• 제목/요약/키워드: a fiber sensor

검색결과 1,030건 처리시간 0.023초

광CT 센서코일 끝단의 반사율이 전류측정에 미치는 영향 (Effects of reflective index of fiber sensor coil end on current measurement)

  • 박형준;김현진;송민호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.74-77
    • /
    • 2008
  • We improved an efficiency of fiber-optic current transformer by using a metal-coated sensor coil. To reduce the linear birefringence, we used a length of spun fiber as sensor coil, and then used a flint glass fiber coil for comparison. To make the sensor coil in the reflection type, we used different reflection mirrors at the end of the sensor coil, such as a Faraday rotator mirror, a simple mirror, a metal-coated fiber end and a simple fiber end. From the experimental results, the linear error of current measurements were less than ${\sim}$ 0.2 % regardless of the mirror types. The metal-coated sensor was the most cost-effective considering the fabrication cost and the simple structure.

  • PDF

광섬유 브래그 격자를 이용한 촉각 센서용 유연 단축 힘 센서의 개발 및 평가 (Development of Flexible Force Sensor Using Fiber Bragg Grating for Tactile Sensor and Its Evaluation)

  • 허진석;이정주
    • 한국정밀공학회지
    • /
    • 제23권2호
    • /
    • pp.51-56
    • /
    • 2006
  • This paper shows the development of flexible force sensor using the fiber Bragg grating. This force sensor consists of a Bragg grating fiber and flexible silicone rubber (DC184, Dow corning co. Ltd). This sensor does not have special structure to maximize the deflection or elongation, but have good sensitivity and very flexible characteristics. In addition, this sensor has the immunity to the electro magnetic field and can be multiplexed easily, which is inherited from the characteristics of fiber Bragg grating sensor. In the future, this sensor can be utilized the tactile sensor system minimizing the sensor size and developing the fabrication method.

Remote Monitoring of Abrupt Overflowing in Common Utility Duct Using Reflective Side-Polished Optical Fiber Submersion Sensor

  • Lee, Cherl-Hee;Kim, Cheol;Kang, Shin-Won;Song, Jae-Won
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.166-169
    • /
    • 2008
  • The submersion monitoring system based on a reflective side-polished optical fiber submersion sensor with an optical fiber mirror was shown to be an effective alarm system with remote monitoringwhen the drainage capacity of a common utility duct is exceeded due to heavy rainfall. The proposed sensor was connected to an existing installed optical fiber network at a height of 250mm in a common utility duct, and then tested under sample materials(distilled water, river water, sea water, foul water, muddy water, petroleum, edible oil) at a distance of 1km from the sensor for remote sensing. In experiments, the proposed real-time sensor system reduced maintenance cost and improved monitoring efficiency by using a reflection-type side-polished optical fiber submersion sensor efficient for remote monitoring of a common utility duct.

분포형 광섬유 센서망을 이용한 외부 음향 주파수 탐지 (Detection of External Sound Frequency by Using the Distributed Fiber Optic Sensor Net)

  • 이종길
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.569-576
    • /
    • 2004
  • In this paper, to detect external sound frequencies on the latticed structure, fiber optic sensor net using Sagnac interferometer was fabricated and tested. The latticed structure was fabricated with a dimension of 50 cm in width and 50 cm in height. The optical fiber of 50m in length was distributed and fixed on the surface of the latticed structure. Single mode fiber, a laser with 1,550 nm in wavelength, 2 ${\times}$ 2 coupler were used. External sound signal, 240 Hz, 495 Hz, 1.445 kHz, 2k Hz, applied to the fiber optic sensor net and the detected optical signals were compared to the detected microphone signals against time and frequency domains. Based on the experimental results, fiber optic sensor net using Sagnac interferometer detected external sound frequency, effectively. This system can be expanded to the structural health monitoring system.

스펙클 패턴을 이용한 반사형 광섬유 센서에 대한 연구 (A Study of the Reflection Type Optical Fiber Sensor Based on Speckle Detection)

  • 정은주;박재희
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.121-127
    • /
    • 2004
  • A reflection type optical fiber line sensor based on the speckle detection has been developed using the optical fiber mirror with the reflectance of 72 %. Some experiments were carried on with the automobile and the 500 m length multimod fiber. When the automobile passed on the fiber sensor, two abrupt changes of the output waveform occured like the transmission type sensor based on the speckle variations. The signal to noise ratio of this sensor was about 40 dB.

광섬유 센서를 이용한 섬유-금속 적층판의 손상 감지 (Damage Detection of Fiber-Metal Laminates Using Optical Fiber Sensors)

  • 양유창;한경섭
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.161-164
    • /
    • 2002
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Tensile test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. EFPI was less sensible to the damage signals compared with the optical fiber vibration sensor. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF

광섬유 센서를 이용한 구조물의 열변형 및 온도 측정 (Thermal Strain and Temperature Measurements of Structures by Using Fiber-Optic Sensors)

  • 강동훈;강현규;류치영;홍창선;김천곤
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 춘계학술발표대회 논문집
    • /
    • pp.184-189
    • /
    • 2000
  • Two types of fiber-optic sensors, EFPI(extrinsic Fabry-Perot interferometer) and FBG(fiber Bragg grating), have been investigated for measurement of thermal strain and temperature. The EFPI sensor is only for measurement of thermal strain and the FBG sensor is for simultaneous measurement of thermal strain and temperature. FBG temperature sensor was developed to measure strain-independent temperature. This sensor configuration consists of a single-fiber Bragg grating and capillary tube which makes it isolated from external strain. This sensor can then be used to compensate for the temperature cross sensitivity of a FBG strain sensor. These sensors are demonstrated by embedding them into a graphite/epoxy composite plate and by attaching them on aluminum rod and unsymmetric graphitelepoxy composite plate. All the tests were conducted in a thermal chamber with the temperature range $20-100^{\circ}C$. Results of strain measurements by fiber-optic sensors are compared with that from conventional resistive foil gauge attached on the surface.

  • PDF

A Fiber Optic Sensor for Determination of 2,4-Dichlorophenol Based on Oxygen Oxidation Catalyzed by Iron(III) Tetrasulfophthalocyanine

  • Tong, Yilin;Li, Dapeng;Huang, Jun;Zhang, Cong;Li, Kun;Ding, Liyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3307-3311
    • /
    • 2013
  • A new fiber optical sensor was developed for the determination of 2,4-dichlorophenol (DCP). The sensor was based on DCP oxidation by oxygen with the catalysis of iron(III) tetrasulfophthalocyanine (Fe(III)PcTs). The optical oxygen sensing film with $Ru(bpy)_3Cl_2$ as the fluorescence indicator was used to determine the consumption of oxygen in solution. A lock-in amplifier was used for detecting the lifetime of the oxygen sensing film by measuring the phase delay change of the sensor head. The different variables affecting the sensor performance were evaluated and optimized. Under the optimal conditions (i.e. pH 6.0, $25^{\circ}C$, Fe(III)PcTs concentration of 0.62 mg/mL), the linear detection range and response time of the sensor are $1.0{\times}10^{-6}-9.0{\times}10^{-6}$ mol/L and 250 s, respectively. The sensor displays high selectivity, good repeatability and stability, and can be used as an effective tool in analyzing DCP concentration in practical samples.

Temperature Compensation of a Strain Sensing Signal from a Fiber Optic Brillouin Optical Time Domain Analysis Sensor

  • Kwon, Il-Bum;Kim, Chi-Yeop;Cho, Seok-Beom;Lee, Jung-Ju
    • Journal of the Optical Society of Korea
    • /
    • 제7권2호
    • /
    • pp.106-112
    • /
    • 2003
  • In order to do continuous health monitoring of large structures, it is necessary that the distributed sensing of strain and temperature of the structures be measured. So, we present the temperature compensation of a signal from a fiber optic BOTDA (Brillouin Optical Time Domain Analysis) sensor. A fiber optic BOTDA sensor has good performance of strain measurement. However, the signal of a fiber optic BOTDA sensor is influenced by strain and temperature. Therefore, we applied an optical fiber on the beam as follows: one part of the fiber, which is sensitive to the strain and the temperature, is bonded on the surface of the beam and another part of the fiber, which is only sensitive to the temperature, is located nearby the strain sensing fiber. Therefore, the strains can be determined from the strain sensing fiber while compensating for the temperature from the temperature sensing fiber. These measured strains were compared with the strains from electrical strain gages. After temperature compensation, it was concluded that the strains from the fiber optic BOTDA sensor had good coincidence with those values of the conventional electrical strain gages.

Continuous deformation measurement for track based on distributed optical fiber sensor

  • He, Jianping;Li, Peigang;Zhang, Shihai
    • Structural Monitoring and Maintenance
    • /
    • 제7권1호
    • /
    • pp.1-12
    • /
    • 2020
  • Railway tracks are the direct supporting structures of the trains, which are vulnerable to produce large deformation under the temperature stress or subgrade settlement. The health status of track is critical, and the track should be routinely monitored to improve safety, lower the risk of excess deformation and provide reliable maintenance strategy. In this paper, the distributed optical fiber sensor was proposed to monitor the continuous deformation of the track. In order to validate the feasibility of the monitoring method, two deformation monitoring tests on one steel rail model in laboratory and on one real railway tack in outdoor were conducted respectively. In the model test, the working conditions of simply supported beam and continuous beam in the rail model under several concentrated loads were set to simulate different stress conditions of the real rail, respectively. In order to evaluate the monitoring accuracy, one distributed optical fiber sensor and one fiber Bragg grating (FBG) sensor were installed on the lower surface of the rail model, the strain measured by FBG sensor and the strain calculated from FEA were taken as measurement references. The model test results show that the strain measured by distributed optical fiber sensor has a good agreement with those measured by FBG sensor and FEA. In the outdoor test, the real track suffered from displacement and temperature loads. The distributed optical fiber sensor installed on the rail can monitor the corresponding strain and temperature with a good accuracy.