• Title/Summary/Keyword: a speed regulation mode

Search Result 35, Processing Time 0.034 seconds

Slip Power Recovery System by Switch Mode Converter (스위치모드 콘버어터에 의한 슬립전력 회수시스템)

  • Whang, Young-Moon;Choo, Young-Bae;Park, Han-Woong;Kim, Jung-Hong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.221-223
    • /
    • 1997
  • This paper deals with the slip power recovery system using switch mode converter in the inverter DC side, which recovers slip power of induction machine to AC line with the aid of the boost converter. As a results, the motor speed can be controlled by the duty ratio of boost switch, not by inverter firing angle. This results that the reactive power produced by phase controlled inverter and diode rectifier can be greatly reduced and linear speed regulation can be obtained. Moreover, the harmonic components of line current caused by the commutation in inverter and rectifier can be considerably suppressed. Therefore, most of the problems in conventional system can be solved.

  • PDF

Fuzzy sliding mode controllers for high performance control of AC servo motors (AC 서보 모터의 고성능 제어를 위한 퍼지 슬라이딩 모드 제어기)

  • 김광수;조동일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.732-735
    • /
    • 1997
  • Variable Structure Controller(VSC) is usually known to have robustness to bounded exogenous disturbances. The robustness is attributed to the discontinuous term in the control input. However, this discontinuous term also causes an undesirable effect called chattering. To alleviate chattering, a hybrid controller consisting of VSC and Fuzzy Logic Controller(FLC) is proposed, which belongs to the category of Fuzzy Sliding Mode Controller(FSMC). The role of FLC in FSMC is to replace a fixed gain of a discontinuous term with a time-varying one based on a specified rule base. The characteristics of proposed controller are shown to be similar to those of VSC with a saturation function instead of sign function. The only remarkable difference is the nonlinearity whose form can be adjusted by free parameters, normalize gain, denormalize gain, and membership functions. Applied to AC servo motor, the proposed controller is compared with VSC in a regulation problem as well as a speed tracking problem. The simulation results show a substantial chatter reduction.

  • PDF

The Speed and Position Sensorless Control of Switched Reluctance Motor using Binary Observer

  • Yang, Lee-Woo;Kim, Young-Cho;Choi, Jung-Soo;Kim, Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.736-741
    • /
    • 1998
  • It is well known that an encoder or a resolver is necessary to obtain the position data for speed or position control Generally utilized speed sensors are mal-affected by the EMI, dusty, and high temperature surroundings. Therefore, the speed and position sensorless controls using observers have been studied widely. In this paper, the binary observer which is composed of two feedback regulation loops to control the speed of SRM(Switched Reluctance Motor) is applied. One loop compensates the control input directly like the sliding mode control, and the other one compensates the system parameters indirectly. This observer is constructed on the foundation of variable structure control on the foundation of variable structure control theory and has the inertial term for the varying parameter. The validities of this proposed method is proved by experiments.

  • PDF

A New Slip Power Recovery System by Switch Mode Converter (스위치모드 컨버터에 의한 새로운 슬립전력 회수시스템)

  • 박한웅;박성준;김철우;황영문
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.73-81
    • /
    • 1999
  • A new slip power recovery system applying a switch mode converter to the rotor circuit of the wound rotor induction machine is proposed and investigated in this paper. With the analysis of the steady-state performances of the proposed system, it can be shown that the speed can be controlled by the duty ratio of the converter switch and the several characteristics of a conventional system can be also improved. In particular, the low power factor and the harmonic components in the line current, which are the main disadvantages of the conventional system, is significantly improved, and linear speed regulation can be obtained. Theoretical and experimental results are presented and illustrated to demonstrate the satisfactory working of the proposed system.

Analysis of Emission Gas Characteristics for Gasoline Vehicles using the Inspection Results of Car Emission (운행차 배출가스 정밀검사 결과를 이용한 가솔린 차량에 대한 배출가스 특성 분석)

  • Roh, Hyun Gu
    • Journal of ILASS-Korea
    • /
    • v.23 no.3
    • /
    • pp.128-135
    • /
    • 2018
  • In this study, the following conclusions could be obtained from the analysis of emissions contribution rates and features for contaminated emissions by 13,456 gasoline vehicles passed in the vehicle load test (ASM-idle) under the inspection year 2013 to 2017. It was confirmed that the contamination of the CO, HC, NOx by the displacement is reduced on over 3L engine. As a result of comparing the exhaust gas in the low speed idle mode and the AS2525 mode, the exhaust gas in the low speed idle mode was measured high. It is estimated that if ISG function is applied, emissions from idle condition will be reduced. NOx emissions were reduced when the engine power was above 200HP. It has been confirmed that the amount of exhaust emissions are significantly reduced for vehicles manufactured after 2004. As a result of analyzing the exhaust gas according to the season, it is judged that there is a correlation between HC and NOx according to the ambient temperature. The concentration of exhaust emission in vehicles with high accumulated distance increases, which is considered to be the result of aging of the vehicle.

Sensorless Fuzzy MPPT Control for a Small-scale Wind Power Generation System with a Switched-mode Rectifier (SMR 회로를 이용한 소형풍력발전 시스템의 센서리스 퍼지 MPPT제어)

  • Lee, Joon-Min;Park, Min-Gi;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.916-923
    • /
    • 2014
  • This paper proposes a low-cost switched-mode rectifier (SMR) for a small-scale wind turbine with a permanent magnet synchronous generator (PMSG) system. Also, a sensorless Fuzzy MPPT control is realized by the proposed system. In the PMSG system with the SMR, the synchronous impedance can be replaced as the input inductor of a boost converter. Moreover, the sensorless MPPT control using the Fuzzy technique is carried out by the duty-ratio regulation of the SMR. The relation between the generating power and the duty-ratio is ruled by the chain rule. The wind turbine model is implemented by the squirrel cage induction motor and generated the variable torque when the generator speed is varied. To verify the performance of the proposed system, simulation and experimental results are executed.

Effect Analysis for Frequency Recovery of 524 MW Energy Storage System for Frequency Regulation by Simulator

  • Lim, Geon-Pyo;Choi, Yo-Han;Park, Chan-Wook;Kim, Soo-Yeol;Chang, Byung-Hoon;Labios, Remund
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.227-232
    • /
    • 2016
  • To test the effectiveness of using an energy storage system for frequency regulation, the Energy New Business Laboratory at KEPCO Research Institute installed a 4 MW energy storage system (ESS) demonstration facility at the Jocheon Substation on Jeju Island. And after the successful completion of demonstration operations, a total of 52 MW ESS for frequency regulation was installed in Seo-Anseong (28 MW, governor-free control) and in Shin-Yongin (24 MW, automatic generation control). The control system used in these two sites was based on the control system developed for the 4 MW ESS demonstration facility. KEPCO recently finished the construction of 184 MW ESS for frequency regulation in 8 locations, (e.g. Shin-Gimjae substation, Shin-Gaeryong substation, etc.) and they are currently being tested for automatic operation. KEPCO plans to construct additional ESS facilities (up to a total of about 500 MW for frequency regulation by 2017), thus, various operational tests would first have to be conducted. The high-speed characteristic of ESS can negatively impact the power system in case the 500 MW ESS is not properly operated. At this stage we need to verify how effectively the 500 MW ESS can regulate frequency. In this paper, the effect of using ESS for frequency regulation on the power system of Korea was studied. Simulations were conducted to determine the effect of using a 524 MW ESS for frequency regulation. Models of the power grid and the ESS were developed to verify the performance of the operation system and its control system. When a high capacity power plant is tripped, a 24 MW ESS supplies power automatically and 4 units of 125MW ESS supply power manually. This study only focuses on transient state analysis. It was verified that 500 MW ESS can regulate system frequency faster and more effectively than conventional power plants. Also, it was verified that time-delayed high speed operations of multiple ESS facilities do not negatively impact power system operations. It is recommended that further testing be conducted for a fleet of multiple ESSs with different capacities distributed over multiple substations (e.g. 16, 24, 28, and 48 MW ESS distributed across 20 substations) because each ESS measures frequency individually. The operation of one ESS facility will differ from the other ESSs within the fleet, and may negatively impact the performance of the others. The following are also recommended: (a) studies wherein all ESSs should be operated in automatic mode; (b) studies on the improvement of individual ESS control; and (c) studies on the reapportionment of all ESS energies within the fleet.

A Parametric Study of Crash Scenario of Autonomous Vehicle and Database Construction (자율주행차 충돌시나리오 파라미터 분석과 차대차 충돌해석 DB 구성)

  • Young Myoung So;Ho Kim;Junsuk Bae
    • Journal of Auto-vehicle Safety Association
    • /
    • v.15 no.4
    • /
    • pp.39-47
    • /
    • 2023
  • Research on the safety of autonomous vehicle is being conducted in various countries, including the European Union, and computer simulation techniques so called 'Virtual Tool Chain' are mainly used. As part of the crash safety study of autonomous vehicle, 25 car to car collision scenarios were provided as a result of a real accident-based accident reproduction analysis study conducted by a domestic research institution, and a vehicle crash analysis was performed using the FE car to car model of the Honda Accord. In order to analyze the results of the car to car simulation and to construct a database, major crash parameters were selected as impact speed, angle, location, and overlap, and a method of defining them in an indexed form was presented. In order to compare the crash severity of each scenario, a value obtained by integrating the resultant acceleration measured by the ACU of the vehicle was applied. The equivalent collision test mode was derived by comparing the crash severity of the regulation test mode, 30 deg rigid barrier mode, in the same way.

Analysis of Doubly Fed Variable-Speed Pumped Storage Hydropower Plant for Fast Response (빠른 응답성을 갖는 가변속 DFIM 분석)

  • Sun, Jinlei;Seo, Joungjin;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.425-430
    • /
    • 2022
  • A pumped storage power station is an important means to solve the problem of peak load regulation and ensures the safety of power grid operation. The doubly fed variable-speed pumped storage (DFVSPS) system adopts a doubly fed induction machine (DFIM) to replace the synchronous machine used in traditional pumped storage. The stator of DFIM is connected to the power grid, and the three-phase excitation windings are symmetrically distributed on the rotor. Excitation current is supplied by the converter. The active and reactive power of the unit can be quickly adjusted by adjusting the amplitude, frequency, and phase of the rotor-side voltage or current through the converter. Compared with a conventional pumped storage hydropower station (C-PSH), DFVSPS power stations have various operating modes and frequent start-up and shutdown. This study introduces the structure and principle of the DFVSPS unit. Mathematical models of the unit, including a model of DFIM, a model of the pump-turbine, and a model of the converter and its control, are established. Fast power control strategies are proposed for the unit model. A 300 MW model of the DFVSPS unit is established in MATLAB/Simulink, and the response characteristics in generating mode are examined.

A Study on the Induced Voltages on Subscriber Telecommunication Lines from High-Speed Electrified Railway Line (고속전철에 의한 통신선로 전력유도 현상에 관한 고찰)

  • Oh, Ho-Seok;Kang, Seong-Yong;Yun, Ju-Yeong;Kim, Hak-Chul;Choi, Kyung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.10
    • /
    • pp.71-79
    • /
    • 2008
  • This paper analyzed the voltage induction phenomena on the telecommunication lines by electromagnetic coupling from high-speed A.C. electrified railway. The induced common mode voltages and the induced differential mode voltage on the telecommunication line was measured by notified standard method in the regulation of Korea. The test lines consist of 2 separated lines of 20 m and 300 m in influence distance each for comparison, with 2km inducing length. The analysis is made on the induced voltages from the different influence distances and the different earthing points, and also on the waveform and spectrum distributions. It is proved that the induction is arisen so good and the measured values are fair enough against noise such as the earth voltage differencing, and the current measuring scheme is also rightful.