  • Background: Although the zygomatic arch is an important structure determining facial prominence and width, no consensus exists regarding the classification of isolated zygomatic arch fractures, and the literature on this topic is scarce. To date, five papers have subdivided zygomatic arch fractures; however, only one of those proposed classifications includes the injury vector, although the injury vector is one of the most important factors to consider in fracture cases. Furthermore, the only classification that does include the injury vector is too complicated to be suitable for daily practice. In addition, the existing classifications are clinically limited because they do not consider greenstick fractures, nondisplaced fractures, or coronoid impingement. In the present study, we present a rearrangement of the previously published classifications and propose a modified classification of isolated zygomatic arch fractures that maximizes the advantages and overcomes the disadvantages of previous classification systems. Methods: The classification criteria for isolated zygomatic arch fractures described in five previous studies were analyzed, rearranged, and supplemented to generate a modified classification. The medical records, radiographs, and facial bone computed tomography findings of 134 patients with isolated zygomatic arch fractures who visited our hospital between January 2010 and December 2019 were also retrospectively analyzed. Results: We analyzed major classification criteria (displacement, the force vector of the injury, V-shaped fracture, and coronoid impingement) for isolated zygomatic arch fracture from the five previous studies and developed a modified classification by subdividing zygomatic arch fractures. We applied the modified classification to cases of isolated zygomatic arch fracture at our hospital. The surgery rate and injury severity differed significantly from fracture types I to VI. Conclusion: Using our modified classification, we could determine that both the injury force and the injury vector meaningfully influenced the surgery rate and the severity of the injuries.

Zygomaticomaxillary buttress and its dilemma

  • Malaviya, Pallavi;Choudhary, Sandeep
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제44권4호
    • /
    • pp.151-158
    • /
    • 2018
  • Zygomatic fractures are the second most common fractures of the facial skeleton, after nasal bone fractures. Due to its uniqueness, the malar bone plays a very important role in maintaining appropriate facial contours. Zygomatic fractures can cause ocular and mandibular functional impairment, along with cosmetic defects. With the help of advanced imaging techniques and various treatment options, the management of zygomatic fractures has become more sophisticated and less invasive. This article discusses zygomatic fractures in detail: their clinical and radiographic features, and the various treatment options available.

Effectiveness of Dual-Maneuver Using K-Wire and Dingman Elevator for the Reduction of Unstable Zygomatic Arch Fracture

  • Yoon, Hyungwoo;Kim, Jiye;Chung, Seum;Chung, Yoon-Kyu
    • 대한두개안면성형외과학회지
    • /
    • 제15권2호
    • /
    • pp.59-62
    • /
    • 2014
  • Background: The zygoma is the most prominent portion of the face. Almost all simple zygomatic arch fractures are treated in a closed fashion with a Dingman elevator. However, the open approach should be considered for unstable zygomatic arch fractures. The coronal approach for a zygomatic arch fracture has complications. In this study, we introduce our method to reduce a special type of unstable zygomatic fracture. Methods: We retrospectively reviewed zygomatic arch view and facial bone computed tomography scans of 424 patients who visited the Wonju Severance Christian Hospital from 2007 to 2010 with zygomaticomaxillary fractures, among whom 15 patients met the inclusion criteria. Results: We used a Dingman elevator and K-wire simultaneously to manage this type of zygomatic arch fracture. Simple medial rotation force usually collapses the posterior fractured segment, and the fracture becomes unstable. Thus, the posterior fracture segment must be concurrently elevated with a Dingman elevator through Keen's approach with rotation force applied through the K-wire. All fractures were reduced without any instability using this method. Conclusion: We were able to reduce unstable and difficult zygomatic arch fractures without an open incision or any external fixation device.

Reduction of Zygomatic Fractures Using the Carroll-Girard T-bar Screw

  • Baek, Ji Eun;Chung, Chan Min;Hong, In Pyo
    • Archives of Plastic Surgery
    • /
    • 제39권5호
    • /
    • pp.556-560
    • /
    • 2012
  • Zygomatic fractures are the second most common facial bone fractures encountered and treated by plastic surgeons. Stable fixation of fractured fragments after adequate exposure is critical for ensuring three-dimensional anatomic reduction. Between January 2008 and December 2010, 17 patients with zygomatic fractures were admitted to our hospital; there were 15 male and 2 female patients. The average age of the patients was 41 years (range, 19 to 75 years). We exposed the inferior orbital rim and zygomatic complex through a lateral brow, intraoral, and subciliary incisions, which allowed for visualization of the bone, and then the fractured parts were corrected using the Carroll-Girard T-bar screw. Postoperative complications such as malar asymmetry, diplopia, enophthalmos, and postoperative infection were not observed. Lower eyelid retraction and temporary ectropion occurred in 1 of the 17 patients. Functional and cosmetic results were excellent in nearly all of the cases. In this report, we describe using the Carroll-Girard T-bar screw for the reduction of zygomatic fractures. Because this instrument is easy to use and can rotate to any direction and vector, it can be used to correct displaced zygomatic bone more accurately and safely than other devices, without leaving facial scars.

Inferomedially impacted zygomatic fracture reduction by reverse vector using an intraoral approach with Kirschner wire

  • Jang, Jin Woo;Cho, Jaeyoung;Burm, Jin Sik
    • Archives of Plastic Surgery
    • /
    • 제48권1호
    • /
    • pp.69-74
    • /
    • 2021
  • Background In inferomedially rotated zygomatic fractures sticking in the maxillary sinus, it is often difficult to achieve complete reduction only by conventional intraoral reduction. We present a new intraoral reduction technique using a Kirschner wire and its clinical outcome. Methods Among 39 inferomedially impacted zygomatic fractures incompletely reduced by a simple intraoral reduction trial with a bone elevator, a Kirschner wire (1.5 mm) was vertically inserted from the zygomatic body to the lateral orbital rim in 17 inferior-dominant rotation fractures and horizontally inserted to the zygomatic arch in nine medial-dominant and 13 bidirectional rotation fractures. A Kirschner wire was held with a wire holder and lifted in the superolateral or anterolateral direction for reduction. Following reduction of the zygomaticomaxillary fracture, internal fixation was performed. Results Fractures were completely reduced using only an intraoral approach with Kirschner wire reduction in 33 cases and through an additional lower lid or transconjunctival incision in six cases. There were no surgical complications except in one patient with undercorrection. Postoperative 6-month computed tomography scans showed complete bone union and excellent bone alignment. Four patients experienced difficulty with upper lip elevation; however, these problems spontaneously resolved after manual tissue lump massage and intralesional steroid (Triamcinolone) injection. Conclusions We completely reduced infraorbital rim fractures, zygomaticomaxillary buttresses, and zygomaticofrontal suture fractures in 84% of patients through an intraoral approach alone. Intraoral Kirschner wire reduction may be a useful option by which to obtain effective and powerful reduction motion of an inferomedially rotated zygomatic body.

Surgical Methods of Zygomaticomaxillary Complex Fracture

  • Ji, So Young;Kim, Seung Soo;Kim, Moo Hyun;Yang, Wan Suk
    • 대한두개안면성형외과학회지
    • /
    • 제17권4호
    • /
    • pp.206-210
    • /
    • 2016
  • Background: Zygoma is a major buttress of the midfacial skeleton, which is frequently injured because of its prominent location. Zygoma fractures are classified according to Knight and North based on the direction of anatomic displacement and the pattern created by the fracture. In zygomaticomaxillary complex (ZMC) fracture many incisions (lateral eyebrow, lateral upper blepharoplasty, transconjunctival, subciliary, subtarsal, intraoral, direct percutaneous approach) are useful. We reviewed various approaches for the treatment of ZMC fractures and discussed about incisions and fixation methods. Methods: A retrospective review was conducted of patients with ZMC fracture at a single institution from January 2005 to December 2014. Patients with single zygomatic arch fracture were excluded. Results: The identified 694 patients who were admitted for zygomatic fractures from which 192 patients with simple arch fractures were excluded. The remaining 502 patients consisted of 439 males and 63 females, and total 532 zygomatic bone was operated. Orbital fracture was the most common associated fracture. According to the Knight and North classification the most frequent fracture was Group IV. Most fractures were fixated at two points (73%). Conclusion: We reviewed our cases over 10 years according to fracture type and fixation methods. In conclusion, minimal incision, familiar approach and fixation methods of the surgeon are recommended.

Clinical Follow-up on Sagittal Fracture at the Temporal Root of the Zygomatic Arch: Does It Need Open Reduction?

  • Cheon, Ji Seon;Seo, Bin Na;Yang, Jeong Yeol;Son, Kyung Min
    • Archives of Plastic Surgery
    • /
    • 제40권5호
    • /
    • pp.546-552
    • /
    • 2013
  • Background The zygoma is a major portion of the midfacial contour. When deformity occurs in this area, a reduction should be conducted to correct it. If a sagittal fracture at the temporal root of the zygomatic arch occurs, this also requires reduction, but it is difficult to approach due to its anatomical location, and the possibility of fixation is also limited. Thus, the authors attempted the reduction of sagittal fracture by two- or three-point fixation and the Gillies approach without direct manipulation. The preoperative and postoperative results of the patients were evaluated. Follow-up was performed to establish a treatment guideline. Methods A retrospective study was done with 40 patients who had sagittal fractures at the temporal root of the zygomatic arch from March 2009 to June 2012. Only two- or three-point fixation was performed for the accompanying zygomatic-orbital-maxillary fracture. The Gillies approach was used for complex fractures of the zygomatic arch, while the temporal root of the zygomatic arch was only observed without reduction. Preoperative and postoperative computed tomography and X-ray scans were performed to examine the results. Results The result of the paired t-test on preoperative and postoperative bone gap differences, the depression level, and the degree of temporal protrusion showed a marked decrease in the mean difference at a 95% confidence interval. The results were acceptable. Conclusions In the treatment of sagittal fractures at the temporal root of the zygomatic arch, it is acceptable to use indirect reduction and non-fixation methods. This leads to a satisfactory aesthetic and functional outcome.

Wire or Hook Traction for Reducing Zygomatic Fracture

  • Ahn, Hee Chang;Youn, Dong Hyun;Choi, Matthew Seung Suk;Chang, Jung-Woo;Lee, Jang Hyun
    • 대한두개안면성형외과학회지
    • /
    • 제16권3호
    • /
    • pp.131-135
    • /
    • 2015
  • Background: Variable methods have been introduced for reduction of the zygomatic fractures. The Dingman elevator is used widely to reduce these fractures but is inappropriate in certain types of fractures which require atypical traction vectors. We introduce and examine an alternate method of reducing zygomatic fractures using wire and hook traction. Methods: A retrospective study was performed for all zygomatic fracture patients admitted between 2008 and 2014. Medially rotated fractures were reduced by using a wire looped through an intermaxillary screw secured on the medial side of the zygoma. Laterally rotated fractures were reduced using a hook introduced through an infrazygomatic skin incision. Results: No accidental bleeding or incomplete reduction was observed in any of the cases. Postoperative imaging demonstrated proper reduction immediately after the operation. Follow-up computed tomography study at 1 month after operation also demonstrated proper reduction and healthy union across the previous site of fracture. Conclusion: The hook and wire method allowed precise application of traction forces across zygomatic fractures. The fractured bone fragment could be pulled in the direction precisely opposite to the vector of impact at the time of trauma. Soft tissue damage due to dissection was minimized. In particular, this method was effective in reducing rotated bone fragments and can be an alternative option to using the zygoma elevator.

An Anthropometric and Three-Dimensional Computed Tomographic Evaluation of Two-Point Fixation of Zygomatic Complex Fractures

  • Jo, Taehee;Kim, Junhyung
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.493-499
    • /
    • 2014
  • Background Maintaining stability and restoring the aesthetic appearance are the fundamental goals when managing zygomatic fractures. We aimed to evaluate the stability and anthropometric outcomes of zygomatic fracture patients who underwent two-point fixation involving the infraorbital rim and zygomaticomaxillary buttress via the transconjunctival and gingivobuccal approaches without any skin incisions. Methods We examined 15 zygomatic fracture patients who underwent two-point fixation during a 3-year period. Stability was evaluated using three-dimensional facial bone computed tomography. Superoinferior and anteroposterior displacement of the zygoma was quantified. The aesthetic appearance of the periorbital region was evaluated using indirect anthropometry with standardized clinical photographs. The ratios between the eye fissure height and width, and lower iris coverage ratio were used to evaluate aesthetical changes. The bony displacement and aesthetic ratios were analyzed using Wilcoxon or Friedman tests. The correlation between the preoperative zygoma position and anthropometric values was analyzed. Results The positions of the zygoma were similar to those on the contralateral side at the long-term follow-up. The preoperative anthropometric measurements on the fractured side differed from those on the contralateral side, although these values were close to the normal values at the long-term follow-up. Furthermore, we noted that the anteroposterior displacement strongly positively correlated with the lower iris coverage rate (Spearman's coefficient=0.678, P=0.005). Conclusions Two-point fixation of zygomatic fractures achieved stable outcomes on long-term follow-up, and also appeared to be reliable in restoring the aesthetic appearance of the periorbital region.

관골 골절의 양상 및 정도에 관한 임상적 연구 (A CLINICAL STUDY ABOUT NATURE AND SEVERITY OF THE ZYGOMATIC BONE FRACTURES)

  • 류수장;김미숙;노기문
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권2호
    • /
    • pp.211-218
    • /
    • 2000
  • This is a retrospective study on the nature and severity of zygomatic bone fractures. This study was based on a series of 358 patients with zygomatic bone fractures who treated as in-patient at Soonchunhyang Chonan Hospital during the period of Jan. 1993 through Dec. 1996. The results obtained are as follows : 1. The ratio of men to women was 4.41:1. The age frequency was highest in the second, third decade. The yearly distribution was the highest in 1993. The monthly distribution was highest in Feb. and Jun. 2. The most frequent cause was the traffic accident.(66.2%) 3. The most frequent type of fractures was the class I(undisplaced fx.).(25%) 4. The most frequent associated oral and maxillofacial injuries was soft tissue.(46.9%) 5. The most frequent associated systemic injuries was upper, lower extremity.(38%) 6. In A.I.S of oral and maxillofacial area, the mean score of A.I.S was $2.5{\sim}3$. In I.S.S, the highest mean score was in the ped TA.(19) 7. In respect of treatment, the most common method was open reduction with rigid fixation on fronto-zygomatic suture area.(47.8%) 8. The incidence of complication was 12% and the most common complication was malunion.(6.1%)