• 제목/요약/키워드: Zirconia Ceramic

검색결과 628건 처리시간 0.02초

Sample Preparation for Microstructural Characterization of Ni-Yttria-Stabilized Zirconia Anodes

  • Sim, Soo-Man
    • 한국세라믹학회지
    • /
    • 제55권4호
    • /
    • pp.376-380
    • /
    • 2018
  • Microstructural characterization of Ni-yttria-stabilized zirconia (YSZ) anodes using secondary electron images has been limited by a lack of contrast between Ni and YSZ phases. This paper reports a sample preparation method for obtaining secondary electron images that allow the detection of Ni, YSZ, and pore phases together. Ni-YSZ anode samples were obtained by reducing NiO-YSZ samples prepared by using the mixed oxide method. Colloidal silica polishing and electrolytic etching were performed on the Ni-YSZ samples. The morphological change of the sample surface after each polishing process is examined.

지르코니아 강화형 Glass-Ceramic의 기계적 성질 (Mechanical Properties of Zirconia Reinforced Glass-Ceramic)

  • 박은의;동진근;이해형;송기창;오상천
    • 구강회복응용과학지
    • /
    • 제17권3호
    • /
    • pp.199-204
    • /
    • 2001
  • This study was to investigate the reused possibility of zirconia reinforced glass-ceramic(IPS Empress Cosmo ceramic) with sprue button in the flexure strength and fracture toughness. 40 disk-shaped ceramic specimens (20 specimens: as-pressed material; 20 specimens: reused material) with approximately 1.7 mm thickness and 15 mm diameter were prepared by "lost wax" technique. The remnants(sprue buttons) were used for repressing. The surface treatments for the discs were gradually abraded with 320, 800, 1200, and 2000 grit SiC sandpaper. The specimens were evaluated their flexure strength with the biaxial flexure jig(ball-on-three balls) and their fracture toughness with Vickers Indentation-microfracture test. The Weibull moduli were calculated for biaxial flexural strength. The mean flexure strength and fracture toughness of each group were $122.2{\pm}18.3MPa$, $1.00{\pm}0.09MPa{\cdot}m^{0.5}$ (as-pressed ceramics), and $122.2{\pm}20.3MPa$, $1.01{\pm}0.10MPa{\cdot}m^{0.5}$ (reused ceramics). There were no significant differences in the strength and the fracture toughness between the as-pressed and the reused IPS Empress Cosmo ceramic (P>0.05). This implied zirconia reinforced glass-ceramic(IPS Empress Cosmo ceramic) could be used one more time by reusing of sprue button in the flexure strength and fracture toughness.

  • PDF

Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis

  • Peter Gehrke;Maria Julia Pietruska;Johannes Ladewig;Carsten Fischer;Robert Sader;Paul Weigl
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권4호
    • /
    • pp.231-243
    • /
    • 2024
  • PURPOSE. The objective of the study was to analyze the impact of cement, bonding pretreatment, and ceramic abutment material on the overall color results of CAD-CAM ceramic crowns bonded to titanium-based hybrid abutments. MATERIALS AND METHODS. For single implant restoration of a maxillary lateral incisor a total of 51 CAD-CAM-fabricated monolithic lithium disilicate crowns were fabricated and subsequently bonded onto 24 lithium disilicate Ti-base abutments, 24 zirconia Ti-base abutments and 3 resin abutment replicas as a control group. The 48 copings were cemented with three definitive and one provisional cement on both grit-blasted and non-blasted Ti-bases. The color of each restoration and surrounding artificial gingiva was measured spectrophotometrically at predefined measuring points and the CIELAB (ΔEab) color scale values were recorded. RESULTS. The color outcome of ceramic crowns bonded to hybrid abutments and soft tissues was affected differently by cements of different brands. Grit-blasting of Ti-bases prior to cementing CAD-CAM copings affected the color results of allceramic crowns. There was a significant difference (P = .038) for the median ΔE value between blasted and non-blasted reconstructions at the cervical aspect of the crown. Full-ceramic crowns on zirconia Ti-base abutments exhibited significantly lower ΔE values below the threshold of visibility (ΔE 1.8). In all subcategories tested, the use of a highly opaque temporary cement demonstrated the lowest median ΔE for both the crown and the artificial gingiva. CONCLUSION. Various cements, core ceramic materials and airborne particle abrasion prior to bonding can adversely affect the color of Ti-base supported ceramic crowns and peri-implant soft tissue. However, zirconia CAD-CAM copings and an opaque cement can effectively mask this darkening.

Effects of colored zirconia surface treatment on the bond strength of veneering ceramics

  • Kim, SA-Hak;Kim, Chong-Kyen
    • 대한치과기공학회지
    • /
    • 제43권4호
    • /
    • pp.160-167
    • /
    • 2021
  • Purpose: In this study, when the etching treatment method, which is a chemical surface treatment method, is applied to colored zirconia, the shear bond strength between the veneering ceramic material and colored zirconia is compared with that without surface treatment, and the fracture type is observed to evaluate the etching treatment effect of colored zirconia. Methods: Experiments were conducted after dividing the study sample into two groups, which are the zirconia control group without surface treatment using colored zirconia blocks (without etching zirconia, NZC group) and the zirconia group treated with a commercially available etching solution (etching liquid zirconia, EZC group). Results: The mean shear bond strength of the NZC group was 20.31±2.32 Mpa, and that of the EZC group was 25.95±2.34 Mpa, and the difference between these two values was statistically significant (p<0.05). Further, the surface roughness Ra value was higher in the EZC group than in the NZC group. In the fracture pattern, cohesive fractures were dominant, and adhesive fractures and cohesive fractures were mixed. Conclusion: The bond strength was significantly higher in the group treated with colored zirconia. The fracture pattern was mostly cohesive failure in the group not treated with etching and changed to mixed failure as the etching treatment progressed.

심미보철 치료의 경향과 이해 : part 2. 지르코니아 (Understanding and trends of esthetic treatment in prosthodontics : part 2. Zirconia)

  • 강정인;허유리;이명선;손미경
    • 한국치위생학회지
    • /
    • 제14권5호
    • /
    • pp.617-622
    • /
    • 2014
  • With the explosive increase of esthetic demands by patients, many dental materials for the esthetic restoration have been introduced. Recently, zirconia based restorations are using for the cases of single crown, bridges, implant prostheses etc. Zirconia have superior mechanical properties and biocompatibility. Owing to the properties of high strength, zirconia has to be manufactured by CAD/CAM system. Dental CAD/CAM system is a futuristic treatment and technical system which makes it possible to produce the precision and uniform prosthesis and also standardize the treatments. This article introduces the characteristics of zirconia, fabrication procedure using CAD/CAM system and procedure for the cementation of zirconia based restoration.

지르코니아 CAD/CAM block의 강도에 관한 연구 (A study on the Flexural strength of zirconia CAD/CAM block)

  • 이정수
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.65-69
    • /
    • 2008
  • Recently, zirconia is widely used in the field of dental ceramics thanks to the proliferation of CAD/CAM systems. Accordingly, different types of zirconia block are being solid in the market. However, there are no precise, objective standards for properties of zirconia. This study concerns the flexural strength of zirconia ceramic for CAD/CAM block. The test specimens used for this study were ZirBlank(Acucera), ZirBlank shade(Acucera), VITA, Cercon(Densply) and Cerasys. The test results suggest that ZirBlank shade block shows the highest flexural strength and density among the zirconia blocks tested. Its flexural strength was $971{\pm}58MPa$ and its density was 99.89%. On the other hand, Cerasys block shows the lowest flexural strength of $576{\pm}36MPa$ and the lowest density of 94.85%. Given all, the density of the specimens is found to be directly proportional to strength and inversely to grain size.

  • PDF

플라즈마 용사법에 의한 지르코니아 코팅에서의 잔류응력에 대한 연구 (Residual stresses on plasma sprayed zirconia coatings)

  • 류지호;강춘식
    • Journal of Welding and Joining
    • /
    • 제7권4호
    • /
    • pp.46-55
    • /
    • 1989
  • Zirconia coatings are performed by the plasma spraying on the substrate of Al-Si alloy. In case of plasma sprayed ceramic coatings, it is important to control properly residual stress occurred during cooling process. Residual stress in coating layer varies with sprayed conditions and is influenced greatly by the coating layer thickness. Surface residual stress due to coating layer thickness is measured by X-ray diffraction method and the residual stress in coating layer is estimated by the deflection of coating layer when the restraint force in substrate was removed. When zirconia was coated on the substrate, tensile residual stress remains on zirconia coated surface layer. The tensile stress is increased to 0.35mm thickness and after 0.45mm thickness it is decreased abrouptly. A thick bond and composite coating reduce the zirconia surface stress and composite coating controls effectively the thick zirconia surface stress.

  • PDF

상온진공 과립분사에 의한 지르코니아 필름의 코팅거동 (Coating behavior of zirconia film fabricated by granule spray in vacuum)

  • ;강영림;박운익;박동수;박찬
    • 한국결정성장학회지
    • /
    • 제32권5호
    • /
    • pp.205-211
    • /
    • 2022
  • GSV (Granule Spray in Vacuum)는 상온의 진공하에서 나노 크기의 치밀한 세라믹 코팅층을 형성하는 방법이다. 일반적으로, 단사정의 지르코니아는 1150℃에서 정방정으로 변태하며, 이때 6.5 %의 체적변화를 일으켜 치밀한 단사정의 지르코니아를 만들기 어렵다. 본 연구에서는 코팅 효율에 대한 두 가지 처리 변수의 효과를 조사하는 데 중점을 두었다. 아울러, 특별한 가열과정 없이 형성된 필름의 미세구조에 관찰하였다. 샘플 기판에 증착된 지르코니아 필름에 대한 X-ray diffractometer (XRD) 분석은 단사정 지르코니아 필름이 성공적으로 증착되었음을 보여주었다.

지르코니아 코어의 표면처리방법이 열 가압 세라믹과의 전단결합강도에 미치는 영향 (The Influence of Surface Treatments on Shear Bond Strength between Zirconia Core and Heat Press Ceramic Interface)

  • 박항민;정인성
    • 대한치과기공학회지
    • /
    • 제31권2호
    • /
    • pp.23-30
    • /
    • 2009
  • All-ceramic restorations have gained acceptance among clinicians and patients because of their superior esthetics. Most all-ceramic systems have a 2-layer structure, using a weak veneering ceramic over a strong supporting core. often, failure of all-ceramic restorations occurs when the veneering ceramic fractures, exposing the core material. The purpose of this study was to compare the shear bond strength of heat press ceramic system (Zirpress) to zirconia core with various surface treatments. 10 metal cores and 50 zirconia cores were fabricated and divided into six groups according to surface treatment such as Zirliner application, aluminium oxide blasting, and 9.5% HF etching. Sixty specimens were prepared using Zirpress, veneered 8mm height and 3mm in diameter, over the zirconia cores (n=10). The shear bond strength test was performed in a universal testing machine with a crosshead speed of 1/min. Ultimate shear bond strength data were analyzed with One-way ANOVA and the Scheffe's test (p=.05). Within the limits of this study, the following conclusions were drawn: The mean shear bond strengths (MPa) were: 12.93 for $110{\mu}m$ aluminium oxide blasting/Rexillium III/IPS e.Max Zirpress; 14.92 for $50{\mu}m$ aluminium oxide blasting ${\pm}9.5%$ HF etching/Zirconis core/IPS e.Max Zirpress; 16.37 for $110{\mu}$ aluminium oxide blasting + 9.5% HF etching/Zirconis core/IPS e.Max Zirpress; 12.89 for $200{\mu}$ aluminium oxide blasting + 9.5% HF etching/Zirconis core/IPS e.Max Zirpress; 19.30 for 9.5% HF etching/Zirconis core/IPS e.Max Zirpress; 19.55 for Zirliner/Zirconis core/IPS e.Max Zirpress. The mean shear bond strength for ZNTZH (Zirliner/Zirconis core) and ZNTEH (9.5% HF etching/Zirconis core) were significantly superior to MS110H ($110{\mu}$ aluminium oxide blasting/Rexillium III) and ZS200EH ($200{\mu}$ aluminium oxide blasting + 9.5% HF etching/Zirconis core) (p<0.05).

  • PDF

OPTICAL CONNECTOR 용 CERAMIC FERRULE 및 SLEEVE 제조에 관한 연구 (THE STUDY ON THE MANUFACTURE CERAMIC FERRULE AND SLEEVE FOR OPTICAL CONNECTOR)

  • 조세형;강석인;손선기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 춘계학술대회 논문집
    • /
    • pp.6-10
    • /
    • 1993
  • 빛을 통신매체로 사용한 광통신은 저손실, 광대역성, 대용량화등의 장점 때문에 많은 중장거리 통신을 점유하고 있으며, 대형가입자군을 위한 광가입자망이나 LAN등에도 시험적용되고 있다. 따라서 광통신에 있어 광FIBER를 연결시키는 CERAMIC단자를 연구개발하는데 그목적을 두었으며, CERAMIC 단자의 재질로서는 구조재료로 주로 사용되는 ZIRCONIA(psz)를 선정하였으며 또한 정밀성형 및 소결등을 검토하였다.

  • PDF