• Title/Summary/Keyword: Zero rate

Search Result 1,149, Processing Time 0.038 seconds

Effects of the Concentration and the Temperature on the Thermophysical Properties of Purely-Viscous Non-Newtonian Fluid (순수점성 비뉴톤유체의 물성치들에 대한 농도 및 온도의 영향)

  • 조금남
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.670-680
    • /
    • 1994
  • The thermophysical properties of Non-Newtonian fluid as the function of the temperature and the concentration are needed in many rheological heat transfer and fluid mechanics problems. The present work investigated the effects of the concentration and the temperature on the thermophysical properties of purely-viscous Non-Newtonian fluids such as the isobaric thermal expansion coefficient, density, zero-shear-rate viscosity, and zero-shear-rate dynamic viscosity within the experimental temperature range from $25^{\circ}C$ to $55^{\circ}C$. The densities of the test fluids were determined as the function of the temperature by utilizing a reference density and the least square equation for the measured isobaric thermal expansion coefficient. As the concentration of purely-viscous Non-Newtonian fluid was increased up to 10,000 wppm, the densities were proportionally increased up to 0.4%. The zero-shear-rate viscosities of test fluids were measured before and after the measurements of the first thermal expansion coefficients and the densities of Non-Newtonian fluid. Even though they were changed up to approximately 22% due to thermal aging and cycling, they had no effects on the thermal expansion coefficients and the densities of Non-Newtonian fluid. The zero-shear-rate dynamic viscosities for purely-viscous Non-Newtonian fluids were compared with the values for distilled water. They showed the similar trend with the zero-shear-rate viscosities due to small differences in the densities for both distilled water and purely-viscous Non-Newtonian fluid.

A Study on the Real Time Processing Technique of speech Signal (음성신호의 실시간 처리기법에 관한 연구)

  • Lee, Taek-Soo;Rhn, Chang;Kim, Sung-Nak;Rhee, Sang-Burm
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1094-1096
    • /
    • 1987
  • Zero-crossing analysis techniques have been applied to speech recognition. Zero-crossing rate, level-crossing rate and differentiated zero-crossing rate in time domain we used in analyzing speech signals. Speech samples could be stored in memory buffer in real time.

  • PDF

Reduction Characteristics of Triclosan using Zero-valent Iron and Modified Zero-valent Iron (영가철 및 개질 영가철을 이용한 triclosan의 환원분해 특성)

  • Choi, Jeong-Hak;Kim, Young-Hun
    • Journal of Environmental Science International
    • /
    • v.26 no.7
    • /
    • pp.859-868
    • /
    • 2017
  • In this study, the reductive dechlorination of triclosan using zero-valent iron (ZVI, $Fe^0$) and modified zero-valent iron (i.e., acid-washed iron (Aw/Fe) and palladium-coated iron (Pd/Fe)) was experimentally investigated, and the reduction characteristics were evaluated by analyzing the reaction kinetics. Triclosan could be reductively decomposed using zero-valent iron. The degradation rates of triclosan were about 50% and 67% when $Fe^0$ and Aw/Fe were used as reductants, respectively, after 8 h of reaction. For the Pd/Fe system, the degradation rate was about 57% after 1 h of reaction. Thus, Pd/Fe exhibited remarkable performance in the reductive degradation of triclosan. Several dechlorinated intermediates were predicted by GC-MS spectrum, and 2-phenoxyphenol was detected as the by-product of the decomposition reaction of triclosan, indicating that reductive dechlorination occurred continuously. As the reaction proceeded, the pH of the solution increased steadily; the pH increase for the Pd/Fe system was smaller than that for the $Fe^0$ and Aw/Fe system. Further, zero-order, first-order, and second-order kinetic models were used to analyze the reaction kinetics. The first-order kinetic model was found to be the best with good correlation for the $Fe^0$ and Aw/Fe system. However, for the Pd/Fe system, the experimental data were evaluated to be well fitted to the second-order kinetic model. The reaction rate constants (k) were in the order of Pd/Fe > Aw/Fe > $Fe^0$, with the rate constant of Pd/Fe being much higher than that of the other two reductants.

Analysis of bivariate recurrent event data with zero inflation

  • Kim, Taeun;Kim, Yang-Jin
    • Communications for Statistical Applications and Methods
    • /
    • v.27 no.1
    • /
    • pp.37-46
    • /
    • 2020
  • Recurrent event data frequently occur in clinical studies, demography, engineering reliability and so on (Cook and Lawless, The Statistical Analysis of Recurrent Events, Springer, 2007). Sometimes, two or more different but related type of recurrent events may occur simultaneously. In this study, our interest is to estimate the covariate effect on bivariate recurrent event times with zero inflations. Such zero inflation can be related with susceptibility. In the context of bivariate recurrent event data, furthermore, such susceptibilities may be different according to the type of event. We propose a joint model including both two intensity functions and two cure rate functions. Bivariate frailty effects are adopted to model the correlation between recurrent events. Parameter estimates are obtained by maximizing the likelihood derived under a piecewise constant hazard assumption. According to simulation results, the proposed method brings unbiased estimates while the model ignoring cure rate models gives underestimated covariate effects and overestimated variance estimates. We apply the proposed method to a set of bivariate recurrent infection data in a study of child patients with leukemia.

All-Optical Bit-Rate Flexible NRZ-to-RZ Conversion Using an SOA-Loop Mirror and a CW Holding Beam

  • Lee, Hyuek Jae
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.464-469
    • /
    • 2016
  • All-optical non-return-to-zero (NRZ) -to- return-to-zero (RZ) data-format conversion has been successfully demonstrated using a semiconductor optical amplifier in a fiber-loop mirror (so-called SOA-loop mirror) with a continuous-wave (CW) holding beam. The converted RZ signal after pulse compression has been used to create a 40 Gb/s OTDM (Optical Time Division Multiplexing) signal. Here is proposed an NRZ-to-RZ conversion method without any additional optical clocks, unlike conventional methods based on optical AND logic. In addition, it has the merit of operating at various bit-rate speeds without any controlling device. Moreover, it has a simple structure, and it can be used for all-optical bit-rate-flexible clock recovery.

Innovative Approaches to Increase the Longevity of PRBs Containing Zero-Valent Iron

  • 이태윤;박재우;최은경;허보연
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.122-124
    • /
    • 2002
  • The removal capacity of zero-valent iron for Cr(Ⅵ) was evaluated using batch kinetic tests. The rate constants for zero-valent iron dramatically increased as initial Cr(Ⅵ) concentration decreased. Generally, the reaction rates of Cr(Ⅵ) with zero-valent iron were faster than that of a biotic degradation of Cr(Ⅵ), and furthermore the reaction rates were inversely proportional to the initial Cr(Ⅵ) concentrations. After certain reaction time elapsed. no further decrease of Cr(Ⅵ) was observed, indicating a loss of iron reactivity. The loss of iron reactivity was primarily due to the passivation of iron surfaces with iron-Cr precipitates, but the reactivity of iron was recovered by adding iron-reducing bacteria. Even though the addition of bacteria itself removed Cr(Ⅵ), the combination of iron-reducing bactera and oxidized iron significantly enhanced the reaction rate for Cr(Ⅵ) removal. The results from column tests also confirmed that the innoculation of iron-reducing bacteria to the column containing completely oxidized iron partially enhanced the recovery of the iron reactivity.

  • PDF

A Study on the Accident Rate Forecasting and Estimated Zero Accident Time in the Transportation, Storage, and Telecommunication Divisions (운수창고 및 통신업에서의 재해율 예측과 무재해시간 추정에 관한 연구)

  • Kang, Young-Sig;Kim, Tae-Gu
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.47-52
    • /
    • 2010
  • Many industrial accidents have occurred over the years in the manufacturing and construction industries in Korea. However, as the service industry has increased continuously, the share of the accident rate in the service industry was 39.07% in 2009, while the manufacturing industry share was 33.73%. The service industry share overtook the manufacturing industry share for the first time. Therefore, this research considers prevention of industrial accidents in the service industry as well as manufacturing and construction industries. This paper describes a procedure and a method to estimate efficient accident rate forecasting and estimated zero accident time in the service industry in order to prevent industrial accidents in the transportation, storage, and telecommunication divisions. This paper proposes a model using an analytical function for the sake of very efficient accident rate forecasting. Accordingly, this paper has develops a program for accident rate forecasting, zero accident time estimating, and calculation of achievement probability through MFC (Microsoft Foundation Class) software Visual Studio 2008 in the transportation, storage, and telecommunication divisions. In results of this paper, ARIMA (Auto Regressive Integrating Moving Average) is regarded as a very efficient forecasting model for the transportation, storage, and telecommunication division. In testing this model, value minimizing the Sum of Square Errors (SSE) was calculated as 0.2532. Finally the results of this paper are sure to help establish easy accident rate forecasting and strategy or method of zero accident time in the service industry for prevention of industrial accidents.

Dechlorination of PCE Using Zero-Valent Iron and Surfactants (Fe$^{0}$ 과 계면활성제를 이용한 PCE의 탈염소화 반응에 관한 연구)

  • 조현희;박재우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.119-123
    • /
    • 2000
  • In-situ treatment technologies have been proposed to transform or remove pollutants from contaminated groundwater. Zero-valent iron(Fe$^{0}$ ), metallic iron, is being evaluated as a permeable reactive material to retard the transport of wide array of highly mobile contaminants in groundwater. In this research, tetrachloroethylene(PCE) dechlorination by powdered zero-valent iron in buffered aqueous solution was studied with and without the presence of surfactants. The rate of dechlorination of PCE by zero-valent iron with surfactant was much higher than without surfactant. The presence of surfactant increased the apparent rate of dechlorination because the surfactants influenced the dissolution of PCE into the aqueous phase.

  • PDF

A Study of Zero Energy Building Verification with Measuring and Model-based Simulation in Exhibition Building

  • Ha, Ju-wan;Park, Kyung-soon;Kim, Hwan-yong;Song, Young-hak
    • Architectural research
    • /
    • v.20 no.3
    • /
    • pp.93-102
    • /
    • 2018
  • With the change in Earth's ecosystems due to climate change, a number of studies on zero energy buildings have been conducted globally, due to the depletion of energy and resources. However, most studies have concentrated on residential and office buildings and the performance predictions were made only in the design phase. This study verifies the zero-energy performance in the operational phase by acquiring and analyzing data after the completion of an exhibition building. This building was a retention building, in which a renewable energy system using a passive house building envelope, solar photovoltaic power generation panels, as well as fuel cells were adopted to minimize the maintenance cost for future energy-zero operations. In addition, the energy performance of the building was predicted through prior simulations, and this was compared with actual measured values to evaluate the energy performance of the actual operational records quantitatively. The energy independence rate during the measurement period of the target building was 123% and the carbon reduction due to the energy production on the site was 408.07 tons. The carbon reduction exceeded the carbon emission (331.5 tons), which verified the carbon zero and zero-energy performances.

MIMO-FTN Transceiver Structure Using W-ZF Method (W-ZF 기법을 이용한 MIMO-FTN 송수신 구조 연구)

  • Seo, Jung-hyun;Jung, Ji-won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.7
    • /
    • pp.1291-1298
    • /
    • 2017
  • In this paper, we propose a decoding method that improves the transmission rate and reliability by integrating MIMO(Multiple Input Multiple Output) communication scheme using turbo code and FTN(Faster Than Nyquist) scheme among high rate and high reliability wireless communication schemes in wireless communication. The existing MIMO-FTN(Multiple Input Multiple Output-Faster Than Nyquist) scheme based on hierarchical space-time coded method induced data rate loss due to the application of the space-time trellis coding scheme to remove adjacent symbol interference due to FTN scheme. To solve these problems, this paper proposes a method using W-ZF(Weighted-Zero Forcing) which overcomes the disadvantages of ZF(Zero Forcing) scheme in MIMO-FTN scheme using ZF scheme. In this paper, we compared the performance and the transmission rate of the MIMO-FTN scheme based on the hierarchical space-time coding, the MIMO-FTN scheme using W-ZF and the SISO-FTN scheme. As a result, the MIMO-FTN scheme using the W-ZF scheme is two times better than the other two schemes.