• 제목/요약/키워드: a optic fiber

검색결과 888건 처리시간 0.027초

Polarization Insensitive Fiber-Optic Refractometer based on a Side-polished Fiber Coupler with a Thick Glass Waveguide

  • Sohn, Kyung-Rak;Song, Jae-Won;Kim, Hyung-Pyo
    • Journal of the Optical Society of Korea
    • /
    • 제6권3호
    • /
    • pp.117-120
    • /
    • 2002
  • Side-polished single-mode fiber covered with a thick planar-glass-waveguide is studied as a polarization-insensitive fiber-optic refractometer The properties of the device are very sensitive to the index variation of an upper cladding on top of the overlay waveguide. We investigate the spectral response, the polarization properties, and the relationship between the shift in coupling wavelength and the index variation of an upper cladding layer Index resolutions of the order of 10-4 have been achieved.

TLS와 CW 광원에 따른 트랜스포머 오일 내에서 광섬유 센서의 음압 감지 특성 연구 (Investigation of Sound Pressure Detection of Fiber Optic Sensor in Transformer Oil According to TLS and CW Laser Source)

  • 이종길
    • 한국음향학회지
    • /
    • 제30권1호
    • /
    • pp.33-41
    • /
    • 2011
  • 음압을 감지할 수 있는 Sagnac 간섭계 센서와 온도 및 스트레인을 측정할 수 있는 FBG센서를 결합한 새로운 형태의 하이브리드 광섬유 센서 시스템을 구축하기 위하여 입력 광원인 CW를 TLS로 대체할 필요가 있어 이에 따라 광원의 변화와 맨드릴 재료의 변화에 따른 광섬유 센서의 응답 특성 연구가 필요하게 되었다. 제작된 맨드릴 재료는 PTFE와 PTFE에 카본을 섞어 만든 두 종류로 선택하여 중공 원통형 맨드릴 겉면에 광섬유를 18 m 감아 광섬유 센서로 제작하였다. CW 광원에 대하여 음원의 입력 주파수를 1 kHz~20 kHz까지 바꾸어 가며 트랜스포머 오일이 채워진 유조에서 실험하였다. 또한 FBG와 맨드릴형 광섬유 센서를 결합한 하이브리드형 광섬유 센서 시스템을 구성하고 TLS 광원을 입사광으로 실험하였다. 실험 결과 PTFE 센서의 탐지 크기는 카본 센서 탐지 크기보다 높게 나타났고 맨드릴 재질의 탄성계수 값이 적을수록 커진다는 이론 결과와 잘 일치함을 보였다. CW 광원과 TLS 광원에서 응답한 PTFE 센서의 특성을 주파수별로 상호 비교하여 보면 광원이 CW일 때 보다 TLS일 때 응답 특성이 우수함을 알 수 있었다. 본 연구를 통하여 TLS를 이용한 광섬유 센서는 FBG와의 하이브리드 시스템에 적용 가능하리라 사료된다.

Experimental investigations on detecting lateral buckling for subsea pipelines with distributed fiber optic sensors

  • Feng, Xin;Wu, Wenjing;Li, Xingyu;Zhang, Xiaowei;Zhou, Jing
    • Smart Structures and Systems
    • /
    • 제15권2호
    • /
    • pp.245-258
    • /
    • 2015
  • A methodology based on distributed fiber optic sensors is proposed to detect the lateral buckling for subsea pipelines in this study. Uncontrolled buckling may lead to serious consequences for the structural integrity of a pipeline. A simple solution to this problem is to control the formation of lateral buckles among the pipeline. This firms the importance of monitoring the occurrence and evolution of pipeline buckling during the installation stage and long-term service cycle. This study reports the experimental investigations on a method for distributed detection of lateral buckling in subsea pipelines with Brillouin fiber optic sensor. The sensing scheme possesses the capability for monitoring the pipeline over the entire structure. The longitudinal strains are monitored by mounting the Brillouin optical time domain analysis (BOTDA) distributed sensors on the outer surface of the pipeline. Then the bending-induced strain is extracted to detect the occurrence and evolution of lateral buckling. Feasibility of the method was validated by using an experimental program on a small scale model pipe. The results demonstrate that the proposed approach is able to detect, in a distributed manner, the onset and progress of lateral buckling in pipelines. The methodology developed in this study provides a promising tool for assessing the structural integrity of subsea pipelines.

광 케이블 풀림 거동의 실험적 검증 및 고속 풀림 거동 예측 (Experimental Verification of Unwinding Behavior of Fiber-Optic Cable and Prediction of High-Speed Unwinding)

  • 김건우;이재욱;김형렬;유완석
    • 대한기계학회논문집A
    • /
    • 제38권3호
    • /
    • pp.243-250
    • /
    • 2014
  • 유도체의 발사로 인해 스풀로부터 풀리는 광 케이블은 모함과의 통신을 통해 작전 수행 능력을 향상시키는 역할을 한다. 일반적으로 광 케이블의 풀림은 거동의 안정성 확보 및 풀림 불량 방지를 위하여 수중에서 진행된다. 따라서 본 연구에서는 실험을 통해 스풀로부터 풀리는 광 케이블의 거동특성을 확보하고 이를 풀림 거동 해석 결과와 비교함으로써 해석의 신뢰성을 검증한다. 실험 장치의 구성은 수조와 감김 장치로 구성되며, 고속카메라를 통해 케이블의 풀림 거동을 촬영하였다. 해석결과를 제시하기 위한 과도 상태 운동 방정식은 직교 좌표계를 사용하여 정의한 뒤, 실험 결과와의 비교를 통해 해석 결과의 타당성을 검증하였으며, 풀림 속도의 증가에 따른 풀림 거동을 예측하였다.

뉴트럴레드가 고정화된 다공성 졸-겔 필름을 이용한 고감도 광섬유 pH 센서의 특성 (High-Sensitive Fiber-Optic pH Sensor Using Neutral Red Immobilized in Porous Sol-Gel Film)

  • 전다영;유욱재;신상훈;한기택;박장연;박병기;조승현;이봉수
    • 센서학회지
    • /
    • 제21권3호
    • /
    • pp.223-228
    • /
    • 2012
  • In this study, a fiber-optic pH sensor based on a pH sol-gel film is fabricated. The sol-gel film is made by co-polymerizing tetramethoxysilane, trimethoxymethylsilane, ethanol and distilled water. As a pH indicator, a neutral red is immobilized in a thin porous film formed by the sol-gel process. The pH change in a sensing probe gives rise to a change in the color of the pH sol-gel film, and the absorbance of reflected light through the pH sol-gel film is also changed. By using a spectrometer, therefore, the spectra of reflected lights in the sensing probe with different pH values are measured. Also, the relationships between the pH values and the absorbance are analyzed on the basis of the color variations of the pH sol-gel films. In repeated experiments, the fiber-optic pH sensor shows that it has reversibility, a high reproducibility and a wide absorbance change in a pH range from pH 5 to 9. Also, we confirmed that the fabricated pH sol-gel film exhibits a fast response time, little or no pH indicator leaching and a dynamic range of 2.04 dB from pH 5 to 9. Based on the results of this study, a fiber-optic pH sensor can be developed for the pH monitoring in the harsh environments.

퍼지 PI제어를 이용한 광섬유형 ESPI의 위상 안정화 (Phase stabilization of fiber optic ESPI using Fuzzy PI controller)

  • 박형준;송민호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.530-534
    • /
    • 2004
  • We propose a phase stabilisation and control system for the use in fiber-optic ESPI. The fast phase stabilisation against environmental perturbations has been achieved by using Fuzzy PI control. Combined with closed-loop switching, the system showed accurate and fast ${\pi}/2$ phase stepping capability.

  • PDF

광섬유센서를 이용한 고속주행 트럭의 축중 측정에 관한 연구 (Study on the High Speed WIM(Weigh-in-Motion) Measurement with Optical Fiber Sensor System)

  • 조성규;김기수;배병우
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.451-460
    • /
    • 2003
  • In this paper, high speed fiber optic sensor weigh-in motion (WIM) system is proposed. Bragg gratings which have several advantages such as good reproducibility and good multiplicity compare to other optical fiber sensors are used for the system. Fabry-Perot filter for the signal process, which cannot be used in the high speed measurement because of the limitation in fast operation of PZT, is excluded. A new signal processing system which employs bandwidth filter is proposed and bridge type new sensor package design is also proposed. Design of the mold supporter is modified to round shape and then supporting points do not change. The data from the fiber sensors show identical and linear behavior to the axle weight. The proposed fiber optic WIM system is tested in the laboratory and experimented with actual trucks. The new concept of calibration is introduced and calculated by the experiments. The calibrated weight data show good approximations to real axial weights regardless the velocities of the truck.

  • PDF

후두 내시경(Fiber-Optic Nasolaryngoscope)을 이용한 말더듬인의 후두양상에 관한 연구 (A Study on Laryngeal Behavior of Persons Who Stutter with Fiber-Optic Nasolaryngoscope)

  • 정훈;안종복;최병흔;권도하
    • 음성과학
    • /
    • 제15권3호
    • /
    • pp.159-173
    • /
    • 2008
  • The purpose of this study was to use fiber-optic nasolaryngoscope to find out differences in laryngeal behavior between persons who stutter(PS) and those who do not stutter(NS) upon their utterance. To meet the goal above, this study took 5 NS and 5 PS respectively as a part of sampling, so that they were all asked to join an experiment hereof. As a result, this study came to the following findings: First, there was not any significant difference in laryngeal behavior of uttering spoken languages between stuttering group and control. Second, there were some differences in laryngeal behavior of repetition and prolongation, which were a sort of disfluency revealed in the utterance of nonfluent spoken languages between stuttering group and control. Third, as reported by prior studies, it was found that there were differences in laryngeal abehavior of stutterer group's nonfluent spoken languages depending upon stuttering types. In this study, a variety of laryngeal behavior unreported in prior studies could be found. In addition, it was notable that stutterers showed different laryngeal behavior depending on their personal stuttering types. On block condition, Subject 1 showed laryngeal behavior of fAB, INT and fAD; Subject 2 showed laryngeal behavior of fAB, fAD and rAD; Subject 3 showed laryngeal behavior of fAD and rAD; Subject 4 showed only laryngeal behavior of fAD; and Subejct 5 showed laryngeal behavior of fAB, fAD and rAD. Summing up, these findings imply that when stutterers utter nonfluent words, they may reveal a variety of laryngeal behavior depending on their personal stuttering types. Moreover, it is found that there are more or less differences in the utterance of nonfluent spoken languages between NS and stuttering ones. In particular, it is interesting that one common trait of nonfluent spoken languages uttered by PS is evidently excessive laryngeal stress, no matter which type of stuttering they reveal.

  • PDF

Cyclic olefin copolymer (COC) 폴리머 프리즘을 사용한 광섬유 기반 표면 플라즈몬 공명 (SPR) 바이오 센서 (A fiber optic surface plasmon resonance (SPR) sensorusing cyclic olefin copolymer (COC) polymer prism)

  • 윤성식;이수현;안종혁;이종현
    • 센서학회지
    • /
    • 제17권5호
    • /
    • pp.369-374
    • /
    • 2008
  • A novel fiber optic surface plasmon resonance (SPR) sensor using cyclic olefin copolymer (COC) prism with the spectral modulation is presented. The SPR sensor chip is fabricated using the SU-8 photolithography, Ni-electroplating and COC injection molding process. The sidewall of the COC prism is partially deposited with Au/Cr (45/2.nm thickness) by e-beam evaporator, and the thermal bonding process is conducted for micro fluidic channels and optical fibers alignment. The SPR spectrum for a phosphate buffered saline (0.1.M PBS, pH.7.2) solution shows a distinctive dip at 1300.nm wavelength, which shifts toward longer wavelength with respect to the bovine serum albumin (BSA)concentrations. The sensitivity of the wavelength shift is $1.16\;nm{\cdot}{\mu}g^{-1}{\cdot}{\mu}l^{-1}$. From the wavelength of SPR dips, the refractive indices (RI) of the BSA solutions can be theoretically calculated using Kretchmann configuration, and the change rate of the RI was found to be $2.3{\times}10^{-5}RI{\cdot}{\mu}g^{-1}{\cdot}l^{-1}$. The realized fiber optic SPR sensor with a COC prism has clearly shown the feasibility of a new disposable, low cost and miniaturized SPR biosensor for biochemical molecular analyses.

NOVEL FIBER OPTIC COLOR SYNTHESIZER FOR PICO-PROJECTION DISPLAY WITH AN ULTRA WIDE COLOR GAMUT

  • Oh, Kung-Hwan;Lee, Sei-Jin;Ha, Woo-Sung;Park, Min-Kyu;Kim, Jun-Ki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1327-1330
    • /
    • 2008
  • A novel fiber optic solution is provided to efficiently mix visible colors. Full color synthesis was achieved utilizing a novel $3{\times}1$ hard polymer clad fiber (HPCF) coupler along with red, green and blue (RGB) light emitting diode (LED) primaries. Varying the intensities of RGB LEDs that are coupled to three input ports, the device rendered a full color with an ultra wide CIE color gamut. Potential applications in pica-projection displays and LED backlights will be discussed.

  • PDF