• Title/Summary/Keyword: Zero-rate Output

Search Result 92, Processing Time 0.024 seconds

Computationally-Efficient Algorithms for Multiuser Detection in Short Code Wideband CDMA TDD Systems

  • De, Parthapratim
    • Journal of Communications and Networks
    • /
    • v.18 no.1
    • /
    • pp.27-39
    • /
    • 2016
  • This paper derives and analyzes a novel block fast Fourier transform (FFT) based joint detection algorithm. The paper compares the performance and complexity of the novel block-FFT based joint detector to that of the Cholesky based joint detector and single user detection algorithms. The novel algorithm can operate at chip rate sampling, as well as higher sampling rates. For the performance/complexity analysis, the time division duplex (TDD) mode of a wideband code division multiplex access (WCDMA) is considered. The results indicate that the performance of the fast FFT based joint detector is comparable to that of the Cholesky based joint detector, and much superior to that of single user detection algorithms. On the other hand, the complexity of the fast FFT based joint detector is significantly lower than that of the Cholesky based joint detector and less than that of the single user detection algorithms. For the Cholesky based joint detector, the approximate Cholesky decomposition is applied. Moreover, the novel method can also be applied to any generic multiple-input-multiple-output (MIMO) system.

Implementation of TDD LTE-Advanced Testbed adopted Dynamic Pre-coding for MU-MIMO (MU-MIMO를 위한 동적 Pre-coding을 적용한 TDD LTE-Advanced 테스트베드의 구현)

  • Han, Sangwook;Lee, Jeonghyeok;Choi, Seungwon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.18 no.2
    • /
    • pp.27-37
    • /
    • 2022
  • In this paper, we presents a Multiple User Multiple Input Multiple Output (MU-MIMO) test-bed system for Time Division Duplex (TDD) Long Term Evolution-Advanced (LTE-A). Using two parameters, the condition number of the channel matrix and the path gain, the MU-MIMO system could switch pre-coder to maintain target Bit Error Rate (BER) level. This paper also introduces a calibration procedure for compensating error of Radio Frequency (RF) paths of the antennas and RF transceivers. From experimental measurements, dynamic pre-coding scheme could maintain target BER, set to 10-3, with the pre-coder set configured with Zero Forcing (ZF), Tomlinson Harashima Pre-coding (THP), Lattice Reduction (LR). The simplest pre-coder ZF is adopted in stable channel, and when path gain become less than 0.25, LR is adopted. Lastly, when condition number of channel matrix become larger than 7, THP is adopted.

Evaluation of Energy Self-Sufficiency Rate through Case Analysis of Building Energy Efficiency Rating in Educational Facilities (교육시설의 건축물에너지효율등급 사례분석을 통한 에너지자립률 평가)

  • Lee, Hyun-Seung;Kim, Ji-Hyeon;Lee, Seung-Min;Meang, Joon-Ho;Shin, U-Cheul
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.4
    • /
    • pp.58-65
    • /
    • 2019
  • Under the regulation of rational energy use in public institutions, it has been mandatory for educational facilities to meet the first grade or higher since 2014. Also the regulation has forced educational facilities as public institutions to use renewable energy since September 2008. Educational facilities are required to be qualified as zero-energy buildings from 2020 under the revision of the Green Building Act. In this study, we identified the current status of the building energy efficiency rating system and the renewable energy system installation for 316 educational facilities that were accredited as "building energy efficiency rating system" from February 2015 to March 2019. Also we analyzed the energy self-sufficiency rate based on energy requirements and renewable energy output. Of the 316 facilities, 12 had 1++ and 293 had 1++ for the "Building Energy Efficiency Rating System". Among the 12 facilities which had 1+++, 11 recorded ZEB level 5 or higher, and 28 out of the 293 facilities(11%) which got received 1++ had ZEB level 5. Thus, it is impossible to implement the ZEB certification system for educational facilities under the present conditions. Expanding the ratio of 1+++ and investing in renewable energy systems should be preceded.

Economic Evaluation of Coupling APR1400 with a Desalination Plant in Saudi Arabia

  • Abdoelatef, M. Gomaa;Field, Robert M.;Lee, YongKwan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.12 no.1
    • /
    • pp.73-87
    • /
    • 2016
  • Combining power generation and water production by desalination is economically advantageous. Most desalination projects use fossil fuels as an energy source, and thus contribute to increased levels of greenhouse gases. Environmental concerns have spurred researchers to find new sources of energy for desalination plants. The coupling of nuclear power production with desalination is one of the best options to achieve growth with lower environmental impact. In this paper, we will per-form a sensitivity study of coupling nuclear power to various combinations of desalination technology: {1} thermal (MSF [Multi-Stage Flashing], MED [Multi-Effect Distillation], and MED-TVC [Multi-Effect Distillation with Thermal Vapour Compression]); {2} membrane RO [Reverse Osmosis]; and {3} hybrid (MSF-RO [Multi-Stage Flashing & Reverse Osmosis] and MED-RO [Multi-Effect Distillation & Reverse Osmosis]). The Korean designed reactor plant, the APR1400 will be modeled as the energy production facility. The economical evaluation will then be executed using the computer program DEEP (Desalination Economic Evaluation Program) as developed by the IAEA. The program has capabilities to model several types of nuclear and fossil power plants, nuclear and fossil heat sources, and thermal distillation and membrane desalination technologies. The output of DEEP includes levelized water and power costs, breakdowns of cost components, energy consumption, and net saleable power for any selected option. In this study, we will examine the APR1400 coupled with a desalination power plant in the Kingdom of Saudi Arabia (KSA) as a prototypical example. The KSA currently has approximately 20% of the installed worldwide capacity for seawater desalination. Utilities such as power and water are constructed and run by the government. Per state practice, economic evaluation for these utilities do not consider or apply interest or carrying cost. Therefore, in this paper the evaluation results will be based on two scenarios. The first one assumes the water utility is under direct government control and in this case the interest and discount rate will be set to zero. The second scenario will assume that the water utility is controlled by a private enterprise and in this case we will consider different values of interest and discount rates (4%, 8%, & 12%).

A Study on the Wet Clutch Pattern Design for the Drag Torque Reduction in Wet DCT System (습식 DCT의 드래그 토크 저감을 위한 클러치 패드 유로 설계)

  • Cho, Junghee;Han, Juneyeol;Kim, Woo-Jung;Jang, Siyoul
    • Tribology and Lubricants
    • /
    • v.33 no.2
    • /
    • pp.71-78
    • /
    • 2017
  • The drag torque in the wet clutch system of a dual clutch transmission system is investigated because it is relatively high, up to 10 of the total output torque of the engine, even when the clutch is in the disengagement state with zero torque transfer. Drag torque results from the shear resistance of the DCTF between the friction pad and separator plate. To reduce the drag torque for ensuring fuel economy, the groove pattern of the wet clutch friction pad is designed to have a high flow rate through the pattern groove. In this study, four types of groove patterns on the friction pad are designed. The volume fraction of the DCTF (VOF) and hydrodynamic pressure developments in the gap between the friction pad and separator plate are computed to correlate with the computation of the drag torque. From the computational results, it is found that a high VOF and hydrodynamics increase the drag torque resulting from the shear resistance of the DCTF. Therefore, a patterned groove design should be used for increasing the flow rate to have more air parts in the gap to reduce the drag torque. In this study, ANSYS FLUENT is used to solve the flow analysis.

Design of a Fourth-Order Sigma-Delta Modulator Using Direct Feedback Method (직접 궤환 방식의 모델링을 이용한 4차 시그마-델타 변환기의 설계)

  • Lee, Bum-Ha;Choi, Pyung;Choi, Jun-Rim
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.6
    • /
    • pp.39-47
    • /
    • 1998
  • A fourth-order $\Sigma$-$\Delta$ modulator is designed and implemented in 0.6 $\mu\textrm{m}$ CMOS technology. The modulator is verified by introducing nonlinear factors such as DC gain and slew rate in system model that determines the transfer function in S-domain and in time-domain. Dynamic range is more than 110 dB and the peak SM is 102.6 dB at a clock rate of 2.8224 MHz for voiceband signal. The structure of a ∑-$\Delta$ modulator is a modified fourth-order ∑-$\Delta$ modulator using direct feedback loop method, which improves performance and consumes less power. The transmission zero for noise is located in the first-second integrator loop, which reduces entire size of capacitors, reduces the active area of the chip, improves the performance, and reduces power dissipation. The system is stable because the output variation with respect to unit time is small compared with that of the third integrator. It is easy to implement because the size of the capacitor in the first integrator, and the size of the third integrator is small because we use the noise reduction technique. This paper represents a new design method by modeling that conceptually decides transfer function in S-domain and in Z-domain, determines the cutoff frequency of signal, maximizes signal power in each integrator, and decides optimal transmission-zero frequency for noise. The active area of the prototype chip is 5.25$\textrm{mm}^2$, and it dissipates 10 mW of power from a 5V supply.

  • PDF

Performance Analysis of Asynchronous 2.5 Gbps / 622Mbps Optical Subscriber Network with Manchester coded Downstream and NRZ upstream re-modulation (맨체스터 부호로 코딩된 하향신호의 재변조를 이용한 비동기 2.5 Gbps / 622 Mbps 광가입자 망의 성능 분석)

  • Park, Sang-Jo;Kim, Bong-Kyu
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.3
    • /
    • pp.143-147
    • /
    • 2009
  • We propose an asymmetrical 2.5 Gbps / 622 Mbps bidirectional optical subscriber network with Manchester coded downstream and NRZ (Non-Return-to-Zero) upstream remodulation. The proposed system has important characteristics in the optical network unit (ONU): it does not require a light source or the usual control circuits such as wavelength control and output power control, and it is possible to use a synchronization scheme between upstream and downstream data. We theoretically analyze BER(Bit Error Rate) performance of upstream data remodulated with Manchester coded downstream according to the types of NRZ downstream data and perform simulations with MATLAB. The BER performance and the receiver sensitivity have been improved by 3 dB by adjusting threshold levels compared to the conventional receiver. The results have shown the remodulation scheme with Manchester coded downstream could be a useful technology for asynchronous and asymmetric optical subscriber networks with low cost and simple structures.

Complexity Limited Sphere Decoder and Its SER Performance Analysis (스피어 디코더에서 최대 복잡도 감소 기법 및 SER 성능 분석)

  • Jeon, Eun-Sung;Yang, Jang-Hoon;Kim, Bong-Ku
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.6A
    • /
    • pp.577-582
    • /
    • 2008
  • In this paper, we present a scheme to overcome the worst case complexity of the sphere decoder. If the number of visited nodes reaches the threshold, the detected symbol vector is determined between two candidate symbol vectors. One candidate symbol vector is obtained from the demodulated output of ZF receiver which is initial stage of the sphere decoder. The other candidate symbol vector consists of two sub-symbol vectors. The first sub-symbol vector consists of lately visited nodes running from the most upper layer. The second one contains corresponding demodulated outputs of ZF receiver. Between these two candidate symbol vectors, the one with smaller euclidean distance to the received symbol vector is chosen as detected symbol vector. In addition, we show the upper bound of symbol error rate performance for the sphere decoder using the proposed scheme. In the simulation, the proposed scheme shows the significant reduction of the worst case complexity while having negligible SER performance degradation.

Development of Synthetic Jet Micro Air Pump (Synthetic Jet 마이크로 에어펌프의 개발)

  • Choi, J.P.;Kim, K.S.;Seo, Y.H.;Ku, B.S.;Jang, J.H.;Kim, B.H.
    • Transactions of Materials Processing
    • /
    • v.17 no.8
    • /
    • pp.594-599
    • /
    • 2008
  • This paper presents a micro air pump based on the synthetic jet to supply reactant at the cathode side for micro fuel cells. The synthetic jet is a zero mass flux device that converts electrical energy into the momentum. The synthetic jet actuation is usually generated by a traditional PZT-driven actuator, which consists of a small cylindrical cavity, orifices and PZT diaphragms. Therefore, it is very important that the design parameters are optimized because of the simple configuration. To design the synthetic jet micro air pump, a numerical analysis has been conducted for flow characteristics with respect to various geometries. From results of numerical analysis, the micro air pump has been fabricated by the PDMS replication process. The most important design factors of the micro air pump in micro fuel cells are the small size and low power consumption. To satisfy the design targets, we used SP4423 micro chip that is high voltage output DC-AC converter to control the PZT. The SP4423 micro chips can operate from $2.2{\sim}6V$ power supply(or battery) and is capable of supplying up to 200V signals. So it is possible to make small size controller and low power consumption under 0.1W. The size of micro air pump was $16{\times}13{\times}3mm^3$ and the performance test was conducted. With a voltage of 3V at 800Hz, the air pump's flow rate was 2.4cc/min and its power consumption was only 0.15W.

Effect of Intake Pressure on Emissions and Performance in Low Temperature Combustion Operation of a Diesel Engine (디젤 저온연소 운전 영역에서 흡기압이 엔진 성능에 주는 영향)

  • Lee, Sun-Youp;Chang, Jae-Hoon;Lee, Yong-Gyu;Oh, Seung-Mook;Kim, Yong-Rae;Kim, Duk-Sang
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.88-94
    • /
    • 2012
  • One of the effective ways to reduce both $NO_x$ and PM at the same time in a diesel CI engine is to operate the engine in low temperature combustion (LTC) regimes. In general, two strategies are used to realize the LTC operation-dilution controlled LTC and late injection LTC - and in this study, the former approach was used. In the dilution controlled regime, LTC is achieved by supplying a large amount of EGR to the cylinder. The significant EGR gas increases the heat capacity of in-cylinder charge mixture while decreasing oxygen concentration of the charge, activating low temperature oxidation reaction and lowering PM and $NO_x$ emissions. However, use of high EGR levels also deteriorates combustion efficiency and engine power output. Therefore, it is widely considered to use increased intake pressure as a way to resolve this issue. In this study, the effects of intake pressure variations on performance and emission characteristics of a single cylinder diesel engine operated in LTC regimes were examined. LTC operation was achieved in less than 8% $O_2$ concentration and thus a simultaneous reduction of both PM and $NO_x$ emission was confirmed. As intake pressure increased, combustion efficiency was improved so that THC and CO emissions were decreased. A shift of the peak Soot location was also observed to lower $O_2$ concentration while $NO_x$ levels were kept nearly zero. In addition, an elevation of intake pressure enhanced engine power output as well as indicated thermal efficiency in LTC regimes. All these results suggested that LTC operation range can be extended and emissions can be further reduced by adjusting intake pressure.