• Title/Summary/Keyword: a monitoring

Search Result 21,802, Processing Time 0.047 seconds

Application of compressive sensing and variance considered machine to condition monitoring

  • Lee, Myung Jun;Jun, Jun Young;Park, Gyuhae;Kang, To;Han, Soon Woo
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.231-237
    • /
    • 2018
  • A significant data problem is encountered with condition monitoring because the sensors need to measure vibration data at a continuous and sometimes high sampling rate. In this study, compressive sensing approaches for condition monitoring are proposed to demonstrate their efficiency in handling a large amount of data and to improve the damage detection capability of the current condition monitoring process. Compressive sensing is a novel sensing/sampling paradigm that takes much fewer data than traditional data sampling methods. This sensing paradigm is applied to condition monitoring with an improved machine learning algorithm in this study. For the experiments, a built-in rotating system was used, and all data were compressively sampled to obtain compressed data. The optimal signal features were then selected without the signal reconstruction process. For damage classification, we used the Variance Considered Machine, utilizing only the compressed data. The experimental results show that the proposed compressive sensing method could effectively improve the data processing speed and the accuracy of condition monitoring of rotating systems.

System identification of a building structure using wireless MEMS and PZT sensors

  • Kim, Hongjin;Kim, Whajung;Kim, Boung-Yong;Hwang, Jae-Seung
    • Structural Engineering and Mechanics
    • /
    • v.30 no.2
    • /
    • pp.191-209
    • /
    • 2008
  • A structural monitoring system based on cheap and wireless monitoring system is investigated in this paper. Due to low-cost and low power consumption, micro-electro-mechanical system (MEMS) is suitable for wireless monitoring and the use of MEMS and wireless communication can reduce system cost and simplify the installation for structural health monitoring. For system identification using wireless MEMS, a finite element (FE) model updating method through correlation with the initial analytical model of the structure to the measured one is used. The system identification using wireless MEMS is evaluated experimentally using a three storey frame model. Identification results are compared to ones using data measured from traditional accelerometers and results indicate that the system identification using wireless MEMS estimates system parameters with reasonable accuracy. Another smart sensor considered in this paper for structural health monitoring is Lead Zirconate Titanate (PZT) which is a type of piezoelectric material. PZT patches have been applied for the health monitoring of structures owing to their simultaneous sensing/actuating capability. In this paper, the system identification for building structures by using PZT patches functioning as sensor only is presented. The FE model updating method is applied with the experimental data obtained using PZT patches, and the results are compared to ones obtained using wireless MEMS system. Results indicate that sensing by PZT patches yields reliable system identification results even though limited information is available.

A Design of New Real Time Monitoring Embedded Controller using Boundary Scan Architecture (경계 주사 구조를 이용한 새로운 실시간 모니터링 실장 제어기 설계)

  • 박세현
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.6
    • /
    • pp.570-578
    • /
    • 2001
  • Boundary scan architecture test methodology was introduced to facilitate the testing of complex printed circuit board. The boundary scan architecture has a tremendous potential for real time monitoring of the operational status of a system without interference of normal system operation. In this paper, a new type of embedded controller for real time monitoring of the operational status of a system is proposed and designed by using boundary scan architecture. The proposed real time monitoring embedded controller consists of test access port controller and an embedded controller proposed real time monitoring embedded controller using boundary scan architecture can save the hard-wire resource and can easily interface with boundary scan architecture chip. Experimental results show that the real time monitoring using proposed embedded controller is more effective then the real time monitoring using host computer.

  • PDF

A New Approach to On-Line Monitoring Device for ZnO Surge Arresters

  • Lee Bok-Hee;Gil Hyoung-Jun;Kang Sung-Man
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.131-137
    • /
    • 2005
  • This paper describes a new approach to the algorithm and fundamental characteristics of the device for monitoring the leakage currents flowing through zinc oxide (ZnO) surge arresters. In order to obtain a technique for a new on-line monitoring device that can be used in the deterioration diagnosis of ZnO surge arresters, the new algorithm and on-line leakage current detection device for extracting the resistive and capacitive currents using the phase shift addition method were proposed. The computer-based on-line monitoring device can sense accurately the power frequency leakage currents flowing through ZnO surge arresters. The on-line leakage current monitoring device of ZnO surge arresters proposed in this work has the high sensitivity compared to the third harmonic leakage current detection devices. As a consequence, it was found that the proposed leakage current monitoring device would be useful for forecasting the defects and degradation of ZnO surge arresters.

Wireless safety monitoring of a water pipeline construction site using LoRa communication

  • Lee, Sahyeon;Gil, Sang-Kyun;Cho, Soojin;Shin, Sung Woo;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.433-446
    • /
    • 2022
  • Despite efforts to reduce unexpected accidents at confined construction sites, choking accidents continue to occur. Because of the poorly ventilated atmosphere, particularly in long, confined underground spaces, workers are subject to dangerous working conditions despite the use of artificial ventilation. Moreover, the traditional monitoring methods of using portable gas detectors place safety inspectors in direct contact with hazardous conditions. In this study, a long-range (LoRa)-based wireless safety monitoring system that features the network organization, fault-tolerant, power management, and a graphical user interface (GUI) was developed for underground construction sites. The LoRa wireless data communication system was adopted to detect hazardous gases and oxygen deficiency within a confined underground space with adjustable communication range and low power consumption. Fault tolerance based on the mapping information of the entire wireless sensor network was particularly implemented to ensure the reliable operation of the monitoring system. Moreover, a sleep mode was implemented for the efficient power management. The GUI was also developed to control the entire safety-monitoring system and to manage the measured data. The developed safety-monitoring system was validated in an indoor testing and at two full-scale water pipeline construction sites.

Generating Tool for Visualization System in Real-time Field Monitoring (실시간 현장 감시를 위한 가시화 시스템 생성 도구)

  • Park, Bokuk;Tak, Haesung;Lee, Chae-Ho;Cho, Hwan-Gue
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.54-63
    • /
    • 2014
  • It is general that the field plant is too large to be monitored by human works. So it is crucial to prepare one automated monitoring system to prevent unexpected accidents in advance. However, most of previous monitoring systems were to be implemented by human programmer independently, so the total developing cost of a set of similar monitoring systems is so high. In order to overcome this disadvantage, we propose a new specification language for meta-description of monitoring system. Also we propose a generation tool for monitoring system with the input meta-description files. Using these meta-description files, we show it is so fast and effective to get a new monitoring system for a specific field plant. In experiment we have shown that our generation system work successfully in newly developing a monitoring system for the water-vessel plant.

Development of Long-Term Storage Technology for Chinese Cabbage - Physiological Characteristics of Postharvest Freshness in a Cooler with a Monitoring and Control Interface

  • Lim, Ki Taek;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.194-204
    • /
    • 2014
  • Purpose: The aim of this study was to develop long-term storage technology for Chinese cabbage in order to extend the period of availability of freshly harvested products. The scope of the paper deals with the use of a cooler with a remote monitoring and control interface in conjunction with use of packaging film. Methods: A cooler with a real time monitoring system was designed as a low-temperature storage facility to control temperature and relative humidity (RH). The effects of storage in high-density polyethylene (HDPE) plastic boxes, 3% chitosan dipping solution, polypropylene film (PEF) with perforations, and mesh packaging bags on physiological responses were investigated. The optimal storage temperature and humidity for 120 days were below $0.5^{\circ}C$ and 90%, respectively. Physiological and biochemical features of cabbage quality were also analyzed: weight loss, texture, and sugar salinity, chlorophyll, reducing sugar, and vitamin C contents. Results: The cooler with a remote monitoring and control interface could be operated by an HMI program. A $0.5^{\circ}C$ temperature and 90% humidity could be remotely controlled within the cooler for 120 days. Postharvest freshness of Chinese cabbages could be maintained up to 120 days depending on the packaging method and operation of the remote monitoring system. In particular, wrapping the cabbages in PEF with perforations resulted in a less than a 5% deterioration in quality. This study provides evidence for efficient performance of plastic films in minimizing post-harvest deterioration and maintaining overall quality of cabbages stored under precise low-temperature conditions with remote monitoring and a control interface. Conclusions: Packaging with a modified plastic film and storage in a precisely controlled cooler with a remote monitoring and control interface could slow down the physiological factors that cause adverse quality changes and thereby increase the shelf life of Chinese cabbage.

Low-power Environmental Monitoring System for ZigBee Wireless Sensor Network

  • Alhmiedat, Tareq
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.10
    • /
    • pp.4781-4803
    • /
    • 2017
  • Environmental monitoring systems using Wireless Sensor Networks (WSNs) face the challenge of high power consumption, due to the high levels of multi-hop data communication involved. In order to overcome the issue of fast energy depletion, a proof-of-concept implementation proves that adopting a clustering algorithm in environmental monitoring applications will significantly reduce the total power consumption for environment sensor nodes. In this paper, an energy-efficient WSN-based environmental monitoring system is proposed and implemented, using eight sensor nodes deployed over an area of $1km^2$, which took place in the city of Tabuk in Saudi Arabia. The effectiveness of the proposed environmental monitoring system has been demonstrated through adopting a number of real experimental studies.

Development of a Remote Central Monitoring System of Street Lights (가로등 원격감시 중앙관제시스템 개발)

  • Ha, Kwan-Yong;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.43-45
    • /
    • 2004
  • A remote monitoring system was developed to improve inconveniences of manual work such as monitoring street lights by using current sensors, microprocessor and RF communication system. In order to control the street lights on the roads effectively and monitor them in real time, we can attach current sensor to the street lights which monitors Lamp, the broken part and state of the Balast, and the amount of an electric leak precisely we developed a system which makes it possible to transmit the data on monitoring results in breakdown of street lights and Balasts to the central monitoring computer without setting up extra data transmission line. The system we devised can transmit data through Power Line Modem and RF communication using relay method to the central controlling computer without any loss of data.

  • PDF

Effects of Self-monitoring on Initiating Speech Behavior of the Hearing-impaired Preschoolers (자기점검법이 청각장애 유아의 자발적인 말시작 행동에 미치는 영향)

  • Hyun, No-Sang;Kim, Young-Tae
    • Speech Sciences
    • /
    • v.9 no.3
    • /
    • pp.99-112
    • /
    • 2002
  • The purpose of the present study was to investigate the effectiveness of self-monitoring on spontaneously initiating speech behavior of the hearing-impaired preschoolers. Three hearing-impaired preschoolers were selected from a special school for the deaf. They showed some vocalizations and words under intensive instruction settings, but never spontaneously spoke as a means of communication. Multiple probe design was applied in this study. During the self-monitoring intervention, each child was trained to assess whether his own initiating speech behavior was occurred or not, and then record his own behavior's occurrence on the self-recording sheets and self-graphing sheets. The vibration of handphone was used as a tactile cue for self-monitoring. The results of the present study were as follows: (1) self-monitoring significantly increased the percentage of occurrence of spontaneously initiating speech behaviors. (2) Increased level of spontaneously initiating speech behavior were generalized into another natural instruction (cognitive) settings. (3) Increased level of spontaneously initiating speech behavior were maintained after four weeks from the termination of the intervention.

  • PDF