• Title/Summary/Keyword: a J-lead

Search Result 710, Processing Time 0.03 seconds

Estimation of Lead Exposure Intensity by Industry Using Nationwide Exposure Databases in Korea

  • Koh, Dong-Hee;Park, Ju-Hyun;Lee, Sang-Gil;Kim, Hwan-Cheol;Jung, Hyejung;Kim, Inah;Choi, Sangjun;Park, Donguk
    • Safety and Health at Work
    • /
    • v.12 no.4
    • /
    • pp.439-444
    • /
    • 2021
  • Background: In a previous study, we estimated exposure prevalence and the number of workers exposed to carcinogens by industry in Korea. The present study aimed to evaluate the optimal exposure intensity indicators of airborne lead exposure by comparing to blood lead measurements for the future development of the carcinogen exposure intensity database. Methods: Data concerning airborne lead measurements and blood lead levels were collected from nationwide occupational exposure databases, compiled between 2015 and 2016. Summary statistics, including the arithmetic mean (AM), geometric mean (GM), and 95th percentile level (X95) were calculated by industry both for airborne lead and blood lead measurements. Since many measurements were below the limits of detection (LODs), the simple replacement with half of the LOD and maximum likelihood estimation (MLE) methods were used for statistical analysis. For examining the optimal exposure indicator of airborne lead exposure, blood lead levels were used as reference data for subsequent rank correlation analyses. Results: A total of 19,637 airborne lead measurements and 32,848 blood lead measurements were used. In general, simple replacement showed a higher correlation than MLE. The results showed that AM and X95 using simple replacement could be used as optimal exposure intensity indicators, while X95 showed better correlations than AM in industries with 20 or more measurements. Conclusion: Our results showed that AM or X95 could be potential candidates for exposure intensity indicators in the Korean carcinogen exposure database. Especially, X95 is an optimal indicator where there are enough measurements to compute X95 values.

A Study on the Design, Fabrication and Characteristics Test of 25KJ Superconducting Magnetic Energy Storage (25KJ 초전도 에너지 저장장치의 설계,제작 및 특성 시험)

  • 홍원표;원종수;이송엽;이승원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.10
    • /
    • pp.683-693
    • /
    • 1988
  • For the economical and reasonable operation of electric power system according to continual increase of electric power demand and decrease of load factor, the potential application of superconducting magnertic energy storage [SMES] with high efficiency and fast response in the electric utility is receiving attractive attension. In the light of this background, to confirm the basic principle of SMES, theoretical study, design technique and fabrication procedure for superconducting coil, current lead, cryostat, measuring and protection system of SMES are described in detail. Especially, a new design technique for superconducting coil and current lead is porposed and it was proved experimentally by the performance test of SMES which is developed for the first time in our country. At the peak operating current 200A, the maximum magnetic field amd stored energy of the coil are 3.52T and 2500J, espectively. The thermal and mechanical stability of 2500J SMES is also confirmed experimetally by its characteristics test, AC loss, protection system, charge and discharge test. The experimetal results show good characteristics of energy storage system.

  • PDF

Determining a BMDL of Blood Lead Based on ADHD Scores Using a Semi-Parametric Regression

  • Kim, Ah-Hyoun;Ha, Min-A;Kim, Byung-Soo
    • The Korean Journal of Applied Statistics
    • /
    • v.25 no.3
    • /
    • pp.389-401
    • /
    • 2012
  • This paper derives a benchmark dose(BMD) and its 95% lower confidence limit(BMDL) using a semi-parametric regression model for small lead based changes in attention-deficit hyperactivity disorder(ADHD) scores in the first wave of the Children's Health and Environment Research(CHEER) survey data, which have been regularly collected in South Korea since 2005. Ha et al. (2009) showed that the appearance of ADHD symptoms had a borderline trend of increasing with the blood lead concentration. Butdz-J${\o}$rgensen (EFSA, 2010a) derived the BMDL of lead corresponding to a benchmark region of 1 full intelligent quotient (IQ) score using the raw data in Lanphear et al. (2005, EHP). European Food Safety Authority (EFSA, 2010b) determined the BMDL of $1.2{\mu}g/dl$ as a reference point for the characterization of lead when assessing the risk of the intellectual deficit measured by IQ scores. Kim et al. (2011) indicated that an even lower BMDL could be obtained based on the ADHD score; however, the BMDLs depended heavily upon the model assumptions. We show in this paper that a semi-parametric approach resolves the model dependence of BMDLs.

Development of Progressive Die CAD/CAM System for Manufacturing Lead Frame, Semiconductor (반도체 리드 프레임 제조를 위한 프로그레시브 금형의 CAD/CAM 시스템 개발)

  • Choi, J.-C.;Kim, B.-M.;Kim, C.;Kim, J.-H.;Kim, C.-B.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.12
    • /
    • pp.230-238
    • /
    • 1999
  • This paper describes a research work of developing computer-aided design of lead frame, semiconductor, with blanking operation which is very precise for progressive working. Approach to the system is based on the knowledge-based rules. Knowledge for the system is formulated from plasticity theories, experimental results and the empirical knowledge of field experts. This system has been written in AutoLISP on the AutoCAD using a personal computer and in I-DEAS Drafting Programming Language on the I-DEAS Master Series Drafting with Workstation, HP9000/715(64) and tool kit on the ESPRIT. Transference of data among AutoCAD, I-DEAS Master Series Drafting, and ESPRIT is accomplished by DXF(drawing exchange format) and IGES(initial graphics exchange specification) methods. This system is composed of six modules, which are input and shape treatment, production feasibility check, strip-layout, die-layout, modelling, and post-processor modules. The system can design process planning and Die design considering several factors and generate NC data automatically according to drawings of die-layout module. As forming process of high precision product and die design system using 2-D geometry recognition are integrated with technology of process planning, die design, and CAE analysis, standardization of die part in die design and process planning of high pression product for semiconductor lead frame is possible to set. Results carried out in each module will provide efficiencies to the designer and the manufacturer of lead frame, semiconductor.

  • PDF

Optimal Arrangement of Current Leads for 24kV class SFCL to Minimize Electromagnetic Force (전자기력을 고려한 24kV급 초전도 한류기용 전류리드의 최적화 배열방안)

  • Kim, J.H.;Song, J.B.;Hwang, S.J.;Kim, K.L.;Kim, H.M.;Kim, H.R.;Hyun, O.B.;Ko, T.K.;Lee, H.G.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.62-66
    • /
    • 2007
  • Electromagnetic forces (Attractive and repulsive force), interacting between current leads show different tendency according to the arrangement of current leads on the top flange of the cryostat and the distance of each lead. Especially in case of high-current electric power devices or high-field magnets, optimal arrangement of current leads becomes one of the safety issues to be considered for minimizing the electromagnetic for ce acting on them. In this paper, we suggest an optimal arrangement method with three pairs of current leads for a 24kV class 650A superconducting fault current limiter (SFCL) system which has a probability of unpredicted fault currents(i.e, 20kA).

A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy (Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구)

  • Song, Jong-Nam;Seol, Gwang-Wook;Hong, Seong-Il;Choi, Jeong-Gu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.135-141
    • /
    • 2011
  • If protective performance of apron cannot be good, radiation exposure of an guardian or a patient, a person engaged in radiation related industry cannot rise. Therefore, It will be evaluated protection performance to radiation protection aprons by manufacturers and lead equivalent more than 0.25mm lead equivalent. And, will show in the direction of application to clinic. The new aprons by manufacturers(H, X, I, J company) and lead equivalent(0.50mmPb, 0.35mmPb, 0.25mmPb) measured transmitted dose rate and shielding rate, uniformity under fluoroscopy and general radiography using to fluoroscopy system and digital radiography system, x-ray multifunction meter. The shielding rate measurement results, 0.5mmPb apron was Shielding rate of apron of a I company(fluoroscopy : 97.96%) was the best under six companies, and shielding rate of apron of a J company(fluoroscopy : 96.25%) was worst. 0.35mmPb Apron was Shielding rate of a I company(fluoroscopy : 96.79%) was the best under the three companies, and shielding rate of an H company(fluoroscopy : 95.81%) was the worst. 0.25mmPb Apron was Shielding rate of X company apron(fluoroscopy : 90.908%) was better than H company apron(fluoroscopy : 88.82%) than two companies. The uniformity measurement results, 0.5mmPb Aprons of X company(fluoroscopy : 0.13) and I company(fluoroscopy : 0.19) was the best under the six companies, and J company apron(fluoroscopy : 0.45) was the worst. 0.35mmPb. Along a manufacturer and lead equivalent performance of apron protection is distinguished certainly. Therefore, a patient, guardian or a person engaged in radiation related industry shall enforce experiment of a lot of ways defined or evaluation so that the maximum reduces radiation exposure. Buy the apron that protective performance is good, It will be performed through experiment and evaluation.

Development and validation of the lead-bismuth cooled reactor system code based on a fully implicit homogeneous flow model

  • Ge Li;Wang Jingxin;Fan Kun;Zhang Jie;Shan Jianqiang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1213-1224
    • /
    • 2024
  • The liquid lead-bismuth cooled fast reactor has been in a single-phase, low-pressure, and high-temperature state for a long time during operation. Considering the requirement of calculation efficiency for long-term transient accident calculation, based on a homogeneous hydrodynamic model, one-dimensional heat conduction model, coolant flow and heat transfer model, neutron kinetics model, coolant and material properties model, this study used the fully implicit difference scheme algorithm of the convection-diffusion term to solve the basic conservation equation, to develop the transient analysis program NUSOL-LMR 2.0 for the lead-bismuth fast reactor system. The steady-state and typical design basis accidents (including reactivity introduction, loss of flow caused by main pump idling, excessive cooling, and plant power outage accidents) for the ABR have been analyzed. The results are compared with the international system analysis software ATHENA. The results indicate that the developed program can stably, accurately, and efficiently predict the transient accident response and safety characteristics of the lead-bismuth fast reactor system.