• Title/Summary/Keyword: Zone 3

Search Result 6,050, Processing Time 0.032 seconds

English Zone Education Methodology Utilizing the Wireless Internet (무선인터넷을 활용한 English Zone 영어 학습 방법 연구)

  • Lee, Il Seok
    • Journal of Digital Contents Society
    • /
    • v.16 no.3
    • /
    • pp.407-415
    • /
    • 2015
  • Offline English Zone refers to a physical environment in which the learners can check the results while they practice speaking and listening in English, and look up the vocabulary and information on their own. However, offline English zone is inevitably dependent on limited and artificial environment and its operation is greatly limited in having to provide an environment in which the students can spontaneously experience role play in an artificial space set in a small-scale English village consisting of shopping, restaurant, and hospital zones. The purpose of this study is to analyze the problems of the environmental restrictions in educational methodology utilizing offline English zone programs. Moreover, based on the ubiquitous concept. It is to provide a strategy for utilizing online English zone programs which utilize multimedia tools, wireless internet, and SNS.

Vegetational History of the Mulyeongari Fen by Pollen Analysis in Jeju Island, Korea (제주도 물영아리늪 퇴적물의 화분분석에 의한 식생변천)

  • Lee, Chang-Su;Kang, Sang-Joon;Choi, Kee-Ryong
    • Journal of Environmental Science International
    • /
    • v.20 no.3
    • /
    • pp.341-350
    • /
    • 2011
  • For the reconstruction of the past vegetational changes in Jeju Island, Korea, pollen analysis and radiocarbon dating on the sediments obtained from the Mulyeongari fen were carried out. By the results, the vegetational changes around the Mulyeongari fen from ca. 3,300 cal. yr BP to the present can be interpreted and reconstructed. The pollen record from the Mulyeongari fen was divided into two local pollen assemblage zones and three sub-pollen assemblage zones. Zone I (Quercus-Carpinus-Herbs Zone) was characterized by the predominance of Quercus(30~63%), Carpinus(9~35%) and herbs(40~424%). Zone II was characterized by three sub-pollen assemblage zones and the high occurrence ratio of the tree layer in comparison with Zone I. In Zone IIa (Quercus-Carpinus Zone), herbs(3~161%) were drastically decreased in predominance of Quercus(28~56%) and Carpinus(14~31%). In Zone IIb (Carpinus-Quercus Zone), Carpinus(36~48%) was preferentially increased but Quercus(29~39%) was slightly decreased. In Zone IIc (Quercus-Carpinus Zone), Carpinus(26~38%) was decreased inversely but Quercus(36~50%) was increased. In addition, Cyperaceae was also increased to 52%. Consequently, it is suggested that cool temperate southern/sub-montane vegetation composed of Quercus and Carpinus which was physiognomy of deciduous broad leaved forest was distributed around the Mulyeongari fen from ca. 3,300 cal. yr BP. In addition, Cyclobalanopsis(4~23%), Castanopsis(1~12%) and Myrica(under 1%) which are warm-temperate evergreen deciduous forest components were constantly appeared from this period. Accordingly, it can be inferred that the present vegetation type around the Mulyeongari fen was formed from ca. 180 cal. yr BP.

A multi-phase model for predicting the effective chloride migration coefficient of ITZ in cement-based materials

  • Yang, C.C.;Weng, S.H.
    • Advances in concrete construction
    • /
    • v.1 no.3
    • /
    • pp.239-252
    • /
    • 2013
  • Mortar microstructure is considered as a three-phase composite material, which is cement paste, fine aggregate and interfacial transition zone. Interfacial transition zone is the weakest link between the cement paste and fine aggregate, so it has a significant role to determine the properties of cementitious composites. In this study, specimens (w/c = 0.35, 0.45, 0.55) with various volume fractions of fine aggregate ($V_f$ = 0, 0.1, 0.2, 0.3 and 0.4) were cast and tested. To predict the equivalent migration coefficient ($M_e$) and migration coefficient of interfacial transition zone ($M_{itz}$), double-inclusion method and Mori-Tanaka theory were used to estimate. There are two stages to estimate and calculate the thickness of interfacial transition zone (h) and migration coefficient of interfacial transition zone ($M_{itz}$). The first stage, the data of experimental chloride ion migration coefficient ($M_s$) was used to calculate the equivalent migration coefficient of fine aggregate with interfacial transition zone ($M_e$) by Mori-Tanaka theory. The second stage, the thickness of interfacial transition zone (h) and migration coefficient of interfacial transition zone ($M_{itz}$) was calculated by Hori and Nemat-Nasser's double inclusion model. Between the theoretical and experimental data a comparison was conducted to investigate the behavior of interfacial transition zone in mortar and the effect of interfacial transition zone on the chloride migration coefficient, the results indicated that the numerical simulations is derived to the $M_{itz}/M_m$ ratio is 2.11~8.28. Additionally, thickness of interfacial transition zone is predicted from $10{\mu}m$, 60 to $80{\mu}m$, 70 to $100{\mu}m$ and 90 to $130{\mu}m$ for SM30, M35, M45 and M55, respectively.

Inter-GuestOS Communications in Multicore-based ARM TrustZone (멀티코어 프로세서 기반 ARM TrustZone 환경에서의 게스트 운영체제 간 통신)

  • Jeon, Moowoong;Kim, Sewon;Yoo, Hyuck
    • Journal of KIISE
    • /
    • v.42 no.5
    • /
    • pp.551-557
    • /
    • 2015
  • The technology using ARM TrustZone draws attention as a new embedded virtualization approach. The ARM TrustZone defines two virtual execution environment, the secure world and the normal world. In such an environment, the inter-world communication is important to extend function of software. However, the current monitor software does not sufficiently support the inter-world communication. This paper presents a new inter guestOS communication scheme, for each world, for the ARM TrustZone virtualization. The proposed communication scheme supports bidirectional inter-world communication for single core and multicore environment. In this paper, It is implemented on a NVIDIA Tegra3 processor based on the ARM Cortex-A9 MPCore and it showed a bandwidth of 30MB/s.

Groundwater Flow Modeling and Suggestion for Pumping Rate Restriction around K-1 Oil Stockpiling Base with Geological Consideration (지질조건을 고려한 K-1 비축기지 주변의 지하수 모델링과 양수량 제한구역 제안)

  • Moon, Sang-Ho;Kim, Kue-Young;Ha, Kyoo-Chul;Kim, Young-Seog;Won, Chong-Ho;Lee, Jin-Yong
    • The Journal of Engineering Geology
    • /
    • v.20 no.2
    • /
    • pp.169-181
    • /
    • 2010
  • This study aimed at simulating several responses to stresses caused by the ground water level variations around the K-1 oil stockpile. For this simulation, we considered the characteristic hydrogeological condition including the special occurrence of long and thick acidic dyke, which is regarded as the main geological structure dominating the ground water flow system at this study area. We activated twenty-four imaginary wells which are located in northern and southern area around central K-1 site. Each neighboring distance is altogether 300 m and whole distance between K-1 site and remote wells is 1,200 m. Through the modeling, we operated the long-term and continuous pumping tests and finally categorized five zones based on maximum pumping rates for the imaginary wells; zone I within 300 meter distance from K-1 site with a pumping rate of 50 $m^3/day$; zone II between 300 to 600 meter distance from K-1 site with a pumping rate of 75 $m^3/day$; zone III between 600 to 900 meter distance from K-1 site with 150 $m^3/day$; zone IV between 900 to 1,200 meter distance from K-1 site with 300 $m^3/day$; and zone V of acidic dyke area. At zone V, especially because of their possibility of high transmissivity for groundwater flow, it is necessary to control and restrict groundwater discharge.

Performance Analysis of Women's Field Hockey Using GPS (GPS를 활용한 여자 필드하키 경기력 분석)

  • Kim, Ji-Eung;Song, Joo-Ho;Park, Jong-Chul;Choi, Eun-Young
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.461-468
    • /
    • 2019
  • The aim of this study was to compare and analyse the national players between the winning games and the losing ones by classifying the GPS data measured in the competition. 27 players of Korean national team on field hockey had analysed to collect plenty of data by using GPS system in real time on 16 A-matches for this paper. The result was followed: First, it has revealed that the winning games showed that it had played a lot in the rest of the zone except for zone 1 and zone 5 from zone 1 to zone 6. Second, is has also shown that it had a significant differences into the distance between the winning games and the losing ones. Third, there were no significant differences between Low-speed zone (zone 1 to Zone 3) and High-speed zone (zone 4 to zone 6) into the distance but were a significant differences on the number of high-accelerations in a section of accelerations. Last, in the position-specific, it has shown a significant differences between a distance by the section and the acceleration frequency and the results showed that the difference between the low accelerations and high ones influenced positively related to the performance.

Microstructure Analysis of Large Turbine Generator Stator Insulations (대형 터빈발전기 고정자 권선의 미세구조 분석)

  • Kim, Hee-Dong;Ju, Young-Ho;Song, Seong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1452-1454
    • /
    • 2002
  • Large turbine generator(rated 22kV) has failed in the stator winding area during normal operation. The capacitance and tan${\delta}$ were measured by Schering bridge in the zone 1, 2 and zone 3-6 stator windings. The capacitance and tan${\delta}$ in the zone 1, 2 of stator winding were higher than those of zone 3-6 in the stator winding. Experiments on microstructure property were conducted in the zone 1, 2 and zone 3-6 insulations, which were drawn out from stator windings of the large turbine generator. Microstructure analysis was characterized using scanning electron microscope(SEM). SEM results indicated that several isolated delaminations occurred at the interface of mica/epoxy insulations. Both thermal and mechanical aging cause the delamination.

  • PDF

The Effects of Start Block and Arc Length on Melt Through and Unmelted Zone at Welding Start in High Speed Plasma Arc Welding of Thin Plate (박판 고속 플라즈마 맞대기 용접에서 용접 시작부의 용락과 미용융에 미치는 시작블록과 아크길이의 영향)

  • Chu, Yong-Su;Hong, Seong-Joon;Jung, Jae-Pil;Cho, Sang-Myung
    • Journal of Welding and Joining
    • /
    • v.26 no.2
    • /
    • pp.92-97
    • /
    • 2008
  • In welding of thin plate, some defects such as melt through and unmelted zone occur easily at welding start, however there is a limited study on those problems. Therefore the effects of start block and arc length on melt through and unmelted zone at start were investigated in this study. When start block height was lower than base metal, there was melt through at start. And when the height was even with base metal, no unmelted zone existed. Unmelted zone was increased as start block height increased from 0mm to 0.5mm. However unmelted zone was not much changed as the height increasing from 0.5mm to 1.0mm. When gap existed between start block and base metal, melt through occurred. However, unmelted zone was increased as the contact force of start block on base metal was increased from 0kgf to 7.5kgf. And when arc length was decreased from 3.8mm to 3.0mm, unmelted zone was decreased. It was concluded that the optimum condition to prevent melt through and to minimize unmelted zone would be with start block height 0.25mm, contact force 3.0kgf, and arc length 3.4mm. This optimum condition was applied to the mass production line and resulted in satisfied outcome.

Characteristics Comparison of Prepared Films According to Influence of Adsorption Inhibitor in the Condition of Deposition (PVD증착용 흡착인히비터의 영향에 따른 제작막의 특성 비교)

  • 이찬식;윤용섭;권식철;김기준;이명훈
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.67-67
    • /
    • 2001
  • The structure zone model has been used to provide an overview of the relationship between the microstructure of the films deposited by PVD and the most prominent deposition condition.s. B.AMovchan and AV.Demchishin have proposed it firstls such model. They concluded that the general features of the resulting structures could be correlated into three zones depending on $T/T_m$. Here T m is the melting point of the coating material and T is the substrate temperature in kelvines. Zone 1 ($T/Tm_) is dominated by tapered macrograins with domed tops, zone 2 ($O.3) by columnar grains with denser boundaries and zone 3 ($T/T_m>O.5$) by equiaxed grains formed by recrystallization. J.AThomton has extended this model to include the effect of the sputtering gas pressure and found a fourth zone termed zone T(transition zone) consisting of a dense array of poorly defined fibrous grains. R.Messier found that the zone I-T boundary (fourth zone of Thorton) varies in a fashion similar to the film bias potential as a function of gas pressure. However, there has not nearly enough model for explaining the change in morphology with crystal orientation of the films. The structure zone model only provide an information about the morphology of the deposited film. In general, the nucleation and growth mechanism for granular and fine structure of the deposited films are very complex in an PVD technique because the morphology and orientation depend not only on the substrate temperature but also on the energy of deposition of the atoms or ions, the kinetic mechanism between metal atoms and argon or nitrogen gas, and even on the presence of impurities. In order to clarify these relationship, AI and Mg thin films were prepared on SPCC steel substrates by PVD techniques. The influence of gas pressures and bias voltages on their crystal orientation and morphology of the prepared films were investigated by SEM and XRD, respectively. And the effect of crystal orientation and morphology of the prepared films on corrosion resistance was estimated by measuring polarization curves in 3% NaCI solution.

  • PDF

Relationship between Adaptation Luminance and Threshold Zone Luminance for Vehicular Traffic Tunnels (터널 순응휘도와 경계부 휘도의 관계 연구)

  • Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.85-99
    • /
    • 2014
  • PURPOSES : This study has been performed with the objective to determine threshold zone luminance of adaptation luminance by target safety level in a vehicular traffic tunnel with design speed set at 100km/h. METHODS : The study made a miniature capable of portraying changes in luminance distribution within $2{\times}10^{\circ}$ conical field of view of the driver approaching to the tunnel for the test. Test conditions were set based on justifications for CIE 88-1990's threshold zone luminance used as a reference by domestic tunnel light standards (KS C 3703 : 2010). Luminance contrast of object background and object is 23%, object presentation duration is 0.5 seconds, and size of the object background is $7.3{\times}11.5m^2$ RESULTS : Threshold zone luminance was set within adaptation luminance of $100{\sim}3,000cd/m^2$. Adaptation luminance and threshold zone luminance based on 50%, 75% and 90% target safety level all showed a relatively high linear relationship. According to findings in the study, it is not appropriate to specify the relationship between adaptation luminance and threshold zone luminance as luminance ratio. Rather, direct utilization of the linear relationship gained from the study findings appears to be the better solution. CONCLUSIONS : Findings of this study may be used to determine operation of threshold zone luminance based on target safety level. However, a proper verification and validity of test results are required. Furthermore, a study to determine proper threshold zone luminance level considering target safety level reviewed in this study and various decision-making factors such as economic conditions in Korea and energy-related policies should be carried out in addition. Additional tests on adaptation luminance greater than $3,000cd/m^2$ will be performed, through which application scope of the test findings will be broadened.