• Title/Summary/Keyword: Zoom Lens Calibration

Search Result 12, Processing Time 0.021 seconds

Zoom Lens Calibration for a Video Measuring System (컴퓨터 비젼을 이용한 정밀 측정 장비의 줌 렌즈 캘리브레이션)

  • Hahn, Kwang-Soo;Choi, Joon-Soo;Choi, Ki-Won
    • Journal of Internet Computing and Services
    • /
    • v.6 no.5
    • /
    • pp.57-71
    • /
    • 2005
  • Precise visual measurement applications, like video measuring system (VMS), use camera systems with motorized zoom lens for fast and efficient measurement. In this paper, we introduce an efficient calibration method for zoom lens of VMS controlled by servo motor. For the automated zoom lens calibration of the VMS, only zoom lens setting needs to be calibrated and parameters calibrated by zoom lens settings are image center and pixel size changed by zoom levels, The extrinsic parameters, like focus and iris, do not need to be calibrated since the parameters are usually fixed, It needs a lot of time and effort to calibrate the camera for ali the different zoom levels. In this paper, we also propose an efficient and fast zoom lens calibration method, which calculates the calibration parameters of the zoom lens settings for the minimum number of zoom levels and estimates other parameters for the uncalculated zoom levels using the interpolation of the calculated parameter values.

  • PDF

Zoom Lens Distortion Correction Of Video Sequence Using Nonlinear Zoom Lens Distortion Model (비선형 줌-렌즈 왜곡 모델을 이용한 비디오 영상에서의 줌-렌즈 왜곡 보정)

  • Kim, Dae-Hyun;Shin, Hyoung-Chul;Oh, Ju-Hyun;Nam, Seung-Jin;Sohn, Kwang-Hoon
    • Journal of Broadcast Engineering
    • /
    • v.14 no.3
    • /
    • pp.299-310
    • /
    • 2009
  • In this paper, we proposed a new method to correct the zoom lens distortion for the video sequence captured by the zoom lens. First, we defined the nonlinear zoom lens distortion model which is represented by the focal length and the lens distortion using the characteristic that lens distortion parameters are nonlinearly and monotonically changed while the focal length is increased. Then, we chose some sample images from the video sequence and estimated a focal length and a lens distortion parameter for each sample image. Using these estimated parameters, we were able to optimize the zoom lens distortion model. Once the zoom lens distortion model was obtained, lens distortion parameters of other images were able to be computed as their focal lengths were input. The proposed method has been made experiments with many real images and videos. As a result, accurate distortion parameters were estimated from the zoom lens distortion model and distorted images were well corrected without any visual artifacts.

A Study of Camera and Robot Calibration for Fine Image Acquisition (정밀영상 획득을 위한 카메라와 로봇 보정에 관한 연구)

  • Jung, Won;Park, Jong-Rak
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 1999.12a
    • /
    • pp.493-505
    • /
    • 1999
  • Zoom lens camera calibration is an important and difficult problem for two reason at least. First, the intrinsic parameters of such a camera change over time, it is difficult to calibration them on-line. Secondly, the pin-hole model for single lens system can not be applied directly to a zoom lens system. In this paper, We address some aspects of this problem.

  • PDF

Evaluation for Geometric Calibration Accuracy of Zoom-lens CCD Camera (줌렌즈 CCD 카메라의 기하학적 검정 정확도 평가)

  • 유환희;정상용;김성삼
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.3
    • /
    • pp.245-254
    • /
    • 2003
  • Zoom lenses CCD(Charge Coupled Device) cameras have many desirable features but appear to be geometrically unstable and diffcult to calibrate. It is well blown that the zooming camera parameters change with zoom lens position. This paper presents a comparative study of two approaches, namely, DLT(Direct Linear Transformation) introduced by Abdel-Aziz and Karara and the model proposed by Tsai, to evaluate the camera parameters of zoom lenses CCD camera and 3D positioning accuracy. As a result, the accuracy for 3D positioning using Tsai and DLT model is similar in both methods when the set of GCPs and the object are arranged in the same space. However, Tsai model is more stable than DLT in the case that the object is apart from the set of GCPs. Also, the further study for the parameters optimization of conventional DLT is needed to improve accuracy for 3D positioning.

Empirical Modeling of Lens Distortion in Change of Focal Length (초점거리 변화에 따른 렌즈 왜곡의 경험적 모델링)

  • Jeong, Seong-Su;Woo, Sun-Kyu;Heo, Joon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.1
    • /
    • pp.93-100
    • /
    • 2008
  • The parameters of lens such as focal length, focus, and aperture stop changes while shooting the scenes with zoom lens. Especially, zooming action dramatically changes the geometry of lens system that causes significant change of lens model. We investigated how the lens model changes while zooming in general shooting condition. Each parameters of lens model was estimated and checked whether they can be modeled well in the condition of auto-controlling focus, aperture and vibration reduction. In order to do this, calibration images were taken, modeled in different fecal length setting. And changing patterns of models were inspected to find out if there is some elements that have some particular pattern in changing with respect to focal length. The result showed us that although we didn't control the focus and aperture setting, there's specific changing patterns in radial and do-centering distortion. Especially, the strong linear correlation was found between coefficient of $r^2$ and focal length. It is expected that many parts of distortion can be eliminated without additional self calibration even if zoom operation is done when shooting the scenes if we know its fecal length and model of this coefficient.

PRACTICAL WAYS TO CALCULATE CAMERA LENS DISTORTION FOR REAL-TIME CAMERA CALIBRATION

  • Park, Seong-Woo;Hong, Ki-Sang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.125-131
    • /
    • 1999
  • In this paper, we address practical methods for calculating camera lens distortion for real time applications. Although the lens distortion problem can be easily ignored for constant-parameter lenses, in the field of real-time camera calibrations, for zoom lenses a large number of calculations are needed to calculate the distortion. However, if the distortion can be calculated independently of the other camera parameter, we can easily calibrate a camera without the need for a large number of calculations. Based on Tsai's camera model, we propose two different methods for calculating lens distortion. These methods are so simple and require so few calculations that the lens distortion can be rapidly calculated even in real-time applications. The first method is to refer to the focal length - lens distortion Look Up Table(LUT), which is constructed in the initialization process. The second method is to use the relationship between the feature points found in the image. Experiments were carried out for both methods, results of which show that the proposed methods are favorably comparable in performance with non-real full optimization method.

Calculation of Longitudinal Aberrations in Decentered Optical System with Non-symmetrical Elements (비대칭 오차요인이 있는 편심 광학계에서의 종수차 계산)

  • Ryu, Jae-Myung;Jo, Jae-Heung;Kang, Geon-Mo;Lee, Hae-Jin;Yoneyama, Suji
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.4
    • /
    • pp.151-160
    • /
    • 2010
  • When the optical image stabilization is implemented by moving one of the lens groups in a zoom system, decentration should be considered in the optical design process. Although it is partially possible to calibrate optical performances in an optical system with non-symmetrical elements by using a lot of commercial software, the results of calibrating longitudinal aberrations have some calibration errors because of the lack of precise consideration of decentered optical systems. In particular, the amount of distortion in paraxial ray tracing is different from the experimental value because paraxial ray tracing in the optical system is not useful. In this paper, in order to solve this problem being from various commercial lens design software, the set of equations of paraxial ray tracing in a zoom lens system with the non-symmetrical elements like decentration or tilt are theoretically induced. Then, the methods to calibrate the equations of longitudinal aberrations by using these equations in a non-symmetrical optical system are presented. The method of calibrating longitudinal aberrations can in practice be used to correct hand shaking effects in a zoom lens system.

The Development of adaptive optical dimension measuring system (적응형 광학 치수 측정 장치 개발)

  • 윤경환;강영준;백성훈;강신재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.690-695
    • /
    • 2004
  • A new dimension measuring method for the measurement of diameter of an object has been developed using laser triangulation. The 3-D data of an object was calculated from the 2dimensional image information obtained by the laser stripe using the laser triangulation. The system can measure the diameter of hole not only in a normal plane but also in an incline plane. We can experiment with magnification that is optimized according to size of object using zoom lens. In this paper, the theoretical formula and calibration of the system were described. The measuring precision of the system was investigated by experiment.

  • PDF

Zoom Lens Calibration for the Video Measuring System (VMS에서의 줌 렌즈 캘리브레이션)

  • 최기원;이호준;한광수;최준수
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10b
    • /
    • pp.625-627
    • /
    • 2003
  • 본 논문에서는 정밀 측정 장비인 VMS(Video Measuring System)에서 줌을 서보 모터(servo motor)로 제어하는 자동화된 줌 렌즈 보정에 대하여 연구하였다. 이전의 자동화된 줌 렌즈의 연구들은 줌, 초점과 조리개 3 가지의 렌즈 설정에 대한 모든 카메라 파라미터들에 대하여 보정하였지만, VMS 의 자동화된 줌 렌즈의 보정은 줌의 렌즈 설정에 대해서만 보정한다. 줌 렌즈 설정에 의해 보정 되는 파라미터들은 줌에 따라 변화하는 이미지 중심과 픽셀 크기이다. 카메라의 외부 파라미터들을 제외한 이유는 VMS에서는 카메라가 움직이고 않고, 스테이지가 움직이면서 그에 따른 좌표 값을 주기 때문에 카메라의 이동과 회전에 대하여 보정할 필요가 없다. 줌을 조정하는 줌 단계가 많기 때문에 모든 줌 단계를 보정하기 위해서는 많은 시간과 노력이 든다. 본 논문에서는 보정 파라미터들을 최소 단계의 줌 렌즈 설정에 대하여 계산하고 계산되지 않은 영역들을 보간법으로 빠르고 효과적인 줌 렌즈 보정을 할 수 있는 방법을 제안하였다.

  • PDF

Real-Time Camera Tracking for Virtual Stud (가상스튜디오 구현을 위한 실시간 카메라 추적)

  • Park, Seong-Woo;Seo, Yong-Duek;Hong, Ki-Sang
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.7
    • /
    • pp.90-103
    • /
    • 1999
  • In this paper, we present an overall algorithm for real-time camera parameter extraction which is one of key elements in implementing virtual studio. The prevailing mechanical methode for tracking cameras have several disadvantage such as the price, calibration with the camera and operability. To overcome these disadvantages we calculate camera parameters directly from the input image using computer-vision technique. When using zoom lenses, it requires real time calculation of lens distortion. But in Tsai algorithm, adopted for camera calibration, it can be calculated through nonlinear optimization in triple parameter space, which usually takes long computation time. We proposed a new method, separating lens distortion parameter from the other two parameters, so that it is reduced to nonlinear optimization in one parameter space, which can be computed fast enough for real time application.

  • PDF