• Title/Summary/Keyword: a lower temperature

Search Result 7,506, Processing Time 0.038 seconds

A Quantitative Study on the Effect of Temperature Control by a Shade Tree and the Lawn Area (식물의 온도 완화효과에 관한 기초적 연구)

  • 안계복;김기선
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.14 no.1
    • /
    • pp.1-13
    • /
    • 1986
  • The purpose of this study is to investigate the effect of temperature control by a shade tree and the lawn area. In this investigation, we find out that artificial-lawn, concerte, and exposed soil are more higher temperature than covered with plant materials. The results of the measurement may to summerized as follows; 1) Low-temperature effects of zoysia japonica is more controlled by condition of growth than leaf length of grass. Surface temperature make 0.7$^{\circ}C$ difference between long grass (15cm), and short grass (5cm), but make 5$^{\circ}C$ difference between good growth grass (230/10$\textrm{cm}^2$) and bad growth grass (80/10$\textrm{cm}^2$). 2) The surface temperature of the lawn area is 40.5$^{\circ}C$ lower on a maxinum than that of the artificial lawn (July 28, 1985). During the day of summer, shade area under the shade tree is 0.9$^{\circ}C$ lower then lawn area surface temperature, 6.9$^{\circ}C$ lower than bad growth lawn, 10.3$^{\circ}C$ lower than exposed soil, and 18$^{\circ}C$ lower than concrete surface temperature. 3) Natural irrigation effect on the surface temperature fluctuation. But this effect is changed by compositions of ground materials and time-lapse. 4) Sunny day is more effective than cloud day. 5) In summer season, surface temperature make a difference compare to temperature of 0.5-1.5m height from ground : Surface temperature is 3.4$^{\circ}C$ lower at the lawn area (11 a.m.), 4.2$^{\circ}C$ lower at the shade area the shade tree, 12.7$^{\circ}C$ higher at the concrete area (3p.m.), 38.8$^{\circ}C$ higher at the artificial lawn (2p.m.) 6) According to compositions of ground materials and season have specific vertical temperature distribution curve. 7) In summer season, temperature distribution of 0.5-1.5m hight at the shade tree is 4.8-5.7$^{\circ}C$ lower than concrete area (noon-3p.m.)

  • PDF

Air Temperature Variation by Effect of Green Space Condition (녹지 조건에 따른 기온변화)

  • Yoon, Yong-Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • In this study, we observed air temperature to make clear that land coverage condition and stand form has a certain relationship to air temperature during the night in various green space. And with revolution analysis, we interpreted relationship of air temperature distribution in the green space, The way of analysis is this land coverage rate and air temperature, of number of tree volume of tree air temperature. With this experimental result, we can propose green plan, which is taking into consideration lower effect of air temperature. In this result, lower zone is formed in forest and water area, higher zone is formed in paved surface and barren ground. but this gap is a little. arbor+subarbor area, in the point of water area surrounded stand is formed relative lower air temperature. As a result to make up efficiency lower air temperature area, it is needed to make water area which has surrounded forest, and it is needed to make stand form lower air temperature 2~3 layer forest. In order of arbor, subarbor, shrub, the lower air temperature is more effect.

Temperature Lowering Effects Varied by the Arrangement and Types of Vegetation (녹지의 배치와 식재형태가 열환경저감효과에 미치는 영향)

  • 윤용한
    • Asian Journal of Turfgrass Science
    • /
    • v.17 no.4
    • /
    • pp.165-172
    • /
    • 2003
  • Temperature lowering effects varied by the arrangement and types of vegetation The effects of the arrangement and types of vegetation on lowering temperature have shown following results. 1) The temperature range of a vegetation shows that a higher temperature was recorded near urban towns while lower temperature was observed around the vegetation area and small streams. 2) The relationship between the arrangement of a vegetation and the temperature indicates that the lower temperature area matches with each vegetation area. Streets between vegetations and the lower end of the wind area have also lower temperature. 3) The relationship between inter-vegetationstreets and the temperature indicates that the lower temperature area has been observed not only at the streets of the lower end of the wind but at the streets in-between streets as well. Even when there's no vegetation area from which the wind blows, inter-vegetation streets showed the lower temperature. 4) With land coverage ratio and the temperature, the increase of planted areas, grass areas, and water level have positive effects on lowering the temperature while bare areas increase it. 5) From arbor to sub-arbor, the increase of trees has a significant effect on lowering the temperature of nearby area.

Comparative Study of Maximum Temperature Condition in Green Space (녹지 조건에 따른 최고기온의 비교연구)

  • 윤용한
    • Asian Journal of Turfgrass Science
    • /
    • v.15 no.4
    • /
    • pp.181-186
    • /
    • 2001
  • In this study, we observed air temperature to make clear that land coverage condition and forest form has a certain relationship to air temperature in a day in various green space. And with revolution analysis, interpreted relationship of air temperature distribution in the green space, of land coverage rate and air temperature, of volume of tree and temperature. With this experimental result, propose green plan, taking into consideration lower effect of air temperature. In this result lower zone is formed in forest and water area, higher zone is done in paved surface and barren ground. And arbor+subarbor area, water area sur-rounded forest and small river is formed relative lower air temperature. In my opinion to promote efficiency lower air temperature area, it is need to make water area surrounded forest, to make forest form lower air temperature 2∼3 layer forest. Lower air temperature effect is in order of arbor, subarbor, shrub and is proportioned increasing of tree.

  • PDF

Effect of Thermal Discharge from Semiconductor Factory into Stream on Freshwater Fish

  • Je-Bin Yu;Sun-Jib Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.2
    • /
    • pp.375-380
    • /
    • 2023
  • The study was conducted in Manu-stream, located in Paju, Gyeonggi-do, from January 2021 to December 2021. The survey points were selected in the upper and lower streams based on where thermal discharged to investigate water temperature and fish species and biological community analysis and growth rate were analyzed. The average annual water temperature difference between the upper and lower stream is about 11.0℃, and in the case of the lower stream area, the water temperature is maintained at 20.0℃ or more per year. Fish that appeared during the survey period decreased lower stream compared to the upper stream, which is believed to be the result of a decrease in temperature-sensitive species as the simple riverbed structure and water temperature increased compared to the upper stream. As a result of biological community analysis, it showed a relatively stable community state at the upper stream. The growth rate of fish has a high regression coefficient b value in lower streams throughout the four seasons. It showed relatively good growth lower stream, with a high water temperature. However, the results of each survey point are similar from season to season. The indicator species is a resistant intermediate species, and the range of resistance to water temperature is wide, so it is judged that water temperature's effect on the indicator species' growth is low.

Selection of Diffuser for Lower Temperature Air Distribution System (저온공조용 취출구의 선정)

  • Park, Sung-Kyu;Yoo, Ho-Joon;Choi, Myeong-Shin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.484-492
    • /
    • 2008
  • Air Discharge pattern and even temperature distribution is critical for a successful lower temperature air distribution system, which would supply lower temperature air than normal HAVC system. Selection of appropriate diffuser is the most critical element in completing lower temperature system.

  • PDF

Effects of Covering Parts of Body with Garments on Human Thermoregulation and Sensation (신체의 부위별 피복이 체온조절 및 주곤적인 감각에 미치는 영향(I))

  • 이종민;이순원
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.2
    • /
    • pp.273-282
    • /
    • 1994
  • The physiological significances of the upper and lower body on thermoregulation and sensation were studied in this paper. Experiments were carried out on 4 females in a climatic chamber conditioned at 1) $25^{\circ}C\rightarrow35^{\circ}C\rightarrow25^{\circ}C$, 2) $25^{\circ}C\rightarrow15^{\circ}C\rightarrow25^{\circ}C$, both with 50% R.H., covering the upper body (U) or lower body (L) with garments. 1. When the upper or lower body is covered or exposured respectively, the mean skin tempterature of upper body is higher than that of lower body. And upper body is more easily influenced by the environmental temperature than lower body. It means the skin temperatures of the upper body change faster than those of the lower body following the environmental changes. 2. In U and L, the skin temperatures of the upper limbs (thighs, upper arms) are lower than those of the peripherals (hands, feet). 3. Warm sensations and skin temperatures of the upper body showed high correlation and it was the case with cold sensations and skin temperatures of the lower body. 4. In high temperature condition $(25^{\circ}C\rightarrow35^{\circ}C\rightarrow25^{\circ}C)$, mean skill temperature and rectal temperature in L were lower than in U. This lower rectal temperature in L is probably due to the insulation of the lower body with garments that promotes the heat radiation only in the high temperature environment.

  • PDF

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

  • Hyeongi Moon ;Sujong Yoon;Mauricio Tano-Retamale ;Aaron Epiney ;Minseop Song;Jae-Ho Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3874-3897
    • /
    • 2023
  • A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High-Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next-generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds-averaged Navier-Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

Prediction of Temperature Dependence of Lower Explosive Limits for Paraffinic Hydrocarbons (파라핀족탄화수소의 폭발하한계의 온도의존성 예측)

  • 하동명
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.71-77
    • /
    • 2000
  • The aim of this study is to investigate the temperature dependence of the lower explosive limit(LEL) at elevated temperature. The temperature dependence of the lower explosive limit is one of the significant indices of flammability and combustibility. By using the literature data, the new equations for predicting the temperature dependence of the lower explosive limits for paraffinic hydrocarbons are proposed. The values calculated by the proposed equations were a good agreement with the literature data. It is hoped eventually that this proposed equations will support the use of the prediction for the lower explosive limit and the flash points of the flammable mixtures.

  • PDF

Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 1 : Verification Experiment) (열교환코일 내장형 태양열 축열조의 성능향상 (제1보 실증실험))

  • Lee, Uk-Jae;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.213-219
    • /
    • 2015
  • A thermal storage tank with internal heat exchange coils is commonly used in solar thermal systems with a collector area below $100m^2$. The coils are installed in the lower part of the tank because the temperature of the upper part of the tank can drop if the outlet temperature of the collector becomes lower than the upper temperature of the tank, which is a kind of temperature reversal. As an alternative to the well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and have achieved superior thermal stratification in the tank, which results in increased collector efficiency and solar fraction. But, the phenomenon of temperature reversal was often observed in the tank when the load or solar radiation changed rapidly. In the present work, revised control was successfully applied, i.e., to heat only the lower coil using a three way valve if temperature reversal occurs and to operate the collector at a low flow rate when the quality of solar radiation is not good.