• 제목/요약/키워드: a steel plate concrete wall

검색결과 82건 처리시간 0.021초

Shear strength of connections between open and closed steel-concrete composite sandwich structures

  • Kim, Woo-Bum;Choi, Byong Jeong
    • Steel and Composite Structures
    • /
    • 제11권2호
    • /
    • pp.169-181
    • /
    • 2011
  • The behavior of connections between open sandwich slabs and double steel skin composite walls in steel plate-concrete(SC) structure is investigated by a series of experimental programs to identify the roles of components in the transfer of forces. Such connections are supposed to transfer shear by the action of friction on the interface between the steel surface and the concrete surface, as well as the shear resistance of the bottom steel plate attached to the wall. Experimental observation showed that shear transfer in slabs subjected to shear in short spans is explained by direct force transfer via diagonal struts and indirect force transfer via truss actions. Shear resistance at the interface is enhanced by the shear capacity of the shear plate as well as friction caused by the compressive force along the wall plate. Shear friction resistance along the wall plate was deduced from experimental observation. Finally, the appropriate design strength of the connection is proposed for a practical design purpose.

Evaluation of unilateral buckling of steel plates in composite concrete-steel shear walls

  • Shamsedin Hashemi;Samaneh Ramezani
    • Structural Engineering and Mechanics
    • /
    • 제88권2호
    • /
    • pp.129-140
    • /
    • 2023
  • To increase the stiffness and strength of a reinforced concrete shear wall, steel plates are bolted to the sides of the wall. The general behavior of a composite concrete-steel shear wall is dependent on the buckling of the steel plates that should be prevented. In this paper, the unilateral buckling of steel plates of a composite shear wall is studied using the Rayleigh-Ritz method. To model the unilateral buckling of steel plate, the restraining concrete wall is described as an elastic foundation with high stiffness in compression and zero stiffness in tension. To consider the effect of bolt connections on the plate's buckling, a constrained optimization problem is solved by using Lagrange multipliers method. This process is used to obtain the critical elastic local buckling coefficients of unilaterally-restrained steel plates with various numbers of bolts, subjected to pure compression, bending and shear loading, and the interaction between them. Using these results, the spacing between shear bolts in composite steel plate shear walls is estimated and compared with the results of the AISC seismic provisions (2016). The results show that the AISC seismic provisions(2016) are overly conservative in obtaining the spacing between shear bolts.

SC(강판-콘크리트)구조 브라켓 접합부 거동에 관한 연구 (A Study on the Behavior of Wall-Support Joint of Steel Plate-Concrete Structure)

  • 김우범;김강식
    • 한국강구조학회 논문집
    • /
    • 제16권3호통권70호
    • /
    • pp.377-385
    • /
    • 2004
  • 본 논문에서는 강판-콘크리트 벽체구조에 부착되는 기기를 지지하기 위하여 설치되는 지지대와 벽채와의 접합 성능을 파악하기 위하여 구조실험 및 유한요소해석을 수행하였다. 구조실험은 9개의 시험체를 제작하여 파괴모드 및 최대내력을 파악하였으며 유한요소해석모델을 작성하여 이를 실험결과와 비교 검증한 후 강판두께, 스터드 볼트 간격, 지지대의 위치 및 크기 등의 영향인자가 벽체 접합부의 거동 및 내력에 미치는 변화를 살펴보았다. 해석 시험체의 하중-변형의 관계로부터 시험체의 항복내력 및 최대내력을 정의 하였으며 향후 항복선 해석을 위한 토대를 마련하였다.

현장끼움벽으로 보강된 철근콘크리트 골조의 비선형 유한요소해석 (A Nonlinear Finite Element Analysis to Reinforced Concrete Frame Retrofitted with Cast-In Plate Infilled Shear Wall)

  • 한민기;이혜연;김선우;이갑원;최창식;윤현도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.73-76
    • /
    • 2005
  • This paper discussed finite element method(FEM) models of the reinforced concrete frame retrofitted with cast-in plate infilled shear wall and analysed under constant axial and monotonic lateral load using ABAQUS. Detailed finite element models are created by studying the monotonic load response of the designed connection of reinforced concrete frame and cast-in plate infilled shear wall. The developed models account for the effect of material inelasticity, concrete cracking, geometric nonlinearity and bond-slip of steel, frame and infilled shear wall. In order to verify the proposed FEM, this study behaved analysis considered a diagonal reinforced steel. The analytical results compared with the experimental results.

  • PDF

Experimental study on shear, tensile, and compression behaviors of composite insulated concrete sandwich wall

  • Zhang, Xiaomeng;Zhang, Xueyong;Liu, Wenting;Li, Zheng;Zhang, Xiaowei;Zhou, Yilun
    • Advances in concrete construction
    • /
    • 제11권1호
    • /
    • pp.33-43
    • /
    • 2021
  • A new type of composite insulated concrete sandwich wall (ICS-wall), which is composed of a triangle truss steel wire network, an insulating layer, and internal and external concrete layers, is proposed. To study the mechanical properties of this new ICS-wall, tensile, compression, and shearing tests were performed on 22 specimens and tensile strength and corrosion resistance tests on 6 triangle truss joints. The variables in these tests mainly include the insulating plate material, the thickness of the insulating plate, the vertical distance of the triangle truss framework, the triangle truss layout, and the connecting mode between the triangle truss and wall and the material of the triangle truss. Moreover, the failure mode, mechanical properties, and bearing capacity of the wall under tensile, shearing, and compression conditions were analyzed. Research results demonstrate that the concrete and insulating layer of the ICS-wall are pulling out, which is the main failure mode under tensile conditions. The ICS-wall, which uses a graphite polystyrene plate as the insulating layer, shows better tensile properties than the wall with an ordinary polystyrene plate. The tensile strength and bearing capacity of the wall can be improved effectively by strengthening the triangle truss connection and shortening the vertical distances of the triangle truss. The compression capacity of the wall is mainly determined by the compression capacity of concrete, and the bonding strength between the wall and the insulating plate is the main influencing factor of the shearing capacity of the wall. According to the tensile strength and corrosion resistance tests of Austenitic stainless steel, the bearing capacity of the triangle truss does not decrease after corrosion, indicating good corrosion resistance.

LOCAL COLLISION SIMULATION OF AN SC WALL USING ENERGY ABSORBING STEEL

  • Chung, Chul-Hun;Choi, Hyun;Park, Jaegyun
    • Nuclear Engineering and Technology
    • /
    • 제45권4호
    • /
    • pp.553-564
    • /
    • 2013
  • This study evaluates the local damage of a turbine in an auxiliary building of a nuclear power plant due to an external impact by using the LS-DYNA finite element program. The wall of the auxiliary building is SC structure and the material of the SC wall plate is high manganese steel, which has superior ductility and energy absorbance compared to the ordinary steel used for other SC wall plates. The effects of the material of the wall, collision speed, and angle on the magnitude of the local damage were evaluated by local collision analysis. The analysis revealed that the SC wall made of manganese steel had significantly less damage than the SC wall made of ordinary steel. In conclusion, an SC wall made of manganese steel can have higher effective resistance than an SC wall made of ordinary steel against the local collision of an airplane engine or against a turbine impact.

Compressive behavior of profiled double skin composite wall

  • Qin, Ying;Li, Yong-Wei;Su, Yu-Sen;Lan, Xu-Zhao;Wu, Yuan-De;Wang, Xiang-Yu
    • Steel and Composite Structures
    • /
    • 제30권5호
    • /
    • pp.405-416
    • /
    • 2019
  • Profiled composite slab has been widely used in civil engineering due to its structural merits. The extension of this concept to the bearing wall forms the profiled composite wall, which consists of two external profiled steel plates and infill concrete. This paper investigates the structural behavior of this type of wall under axial compression. A series of compression tests on profiled composite walls consisting of varied types of profiled steel plate and edge confinement have been carried out. The test results are evaluated in terms of failure modes, load-axial displacement curves, strength index, ductility ratio, and load-strain response. It is found that the type of profiled steel plate has influence on the axial capacity and strength index, while edge confinement affects the failure mode and ductility. The test data are compared with the predictions by modern codes such as AISC 360, BS EN 1994-1-1, and CECS 159. It shows that BS EN 1994-1-1 and CECS 159 significantly overestimate the actual compressive capacity of profiled composite walls, while AISC 360 offers reasonable predictions. A method is then proposed, which takes into account the local buckling of profiled steel plates and the reduction in the concrete resistance due to profiling. The predictions show good correlation with the test results.

Seismic behavior of energy dissipation shear wall with CFST column elements

  • Su, Hao;Zhu Lihua;Wang, Yaohong;Feng, Lei;Gao, Zeyu;Guo, Yuchen;Meng, Longfei;Yuan, Hanquan
    • Steel and Composite Structures
    • /
    • 제43권1호
    • /
    • pp.55-66
    • /
    • 2022
  • To develop high-efficiency lateral force resistance components for high-rise buildings, a novel energy dissipation shear wall with concrete-filled steel tubular (CFST) column elements was proposed. An energy dissipation shear wall specimen with CFST column elements (GZSW) and an ordinary reinforced concrete shear wall (SW) were constructed, and experimented by low-cycle reversed loading. The mechanical characteristics of these two specimens, including the bearing capacity, ductility, energy dissipation, and stiffness degradation process, were analyzed. The finite-element model of the GZSW was established by ABAQUS. Based on this finite-element model, the effect of the placement of steel-plate energy dissipation connectors on the seismic performance of the shear wall was analyzed, and optimization was performed. The experiment results prove that, the GZSW exhibited a superior seismic performance in terms of bearing capacity, ductility, energy dissipation, and stiffness degradation, in comparison with the SW. The results calculated by the ABAQUS finite-elements model of GZSW corresponded well with the results of experiment, and it proved the rationality of the established finite-elements model. In addition, the optimal placement of the steel-plate energy dissipation connectors was obtained by ABAQUS.

철근 콘크리트 벽과 강판 콘크리트 벽이 수직으로 만나는 이질접합 구조물의 면외 휨 거동 특성 연구 (A Study on Out-of-Plane Flexural Behavior of the Structure with a Vertical Plane Connection between a Reinforced Concrete Wall and a Steel Plate Concrete Wall)

  • 황경민;이경진;함경원;김원기
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.93-102
    • /
    • 2013
  • 본 연구에서는 철근콘크리트 벽과 강판 콘크리트 벽이 서로 수직면의 이질접합 형태로 만나는 벽의 면외 휨 거동 특성을 검토하기 위하여, L형 실험체를 제작하고 휨 실험을 수행하였다. 실험 시, 실험체의 동적특성을 확인하기 위하여 Push 및 Pull 하중을 반복하는 싸이클 하중을 구현하고자 하였다. Push 하중에 의한 실험 결과, 실험체의 공칭강도를 초과하는 휨 성능을 발휘하였으며, 이에 따라 설계에 적용된 수직철근의 미겹침 이음길이의 타당성을 확인할 수 있었다. 한편, Pull 하중 가력 시에는 수직철근이 최대 내력을 발휘하기 전에 접합부 콘크리트에서 전단 파괴 거동이 나타나, 이에 대한 보강이 필요함을 확인하였다.

개구부가 있는 강판콘크리트 벽체의 압축특성 분석 (Analysis of Compression Characteristics of the Steel Plate-Concrete Wall Structures with Openings)

  • 최병정
    • 한국강구조학회 논문집
    • /
    • 제24권3호
    • /
    • pp.245-256
    • /
    • 2012
  • 본 연구는 SC 벽체의 구조적 성능에 개구부가 주는 영향을 평가하는 목적으로 하였다. SC구조의 실험체는 개구부가 있는 실험체와 없는 실험체로 구분하였으며 개구부형상은 정사각형으로 개구부 주변의 보강과 비보강 그리고 슬리브두께를 변수로 계획하였다. 실험체의 공통된 파괴양상은 강판의 좌굴이 스터드와 스터드 사이에서 발생한 후 콘크리트의 균열이 진행되는 형태이며 개구부의 파괴형태는 수직 슬리브 벽이 개구부 안쪽으로 좌굴되는 파괴형태를 보여주었다. 또한 개구부의 슬리브 유무에 따라 강판좌굴 하중은 비슷하지만 최대압축강도는 슬리브가 있는 것이 크게 나타났다.