• Title/Summary/Keyword: Zigzag Scanning

Search Result 25, Processing Time 0.026 seconds

Adaptive Scanning for H.264/AVC Intra Coding

  • Lee, Yung-Lyul;Han, Ki-Hun;Sim, Dong-Gyu;Seo, Jeong-Il
    • ETRI Journal
    • /
    • v.28 no.5
    • /
    • pp.668-671
    • /
    • 2006
  • In this letter, an adaptive scanning that improves intra coding efficiency in the H.264/AVC standard is proposed. The proposed adaptive scanning utilizes the prediction directions (modes) that include the horizontal and vertical edge information in a block. Depending on the prediction directions, the proposed method uses three scanning methods: zigzag scanning, horizontal scanning, and vertical scanning. In the proposed method, horizontal and vertical scanning are used in vertical and horizontal prediction modes, respectively, and the normal zigzag scanning in the H.264 standard is used in all other intra prediction modes. The proposed method reduces the bit rate by approximately 2.5% compared with H.264/AVC, without the degradation of video quality.

  • PDF

Adsorption of H Atoms on the Si(111)$4{\times}1$-In Surface (Si(111)$4{\times}1$-In 표면에의 수소원자 흡착 연구)

  • Yu Sang-Yong;Lee Geun-Seop
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.2
    • /
    • pp.139-144
    • /
    • 2006
  • Using scanning tunneling microscopy (STM) measurements, we studied the adsorption of hydrogen on the Si(111)$4{\times}1$-In surface at room temperature. The H atom features are found to be located between the two protrusions in one side of the $4{\times}1$ chain. The adsorbed H preferentially occupies one of the two zigzag In subchains, suggesting that the adsorption of H is influenced by the subsurface structure. The adsorbed H atom induces not only a localized distortion but also perturbs the distant region and results in a period-doubling modulations in the STM images. This H-induced perturbation differs from the Na-Induced perturbation on the same surface.

Pattern Shape Modulation by Scanning Methods in E-Beam Lithography (전자빔 리소그래피를 이용한 주사기법에 따른 패턴형상 조정)

  • Oh, Se-Kyu;Kim, Seoung-Jae;Kim, Dong-Hwan;Park, Keun;Jang, Dong-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.558-564
    • /
    • 2009
  • To aim at obtaining a correct and fine small pattern by an electron beam lithography several conditions and methods affecting a real pattern shape needs to be investigated. A micro/nano sized pattern shape is sometimes dependent on the scanning method. In this work, four types of scanning methods are implemented and their characteristics are investigated. For a $11\times11um$ pattern, a Zigzag scanning method proves a precise pattern generation. The other ways such as SEM scanning and swirl in-out scanning method result in some distorted pattern shape. It is proved that abrupt change in the pattern generation limits to obtaining a fine and small pattern.

  • PDF

The overall structure and operation of MPEG-2 TM 5 decoder (MPEG-2 TM 5 복호기의 구조와 작동)

  • 김준기;이호석
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.310-312
    • /
    • 1999
  • 본 논문은 MPEG-2 TM 5 비디오 복호기의 전체 구조와 처리과정을 기술한다. 주요한 MPEG-2 복호화 과정으로 비디오 syntax 분석, bitstream 복호 처리과정, quantization, DCT, scanning(zigzag 혹은 alternate scanning), 움직임 보상, frame 재구성, 화면 출력을 위한 dithering 과정이 있다. 본 논문에서는 MPEG-2 복호기의 핵심을 복호기 전체 구조, MPEG-2 bitstream syntax, MPEG-2 복호과정, 움직임 보상과 frame 재구성 그리고 화면 출력을 위한 dithering으로 구분하여 소개한다.

  • PDF

Adaptive Scanning Based on a Morphological Representation of Coefficients for H.264/AVC

  • Choi, Kang-Sun;Ko, Sung-Jea
    • ETRI Journal
    • /
    • v.31 no.5
    • /
    • pp.607-609
    • /
    • 2009
  • In this letter, an effective scanning method based on a morphological representation of quantized coefficients is proposed for intra coding in H.264. In the proposed scanning method, the scan order for each block is adaptively reconfigured by exploiting a residual correlation beyond the border of the block. An initial scan order for the current block is determined first by using the pattern of nonzero coefficients in the adjacent block. Then, a complete scan order is obtained by performing the dilation operation at each position within the initial scan order. Experimental results show that the proposed method improves the coding efficiency up to 3.7% compared to the conventional zigzag scanning method.

The overall structure and operation of MPEG-2 TM5 encoder (MPEG-2 TM5 부호기의 구조와 작동)

  • 김준기;이호석
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.259-261
    • /
    • 1999
  • 본 논문은 MPEG-2 TM 5 video 부호기의 전체구조 및 처리과정을 기술한다. MPEG-2는 저장 매체, 통신, 방송 매체 등을 위한 동영상 압축이 표준이다. MPEG-2 압축 방법에는 공간적 압축과 시간적 압축 방법이 있다. 공간적 압축 방법에는 화면에서의 중복성을 줄이기 위한 표본화 주파수(4:4:4, 4:2:2, 4:2:0, format), DCT, scanning(zigzag 혹은 alternate scanning)과 quantization이 있고 시간적 압축 방법에는 움직임 예측(motion estimation)과 I, P, B-picture를 사용하는 방법이 있다. 본 논문에서는 MPEG-2 부호기의 핵심을 전체 구조, DPCM, MPEG bitstream syntax, MPEG-2 부호화 알고리즘, 움직임 예측, 움직임 벡터, rate control 그리고 가변길이 코딩(variable length coding)으로 구분하여 소개한다.

  • PDF

Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods

  • Mai, Hai Yen;Mai, Hang-Nga;Lee, Cheong-Hee;Lee, Kyu-Bok;Kim, So-yeun;Lee, Jae-Mok;Lee, Keun-Woo;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.88-95
    • /
    • 2022
  • PURPOSE. This study investigated the accuracy of full-arch intraoral scans obtained by various scan strategies with the segmental scan and merge methods. MATERIALS AND METHODS. Seventy intraoral scans (seven scans per group) were performed using 10 scan strategies that differed in the segmental scan (1, 2, or 3 segments) and the scanning motion (straight, zigzag, or combined). The three-dimensional (3D) geometric accuracy of scan images was evaluated by comparison with a reference image in an image analysis software program, in terms of the arch shape discrepancies. Measurement parameters were the intermolar distance, interpremolar distance, anteroposterior distance, and global surface deviation. One-way analysis of variance and Tukey honestly significance difference post hoc tests were carried out to compare differences among the scan strategy groups (α = .05). RESULTS. The linear discrepancy values of intraoral scans were not different among scan strategies performed with the single scan and segmental scan methods. In general, differences in the scan motion did not show different accuracies, except for the intermolar distance measured under the scan conditions of a 3-segmental scan and zigzag motion. The global surface deviations were not different among all scan strategies. CONCLUSION. The segmental scan and merge methods using two scan parts appear to be reliable as an alternative to the single scan method for full-arch intraoral scans. When three segmental scans are involved, the accuracy of complete arch scan can be negatively affected.

Self-Assembled Structures of Glutaric Acid on Cu(110)

  • Park, Eun-Hui;Min, Yeong-Hwan;Kim, Se-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.270-270
    • /
    • 2013
  • We have investigated the self-assembled structures of glutaric acid (HOOC-(CH2)3-COOH) on the Cu(110) surface as a function of coverage using Scanning Tunneling Microscopy (STM). At low coverage, glutaric acid molecules diffuse freely on Cu(110) surface at room temperature, thus they can't form ordered structures at this coverage. However, when we scanned the same area several times, novel structures have been created during scanning due to the field-induced self-assembly. Also, the induced structures are quite stable during continuous scanning process. At 0.25 ML, glutaric acid adsorbs as a bi-glutarate (-OOC(CH2)3-COO-) after annealing to 450 K producing a racemic conglomerate of coexisting mirror domains. Although the molecule is achiral, it forms chiral domains on the surface from adsorption-induced asymmetrization. At 0.5 ML coverage, zigzag structure is observed, and still gltutaric acid adsorbs as a bidentate configuration. This bi-glutarate structure is stable until 650. Finally, at 1ML, glutaric acid adsorbs as a mono-glutarate at room temperature forming close packed structures.

  • PDF

Solid Freeform Fabrication of Metal Prototype Using Direct Metal Shaping Process (직접식 금속 적층공정을 이용한 금속 시제품 제작)

  • Kim, Jae-Do;Park, Jin-Yong;Cho, Myeong-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.56-62
    • /
    • 2000
  • A fast and precise technique to make 3-dimensional object which is called direct metal shaping process is processed. It is very useful technique in design and inspection. Using this developed system, a solid object is made. In experiment, test parts are built by varying three factors, laser power, scan path, scan speed. This process used device, which is different from the widely used in rapid prototyping in that powder feeding device is used. Spraying powder directly at the focused laser beam and then three dimensional object is made by the deposit of melted metal powder. The optimum scanning path is found to be zigzag path, which had little thermal affection on base metal. As a result of these experiments, it was found that optimum scanning speed is 15mm/sec laser power is 50W. This constructed 3-dimensional object could be used in mold manufacturing directly.

  • PDF

A design and implementation of high-performance 2D PE architecture in H.264 Motion Estimation (H.264 움직임 추정의 고속 2D PE 아키텍쳐 설계 및 구현)

  • Lee, Kyung-Ho;Kong, Jin-Hyeung
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.405-406
    • /
    • 2008
  • This paper presents a high performance 2D PE architecture for H.264 Motion Estimation(ME). While existing 2D PE architectures reuse the overlapped data of adjacent search windows scanned in 1 or 3-way, the new architecture scan adjacent windows and multiple paths instead of single raster and zigzag scanning of adjacent windows in 4 way(up,down,left,right). By reducing the redundant access factor by 1.4, the new 4-way search window improve the memory bandwidth by 70-58% compared with 1/3-way search window. With Altera Stratix-III implementation, the high performance 2D PE architecture deals with SD ($720{\times}480$) video of 2 reference frame, $48{\times}48$ search area and $16{\times}16$ macroblock by 30fps at 97.1MHz.

  • PDF