• Title/Summary/Keyword: Zero standby power

Search Result 5, Processing Time 0.029 seconds

An Input-Powered High-Efficiency Interface Circuit with Zero Standby Power in Energy Harvesting Systems

  • Li, Yani;Zhu, Zhangming;Yang, Yintang;Zhang, Chaolin
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1131-1138
    • /
    • 2015
  • This study presents an input-powered high-efficiency interface circuit for energy harvesting systems, and introduces a zero standby power design to reduce power consumption significantly while removing the external power supply. This interface circuit is composed of two stages. The first stage voltage doubler uses a positive feedback control loop to improve considerably the conversion speed and efficiency, and boost the output voltage. The second stage active diode adopts a common-grid operational amplifier (op-amp) to remove the influence of offset voltage in the traditional comparator, which eliminates leakage current and broadens bandwidth with low power consumption. The system supplies itself with the harvested energy, which enables it to enter the zero standby mode near the zero crossing points of the input current. Thereafter, high system efficiency and stability are achieved, which saves power consumption. The validity and feasibility of this design is verified by the simulation results based on the 65 nm CMOS process. The minimum input voltage is down to 0.3 V, the maximum voltage efficiency is 99.6% with a DC output current of 75.6 μA, the maximum power efficiency is 98.2% with a DC output current of 40.4 μA, and the maximum output power is 60.48 μW. The power loss of the entire interface circuit is only 18.65 μW, among which, the op-amp consumes only 2.65 μW.

Cost-effective Power System with an Electronic Double Layer Capacitor for Reducing the Standby Power Consumption of Consumer Electronic Devices

  • Park, Kyung-Hwa;Yi, Kang-Hyun
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.362-368
    • /
    • 2013
  • Commercial home appliances using remotely controlled systems consume electric power while in standby mode to prepare for receiving a remote turn-on signal. The proposed power system can significantly reduce standby power consumption without increasing cost. Furthermore, since a Electronic Double Layer Capacitor (EDLC) is used as an auxiliary power storage element, the life cycle is longer and system reliability can be better than with existing approaches. When the energy of the EDLC is not sufficient for turning on the appliance, the power system charges the EDLC without affecting the main system. The proposed power system is verified with a commercial LCD TV and a 3.93mW standby consumption is obtained. This standby consumption can be regarded as zero standby equipment according to the IEC-62031 standard.

Method and implementation for reducing standby power consumption in intermediate capacity power supply with Power Line Communication (전력선통신기능 적용 중.대용량 전원공급장치의 대기전력 절감방법 및 구현)

  • Son, Do-Sun;Kim, Ki-Hyun;Kim, Sang-Cheol;Jeon, Eui-Seok;Lee, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1947-1948
    • /
    • 2008
  • This paper presents the implementation of Power Line Communication(PLC) module which can reduce standby-power consumption. The suggested PLC module consists of PLC modem, coupling circuit, ZCP(Zero-Cross Point) Circuit and main SMPS control relay. The test results under power line communication test-bed used home appliance show the 77% saving of standby-power.

  • PDF

A Study on the Fabrication of the Sensor Module for the Detection of Resistive Leakage Current (Igr) in Real Time and Its Reliability Evaluation (실시간 Igr 검출을 위한 센서 모듈의 제작 및 신뢰성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.28-34
    • /
    • 2018
  • The purpose of this study is to fabricate a sensor module to detect the resistive leakage current (Igr) in real time that occurs to low voltage electric lines and to verify its reliability. In the case of the developed sensor module, wires are inserted into the zero current transformer (ZCT) and current transformer (CT) in advance and then the branch line is connected to the circuit breaker. The measurement result of the resistance of the distribution panel equipped with the developed sensor module shows that the resistance is $0.151m{\Omega}$ between the R and R phases, $0.169m{\Omega}$ between the S and S phases, and $0.178m{\Omega}$ between the T and T phases, respectively. The insulation resistance measured at AC 500 V and 1,000 V is $0.08m{\Omega}$ between the R, S, T and N phases, respectively. Then, the insulation resistance measured at DC 500 V is $83.3G{\Omega}$ between the R, S, T and G terminal, respectively. In addition, the applied withstanding voltage is AC 220 V/380 V/440 V and it was found that characteristics between all phases are good. This study measured the standby power by installing the developed sensor module at the rear of the MCCB and switching the circuit breaker on sequentially. The standby power is 1.350 W when one circuit breaker is turned on, 1.690 W when 2 circuit breakers are turned on, and 4.371 W when 10 circuit breakers are turned on. This study also verified the reliability of the standby power of the distribution panel equipped with the developed sensor module using the Minitab Program (Minitab PGM). Since the analysis shows the statistical average of 1.34627 in the reliable range of normal distribution, standard deviation of 0.001874, AD of 0.554, and P value of 0.140, it is found that the distribution panel equipped with the developed sensor module has high reliability.

A Study on the Effective Maintenance Method of the Stair Passage Leading Light installed In the Shopping Building (상가건물 계단통로유도등의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • This study was conducted by survey and inspection of stair passage leading lights in shopping buildings which are more than 5 stories and have an underground parking lot located at Pyeongtaek-si and Seongnam-si. Number of shopping building for this study is 30 and of stair passage leading light inspected by two lights in each shopping building is 60. The result of this study is that the type of installed leading lights is LED(77%), and 60% of leading lights has problem such as no cleaning, scratch and discoloration, etc. The height of installed leading lights meets the fire law which is less than 1m from the floor. Visible condition of leading lights is good except some leading lights which have a little visible problem due to banner advertisement. 37% of standby power has flickered and went out. 93% of total leading lights meets the fire law which is more than 1lux from 0.5m distance, but cold cathode fluorescent lamps(CCFLs) have the problem which not meets proper brightness level based on fire law. In additional measurement result, zero lux of leading lights is 32%(from 1m distance), 68%(from 1.5m distance) and 98%(from 2m distance). Leading light is very important facility because it is eyes and guide when emergency. Therefore, proper fire facility operating function inspection and total detailed inspection are important to keep the good condition of leading light except simple visual check, and also improvement in law system of type approval, fire construction inspection and illumination level will be needed.