• Title/Summary/Keyword: Zone 1a

Search Result 5,426, Processing Time 0.033 seconds

A Study on Distinguishing between Parent material and Weld ECT Signal at Seal Weld Zone for Steam Generator Tubing (증기발생기 전열관 밀봉용접부에서의 모재와 용접부 ECT 신호 구분에 관한 연구)

  • Cheon, Keun-Young;Shin, Ki-Seok;Nam, Min-Woo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.25-32
    • /
    • 2015
  • Many crack flaws have been detected at tubing seal weld zone in Steam Generator with Alloy600 material tubes. it is very difficult to discriminate the signal from parent material and that from weld zone because weld zone gives complicated ECT signal due to manufacturing processes. ECT signal analysis in the seal weld zone is very important since the tubes with crack in this area shall be out of service by plugging. The purpose of this paper is to distinguish between Parent material and Weld Zone ECT signal in the seal weld zone through the demonstration test of Steam Generator seal weld mock-up.

Effect of Green Buffer Zone in Reducing Gaseous Air Pollutants in the Shiwha Industrial Area (시화공단 완충녹지대의 대기오염물질 저감 효과 분석)

  • Song Young-Bae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.6 s.113
    • /
    • pp.90-97
    • /
    • 2006
  • The effects of a green buffer zone to protect a residential area from air pollution from industrial facilities and traffic was examined by analyzing the case of a green buffer zone in the Shiwha industrial complex. The green buffer zone is 175 m wide. The intent was to assess the dispersion patterns of atmospheric air pollutants and the reduction in concentration around the green buffer zone. To measure atmospheric sulfur dioxide$(SO_2)$ and nitrogen dioxide$(NO_2)$ concentration, badge-type passive samplers were used and set up at 76 locations in order to measure the concentration of air pollutants with respect to the spatial dispersion. The weighted mean values of $SO_2\;and\;NO_2$ concentration were $3\~57 ppb\;and\;18\~62 ppb$ and the differences among the green buffer zone, the industrial area and the residential areas were $0.7\~1.1 ppb$. Mean values of atmospheric concentrations of $NO_2$ were similar in industrial and, residential areas and the green buffer zone. Results of the study show that the effect of the green buffer zone on reducing the dispersion of air pollutants was very low. This study also recommends that micro-climate, i.e., wind direction should be considered as a factor for planning and design of green buffer zones.

Loop Suture Technique for Flexor Digitorum Profundus Tendon Repair in the Insertion Site (고리 봉합법을 이용한 심부 수지 굴건 종지부에서의 건봉합)

  • Lee, Kyu-Cheol;Lee, Dong-Chul;Kim, Jin-Soo;Ki, Sae-Hwi;Roh, Si-Young;Yang, Jae-Won
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.650-658
    • /
    • 2010
  • Purpose: In the case of repair for far distal parts of FDP (Flexor digitorum profundus) division, the method of either pull-out suture or fixation of tendon to the distal phalanx is preferred. In this paper, the results of a modified loop suture technique used for the complete division of FDP from both zone 1a and distal parts of zone 1b in Moiemen classification are presented. Methods: From July 2006 to July 2009, the modified loop suture technique was used for the 10 cases of FDP in complete division from zone 1a and distal parts of zone 1b, especially where insertion sites were less than 1 cm apart from a tendon of a stump. In a suture technique, a loop is applied to each distal and proximal parts of tendon respectively. Core suture of 2-strand and epitendinous suture are done with PDS 4-0. Out of 10 patients, the study was done on 6 patients who were available for the followup. The average age of the patients was 49.1 years (in the range from 26 to 67). 5 males and 1 female patients were involved in this study. There were 3 cases with zone 1a and distal parts of zone 1b. The average distance to the distal tendon end was 0.6 cm. There were 5 cases underwent microsurgical repair where both artery and nerve divided. One case of only tendon displacement was presented. The dorsal protective splint was kept for 5 weeks on average. The results of the following tests were measured: active & passive range of motion, grip strength test, key pinch and pulp pinch test. Results: The follow-up period on average was 11 months, in the range from 2 to 20 months. There was no case of re-rupture, but tenolysis was performed in 1 cases. In all 6 cases, the average active range of motion of distal interphalangeal joint was 50.8 degree. The grip strength (ipsilateral/contralateral) was measured as 88.7% and the pulp pinch test was 79.2% as those of contralateral side. Flexion contracture was presented in 2 cases (15 degree on average) and there was no quadrigia effect found. Conclusion: Despite short length of tendon from the insertion site in FDS rupture in zone 1a and distal parts of zone 1b, sufficient functional recovery could be expected with the tendon to tendon repair using the modified loop suture technique.

Simulation of an X-ray Fresnel Zone Plate with Nonideal Factors

  • Chen, Jie;Fan, Quanping;Wang, Junhua;Yuan, Dengpeng;Wei, Lai;Zhang, Qiangqiang;Liao, Junsheng;Xu, Min
    • Current Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.9-15
    • /
    • 2020
  • Fresnel zone plates have been widely used in many applications, such as x-ray telescopes, microfluorescence, and microimaging. To obtain an x-ray Fresnel zone plate, many fabrication methods, such as electron-beam etching, ion-beam etching and chemical etching, have been developed. Fresnel zone plates fabricated by these methods will inevitably lead to some nonideal factors, which have an impact on the focusing characteristics of the zone plate. In this paper, the influences of these nonideal factors on the focusing characteristics of the zone plate are studied systematically, by numerical simulations based on scalar diffraction theory. The influence of the thickness of a Fresnel zone plate on the absolute focusing efficiency is calculated for a given incident x-ray's wavelength. The diffraction efficiency and size of the focal spot are calculated for different incline angles of the groove. The simulations of zone plates without struts, with regular struts, and with random struts are carried out, to study the effects of struts on the focusing characteristics of a zone plate. When a Fresnel zone plate is used to focus an ultrashort x-ray pulse, the effect of zone-plate structure on the final pulse duration is also discussed.

A Study on the Attention Concentration Properties in Convergent Exploration Situations in Cafe Space - Focusing on Gaze and Brain wave Data Analysis - (카페공간에 대한 수렴적 탐색상황에서의 주의집중 특성의 분석 방법에 관한 연구 - 선택적 주시데이터에 의한 뇌파 데이터 분석을 중심으로 -)

  • Kim, Jong-Ha;Kim, Ju-Yeon;Kim, Sang-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.2
    • /
    • pp.30-40
    • /
    • 2016
  • This study analyzed the attention concentration tendencies of one(1) subject who showed convergent exploratory acts actively through the gaze-brainwave measurement experiment of cafe space images and our research findings are as follows. First, the areas of interest (AOIs) that the subject gazed visually by paying attention to it and concentrating on it at a cafe space include counter&menu area, sign area, partition area, image wall area, stairs area, and movable furniture area, and built-in furniture area: seven areas in total. Second, conscious gaze frequency appeared the highest in counter&menu area, and conscious gaze appeared more later than in initial times. Third, conscious gaze pattern was divided into the zone that explored various areas dispersely (distributed exploratory zone) and the zone that explored between particular areas concentratedly (intensive exploratory zone). Fourth, as a result of analyzing the brainwave attention concentration, it was found that the attention concentration in prefrontal lobe (Fp1, Fp2) and frontal lobe (F3, F4) rose to a higher level in the zone of 15 to 16 seconds and this time zone was considered to be a zone where gazing at counter&menu area was very active. In addition, the attention concentration appeared higher in the initial zone than in the later zone, among the entire experimental time zones. Finally, as a result of analyzing the changes in activation by brain portion of the SMR wave expressed when maintaining the arousal and attention concentration, it was found that the right prefrontal lobe and the frontal lobe became activated in the time zone when the intensive exploration of "counter&menu area" and "movable furniture${\leftrightarrow}$built-in furniture area" had occurred and the time zone when the intensive exploration of "image wall${\leftrightarrow}$partition area" and "counter&menu${\leftrightarrow}$sign area" had occurred.

Geology and Mineralization in Constancia Porphyry Cu-Mo Mine, Cusco State, Southeastern Peru (페루 남동부 쿠스코주 콘스탄시아 반암동-몰리브데늄 광산의 지질 및 광화작용)

  • Yang, Seok-Jun;Heo, Chul-ho
    • Economic and Environmental Geology
    • /
    • v.49 no.3
    • /
    • pp.193-199
    • /
    • 2016
  • Constancia mine is a deposit developed within Andahuaylas-Yauri Cu-Mo-Au metallogenic belt, southeastern Peru and is located in the southwestern part of Abancay deformation zone structurally as the porphyry copper deposit type. Mineralized zone in Constancia mine are composed of leached zone, secondary enrichment zone(ca. 1% Cu), mixed zone, primary mineralized zone(ca. 0.5%), skarn zone(ca. 1.5% Cu) from the upper part. Main country rock is monzonitic porphyry. Leached zone are characterized by the precipitation of limonite and looks brown in the outcrop. Oxidized zone have green due to the occurrence of copper oxide and secondary enrichment zone are characterized by the occurrence of chalcocite. Skarn zone are characterized by the occurrence of magnetite and garnet. Now, Hudbay, Canadian mining company, have 100% share about Constancia mine and started to produce commercially from January, 2015.

Agroclimatic Zone and Characters of the Area Subject to Climatic Disaster in Korea (농업 기후 지대 구분과 기상 재해 특성)

  • 최돈향;윤성호
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.s02
    • /
    • pp.13-33
    • /
    • 1989
  • Agroclimate should be analyzed and evaluated accurately to make better use of available chimatic resources for the establishment of optimum cropping systems. Introducing of appropriate cultivars and their cultivation techniques into classified agroclimatic zone could contribute to the stability and costs of crop production. To classify the agroclimatic zones, such climatic factors as temperature, precipitation, sunshine, humidity and wind were considered as major influencing factors on the crop growth and yield. For the classification of rice agroclimatic zones, precipitation and drought index during transplanting time, the first occurrence of effective growth temperature (above 15$^{\circ}C$) and its duration, the probability of low temperature occurrence, variation in temperature and sunshine hours, and climatic productivity index were used in the analysis. The agroclimatic zones for rice crop were classified into 19 zones as follows; (1) Taebaek Alpine Zone, (2) Taebaek Semi-Alpine Zone, (3) Sobaek Mountainous Zone, (4) Noryeong Sobaek Mountainous Zone, (5) Yeongnam Inland Mountainous Zone, (6) Northern Central Inland Zone, (7) Central Inland Zone, (8) Western Soebaek Inland Zone, (9) Noryeong Eastern and Western Inland Zone, (10) Honam Inland Zone, (ll) Yeongnam Basin Zone, (12) Yeongnam Inland Zone, (13) Western Central Plain Zone, (14) Southern Charyeong Plain Zone, (15) South Western Coastal Zone, (16) Southern Coastal Zone, (17) Northern Eastern Coastal Zone, (18) Central Eastern Coastal Zone, and (19) South Eastern Coastal Zone. The classification of agroclimatic zones for cropping systems was based on the rice agroclimatic zones considering zonal climatic factors for both summer and winter crops and traditional cropping systems. The agroclimatic zones were identified for cropping systems as follows: (I) Alpine Zone, (II) Mountainous Zone, (III) Central Northern Inland Zone, (IV) Central Northern West Coastal Zone, (V) Cental Southern West Coastal Zone, (VI) Gyeongbuk Inland Zone, (VII) Southern Inland Zone, (VIII) Southern Coastal Zone, and (IX) Eastern Coastal Zone. The agroclimatic zonal characteristics of climatic disasters under rice cultivation were identified: as frequent drought zones of (11) Yeongnam Basin Zone, (17) North Eastern Coastal Zone with the frequency of low temperature occurrence below 13$^{\circ}C$ at root setting stage above 9.1%, and (2) Taebaek Semi-Alpine Zone with cold injury during reproductive stages, as the thphoon and intensive precipitation zones of (10) Hanam Inland Zone, (15) Southern West Coastal Zone, (16) Southern Coastal Zone with more than 4 times of damage in a year and with typhoon path and heavy precipitation intensity concerned. Especially the three east coastal zones, (17), (18), and (19), were subjected to wind and flood damages 2 to 3 times a year as well as subjected to drought and cold temperature injury.

  • PDF

The CO2 Reduction Potential Calculation through the Urban Park Construction

  • Lee, Eun Yeob;Kang, Myung Soo;Kim, Jong Kon
    • KIEAE Journal
    • /
    • v.14 no.2
    • /
    • pp.87-98
    • /
    • 2014
  • This study is to identify quantitatively the function of carbon dioxide emissions reduction due to temperature and energy reduction according to direct carbon dioxide storage, shade provision, and evaportanspiration of urban park. According to the result of study, landscape tree indicated high carbon dioxide storage effect compare to bush, in which broadleaf tree indicated higher storage function than coniferous tree. It is believed to be the storage of carbon dioxide can be increased by increasing the composition rate of forest plants in the urban park. According to the direct estimation result of carbon dioxide storage in terms of example area, storage of carbon dioxide is estimated to be "seoul a zone" $476,818.8kg{\cdot}CO_2/m^2yr$, "anyang b zone" $186,435.7{\cdot}CO_2/m^2yr$, "daejeon c zone" $262,826{\cdot}CO_2/m^2yr$, "kwangju d zone" $231,657.8{\cdot}CO_2/m^2yr$. The carbon dioxide storage per unit area estimated to be "seoul a zone" $3.4{\cdot}CO_2/m^2yr$, "anyang b zone" $5.0{\cdot}CO_2/m^2yr$, "daejeon c zone" $2.6{\cdot}CO_2/m^2yr$, "kwangju d zone" $5.6{\cdot}CO_2/m^2yr$. The result of indirect carbon dioxide reduction effect estimated to be "seoul a zone" $291,603.4{\cdot}CO_2/m^2yr$, "anyang b zone" $165,462.4{\cdot}CO_2/m^2yr$, "daejeon c zone" $141,719.2{\cdot}CO_2/m^2yr$, "kwangju d zone" $154,803.4{\cdot}CO_2/m^2yr$. Carbon dioxide reduction potential amount through the urban park was increased to 1.6 times to 1.8 times when calculated to the indirect effect.

The Evaluation of Historical and Cultural Authenticity of the Three Major Cultural Areas Projects - Targeting Korean culture theme park in Yeongju-Zone and World confucian scholar culture park in Bonghwa-Zone - (3대문화권 사업 계획의 역사문화적 진정성 평가 - 한국문화테마파크 영주지구와 세계유교선비문화공원 봉화지구를 대상으로 -)

  • Jung, Kyoung-Ah;So, Hyun-Su
    • Journal of Korean Society of Rural Planning
    • /
    • v.22 no.1
    • /
    • pp.25-35
    • /
    • 2016
  • This study targets Korean culture theme park in Yeongju-Zone and World confucian scholar culture park in Bonghwa-Zone among the Three Major Cultural Areas Projects supervised by Ministry of Culture, Sports and Tourism. The study analyzes the Historical and Cultural Authenticity of each project on the basis of the reports and the report materials for meeting with related organizations. The results of the study are drawn as follows. First, through the theoretical consideration, this study drew the types of authenticity: originality, identity, specificity and visibility, which are evaluation items on the Historical and Cultural Authenticity. Second, Bonghwa-Zone succeeded in acquiring originality with tangible cultural properties but Yeongju-Zone chose a project site without it. Third, with originality, Bonghwa-zone was evaluated as having resources and concept with high traditional culture connectivity and fulfilled identity. It led the feature showing the high affinity between originality and identity. Fourth, compared to the projects of Andong-Zone in the Three Major Cultural Areas Projects, these two projects failed to acquire the distinctions since the primary and the secondary influence area and major facilities & programs coincided with those of the projects of Andong-Zone. Fifth, compared to Bonghwa-Zone, Yeongju-Zone realized visibility faithfully by the conceptual flexibility of "Korean Culture" and a large-scale development. Sixth, in terms of the Historical and Cultural Authenticity of project plan, it is evaluated that Yeongju-Zone and Bonghwa-Zone only fulfilled visibility and specificity respectively.

The Association of AUDIT Levels with Obesity Indices, Liver Function Tests, and Serum Lipid Levels in Male Health Checkup Examinees (건강검진 남성 수검자들의 알코올장애선별검사(AUDIT) 수준과 비만지표, 간기능검사치 및 혈청지질치와의 관련성)

  • Kim, Seok-Ju;Cho, Young-Chae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3230-3242
    • /
    • 2015
  • In this study, in an attempt to elucidate the relevance and the association between AUDIT level and health related indices such as obesity-related indices (BMI, waist circumference, body fat percentage), serum liver-enzyme levels (AST, ALT, GGT, total bilirubin) and serum lipid levels (TC, TG, HDL-C, LDL-C), data about including results of health checkup examination and questionnaire from 558 male examinees of 30-79 years old, who received a comprehensive health examination in the health promotion center of a university hospital during the period of January 1 to December 31, 2012, was analysed. As a results, the distribution of AUDIT rating of subjects was Zone I 58.2%, Zone II 25.3%, Zone III 7.0%, and Zone IV 9.5%. And AUDIT levels have significant relevance with age, smoking, body fat, GGT and TG. Especially, for the waist circumference, GGT and TG, the odds ratio indicating abnormality significantly increased in the higher AUDIT groups (Zone II~Zone IV) than a low-grade group (Zone I). This suggests that drinking problem with a high AUDIT level has a significant relevance with an abnormal increase of indices for obesity, serum liver-enzyme levels, serum lipid levels.