• Title/Summary/Keyword: a data acquisition and control

Search Result 645, Processing Time 0.028 seconds

Simultaneous Determination of Asperosaponins and Iridoid Glycosides from Dipsaci Radix by Using LC-ESI-MS Spectrometry (속단(Dipsaci Radix) 중 Asperosaponins 및 Iridoid glycosides의 LC-ESI-MS에 의한 동시분석)

  • Cho, Hwang-Eui;Son, In-Seop;Kim, Sun-Cheun;Son, Kun-Ho;Woo, Mi-Hee;Moon, Dong-Cheul
    • Korean Journal of Pharmacognosy
    • /
    • v.43 no.2
    • /
    • pp.137-146
    • /
    • 2012
  • Dipsaci Radix (Dipsacaceae) has been used as a tonic, an analgesic, anti-inflammatory and anti-complement agents in traditional herbal medicine for the therapy of low back pain, knee pain, rheumatic arthritis, traumatic hematoma, and bone fractures. A high-performance liquid chromatography-electrospray ionization-mass spectrometric method (HPLC-ESI-MS) was developed for the simultaneous quantitation method of the five compounds from the herbal drug: asperosaponin VI and asperosaponin XII (terpene glycosides), sweroside, loganin and dipsacus A(iridoid glycosides). HPLC separation of the analytes was achieved on a C18 column ($150{\times}2.0$ mm i.d., 5 ${\mu}m$) using the aqueous methanol containing 5 mM ammonium acetate with gradient flow of the mobile phase. Detection of the analytes was performed by positive ion electrospray ionization, and selected ion monitoring was used for data acquisition using m/z corresponding molecular adduct ion, $[M+NH_4]^+$ and $[M+H]^+$. Calibration graphs showed good linearity ($r^2$=0.9997) over the wide range of the analytes; intra- and inter-day precisions (RSD, %) were within 9.1% and the accuracy between 94.0-111.0%. Recoveries of the analytes through the assay procedure were in the range of 93.7-110.8%. Analytical results of the herbal drugs of Dipsaci Radix (17 samples) show wide distribution of the five marker compounds and clear difference of the species from Phlomidis Radix (4 samples). The developed method would provide a practical guide for the quality control of the herbal drug.

Image Measurement and Processing using Near-Range Passive Millimeter-wave Imaging System (근거리 수동 밀리미터파 이미징 시스템을 이용한 영상 측정과 영상처리)

  • Jung, Kyung Kwon;Yoon, Jin-Seob;Chae, Yeon-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.8
    • /
    • pp.159-165
    • /
    • 2015
  • In this paper, we designed and tested of the passive millimeter-wave imaging system in near range. The proposed passive millimeter-wave imaging system consists two parts. The first part is a 94 GHz band millimeter imaging sensor which is coupled to an antenna, two LNAs, and a diode detector. The second part is a control unit. The control unit is consists of the 2-axes Cartesian robot, the data acquisition (DAQ), and imaging program. The 2-axes Cartesian robot should be able to scan a 2-D image of the metalic tools, IC card and plastic objects, with a raster scanning method. The passive millimeter-wave image of $20{\times}20$ pixels is acquired within less than 60s, and is immediately displayed and stored for post processing.In order to improve the image quality, interpolation methods are applied.

Implementation of Fuzzy Controller for MFC (MFC의 퍼지제어기 구현)

  • Lee, Seok-Ki;Lee, Yun-Jung;Lee, Seung-Ha
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.5
    • /
    • pp.648-654
    • /
    • 2004
  • The Mass Flow Controller(MFC) has become crucial in semiconductor manufacturing equipments. It is an important element because the quality and the yield of a semiconductor process are decided by the accurate flow control of gas. Therefore, the demand for implementing the high speed and the highly accurate control of MFCs has been increasing. It is hard to find an article of the control algorithm applied to MFCs. But, it is known that commercially available MFCs adopt PID control algorithms. Particularly, when the system detects the flow by way of heat transfer, the MFC control problem includes the slow response and the nonlinearity. In this paper, MFC control algorithm with a superior performance to the conventional PID algorithm is discussed and the superiority is demonstrated through the experiment. A fuzzy controller was utilized in order to compensate the nonlinearity and the slow response, and the performance is compared with that of an MFC currently available in the market. The control system, in this paper, consists of a personal computer, the data acquisition board and the control algorithm carried out by LabWindows/CVI program on the PC. In addition, a method of estimating the actual flow from the sensor output with the slow response is presented. In conclusion, according to the result of the experiment, the proposed algorithm shows better accuracy and is faster than the conventional controller.

Automated Geometric Correction of Geostationary Weather Satellite Images (정지궤도 기상위성의 자동기하보정)

  • Kim, Hyun-Suk;Lee, Tae-Yoon;Hur, Dong-Seok;Rhee, Soo-Ahm;Kim, Tae-Jung
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.4
    • /
    • pp.297-309
    • /
    • 2007
  • The first Korean geostationary weather satellite, Communications, Oceanography and Meteorology Satellite (COMS) will be launched in 2008. The ground station for COMS needs to perform geometric correction to improve accuracy of satellite image data and to broadcast geometrically corrected images to users within 30 minutes after image acquisition. For such a requirement, we developed automated and fast geometric correction techniques. For this, we generated control points automatically by matching images against coastline data and by applying a robust estimation called RANSAC. We used GSHHS (Global Self-consistent Hierarchical High-resolution Shoreline) shoreline database to construct 211 landmark chips. We detected clouds within the images and applied matching to cloud-free sub images. When matching visible channels, we selected sub images located in day-time. We tested the algorithm with GOES-9 images. Control points were generated by matching channel 1 and channel 2 images of GOES against the 211 landmark chips. The RANSAC correctly removed outliers from being selected as control points. The accuracy of sensor models established using the automated control points were in the range of $1{\sim}2$ pixels. Geometric correction was performed and the performance was visually inspected by projecting coastline onto the geometrically corrected images. The total processing time for matching, RANSAC and geometric correction was around 4 minutes.

A Study on Development of Message Integration Bus for Supervisory Control And Data Acquisition (변전설비 감시제어시스템 메시지통합버스 개발에 관한 연구)

  • Oh, Do-Eun;Jung, Nam-Joon;Ko, Jong-Min;Song, Jae-Ju;Yang, Il-Kwon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.05a
    • /
    • pp.830-832
    • /
    • 2008
  • 변전설비 감시제어시스템은 그 목적상 실시간의 대규모 측정정보 취득을 목적으로 한다. 취득정보는 RTU(Remote Terminal Unit)를 통해서 감시제어시스템에 전달된 후 필요에 따라 해당 정보를 요청하는 애플리케이션들에게 다시 전송된다. 현재 감시제어시스템에 널리 사용되는 DNP(Distribute Network Protocol)는 취득포인트 정보와 취득값만 가지고 있으므로 포인트 리스트에 대한 정보가 없는 경우에는 취득한 데이터를 판독할 수 없다. 따라서 감시제어시스템을 구축하기 위해 우선 RTU에 감시 선로정보를 입력하고, 이 정보를 다시 감시제어시스템의 DB에 포인트 정보와 매핑을 수행해야만 한다. 또한, 새로운 애플리케이션에서 취득값을 얻기 위해서는 이들 포인트 정보와 매핑 정보를 가지고 있는 감시제어시스템의 DB에 직접 연결해야만 한다. 본 논문은 공통정보모델과 이를 기반으로 작성된 메시지 교환 표준 인터페이스를 이용하여 감시제어시스템 취득정보의 효과적인 교환이 가능한 메시지 통합버스에 대하여 기술한다.

A Study of Combustion Test Facility for LRE Using Hydrogen peroxide and Kerosene as Propellant (과산화수소/케로신 액체로켓엔진의 연소시험 설비 개발에 관한 연구)

  • Choi, Yu-Ri;Jeon, Jun-Su;Kim, Young-Mun;Ko, Young-Sung;Kim, Yoo;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.29-32
    • /
    • 2009
  • This study is for development combustion test facility of liquid rocket engine system using hydrogen peroxide/kerosene as propellent. For this new facility, we construct thrust measure system, propellent supply system, control and data acquisition system. To perform 200N liquid rocket engine combustion test, operation scenario and sequence were designed. Result of combustion test propellents were supplied to engine stably and confirm of development combustion test facility very well.

  • PDF

A Scheme on Internet-based Checking for Variant CNC Machines in Machine Shop

  • Kim, Dong-Hoon;Kim, Sun-Ho;Koh, Kwang-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1732-1737
    • /
    • 2004
  • This paper proposes Internet-based checking technique for machine-tools with variant CNC (Computerized Numerical Controller). According to the architecture of CNC, CNC is classified into two types such as CAC (Closed Architecture Controller) which is conventional CNC, and OAC (Open Architecture Controller) which is a recently introduced PC-based controller. CAC has a closed architecture and it is dependent on CNC vender specification. Because of this, it has been very difficult for users to implement an application programs in CNC domain. Therefore, an additionally special module is required for Internet-based application such as remote checking. In this case, web I/O embedded module can be efficiently applied for Internet-based checking. The module is directly attached to TCP/IP network for communication. In order to obtain the monitoring data of CNC machines, the I/O signals of the module are assigned to PLC (Programmable Logic Controller) input and output (I/O) signals within CNC domain. On the other hand, OAC has a PC-based open architecture and an additional module is not necessary for the connection with external site. Because of this, a simple DAU is just used for signal sensing and data acquisition without additional communication modules. For Internet-based remote checking of machine-tools with OAC, a user-defined daemon and application programs are implemented as the form of internal function within the PC-based controller. Internet communication is performed between the daemon program in CNC domain and web script programs in external server. Checking points defined in this research are classified into two categories such as structured point and operational point. The formal includes the vibration of bearing, temperature of spindle unit and another periodical management. And the latter includes oil checking, clamp locking/unlocking and machining on/off status.

  • PDF

Development of an Integrated Calorimeter Using Temperature Control Signals of a Bioreactor and On-line Measurement of Metabolic Heat of a Microbial Cultivation (발효조의 온도제어 신호를 이용한 직접열량계의 개발 및 대사열량의 온라인 측정)

  • Hong, Geon-Pyo;Heo, Won
    • KSBB Journal
    • /
    • v.14 no.5
    • /
    • pp.543-549
    • /
    • 1999
  • For development of an integrated calorimetric bio-reactor to measure the metabolic heat dissipated during cell growth, a 5 liter jar fermenter was modified to measure the pulse length of automatic temperature control signals to set heater on and off, and the to send them to computer to calculate the cumulative heat supplied. Cumulative heats for the calorimetric reactor in the absence of cell growth, were measured with varying conditions. The heat loss by the aeration was 30.9 kJ/vvm and the loss to ambient air was 10.5 kJ/L/hr/$^{\circ}C$. Cumulative heat was measued within $\pm$0.2% when testing with a small electri heater submerged in the reactor. Metabolic heat was measured to be 0.76 and 0.76 and 11.4kJ per g consumption of glucose during cultivation of S. cerevisiae and E. coli, respectively.

  • PDF

FPGA integrated IEEE 802.15.4 ZigBee wireless sensor nodes performance for industrial plant monitoring and automation

  • Ompal, Ompal;Mishra, Vishnu Mohan;Kumar, Adesh
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2444-2452
    • /
    • 2022
  • The field-programmable gate array (FPGA) is gaining popularity in industrial automation such as nuclear power plant instrumentation and control (I&C) systems due to the benefits of having non-existence of operating system, minimum software errors, and minimum common reason failures. Separate functions can be processed individually and in parallel on the same integrated circuit using FPGAs in comparison to the conventional microprocessor-based systems used in any plant operations. The use of FPGAs offers the potential to minimize complexity and the accompanying difficulty of securing regulatory approval, as well as provide superior protection against obsolescence. Wireless sensor networks (WSNs) are a new technology for acquiring and processing plant data wirelessly in which sensor nodes are configured for real-time signal processing, data acquisition, and monitoring. ZigBee (IEEE 802.15.4) is an open worldwide standard for minimum power, low-cost machine-to-machine (M2M), and internet of things (IoT) enabled wireless network communication. It is always a challenge to follow the specific topology when different Zigbee nodes are placed in a large network such as a plant. The research article focuses on the hardware chip design of different topological structures supported by ZigBee that can be used for monitoring and controlling the different operations of the plant and evaluates the performance in Vitex-5 FPGA hardware. The research work presents a strategy for configuring FPGA with ZigBee sensor nodes when communicating in a large area such as an industrial plant for real-time monitoring.

Effects of Formative Feedback Practice on Practice satisfaction, Learning motivation and Academic Self efficacy (자율실습에서 형성적 피드백이 간호대학생의 실습만족도, 학습동기 및 학업적 자기효능감에 미치는 효과)

  • Choi, Dong-Won;Park, Min-Jeong
    • Journal of Digital Convergence
    • /
    • v.17 no.11
    • /
    • pp.305-313
    • /
    • 2019
  • This study was a quasi-experimental design with a non-equivalent pre-post test that verified the effect of formative feedback practice on practice satisfaction, learning motivation and academic self efficacy for nursing students. 37 were assigned to an intervention group and 41 to a control group. Formative feedback practice was applied to intervention group and peer review smartphone videos was applied to control group. Data were analyzed using the SPSS/WIN 22.0 program. There was no significant difference in learning motivation between the groups, but there were a significant difference in practice satisfaction(t=-2.79, p=.007) and academic self efficacy(t=2.30, p=.024) between the pre-post scores of the experimental group. This is meaningful in that it is more effective to provide formative feedback practice than to provide peer review smartphone videos. Therefore, it is necessary to consider formative feedback practice for the acquisition of core fundamental nursing skills of nursing students.