• 제목/요약/키워드: Zigzag Scanning

검색결과 25건 처리시간 0.027초

Adaptive Scanning for H.264/AVC Intra Coding

  • Lee, Yung-Lyul;Han, Ki-Hun;Sim, Dong-Gyu;Seo, Jeong-Il
    • ETRI Journal
    • /
    • 제28권5호
    • /
    • pp.668-671
    • /
    • 2006
  • In this letter, an adaptive scanning that improves intra coding efficiency in the H.264/AVC standard is proposed. The proposed adaptive scanning utilizes the prediction directions (modes) that include the horizontal and vertical edge information in a block. Depending on the prediction directions, the proposed method uses three scanning methods: zigzag scanning, horizontal scanning, and vertical scanning. In the proposed method, horizontal and vertical scanning are used in vertical and horizontal prediction modes, respectively, and the normal zigzag scanning in the H.264 standard is used in all other intra prediction modes. The proposed method reduces the bit rate by approximately 2.5% compared with H.264/AVC, without the degradation of video quality.

  • PDF

Si(111)$4{\times}1$-In 표면에의 수소원자 흡착 연구 (Adsorption of H Atoms on the Si(111)$4{\times}1$-In Surface)

  • 유상용;이근섭
    • 한국진공학회지
    • /
    • 제15권2호
    • /
    • pp.139-144
    • /
    • 2006
  • Scanning tunneling microscopy (STM)를 이용하여 Si(111)$4{\times}1$-In 표면에의 수소원자 흡착의 영향을 고찰하였다. STM 이미지에서 수소원자는 $4{\times}1$-In chain의 한 쪽 줄에 있는 두개의 연속된 밝은 부분 사이에 위치한다. 이 H 원자는 두 줄의 zigzag subchain 중의 한 쪽에만 선택적으로 흡착되는 경향성을 보이며 이는 수소원자의 흡착에 표면 밑의 구조가 영향을 미침을 시사한다. 표면에 흡착된 수소원자는 흡착위치 주위의 국소적 변형 뿐 만 아니라 chain 방향으로 멀리 떨어진 곳에도 영향을 미쳐서 STM 이미지에 두 배 주기의 modulation이 나타나게 한다. 수소흡착에 의해 유도되는 두 배 주기의 modulation은 기존에 보고된 Na 원자 흡착에 의해 유도되는 상과 다름을 확인하였다.

전자빔 리소그래피를 이용한 주사기법에 따른 패턴형상 조정 (Pattern Shape Modulation by Scanning Methods in E-Beam Lithography)

  • 오세규;김승재;김동환;박근;장동영
    • 한국생산제조학회지
    • /
    • 제18권6호
    • /
    • pp.558-564
    • /
    • 2009
  • To aim at obtaining a correct and fine small pattern by an electron beam lithography several conditions and methods affecting a real pattern shape needs to be investigated. A micro/nano sized pattern shape is sometimes dependent on the scanning method. In this work, four types of scanning methods are implemented and their characteristics are investigated. For a $11\times11um$ pattern, a Zigzag scanning method proves a precise pattern generation. The other ways such as SEM scanning and swirl in-out scanning method result in some distorted pattern shape. It is proved that abrupt change in the pattern generation limits to obtaining a fine and small pattern.

  • PDF

MPEG-2 TM 5 복호기의 구조와 작동 (The overall structure and operation of MPEG-2 TM 5 decoder)

  • 김준기;이호석
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 1999년도 가을 학술발표논문집 Vol.26 No.2 (2)
    • /
    • pp.310-312
    • /
    • 1999
  • 본 논문은 MPEG-2 TM 5 비디오 복호기의 전체 구조와 처리과정을 기술한다. 주요한 MPEG-2 복호화 과정으로 비디오 syntax 분석, bitstream 복호 처리과정, quantization, DCT, scanning(zigzag 혹은 alternate scanning), 움직임 보상, frame 재구성, 화면 출력을 위한 dithering 과정이 있다. 본 논문에서는 MPEG-2 복호기의 핵심을 복호기 전체 구조, MPEG-2 bitstream syntax, MPEG-2 복호과정, 움직임 보상과 frame 재구성 그리고 화면 출력을 위한 dithering으로 구분하여 소개한다.

  • PDF

Adaptive Scanning Based on a Morphological Representation of Coefficients for H.264/AVC

  • Choi, Kang-Sun;Ko, Sung-Jea
    • ETRI Journal
    • /
    • 제31권5호
    • /
    • pp.607-609
    • /
    • 2009
  • In this letter, an effective scanning method based on a morphological representation of quantized coefficients is proposed for intra coding in H.264. In the proposed scanning method, the scan order for each block is adaptively reconfigured by exploiting a residual correlation beyond the border of the block. An initial scan order for the current block is determined first by using the pattern of nonzero coefficients in the adjacent block. Then, a complete scan order is obtained by performing the dilation operation at each position within the initial scan order. Experimental results show that the proposed method improves the coding efficiency up to 3.7% compared to the conventional zigzag scanning method.

MPEG-2 TM5 부호기의 구조와 작동 (The overall structure and operation of MPEG-2 TM5 encoder)

  • 김준기;이호석
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 1999년도 가을 학술발표논문집 Vol.26 No.2 (2)
    • /
    • pp.259-261
    • /
    • 1999
  • 본 논문은 MPEG-2 TM 5 video 부호기의 전체구조 및 처리과정을 기술한다. MPEG-2는 저장 매체, 통신, 방송 매체 등을 위한 동영상 압축이 표준이다. MPEG-2 압축 방법에는 공간적 압축과 시간적 압축 방법이 있다. 공간적 압축 방법에는 화면에서의 중복성을 줄이기 위한 표본화 주파수(4:4:4, 4:2:2, 4:2:0, format), DCT, scanning(zigzag 혹은 alternate scanning)과 quantization이 있고 시간적 압축 방법에는 움직임 예측(motion estimation)과 I, P, B-picture를 사용하는 방법이 있다. 본 논문에서는 MPEG-2 부호기의 핵심을 전체 구조, DPCM, MPEG bitstream syntax, MPEG-2 부호화 알고리즘, 움직임 예측, 움직임 벡터, rate control 그리고 가변길이 코딩(variable length coding)으로 구분하여 소개한다.

  • PDF

Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods

  • Mai, Hai Yen;Mai, Hang-Nga;Lee, Cheong-Hee;Lee, Kyu-Bok;Kim, So-yeun;Lee, Jae-Mok;Lee, Keun-Woo;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권2호
    • /
    • pp.88-95
    • /
    • 2022
  • PURPOSE. This study investigated the accuracy of full-arch intraoral scans obtained by various scan strategies with the segmental scan and merge methods. MATERIALS AND METHODS. Seventy intraoral scans (seven scans per group) were performed using 10 scan strategies that differed in the segmental scan (1, 2, or 3 segments) and the scanning motion (straight, zigzag, or combined). The three-dimensional (3D) geometric accuracy of scan images was evaluated by comparison with a reference image in an image analysis software program, in terms of the arch shape discrepancies. Measurement parameters were the intermolar distance, interpremolar distance, anteroposterior distance, and global surface deviation. One-way analysis of variance and Tukey honestly significance difference post hoc tests were carried out to compare differences among the scan strategy groups (α = .05). RESULTS. The linear discrepancy values of intraoral scans were not different among scan strategies performed with the single scan and segmental scan methods. In general, differences in the scan motion did not show different accuracies, except for the intermolar distance measured under the scan conditions of a 3-segmental scan and zigzag motion. The global surface deviations were not different among all scan strategies. CONCLUSION. The segmental scan and merge methods using two scan parts appear to be reliable as an alternative to the single scan method for full-arch intraoral scans. When three segmental scans are involved, the accuracy of complete arch scan can be negatively affected.

Self-Assembled Structures of Glutaric Acid on Cu(110)

  • 박은희;민영환;김세훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.270-270
    • /
    • 2013
  • We have investigated the self-assembled structures of glutaric acid (HOOC-(CH2)3-COOH) on the Cu(110) surface as a function of coverage using Scanning Tunneling Microscopy (STM). At low coverage, glutaric acid molecules diffuse freely on Cu(110) surface at room temperature, thus they can't form ordered structures at this coverage. However, when we scanned the same area several times, novel structures have been created during scanning due to the field-induced self-assembly. Also, the induced structures are quite stable during continuous scanning process. At 0.25 ML, glutaric acid adsorbs as a bi-glutarate (-OOC(CH2)3-COO-) after annealing to 450 K producing a racemic conglomerate of coexisting mirror domains. Although the molecule is achiral, it forms chiral domains on the surface from adsorption-induced asymmetrization. At 0.5 ML coverage, zigzag structure is observed, and still gltutaric acid adsorbs as a bidentate configuration. This bi-glutarate structure is stable until 650. Finally, at 1ML, glutaric acid adsorbs as a mono-glutarate at room temperature forming close packed structures.

  • PDF

직접식 금속 적층공정을 이용한 금속 시제품 제작 (Solid Freeform Fabrication of Metal Prototype Using Direct Metal Shaping Process)

  • 김재도;박진용;조명우
    • 한국정밀공학회지
    • /
    • 제17권10호
    • /
    • pp.56-62
    • /
    • 2000
  • A fast and precise technique to make 3-dimensional object which is called direct metal shaping process is processed. It is very useful technique in design and inspection. Using this developed system, a solid object is made. In experiment, test parts are built by varying three factors, laser power, scan path, scan speed. This process used device, which is different from the widely used in rapid prototyping in that powder feeding device is used. Spraying powder directly at the focused laser beam and then three dimensional object is made by the deposit of melted metal powder. The optimum scanning path is found to be zigzag path, which had little thermal affection on base metal. As a result of these experiments, it was found that optimum scanning speed is 15mm/sec laser power is 50W. This constructed 3-dimensional object could be used in mold manufacturing directly.

  • PDF

H.264 움직임 추정의 고속 2D PE 아키텍쳐 설계 및 구현 (A design and implementation of high-performance 2D PE architecture in H.264 Motion Estimation)

  • 이경호;공진흥
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.405-406
    • /
    • 2008
  • This paper presents a high performance 2D PE architecture for H.264 Motion Estimation(ME). While existing 2D PE architectures reuse the overlapped data of adjacent search windows scanned in 1 or 3-way, the new architecture scan adjacent windows and multiple paths instead of single raster and zigzag scanning of adjacent windows in 4 way(up,down,left,right). By reducing the redundant access factor by 1.4, the new 4-way search window improve the memory bandwidth by 70-58% compared with 1/3-way search window. With Altera Stratix-III implementation, the high performance 2D PE architecture deals with SD ($720{\times}480$) video of 2 reference frame, $48{\times}48$ search area and $16{\times}16$ macroblock by 30fps at 97.1MHz.

  • PDF