• Title/Summary/Keyword: Zirconia Ceramic

Search Result 628, Processing Time 0.022 seconds

Functional and esthetical full mouth rehabilitation with implant supported prostheses: A case report (고정성 임플란트 보철물을 이용한 완전구강회복 증례)

  • Yeon, Jae-Woong;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.81-85
    • /
    • 2015
  • This report describes the prosthetic treatment of a patient with multiple missing teeth. Installation of five fixtures on maxilla with sinus lift and six fixtures on mandible with ramal bone graft were performed. With implant supported all-ceramic with zirconia core using CAD/CAM technology and porcelain-fused-to-gold prosthesis, treatment with positive outcome which satisfies both functional and esthetical aspect was obtained.

Wear Of Resin Composites Polymerized By Conventional Halogen Light Curing And Light Emitting Diodes Curing Units (HALOGEN LIGHT CURING UNIT 과 LIGHT EMITTING DIODES CURING UNIT 을 이용하여 중합되어진 복합레진의 마모 특성 비교)

  • 이권용;김환;박성호;정일영;전승범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1057-1060
    • /
    • 2004
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion with sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed the least wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as a curing unit for composite resin restorations.

  • PDF

Oxygen Permeability, Electronic and ionic Conductivities and Defect Chemistry of Ceria-Zirconia-Calcia

  • Kawamura, Ken-ichi;Watanabe, Kensuke;Nigara, Yutaka;Kaimai, Atsushi;Kawada, Tatsuya;Mizusaki, Junichiro
    • The Korean Journal of Ceramics
    • /
    • v.4 no.2
    • /
    • pp.146-150
    • /
    • 1998
  • The total conductivity and oxygen permeation in (Ce1-xZrxO2)0.9(CaO)0.1 solid solutions were measure das a function of temperature and oxygen partial pressure. Empirically, σ at given x and T was expressed essentially by σ=σo2+σeo Po2-1/4, where σo2 and σeo are constant. Applying a standard defect model in which major defects are Cace", Cece' and Vo in ideal solution, we can assign σo2 as the oxide ion conductivity decreases while the electronic conductivity increases with the increase in Zr content. Using the oxide ion and electronic conductivities thus determined, the oxygen permeation flux was calculated for respective Po2 and T conditions at which the measurements were made. The calculated values were found to agree with the observed ones.

  • PDF

Characterization of Fracture Toughness and Wear Behavior for Plasma Ceramic Coated Materials (플라즈마 코팅재료의 파괴인성과 마모 거동)

  • Ha, Sun-Ho;Lee, Dong-Woo;Rehman, Atta Ur;Wasy, Abdul;Song, Jung-Il
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.123-130
    • /
    • 2013
  • Zirconia is well known in industrial applications for its mechanical characteristics. DLC (diamond-like carbon) have high elastic modulus, high electric resistivity, high dielectric constant, high wear resistance, low friction coefficient, bio compatibility, chemically inert and thermally stable. Because of all these physical and chemical properties these types of coatings have become key procedure for thin coating. Friction coefficient of DLC films is already evaluated and the current work is a further advancement by calculating the fracture toughness and wear resistance of these coatings. In the present study DLC thin film coatings are developed on $ZrO_2$ alloy surface using Plasma Enhanced Chemical Vapor Deposition (PECVD) method. Vicker hardness test is employed and it was concluded that, DLC coatings increase the Vickers hardness of ceramics.

Fabrication of Polymeric Optical Fiber Array (정밀 고분자 광섬유 어레이 제작 연구)

  • Cho, Sang-Uk;Jeong, Myung-Yung;Kim, Chang-Seok;Ahn, Seung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.5
    • /
    • pp.82-88
    • /
    • 2007
  • This work is to fabricate a precise optical fiber array using polymer composite for optical interconnection. Optical fiber array has to satisfy low optical loss requirement less than 0.4 dB according to temperature change. For this purpose, design criteria for an optical fiber array was derived. The coefficient of thermal expansion of silica particulate epoxy composites was affected by volume fraction of silica particles. And also, elastic modulus of silica particulate epoxy composites was affected by volume fraction of silica particles. To obtain the coefficients of thermal expansion below $10{\times}10E-6/^{\circ}C$ and elastic modulus more than 20 GPa , we chose the volume fraction more than 76%. Using silica particulate epoxy composites with the volume fraction 76%, 8-channel optical fiber array with dimensional tolerances below $1\;{\mu}m$ was manufactured by transfer molding technique using dies with the uniquely-designed core pin and precisely-machined zirconia ceramic V block. These optical fiber arrays showed optical loss variations within 0.4 dB under thermal cycling test and high temperature test.

INDUCTION PLASMA DEPOSITION TECHNOLOGY FOR NUCLEAR FUEL FABRICATION

  • I. H. Jung;K. K. Bae;Lee, J. W.;Kim, T. K.;M. S. Yang
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.216-221
    • /
    • 1998
  • A study on induction plasma deposition with ceramic materials, yttria-stabilized-zirconia ZrO$_2$-Y$_2$O$_3$ (m.p 264O $^{\circ}C$), was conducted with a view developing a new method for nuclear fuel fabrication Before making dense pellets more than 96%TD., the spraying condition was optimized through the process parameters, such as chamber pressure, plasma plate power powder spraying distance, sheath gas composition, probe position, particle size and powders different morphology. The results with a 5mm thick deposit on rectangular planar graphite substrates showed a 97.11% theoretical density when the sheath gas flow rate was Ar/H$_2$120/20 l/min, probe position 8cm, particle size -75 ${\mu}{\textrm}{m}$ and spraying distance 22cm by AMDRY146 powder. The degree of influence of the main effects on density were powder morphology. particle size, sheath gas composition, plate power and spraying distance, in that order. Among the two parameter interactions, the sheath gas composition and chamber pressure affects density greatly. By using the multi-pellets mold wheel type, the pellet density did not exceed 94%T.D., owing to the spraying angle.

  • PDF

Fabrication of 8YSZ-$Al_2O_3$ solid oxide full cell (SOFC) electrolyte by a spark plasma sintering method (방전 플라즈마 소결법을 이용한 8YSZ-$Al_2O_3$ 고체 산화물 연료전지 전해질 제조)

  • Kim Jae Kwang;Choi Bong Geun;Yang Jae Kyo;Choa Yong Ho;Shim Kwang Bo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.15 no.1
    • /
    • pp.16-20
    • /
    • 2005
  • In order to improve electrical conductivity and mechanical properties of 8YSZ SOFC electrolyte material, we used Al₂O₃ as an additive and applied the spark plasma sintering (SPS) method. The sintered bodies were densified above 96 % of theoretical density at 1200℃ and possessed microstructures composed of homogeneous grains less than 1 ㎛ in size. The addition of Al₂O₃ improved fracture toughness and bending strength by inhibiting grain growth of 8YSZ and increased total ionic conductivity because grain interior conductivity appeared to remain constant and grain boundary conductivity increased. It was assumed that the dissolution of Al₂O₃ into 8YSZ which was inevitable problem at commercial sintering method was effectively prohibited by the SPS technique with a relatively low sintering temperature and the reaction between Al₂O₃ and SiO₂ present at grain boundary to produce the crystalline Al/sub 2-x/Si/sub l-y/O/sub 5/ phase, resulting in the increase of grain boundary conductivity.

Reestablishing the occlusal plane in full mouth rehabilitation patient, using Shilla system (전악수복환자에서 Shilla system을 이용한 교합평면 재구성 증례)

  • Yang, Min-Soo;Vang, Mong-Sook;Park, Sang-Won;Lim, Hyun-Phil;Yun, Kwi-Dug;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.33-38
    • /
    • 2013
  • Occlusal plane is a sagittal expression of dental arch form, and it composes the shape of occlusion, which is one of the most important elements of Maxillo-oral system. In this case, vertical, horizontal coordinates of bionic-median-sagittal plane was produced in articulator, and to achieve relation of left and right position of upper, lower teeth and deficits in alveola, Shilla system was used to reconstruct occlusal plane. In this case, a 41 year-old male patient visited for fracture of 10 unit metal-ceramic fixed partial denture of upper anterior teeth and for overall treatment. Clinical, radiographical, model examination was held, full mouth rehabilitation was achieved by placing dental implant. Maxillo-oral relation was recorded using Gothic arch Tracer complex and were mounted. And for the next step, we estimated original occlusal plane using Shilla system. After analysis we produced diagnosis wax pattern. On the basis of this, radiography stent was manufactured and dental implant was placed, and temporary prosthesis was made by using diagnosis wax pattern. Cross mounting and anterior guiding table were performed in order to reproduce temporary restoration morphology and bite pattern, followed by final restoration made of all ceramic crown with zirconia coping. As stated above, appropriately esthetic and functional results can be seen in using Shilla system in diagnosis and treatment procedure of full mouth rehabilitation patient.

Machining Tolerance of Various Implant Systems and their Components (치과용 임플란트 시스템의 기계적 가공오차에 관한 연구)

  • Kim, Hyeong-Seob;Kwon, Kung-Rock;Han, Jung-Suk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.57-65
    • /
    • 2008
  • Purpose: Misfit of implant components was very important in terms of prosthodontics. they has been linked to prosthetic complications such as screw loosening and fracture. Although there are many results about rotational freedom or machining tolerance between fixture and abutments, the data about domestic implant systems are lacking. The aim of this in vitro study was to evaluate the rotational freedom of domestic external and internal connection implant systems between their fixtures/anlaogs and abutments comparing imported systems. Materials and Methods: Rotational freedom between abutments and fixtures/analogs was investigated by using digitalized rotational angle measuring device. (1) 1 domestic external connection system(Neobiotec) and 2 imported external connection systems(Nobel Biocare, Anthorgyr), (2) 1 domestic internal connection system(Dentium) and 4 imported external connection systems(Nobel Biocare, Anthorgyr, Straumann, Frident Dentsply), and (3) 1 domestic zirconia external connection abutment(ZirAce) were evaluated. Each group has 3 samples. Mean values for each group were analyzed. Results: The differences relative to rotational freedom between domestic and imported implant systems were observed but domestic external connection implant system showed about 2.67 degrees(in case of fixture) and internal connection system showed about 4.3 degrees(in case of fixture). Domestic zirconia abutment showed less than 3 degrees of rotational freedom in a situation where the abutment was connected to an implant fixture egardless of domestic or imported systems. Conclusion: Newly developed digitalized rotational angle measuring device has high measuring resolution. The rotational freedom of domestic implant systems were similar to imported implant systems.

Effect of Pressing Process on the High-Temperature Stability of Yttria-Stabilized Zirconia Ceramic Material in Molten Salt of CaCl2-CaF2-CaO (CaCl2-CaF2-CaO 용융염에서 YSZ 세라믹의 고온 안정성에 미치는 성형공정의 영향)

  • Kim, Wan-Bae;Kwon, Suk-Cheol;Cho, Soo-Haeng;Lee, Jong-Hyeon
    • Korean Journal of Materials Research
    • /
    • v.30 no.4
    • /
    • pp.176-183
    • /
    • 2020
  • The high-temperature stability of YSZ specimens fabricated by die pressure and cold isostatic press (CIP) is investigated in CaCl2-CaF2-CaO molten salt at 1,150 ℃. The experimental results are as follows: green density 46.7 % and 50.9 %; sintering density 93.3 % and 99.3 % for die press and CIP, respectively. YSZ foremd by CIP exhibits higher stability than YSZ formed by die press due to denseness dependency after high-temperature stability test. YSZ shows peaks mainly attributed to CaZrO3, with a small t-ZrO2 peak, unlike the high-intensity tetragonal-ZrO2 (t-ZrO2) peak observed for the asreceived specimen. The t-ZrO2 phase of YSZ is likely stabilized by Y2O3, and the leaching of Y2O3 results in phase transformation from t-ZrO2 to m-ZrO2. CaZrO3 likely forms from the reaction between CaO and m-ZrO2. As the exposure time increases, more CaZrO3 is observed in the internal region of YSZ, which could be attributed to the inward diffusion of molten salt and outward diffusion of the stabilizer (Y2O3) through the pores. This results in greater susceptibility to phase transformation and CaZrO3 formation. To use SOM anodes for the electroreduction of various metals, YSZ stability must be improved by adjusting the high-density in the forming process.