• Title/Summary/Keyword: a and b values

Search Result 6,893, Processing Time 0.037 seconds

The Measurement Method of Thermal Conductivity and Diffusivity of Thin Paint Layer Sprayed on Solid Surface (고체표면에 도포한 도료 박막의 열전도율과 열확산율의 측정법)

  • Kim, Eun-young;Park, Soo-Chun;Kim, Byung-Mun;Lee, Doug-Bong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.311-319
    • /
    • 1999
  • The thermal conductivity ${\lambda}_b$, thermal diffusivity ${\alpha}_b$ of the thin black paint layer sprayed on solid surface and absorptivity a for laser beam are measured by applying a non-contact measurement method of the thermophysical properties of solids. The values of a=0.67, ${\lambda}_b=1.45W/mK$ and ${\alpha}_b=1.24{\times}10^{-6}m^2/s$ are obtained for the sprayed lay~ thickness $z_b{\fallingdotseq}40\;{\mu}m$. Furthermore, for the $z_b{\fallingdotseq}24\;{\mu}m$ thick layers which arc formed by rubbing with a glass rod after spraying, the values of a=0.73, ${\lambda}_b=1.85W/mK$. and ${\alpha}_b=1.09{\times}10^{-6}m^2/s$ are obtained. It is also shown that the present thermal diffusivity ${\alpha}_b$ for $z_b{\fallingdotseq}40\;{\mu}m$ Is about 30~80% larger than those obtained by Araki et al. for the thicker layer $z_b{\fallingdotseq}150{\sim}248\;{\mu}m$. This method could be applied to the measurement of thermophysical properties of thin layer on solids.

Chlorophyll a/b Ratio as a Criterion for the Reliability of Absorbance Values Measured for the Determination of Chlorophyll Concentration (엽록소 농도 결정을 위하여 측정한 흡광도 값의 신뢰도 검정 지표로서 엽록소 a/b 비례치)

  • Wu, Guangxi;Lee, Choon-Hwan
    • Journal of Life Science
    • /
    • v.29 no.5
    • /
    • pp.509-513
    • /
    • 2019
  • The Beer-Lambert law states that absorbance is proportional to the concentration of a solute in a solution at a given wavelength. This linearity works for an ideal or a 'sufficiently diluted' solution, so this linearity is often used as a criterion for the fidelity of the absorbance value measured. In this study, we used a chlorophyll (Chl) solution, isolated from rice leaves with 80% acetone to test the use of the Chl a/b ratio as an additional criterion for checking the fidelity of measured values using four different absorption spectrophotometers: Cary4E, UV-1650PC, Versamax (a microplate reader), and NanoDrop 1,000(which can handle a $4{\mu}l$ aliquot). We used Chl solutions of varying concentrations from $0.2{\mu}g/ml$ to $200{\mu}g/ml$ to measure absorbance values at 645 nm and 663 nm and checked the linearity first. The results indicated that the range of Chl concentrations that we can rely on based on the linearity was similar to the range in which the calculated Chl concentrations based on the measured absorbance values agreed with the known concentrations. However, some border cases or cases with very low Chl concentrations inside the fidelity range of Chl concentrations did not agree with the criterion that the Chl a/b ratio should not change after dilution of the Chl in the solution. These results suggest that the Chl a/b ratio is a better criterion for the reliability of the absorbance values measured for the determination of chlorophyll concentration than the criterion based on the linearity suggested by the Beer-Lambert law.

Mass Interception Fractions and Weathering Half-lives of Iodine-131 and Radiocesium in Leafy Vegetables Observed after the Fukushima Daiichi Nuclear Power Plant Accident

  • Tagami, Keiko;Uchida, Shigeo
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.178-183
    • /
    • 2021
  • Background: This study was carried out to provide environmental transfer parameter values to estimate activity concentrations of these radionuclides in agricultural crops when direct contamination occurred. Materials and Methods: Mass interception fractions (FBs) and weathering half-lives (Tws) of 131I and radiocesium were calculated using openly available monitoring data obtained after the Fukushima Daiichi Nuclear Power Plant accident. FB is the ratio between the initial radioactivity concentration of a radionuclide retained by the edible part of the plant (Bq·kg-1 fresh weight [FW]) and the amount of deposited radionuclide in that area (Bq·m-2). Tw values can be calculated using activity concentrations of crops decreased with time after the initial contamination. Results and Discussion: Calculated FB and Tw values for 131I and radiocesium were mostly obtained for leafy vegetables. The analytical results showed that there was no difference of FBs between 131I and radiocesium by t-test; geometric mean values for leafy vegetables cultivated under outdoor conditions were 0.058 and 0.12 m2·kg-1 FW, respectively. Geometric mean Tw value of 131I in leafy vegetables grown under outdoor conditions was 8.6 days, and that of radiocesium was 6.6 days; there was no significant difference between Tw values of these radionuclides by Wilcoxon rank sum test. Conclusion: There was no difference between 131I and radiocesium for FBs and Tws. By using these factors, we would be able to carry out a rough estimation of the activity concentrations of 131I and radiocesium in the edible part of leafy crops when a nuclear accident occurred.

The Piezoelectic and electromechanical Characteristics of PZ-PT-PMWS (PZ-PT-PMWS의 압전 및 전기기계적 특성)

  • 홍종국;이종섭;채홍인;윤만순;정수현;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.403-406
    • /
    • 2000
  • The piezoelectric properties and the doping effect of N $b_2$ $O_{5}$ and Mn $O_2$for 0.95PbZ $r_{x}$ $Ti_{x}$ $O_3$+0.05Pb(M $n_{0.42}$ $W_{0.26}$S $b_{0.32}$) $O_3$ compositions have been investigated. In the composition of 0.95PbZ $r_{0.54}$ $Ti_{0.46}$ $O_3$+0.05Pb(M $n_{0.42}$ $W_{0.26}$S $b_{0.32}$) $O_3$the Values Of $k_{p}$ find and $\varepsilon$$_{33}$ $^{T}$ are maximized, but $Q_{m}$ Was minimized ( $k_{p}$ =0.51, $Q_{m}$ =1750). The grain size was suppressed and the uniformity of grain was improved with doping concentration of N $b_2$ $O_{5}$ for 0.95PbZ $r_{0.54}$ $Ti_{0.46}$ $O_3$+0.005Pb(M $n_{0.42}$ $W_{0.26}$S $b_{0.32}$) $O_3$sample. The values of $k_{p}$ increased and the values of $Q_{m}$ slightly decreased when 0.5 wt% of N $b_2$ $O_{5}$ is doped. And the values of $k_{p}$ was the same formation of the N $b_2$ $O_{5}$ dopant when 0.5 wt% of M $n_2$ $O_{5}$ is doped. But the values of $Q_{m}$ was deeply decreased when 0.5 wt% of Mn $O_2$is doped. As a experiment results under high electric field driving, this piezoelectric ceramics are very stable. Conclusively, piezoelectric ceramic compsiton investigated at this paper is suitable for application to high power piezoelectric devices.. devices..ices.. devices..

  • PDF

Quantitative, qualitative Evaluation of Diffusion-Weighted MRI using Optimal b-value(s/mm2) for Female Pelvis (여성골반에 대한 최적의 b-value(s/mm2)를 이용한 확산강조 자기공명영상의 정량적, 성적 평가)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.361-368
    • /
    • 2013
  • The purpose of this study is to know the clinical usefulness of optimal b-values by quantitative, qualitative evaluation of DW-MRI for lesions of benignity and malignity of female pelvis. The b-values used in DWI were 600, 800, 1000, 1200, 1400($s/mm^2$). Mean SNR and CNR of myoma in b-value 800 were the highest result as $84.6{\pm}4.57$(p=0.024) and $50.13{\pm}5.47$(p=0.028), Mean SNR and CNR of cervical cancer were the highest result as $12.0{\pm}2.04$(p=0.047) and $10.6{\pm}1.24$(p=0.001), Mean ADC value in myoma and cervical cancer in b-value 800 were $1.19{\times}10^{-3}mm^2/s$(p=0.008), $0.96{\times}10^{-3}mm^2/s$(p=0.027). As a qualitative analysis, the delineation and conspicuity were the highest result as $4.02{\pm}0.18$(p=0.028), $4.39{\pm}0.25$(p=0.015) on b-value 800. DW-MRI is an important method, and the optimal b values is 800 $s/mm^2$ for differentiation between benign and malignant lesions of female pelvis.

Another Approach to Stereo Matching - Fuzzification of Feature Values (또다른 접근방식에 의한 스테레오 정합 - 특정 값의 퍼지화)

  • 김동현;최우영;박래홍
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.11
    • /
    • pp.925-933
    • /
    • 1991
  • Conventional stereo matching techniques are based on the assumption that the features representing an object in left and right images have fixed attribute values. But, in fact, such features may take different values due to the practical stereo image formation and the image acquisition error, and thus the conventional techniques tend to result in the in the incorrect matching of features. In this paper, we propose a stereo matching mathod with a possibilistic view which copes with the possible variability of feature values. As a result, this method decreases the number of incorrect matching features when the values of corresponding features are somewhat large. The effectiveness of the proposed method is shown via computer simulation.

  • PDF

Effects of geometrical parameters on the degree of bending in two-planar tubular DYT-joints of offshore jacket structures

  • Hamid Ahmadi;Mahdi Ghorbani
    • Ocean Systems Engineering
    • /
    • v.13 no.2
    • /
    • pp.97-121
    • /
    • 2023
  • Through-the-thickness stress distribution in a tubular member has a profound effect on the fatigue behavior of tubular joints commonly found in steel offshore structures. This stress distribution can be characterized by the degree of bending (DoB). Although multi-planar joints are an intrinsic feature of offshore tubular structures and the multi-planarity usually has a considerable effect on the DoB values at the brace-to-chord intersection, few investigations have been reported on the DoB in multi-planar joints due to the complexity of the problem and high cost involved. In the present research, data extracted from the stress analysis of 243 finite element (FE) models, verified based on available parametric equations, was used to study the effects of geometrical parameters on the DoB values in two-planar tubular DYT-joints. Parametric FE study was followed by a set of nonlinear regression analyses to develop six new DoB parametric equations for the fatigue analysis and design of axially loaded two-planar DYT-joints.

DUALITY OF WEIGHTED SUM FORMULAS OF ALTERNATING MULTIPLE T-VALUES

  • Xu, Ce
    • Bulletin of the Korean Mathematical Society
    • /
    • v.58 no.5
    • /
    • pp.1261-1278
    • /
    • 2021
  • Recently, a new kind of multiple zeta value of level two T(k) (which is called multiple T-value) was introduced and studied by Kaneko and Tsumura. In this paper, we define a kind of alternating version of multiple T-values, and study several duality formulas of weighted sum formulas about alternating multiple T-values by using the methods of iterated integral representations and series representations. Some special values of alternating multiple T-values can also be obtained.

Correlation between Vertebral Left Atrial Size and NT-proBNP in Dogs with Myxomatous Mitral Valve Disease

  • Chae, Dong-Jin;Han, Sung-Hyun;Song, Kunho
    • Journal of Veterinary Clinics
    • /
    • v.38 no.5
    • /
    • pp.215-220
    • /
    • 2021
  • The purpose of this study was to investigate the correlation between vertebral left atrial size (VLAS) and NT-proBNP levels. Sixty-three dogs with myxomatous mitral valve disease (MMVD) were recruited for this study. The MMVD group was classified according to the ACVIM stage based on medical history, clinical signs, and thoracic radiography and echocardiography findings. The N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels were measured using fluorescent immunoassay. VLAS and VHS values were measured using a digital caliper in the right lateral view. There were significant differences in VLAS for each American college of veterinary internal medicine (ACVIM) stage (p < 0.01). As the ACVIM stage increased, it tended to increase. Vertebral heart score (VHS) also showed a tendency to increase with the ACVIM stage (p < 0.01). VLAS was divided into three groups: VLAS <2.6, 2.6≤ VLAS <3.1, and VLAS ≥3.1. NT-proBNP values were significantly different between the three groups (p < 0.01), and VLAS and NT-proBNP values showed a strong positive correlation (r = 0.756, p < 0.01). In conclusion, there were significant differences among ACVIM stages B1 and B2, B1 and C-D, and B2 and C-D groups regarding VLAS. Furthermore, NT-proBNP increased proportionally as VLAS increased. Measurements of VLAS may be helpful in the diagnosis of MMVD in addition to the existing radiological and echocardiographic methods.

Color Look-Up Table Design for Gamut Mapping and Color Space Conversion (색역 사상과 색공간 변환을 위한 칼라 참조표 설계)

  • 김윤태;조양호;이호근;하영호
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.2
    • /
    • pp.1-10
    • /
    • 2004
  • This paper proposes the method that design CLUT(color look-up table) simultaneously processing gamut mapping and color space conversion using only CLUT without complex computation. After CLUT is constructed using scanner gamut and printer gamut, the scanner gamut is extended to include original scanner gamut. This extended scanner gamut is used as input CIE $L^{*}$ $a^{*}$ $b^{*}$ values for CLUT. Then CMY values are computed by using gamut mapping. Input RGB image of scanner is converted into CIE $L^{*}$ $a^{*}$ $b^{*}$ by using regression function. CIE $L^{*}$ $a^{*}$ $b^{*}$ values of scanner are converted into CMY values without computation of additional gamut mapping using the proposed CLUT. In the experiments, the proposed method resulted in the similar color difference, but reduced the complexity computation than the direct computing method to process gamut mapping and color space conversion respectively.espectively.ively.