• Title/Summary/Keyword: Zero-rating

Search Result 66, Processing Time 0.019 seconds

A Fully Soft Switched Full Bridge DC-DC converter (보조회로도 영전압영전류스위칭하는 DC-DC 변환기)

  • Jeon, Seong-Jeub;Cho, Gyu-Hyeong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2512-2514
    • /
    • 1999
  • A new zero voltage and zero current switching(ZVZCS) full bridge DC-DC converter with transformer isolation is proposed for arc welding machines. The proposed DC-DC converter uses an auxiliary transformer to obtain ZCS for leading leg, which provides load current control capability even in short circuit condition. The auxiliary circuit also operates in ZVZCS mode. The power rating of the auxiliary transformer is about 10% of the main transformer. The operation is verified by experiments for 12[KW] prototype.

  • PDF

Stage-Discharge Rating Curve Model Development and Modification (하천 수위-유량곡선식 개선 및 모형개발)

  • Chang, Ki-Hwan;Lee, Jae-Hyoung
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.4 s.153
    • /
    • pp.271-280
    • /
    • 2005
  • The goal of this study is to recommend a new type of stage-discharge rating curve ($Q=p(h-e)^{\beta}-{\gamma}$) useful for satisfying divergence, and one other seemingly irresolvable problem related to exited rating curves, while also extending this rating curve model. The problem of divergence is that during the finding of the CZF (cease-to-zero flow) parameter e and while minimizing the sum of total errors of the estimated curve, the exponential parameter ${\beta}$ become an abnormally large value. The insoluble problem is that when the value e is greater then the recorded minimum at the gauged stage, it is impossible to have a negative logarithm value (h-e). The two problems above can be satisfied by adapting the control value ${\gamma}$, which affects the reduction of ${\gamma}$ and gives us the possibility of controlling (h-e) over zero. The study results show that the effects of parameter ${\gamma}$ are very similar to that of e when conducting physical and sensitivity analyses. This system can be used towards developing a new stage-discharge rating curve for river discharge, for use in evaluating the acceptability of existing stage-discharge rating curves generated by using hydrologic analyses at all stations.

Zero-Phase Angle Frequency Tracking Control of Wireless Power Transfer System for Electric Vehicles using Characteristics of LCCL-S Topology (LCCL-S 토폴로지 특성을 이용한 전기자동차용 무선충전시스템의 ZPA 주파수 추종 제어)

  • Byun, Jongeun;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.404-411
    • /
    • 2020
  • Inductive power transfer (IPT) systems for electric vehicles generally require zero phase angle (ZPA) frequency tracking control to achieve high efficiency. Current sensors are used for ZPA frequency tracking control. However, the use of current sensors causes several problems, such as switching noise, degrading control performance, and control complexity. To solve these problems, this study proposes ZPA frequency tracking control without current sensors. Such control enables ZPA frequency tracking without real-time control and achieves stable zero voltage switching operation closed to ZPA frequency within all coupling coefficient and load ranges. The validity of the proposed control algorithm is verified on LCCL-S topology with a 3.3 kW rating IPT experimental test bed. Simulation verification is also performed.

A Study on the BUCK ZC-ZVS Converter with Reduced Conduction Losses (도통손실을 감소시킨 강압형 영전류-영전압 컨버터에 관한 연구)

  • Lee, Yo-Seop;Lee, Won-Seok;Lee, Seong-Baek
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.12
    • /
    • pp.686-691
    • /
    • 1999
  • In a switching power supply, the high frequency switching makes the passive components small, but the losses and the stresses of switches are increased by the switching frequency. Therefore, zero crossing technology using resonant is used to improve defect in high switching. In generally, zero crossing switching consists of Zero Current Switching(ZCS) and Zero Voltage Switching(ZVS). This paper proposes A Buck ZC-ZVS Converter with Reduced Conduction Losses. Comparing with a conventional Buck ZC-ZVS Converter, the proposed converter operates with the smaller rated power. This is achieved by changing the auxiliary switch position, which reduces its rating power. Simulation results using Pspice program about test circuit with rated 160W(30V, 5.3A) at 30kHz and experiment result under same condition were described in the paper.

  • PDF

A Study on the Methodology of Building Energy Consumption Estimation and Energy Independence Rate for Zero Energy City Planning Phase (제로에너지시티 계획을 위한 건물에너지 수요 예측 방법론 개발 및 자립률 산정에 대한 연구)

  • Bae, Eun-ji;Yoon, Yong Sang
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.5
    • /
    • pp.29-40
    • /
    • 2019
  • In response to the rapid climate change, in order to save energy in the field of buildings, the country is planning not only zero energy buildings but also zero energy cities. In the Urban Development Project, the Energy Use Plan Report is prepared and submitted by predicting the amount of energy demand at the planning stage. However, due to the activation of zero-energy buildings and the increase in the supply of new and renewable energy facilities, the energy consumption behavior of buildings in the city is changing from the previous ones. In this study, to estimate urban energy demand of Zero Energy City, building energy demand forecasts based on "Passive plans for use of energy based primary energy consumption", "Actual building energy usage data from Korea Appraisal Board" and "data from Certification of Building Energy Efficiency Rating" as well as demand forecast according to existing "Consultation about Energy Use Plan Code" were calculated and then applied to Multifunctional Administrative City 5-1 zone to compare urban total energy demand forecasts.

Analysis of Rubber-dam hydrologic Character for the River Environment Monitoring (하천환경 모니터링을 위한 취수보의 수문특성 분석)

  • Seo, Kyu-woo;Kim, Dai-gon;Kim, Su-hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1326-1330
    • /
    • 2004
  • This study analyzes the rubber-dam of hydrologic character to be located in a Nagdong-river main stream in Dasamyeon Juggogli of the Dae-gu global city lot the river environment monitoring. The purpose of this research investigates the influence according to the rubber-dam install scientificly. A result natural disposition, prepare the gauge to matte the width of the area of the understanding and the computation of the rating which Apply is possible. Into the result of this research, $Q=898.8h^2-26126h+189886$ edge was computed to the rating. Also this study use the now rate to get for an upside expression and analysis a water balance. Through the officer to be efficient a hereafter seminar zero and processing of the data to be acquired, the supplementation so that this study can share the data to the online. High practical use of the The self-governinig body of the data and data confirmed report which loses in the trust will be achieved.

  • PDF

LCL Type Series Resonant Converter with PWM Control Method (PWM 제어 방법을 이용한 LCL 직렬 공진 콘버터에 관한 연구)

  • 현동석;이요한;추병호;송인호;민경진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.19-28
    • /
    • 1997
  • A simple AC complex circuit analysis for LCL type series resonant converter with phase shift control is proposed. Based on these analyses, a set of characteristic curves which allows a optimal design procedure for this converter is shown, without increasing the volt-ampere rating of tank circuit. Especially, inverter output peak current can be minimized in both full load and partial load conditions. The presented design considerations can make the load range wide from full loads to light loads achieving turn-on with zero voltage switching (ZVS) operation. The simulation and experimental results show the effectiveness of the proposed design algorithms.

  • PDF

Analysis and Design of a Current-fed Two Inductor Bi-directional DC/DC Converter using Resonance for a Wide Voltage Range

  • Noh, Yong-Su;Kim, Bum-Jun;Choi, Sung-Chon;Kim, Do-Yun;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1634-1644
    • /
    • 2016
  • In this paper, a current-fed two-inductor bi-directional DC/DC converter using resonance (CF-TIBCR) and its design method are proposed. The CF-TIBCR has characteristics of low current ripple and a high current rating because of two separated inductors. Also, it achieves zero voltage switching for all switches and zero current switching for switches of a low voltage stage by using the resonant tank. Besides, a voltage spike problem in conventional current-fed converters is solved without the need for an additional snubber or clamping circuits. As a result, the CF-TIBCR features high step-up and high efficiency. Since the proposed converter has difficulty achieving the soft-switching condition when the converter requires the low voltage transfer ratio, a method that varies the number of resonant cycles is adopted to extend the output voltage range with satisfying the soft-switching condition. The principles of the operation characteristics are presented with a theoretical analysis, and the proposed converter is verified through results of an experiment using a laboratory prototype.

Evaluation of Energy Self-Sufficiency Rate through Case Analysis of Building Energy Efficiency Rating in Educational Facilities (교육시설의 건축물에너지효율등급 사례분석을 통한 에너지자립률 평가)

  • Lee, Hyun-Seung;Kim, Ji-Hyeon;Lee, Seung-Min;Meang, Joon-Ho;Shin, U-Cheul
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.4
    • /
    • pp.58-65
    • /
    • 2019
  • Under the regulation of rational energy use in public institutions, it has been mandatory for educational facilities to meet the first grade or higher since 2014. Also the regulation has forced educational facilities as public institutions to use renewable energy since September 2008. Educational facilities are required to be qualified as zero-energy buildings from 2020 under the revision of the Green Building Act. In this study, we identified the current status of the building energy efficiency rating system and the renewable energy system installation for 316 educational facilities that were accredited as "building energy efficiency rating system" from February 2015 to March 2019. Also we analyzed the energy self-sufficiency rate based on energy requirements and renewable energy output. Of the 316 facilities, 12 had 1++ and 293 had 1++ for the "Building Energy Efficiency Rating System". Among the 12 facilities which had 1+++, 11 recorded ZEB level 5 or higher, and 28 out of the 293 facilities(11%) which got received 1++ had ZEB level 5. Thus, it is impossible to implement the ZEB certification system for educational facilities under the present conditions. Expanding the ratio of 1+++ and investing in renewable energy systems should be preceded.

Resonant Step-Down DC/DC Converter to Reduce Voltage Stresses of Motor Driving Inverter under 3-phase AC Utility Line Condition (3상 전원 조건의 모터 구동 인버터 내압 저감을 위한 공진 강압형 DC/DC 컨버터)

  • Kang, Kyung-Soo;Kim, Sang-Eon;Lee, Joon-Hwan;Roh, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.391-398
    • /
    • 2014
  • This paper presents a resonant step-down DC/DC converter to reduce the voltage stresses of a 3-phase inverter module under the three-phase AC utility line condition. Under this condition, a conventional 3-phase inverter module suffers from high voltage stresses as a result of the high rectified DC link voltage; hence, a high-cost high-voltage-rating inverter module must be used. However, using the proposed converter, a low-cost low-voltage-rating inverter module may be adopted to drive the motor even under the 3-phase AC line condition. The proposed converter, which can be realized with small size inductor and low-voltage-rating semiconductor devices, operates at a high-efficiency mode because of the zero-current switching operations of all the semiconductor devices. The operational principles are explained and a design example is provided in the study. Experimental results demonstrate the validity of the proposed converter.