment, it was confirmed that the light ray reflected from the LED searchlight proceeds forward without any diffusion because of the narrow beam angle.