• Title/Summary/Keyword: a calibration

Search Result 5,249, Processing Time 0.036 seconds

Robot Calibration with Joint Stiffness Parameters for the Enhanced Positioning Accuracy (위치 정밀도 향상을 위한 관절강성 파라미터 포함 로봇 캘리브레이션)

  • Kang, Hee-Jun;Shin, Sung-Won;Ro, Young-Shick;Suh, Young-Soo;Lim, Hyun-Kyu;Kim, Dong-Hyeok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.4
    • /
    • pp.406-410
    • /
    • 2008
  • This paper presents a new robot calibration algorithm with joint stiffness parameters for the enhanced positioning accuracy of industrial robot manipulators. This work is towards on-going development of an industrial robot calibration software which is able to identify both the kinematic and non-kinematic robot parameters. In this paper, the conventional kinematic calibration and its important considerations are briefly described first. Then, a new robot calibration algorithm which simultaneously identifies both the kinematic and joint stiffness parameters is presented and explained through a computer simulation with a 2 DOF manipulator. Finally, the developed algorithm is implemented to Hyundai HX165 robot and its resulting improvement of the positioning accuracy is addressed.

Calibration of gimballed inertial navigation systems using state estimation (상태변수 추정을 이용한 김발형 관성항법시스템의 교정기법에 대한 연구)

  • Kim, Gap-Jin;Song, Taek-Ryeol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.1
    • /
    • pp.62-67
    • /
    • 1998
  • Gimballed Inertial Navigation Systems(GINS) are sophisticated autonomous electro-mechanical systems which supply the position, velocity and attitude of the vehicle on which they are mounted. In order to maintain accuracy of outputs, the GINS are required to regularly calibrate senior errors. However, existing calibration methods take up a long time due to multiposition alignments needed to increase accuracy. A particular system formulation for calibration of a GINS is proposed to enhance system observability and thus to expedite calibration procedure. Performance of the proposed calibration method is compared with existing methods such as Schuler test and muliposition alignment. Simulation studies show the proposed system formulation associated with a suggested suboptimal filter is accurate as well as efficient in error identification essential to GINS calibration.

  • PDF

Sampling and Calibration Requirements for Optical Reflectance Soil Property Sensors for Korean Paddy Soils (광반사를 이용한 한국 논 토양 특성센서를 위한 샘플링과 캘리브레이션 요구조건)

  • Lee, Kyou-Seung;Lee, Dong-Hoon;Jung, In-Kyu;Chung, Sun-Ok;Sudduth, K.A.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.4
    • /
    • pp.260-268
    • /
    • 2008
  • Optical diffuse reflectance sensing has potential for rapid and reliable on-site estimation of soil properties. For good results, proper calibration to measured soil properties is required. One issue is whether it is necessary to develop calibrations using samples from the specific area or areas (e.g., field, soil series) in which the sensor will be applied, or whether a general "factory" calibration is sufficient. A further question is if specific calibration is required, how many sample points are needed. In this study, these issues were addressed using data from 42 paddy fields representing 14 distinct soil series accounting for 74% of the total Korean paddy field area. Partial least squares (PLS) regression was used to develop calibrations between soil properties and reflectance spectra. Model evaluation was based on coefficient of determination ($R^2$) root mean square error of prediction (RMSEP), and RPD, the ratio of standard deviation to RMSEP. When sample data from a soil series were included in the calibration stage (full information calibration), RPD values of prediction models were increased by 0.03 to 3.32, compared with results from calibration models not including data from the test soil series (calibration without site-specific information). Higher $R^2$ values were also obtained in most cases. Including some samples from the test soil series (hybrid calibration) generally increased RPD rapidly up to a certain number of sample points. A large portion of the potential improvement could be obtained by adding about 8 to 22 points, depending on the soil properties to be estimated, where the numbers were 10 to 18 for pH, 18-22 for EC, and 8 to 22 for total C. These results provide guidance on sampling and calibration requirements for NIR soil property estimation.

Application and Construction of PSP Calibration System (PSP 압력 측정 Calibration 시스템 구축 및 적용)

  • Jeon, Young-Jin;Seo, Hyung-Seok;Byun, Yung-Hwan;Lee, Jae-Woo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.99-102
    • /
    • 2007
  • Pressure Sensitive Paint(PSP) means a reacting paint in pressure. The calibration of PSP and the wind tunnel test of PSP painted model are required to measure pressure using by PSP. Therefore, the post processing from these results shows the information and image of the pressure distribution. PSP can show the information of total pressure from the wind tunnel test and the calibration. In this study, equipments of PSP are composed, and calibration is accomplished using by PSP. Results of design and manufacturing calibration chamber till ability of advance calibration system study.

  • PDF

Design of a 1.2V 7-bit 800MSPS Folding-Interpolation A/D Converter with Offset Self-Calibration (Offset Self-Calibration 기법을 적용한 1.2V 7-bit 800MSPS Folding-Interpolation A/D 변환기의 설계)

  • Kim, Dae-Yun;Moon, Jun-Ho;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.3
    • /
    • pp.18-27
    • /
    • 2010
  • In this paper, a 1.2V 7-bit 1GSPS A/D converter with offset self-calibration is proposed. The proposed A/D converter structure is based on the folding-interpolation whose folding rate is 2, interpolation rate is 8. Further, for the purpose of improving the chip performance, an offset self-calibration circuit is used. The offset self-calibration circuit reduce the variation of the offset-voltage,due to process mismatch, parasitic resistor, and parasitic capacitance. The chip has been fabricated with a 1.2V 65nm 1-poly 6-metal CMOS technology. The effective chip area is $0.87mm^2$ and the power dissipates about 110mW at 1.2V power supply. The measured SNDR is about 39.1dB when the input frequency is 250MHz at 800MHz sampling frequency. The measured SNDR is 3dB higher than the same circuit without any calibration.

Calibration Mirror Mechanism with Fail-Safe Function (결함안전 기능을 고려한 교정 반사경 구동장치)

  • Lee, Kyong-Min;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.7
    • /
    • pp.682-687
    • /
    • 2011
  • Calibration mirror mechanism has been widely used for on-board calibration with black body. The calibration mirror is deployed to reflect the radiation energy from the black body to the image sensor for calibrating the sensor system. After the calibration, the calibration mirror is stowed not to hide a main optical path. It also has a fail-safe function which can stow the mirror by just removing the input power of motor when the calibration mirror is stopped at certain position during the calibration. In the present work, the operation concept, design, torque analysis and functional test results of the calibration mirror mechanism with the aforementioned function have been introduced and investigated.

A 2-D Image Camera Calibration using a Mapping Approximation of Multi-Layer Perceptrons (다층퍼셉트론의 정합 근사화에 의한 2차원 영상의 카메라 오차보정)

  • 이문규;이정화
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.4
    • /
    • pp.487-493
    • /
    • 1998
  • Camera calibration is the process of determining the coordinate relationship between a camera image and its real world space. Accurate calibration of a camera is necessary for the applications that involve quantitative measurement of camera images. However, if the camera plane is parallel or near parallel to the calibration board on which 2 dimensional objects are defined(this is called "ill-conditioned"), existing solution procedures are not well applied. In this paper, we propose a neural network-based approach to camera calibration for 2D images formed by a mono-camera or a pair of cameras. Multi-layer perceptrons are developed to transform the coordinates of each image point to the world coordinates. The validity of the approach is tested with data points which cover the whole 2D space concerned. Experimental results for both mono-camera and stereo-camera cases indicate that the proposed approach is comparable to Tsai's method[8]. Especially for the stereo camera case, the approach works better than the Tsai's method as the angle between the camera optical axis and the Z-axis increases. Therefore, we believe the approach could be an alternative solution procedure for the ill -conditioned camera calibration.libration.

  • PDF

Single-Phase Energy Metering Chip with Built-in Calibration Function

  • Lee, Youn-Sung;Seo, Jeongwook;Wee, Jungwook;Kang, Mingoo;Kim, Dong Ku
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.8
    • /
    • pp.3103-3120
    • /
    • 2015
  • This paper presents a single-phase energy metering chip with built-in calibration function to measure electric power quantities. The entire chip consists of an analog front end, a filter block, a computation engine, a calibration engine, and an external interface block. The key design issues are how to reduce the implementation costs of the computation engine from repeatedly used arithmetic operations and how to simplify calibration procedure and reduce calibration time. The proposed energy metering chip simplifies the computation engine using time-division multiplexed arithmetic units. It also provides a simple and fast calibration scheme by using integrated digital calibration functionality. The chip is fabricated with 0.18-μm six-layer metal CMOS process and housed in a 32-pin quad-flat no-leads (QFN) package. It operates at a clock speed of 4096 kHz and consumes 9.84 mW in 3.3 V supply.

In-process calibration system suitable for unattended turning cells (자동 선삭 셀에 적합한 인프로세스 측정/ 검사 시스템)

  • 김선호;김선호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.804-808
    • /
    • 1991
  • In a transfer line with mass production capability, calibration systems are included in the process as a separate dedicated station. However, this method is not appropriate in an unattended FMC with flexibility. As the FMC produces vesatile parts with small batch sizes, more flexible calibration systems are required. In this paper, a calibration/inspection system suitable for an unattended turning cell is introduced. The system has functions of dimension calibration of parts by touch probes, tool wear compensation, and quality monitoring of parts. Furthermore, characteristics of errors in the system are identified and corresponding compensation methodology is suggested. An operation software was developed for efficient use of the system.

  • PDF

In-house calibration of pressure transducers and effect of material thickness

  • Dave, Trudeep N.;Dasaka, S.M.
    • Geomechanics and Engineering
    • /
    • v.5 no.1
    • /
    • pp.1-15
    • /
    • 2013
  • Pressure transducers are increasingly used within soil mass or at soil-structure interface for appraisal of stresses acting at point of installation. Calibration of pressure transducers provides a unique relationship between applied pressure and voltage or strain sensed by transducer during various loading conditions and is crucial for proper interpretation of results obtained from pressure transducers. In the present study an in-house calibration device is used to calibrate pressure transducers and the study is divided into two parts: 1) demonstration of developed calibration device for fluid and in-soil calibration of pressure transducers; 2) effect of soil layer thickness on the earth pressure cell (EPC) output. Results obtained from the present study revealed successful performance of the developed calibration device, and significant effect of sand layer thickness on the calibration results. The optimum sand layer thickness is obtained as 1.5 times the diameter of EPC.