• Title/Summary/Keyword: a attached mass

Search Result 360, Processing Time 0.025 seconds

Spontaneous Regression of Eyelid Histiocytoma in a Maltese Dog

  • Kim, Boyun;Lim, Jaegook;Shim, Jae-ho;Seo, Kangmoon;Kang, Seonmi
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.121-125
    • /
    • 2022
  • A 1-year-old neutered male Maltese dog was presented with a mass on the upper eyelid of the left eye (OS). A pinkish and alopecic mass was located in the nasal portion of the upper eyelid of OS. The mass was firmly attached to the eyelid and round-shaped with a diameter of 11 mm. Any spread to conjunctiva was not identified. On a cytological examination, cutaneous histiocytoma was confirmed, with the presence of small lymphocytes indicating later regression stage. The patient received no treatment and complete regression of the mass was verified 2 months later. The cytological examination was helpful for the diagnosis and staging of cutaneous histiocytoma. Canine eyelid histiocytoma can regress spontaneously, and thus medical or surgical treatment for removal should be considered carefully.

Effects of Discrete Rib-Turbulators on Heat/Mass Transfer Augmentation in a Rectangular Duct (사각 덕트 내부 열전달 향상을 위한 요철의 단락 효과)

  • Kwon, Hyuk-Jin;Wu, Seong-Je;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.744-752
    • /
    • 2000
  • The influence of arrangement and length of discrete ribs on heat/mass transfer and friction loss is investigated. Mass transfer experiments are conducted to obtain the detailed local heat/mass transfer information on the ribbed wall. The aspect ratio (width/height) of the duct is 2.04 and the rib height is one tenth of the duct height, such that the ratio of the rib height to hydraulic diameter is 0.0743. The ratio of rib-to-rib distance to rib height is 10. The discrete ribs were made by dividing each continuous rib into 2, 3 or 5 pieces and attached periodically to the top and the bottom walls of the duct with a parallel orientation The combined effects of rib angle and length of the discrete ribs on heat/mass transfer ae considered for the rib angles $({\alpha})\;of\;90^{\circ}\;and\;45^{\circ}$. As the number of the discrete ribs increases, the uniformity of the heat/mass transfer distributions increases. For $(\alpha})=90^{\circ}$, the heat/mass transfer enhancement with the discrete ribs is remarkable, while the heat/mass transfer performances are slightly higher than that of the transverse continuous ribs due to the accompanied high friction loss penalty. For $(\alpha})=90^{\circ}$, the average heat/mass transfer coefficients and the heat/mass transfer performances decrease slightly with the discrete ribs compared to the case of the angled continuous ribs.

A study on the behavior of frost formation according to surface characteristics in the fin-tube heat exchanger (핀-관 열교환기의 표면특성에 따른 착상 거동에 관한 연구)

  • 류수길;이관수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.377-383
    • /
    • 1999
  • In this study, the behavior of frost formation according to surface characteristics in the fin-tube heat exchanger has been examined experimentally. The results show that the thickness of the frost which is attached to the hydrophilic heat exchanger becomes thin and the air pressure drop is smaller than that of bare aluminium heat exchanger However, the frost mass of hydrophilic heat exchanger is more than the bare one. Hence, high density frost is attached to hydrophilic heat exchanger. The sensible and latent heat flux of hydrophilic heat exchanger is bigger than that of bare one, but the increasing amount is very small and the improvement of thermal performance is also very small. The variation of fin-pitch of heat exchanger shows little influence on frost formation and hydrophilic heat exchanger loses its surface characteristics rapidly with increasing relative humidity.

  • PDF

Diurnal Changes in the Distribution of Ruminal Bacteria Attached to Feed Particles in Sheep Fed Hay Once Daily

  • Pan, J.;Suzuki, T.;Ueda, K.;Tanaka, K.;Okubo, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.12
    • /
    • pp.1708-1716
    • /
    • 2000
  • A study was made of diurnal changes in the ruminal bacteria associated with feed particles, i.e., non-associated (NAB), loosely associated (LAB), and tightly associated with particles (TAB), and the TAB concentration in different particle sizes from sheep fed orchardgrass (OG) or alfalfa (ALF) hay. Diaminopimelic acid (DAPA) was used to determine the TAB mass. Results showed that the bacterial masses in NAB and LAB were small, but comprised over 90% in TAB. The TAB mass in the ALF group sharply increased within 2 h after feeding and decreased afterward. The TAB mass showed the same trend in the OG group, increasing from 0 h to 2 h, but remained at the same level up to 14 h after feeding. The peak bacterial mass was, however, lower in the OG than the ALF group. The TAB concentration reflected the changes in total particulate tightly associated bacterial masses in both groups of hay fed sheep. Number of bacterial colonies per particle increased as the particulate size decreased in both groups. This difference, however, tended to decline as the postprandial period was prolonged. DAPA, however, tended to overestimate the TAB mass in the reticulo-rumen digesta of the hay fed sheep.

Vibration control performance of particle tuned mass inerter system

  • Zheng Lu;Deyu Yan;Chaojie Zhou;Ruifu Zhang
    • Structural Engineering and Mechanics
    • /
    • v.89 no.4
    • /
    • pp.383-397
    • /
    • 2024
  • To improve the vibration control performance and applicability of traditional particle tuned mass damper (PTMD) and realize the significant characteristic of lightweight design, this study proposes a novel particle tuned mass inerter system (PTMIS) by introducing inerter system (IS) to the PTMD. In the study, the motion equation of single degree of freedom (SDOF) structure attached with PTMIS is established first, then the variation law of the system's vibration reduction performance (VRP) is discussed through parameter analysis, and it is compared with the PTMD to analyze its VRP advantages. Finally, its vibration reduction (VR) mechanism from the perspective of core control force and energy analysis is explored, and its cavity relative displacement from the application perspective is analyzed. The results show that the PTMIS can remarkably improve the vibration control effectiveness of the PTMD. The reason is that the inerter can store energy and transfer the energy to the cavity and particles, which further stimulates the interaction between the two parts, thereby improving the nonlinear energy consumption effectiveness. Also, the IS can amplify the damping element's energy dissipation efficiency. In addition, the PTMIS can effectively reduce the working stroke of the PTMD, and through the analysis of the lightweight characteristics of the PTMIS, it is found that its lightweight advantage can reach nearly 100%.

Development and characteristics investigation of new soft plasma ionization(SPI) source (새로운 소프트 플라스마 이온화(SPI) 장치의 개발 및 특성관찰)

  • Lee, Hiwwon;Park, Hyunkook;Lee, Sang Chun
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.152-158
    • /
    • 2009
  • In this study, we made a new discharge source improving previous SPI source to ionize softly organic compounds. The new SPI source consists of two electrodes as a hollow mesh cathode of half cylindrical shape and a hollow anode. We optimized the geometrical parameter of the SPI source by investigating the I-V curves at the various distance between the cathode and the anode. As the results, we found stable conditions of the soft plasma on broad range of the current and the voltage. The new SPI source attached to quadrupole mass spectrometer (QMS), and we obtained the mass spectra of dichloromethane (DCM). The fragment patterns of DCM appeared similarly with the pattern of electron ionization (EI).

Quantitative Alpha Fetoprotein Detection with a Piezoelectric Microcantilever Mass Sensor (압전 마이크로캔틸레버 질량센서를 이용한 정량적 알파태아단백 검출)

  • Lee, Sangk-Yu;Cho, Jong-Yun;Lee, Yeol-Ho;Jeon, Sang-Min;Cha, Hyung-Joon;Moon, Wonk-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.487-493
    • /
    • 2011
  • Alpha fetoprotein(AFP), which is serological marker for hepatocellular carcinoma, was quantitatively measured by its normal concentration, 10 ng/ml, with a label-free piezoelectric microcantilever mass sensor. The principle of detection is based on changes in the resonant frequency of the piezoelectric microcantilever before and after target molecules are attached to it, and its resonant frequency is measured electrically using a conductance spectrum. The resonant frequency of the developed sensor is approximately 1.34 MHz and the mass sensitivity is approximately 175 Hz/pg. The sensor has high reliability as mass sensor by reducing the effect of surface stress on resonant frequency due to attached proteins. 'Dip and dry' technique was used to react the sensor with reagents for immobilizing AFP antibody on the sensor and detecting AFP antigen. The measured mass of the detected AFP antigen was 6.02 pg at the concentration of 10 ng/ml, and 10.67 pg at 50 ng/ml when the immunoreaction time was 10 min.

Active tuned tandem mass dampers for seismic structures

  • Li, Chunxiang;Cao, Liyuan
    • Earthquakes and Structures
    • /
    • v.17 no.2
    • /
    • pp.143-162
    • /
    • 2019
  • Motivated by a simpler and more compact hybrid active tuned mass damper (ATMD) system with wide frequency spacing (i.e., high robustness) but not reducing the effectiveness using the least number of ATMD units, the active tuned tandem mass dampers (ATTMD) have been proposed to attenuate undesirable oscillations of structures under the ground acceleration. Likewise, it is expected that the frequency spacing of the ATTMD is comparable to that of the active multiple tuned mass dampers (AMTMD) or the multiple tuned mass dampers (MTMD). In accordance with the mode generalised system in the specific vibration mode being controlled (simply referred herein to as the structure), the closed-form expression of the dimensionless displacement variances has been derived for the structure with the attached ATTMD. The criterion for the optimum searching may then be determined as minimization of the dimensionless displacement variances. Employing the gradient-based optimization technique, the effects of varying key parameters on the performance of the ATTMD have been scrutinized in order to probe into its superiority. Meanwhile, for the purpose of a systematic comparison, the optimum results of two active tuned mass dampers (two ATMDs), two tuned mass dampers (two TMDs) without the linking damper, and the TTMD are included into consideration. Subsequent to work in the frequency domain, a real-time Simulink implementation of dynamic analysis of the structure with the ATTMD under earthquakes is carried out to verify the findings of effectiveness and stroke in the frequency domain. Results clearly show that the findings in the time domain support the ones in the frequency domain. The whole work demonstrates that ATTMD outperforms two ATMDs, two TMDs, and TTMD. Thereinto, a wide frequency spacing feature of the ATTMD is its highlight, thus deeming it a high robustness control device. Furthermore, the ATTMD system only needs the linking dashpot, thus embodying its simplicity.

Entrapment Neuropathy of Median and Ulnar Nerve Due to Soft Tissue Chondroma: A Case Report (연부조직 연골종에 의한 정중, 척골포착신경병증: 증례보고)

  • Hong, Sung-Taek;Ahn, Duck-Sun
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.815-818
    • /
    • 2010
  • Purpose: Soft tissue chondroma is a rare benign tumor, found mainly on the palm and sole and grows slowly. Typically, mature hyaline cartilage is the dominant pathological feature. There are reports that assert soft tissue chondromas to be a cause of median nerve entrapment syndrome. However, this is the first case report showing soft tissue chondroma to be a cause of simultaneous median and ulnar neuropathy. Methods: A 62 year-old woman presented with chief complaints of numbness and hypoesthesia of her right palm for 4 to 5 years, and a palpable mass on her right palm that had been increasing in size slowly for 3 years. Physical examination revealed a firm, mobile, non-tender and about $3{\times}3\;cm^2$ sized mass in the center of the right palm. Electromyography showed entrapment neuropathy of the median and ulnar nerve. Ultrasonography showed an approximately $5.7\;cm^2$ mass below the flexor tendon of ring finger. Upon surgical excision, a $3{\times}3\;cm^2$ mass attached to the flexor digitorum profundus of ring finger and redness and hypertrophy of both the median and ulnar nerve were discovered. Mass excision was performed gently and the specimen was referred for histopathologic study. Mass excision resulted in median and ulnar nerve release. Results: The pathology report confirmed the mass to be a soft tissue chondroma with mature hyaline cartilage. The patient exhibited post-operative improvement of her symptoms and did not show any complications. Conclusion: This is the first case report showing soft tissue chondroma to be a cause of simultaneous median and ulnar neuropathy.

Development of an Automatic Sorting System Driven by Friction Force

  • Ko, Min-Seok;Lee, Jeong-Wook;Kim, Jung-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.90.5-90
    • /
    • 2002
  • In this research, we are trying to develop an automatic sorting system, which is mostly affected by frictional forces between a veneer and plank. So we will make a suitable dynamic model and mechanism to control the velocity feedback. We will suggest stick-slip motion model which can predict the stability behavior of this system. The control system has a feedback loop, in which the following operations are included. A kind of sensor can get the velocity of the mass to adhesive veneer. The output of result signal should be passed to a filter, then to a phase shifter, which applies an adjustable phase-shift, to a variable-gain amplifier. A shaker will be attached to the mass, which ex...

  • PDF