• Title/Summary/Keyword: Zero If

Search Result 698, Processing Time 0.028 seconds

Evaluation of Characteristics of Particle Composition and Pollution of Heavy Metals for Bottom Sediments in Cheonsu Bay, Korea -Comparison of the Sediments Environment of Farming Area and Non-farming Area (천수만 해저 퇴적물의 입도특성 및 중금속 오염도 평가 -어장해역과 비어장해역의 퇴적환경 비교-)

  • Kim, Jong-Gu;Jang, Hyo-Sang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.4
    • /
    • pp.358-371
    • /
    • 2014
  • For the systematic scientific management in Cheonsu Bay of Korea, this study was conducedt to survey the particle composition, organic matter(I.L.) and heavy metals in farming and non-farming areas. The sediment of study area showed feature mixed property by sand, silt and clay. The farming area showed superior by fine-grained sediment, non-farming area showed superior by coarse-grained sediment. The organic pollution of farming area were appeared to be heavily polluted more than non-farming area. The concentration of total nitorgen in sediment was higher farming area than non-farming area. Also, in the case of heavy metals pollution in sediments, farming area was higher than non-farming area. The correlation analysis among to heavy metals, organic matter and particle size was found to have a good interrelationship. For evaluation of heavy metals pollution of sediments, three criteria are applied, Enrichment Factor(EF), Geoaccumulation index(Igeo) and NOAA criteria for sediment. In the case of EF, Heavy metals pollution was appeared to artificial effect all heavy metals if except Cu. In the case of Geoaccumulation index, Cu, Al, Pb was shown zero grade, that is non polluted group, and Cd, Hg, Cr was shown to 0~1 grade, that is mid polluted group, As was shown to 2 grade, that is moderately polluted group. In the case of NOAA, pollution levels of heavy metals except Cd belonged to a group of ERL(Effect range low)~ERM(Effect range median).

Statics corrections for shallow seismic refraction data (천부 굴절법 탄성파 탐사 자료의 정보정)

  • Palmer Derecke;Nikrouz Ramin;Spyrou Andreur
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.7-17
    • /
    • 2005
  • The determination of seismic velocities in refractors for near-surface seismic refraction investigations is an ill-posed problem. Small variations in the computed time parameters can result in quite large lateral variations in the derived velocities, which are often artefacts of the inversion algorithms. Such artefacts are usually not recognized or corrected with forward modelling. Therefore, if detailed refractor models are sought with model based inversion, then detailed starting models are required. The usual source of artefacts in seismic velocities is irregular refractors. Under most circumstances, the variable migration of the generalized reciprocal method (GRM) is able to accommodate irregular interfaces and generate detailed starting models of the refractor. However, where the very-near-surface environment of the Earth is also irregular, the efficacy of the GRM is reduced, and weathering corrections can be necessary. Standard methods for correcting for surface irregularities are usually not practical where the very-near-surface irregularities are of limited lateral extent. In such circumstances, the GRM smoothing statics method (SSM) is a simple and robust approach, which can facilitate more-accurate estimates of refractor velocities. The GRM SSM generates a smoothing 'statics' correction by subtracting an average of the time-depths computed with a range of XY values from the time-depths computed with a zero XY value (where the XY value is the separation between the receivers used to compute the time-depth). The time-depths to the deeper target refractors do not vary greatly with varying XY values, and therefore an average is much the same as the optimum value. However, the time-depths for the very-near-surface irregularities migrate laterally with increasing XY values and they are substantially reduced with the averaging process. As a result, the time-depth profile averaged over a range of XY values is effectively corrected for the near-surface irregularities. In addition, the time-depths computed with a Bero XY value are the sum of both the near-surface effects and the time-depths to the target refractor. Therefore, their subtraction generates an approximate 'statics' correction, which in turn, is subtracted from the traveltimes The GRM SSM is essentially a smoothing procedure, rather than a deterministic weathering correction approach, and it is most effective with near-surface irregularities of quite limited lateral extent. Model and case studies demonstrate that the GRM SSM substantially improves the reliability in determining detailed seismic velocities in irregular refractors.

A Comparison Study of Alum Sludge and Ferric Hydroxide Based Adsorbents for Arsenic Adsorption from Mine Water (알럼 및 철수산화물 흡착제의 광산배수 내 비소 흡착성능 비교연구)

  • Choi, Kung-Won;Park, Seong-Sook;Kang, Chan-Ung;Lee, Joon Hak;Kim, Sun Joon
    • Economic and Environmental Geology
    • /
    • v.54 no.6
    • /
    • pp.689-698
    • /
    • 2021
  • Since the mine reclamation scheme was implemented from 2007 in Korea, various remediation programs have been decontaminated the pollution associated with mining and 254 mines were managed to reclamation from 2011 to 2015. However, as the total amount of contaminated mine drainage has been increased due to the discovery of potential hazards and contaminated zone, more efficient and economical treatment technology is required. Therefore, in this study, the adsorption properties of arsenic was evaluated according to the adsorbents which were derived from water treatment sludge(Alum based adsorbent, ABA-500) and granular ferric hydroxide(GFH), already commercialized. The alum sludge and GFH adsorbents consisted of aluminum, silica materials and amorphous iron hydroxide, respectively. The point of zero charge of ABA-500 and GFH were 5.27 and 6.72, respectively. The result of the analysis of BET revealed that the specific surface area of GFH(257 m2·g-1) was larger than ABA-500(126~136 m2·g-1) and all the adsorbents were mesoporous materials inferred from N2 adsorption-desorption isotherm. The adsorption capacity of adsorbents was compared with the batch experiments that were performed at different reaction times, pH, temperature and initial concentrations of arsenic. As a result of kinetic study, it was confirmed that arsenic was adsorbed rapidly in the order of GFH, ABA-500(granule) and ABA-500(3mm). The adsorption kinetics were fitted to the pseudo-second-order kinetic model for all three adsorbents. The amount of adsorbed arsenic was increased with low pH and high temperature regardless of adsorbents. When the adsorbents reacted at different initial concentrations of arsenic in an hour, ABA-500(granule) and GFH could remove the arsenic below the standard of drinking water if the concentration was below 0.2 mg·g-1 and 1 mg·g-1, respectively. The results suggested that the ABA-500(granule), a low-cost adsorbent, had the potential to field application at low contaminated mine drainage.

Radioimmunoassay Reagent Survey and Evaluation (검사별 radioimmunoassay시약 조사 및 비교실험)

  • Kim, Ji-Na;An, Jae-seok;Jeon, Young-woo;Yoon, Sang-hyuk;Kim, Yoon-cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.34-40
    • /
    • 2021
  • Purpose If a new test is introduced or reagents are changed in the laboratory of a medical institution, the characteristics of the test should be analyzed according to the procedure and the assessment of reagents should be made. However, several necessary conditions must be met to perform all required comparative evaluations, first enough samples should be prepared for each test, and secondly, various reagents applicable to the comparative evaluations must be supplied. Even if enough comparative evaluations have been done, there is a limit to the fact that the data variation for the new reagent represents the overall patient data variation, The fact puts a burden on the laboratory to the change the reagent. Due to these various difficulties, reagent changes in the laboratory are limited. In order to introduce a competitive bid, the institute conducted a full investigation of Radioimmunoassay(RIA) reagents for each test and established the range of reagents available in the laboratory through comparative evaluations. We wanted to share this process. Materials and Methods There are 20 items of tests conducted in our laboratory except for consignment tests. For each test, RIA reagents that can be used were fully investigated with the reference to external quality control report. and the manuals for each reagent were obtained. Each reagent was checked for the manual to check the test method, Incubation time, sample volume needed for the test. After that, the primary selection was made according to whether it was available in this laboratory. The primary selected reagents were supplied with 2kits based on 100tests, and the data correlation test, sensitivity measurement, recovery rate measurement, and dilution test were conducted. The secondary selection was performed according to the results of the comparative evaluation. The reagents that passed the primary and secondary selections were submitted to the competitive bidding list. In the case of reagent is designated as a singular, we submitted a explanatory statement with the data obtained during the primary and secondary selection processes. Results Excluded from the primary selection was the case where TAT was expected to be delayed at the moment, and it was impossible to apply to our equipment due to the large volume of reagents used during the test. In the primary selection, there were five items which only one reagent was available.(squamous cell carcinoma Ag(SCC Ag), β-human chorionic gonadotropin(β-HCG), vitamin B12, folate, free testosterone), two reagents were available(CA19-9, CA125, CA72-4, ferritin, thyroglobulin antibody(TG Ab), microsomal antibody(Mic Ab), thyroid stimulating hormone-receptor-antibody(TSH-R-Ab), calcitonin), three reagents were available (triiodothyronine(T3), Tree T3, Free T4, TSH, intact parathyroid hormone(intact PTH)) and four reagents were available are carcinoembryonic antigen(CEA), TG. In the secondary selection, there were eight items which only one reagent was available.(ferritin, TG, CA19-9, SCC, β-HCG, vitaminB12, folate, free testosterone), two reagents were available(TG Ab, Mic Ab, TSH-R-Ab, CA125, CA72-4, intact PTH, calcitonin), three reagents were available(T3, Tree T3, Free T4, TSH, CEA). Reasons excluded from the secondary selection were the lack of reagent supply for comparative evaluations, the problems with data reproducibility, and the inability to accept data variations. The most problematic part of comparative evaluations was sample collection. It didn't matter if the number of samples requested was large and the capacity needed for the test was small. It was difficult to collect various concentration samples in the case of a small number of tests(100 cases per month or less), and it was difficult to conduct a recovery rate test in the case of a relatively large volume of samples required for a single test(more than 100 uL). In addition, the lack of dilution solution or standard zero material for sensitivity measurement or dilution tests was one of the problems. Conclusion Comparative evaluation for changing test reagents require appropriate preparation time to collect diverse and sufficient samples. In addition, setting the total sample volume and reagent volume range required for comparative evaluations, depending on the sample volume and reagent volume required for one test, will reduce the burden of sample collection and planning for each comparative evaluation.

APPLICATION OF FUZZY SET THEORY IN SAFEGUARDS

  • Fattah, A.;Nishiwaki, Y.
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1051-1054
    • /
    • 1993
  • The International Atomic Energy Agency's Statute in Article III.A.5 allows it“to establish and administer safeguards designed to ensure that special fissionable and other materials, services, equipment, facilities and information made available by the Agency or at its request or under its supervision or control are not used in such a way as to further any military purpose; and to apply safeguards, at the request of the parties, to any bilateral or multilateral arrangement, or at the request of a State, to any of that State's activities in the field of atomic energy”. Safeguards are essentially a technical means of verifying the fulfilment of political obligations undertaken by States and given a legal force in international agreements relating to the peaceful uses of nuclear energy. The main political objectives are: to assure the international community that States are complying with their non-proliferation and other peaceful undertakings; and to deter (a) the diversion of afeguarded nuclear materials to the production of nuclear explosives or for military purposes and (b) the misuse of safeguarded facilities with the aim of producing unsafeguarded nuclear material. It is clear that no international safeguards system can physically prevent diversion. The IAEA safeguards system is basically a verification measure designed to provide assurance in those cases in which diversion has not occurred. Verification is accomplished by two basic means: material accountancy and containment and surveillance measures. Nuclear material accountancy is the fundamental IAEA safeguards mechanism, while containment and surveillance serve as important complementary measures. Material accountancy refers to a collection of measurements and other determinations which enable the State and the Agency to maintain a current picture of the location and movement of nuclear material into and out of material balance areas, i. e. areas where all material entering or leaving is measurab e. A containment measure is one that is designed by taking advantage of structural characteristics, such as containers, tanks or pipes, etc. To establish the physical integrity of an area or item by preventing the undetected movement of nuclear material or equipment. Such measures involve the application of tamper-indicating or surveillance devices. Surveillance refers to both human and instrumental observation aimed at indicating the movement of nuclear material. The verification process consists of three over-lapping elements: (a) Provision by the State of information such as - design information describing nuclear installations; - accounting reports listing nuclear material inventories, receipts and shipments; - documents amplifying and clarifying reports, as applicable; - notification of international transfers of nuclear material. (b) Collection by the IAEA of information through inspection activities such as - verification of design information - examination of records and repo ts - measurement of nuclear material - examination of containment and surveillance measures - follow-up activities in case of unusual findings. (c) Evaluation of the information provided by the State and of that collected by inspectors to determine the completeness, accuracy and validity of the information provided by the State and to resolve any anomalies and discrepancies. To design an effective verification system, one must identify possible ways and means by which nuclear material could be diverted from peaceful uses, including means to conceal such diversions. These theoretical ways and means, which have become known as diversion strategies, are used as one of the basic inputs for the development of safeguards procedures, equipment and instrumentation. For analysis of implementation strategy purposes, it is assumed that non-compliance cannot be excluded a priori and that consequently there is a low but non-zero probability that a diversion could be attempted in all safeguards ituations. An important element of diversion strategies is the identification of various possible diversion paths; the amount, type and location of nuclear material involved, the physical route and conversion of the material that may take place, rate of removal and concealment methods, as appropriate. With regard to the physical route and conversion of nuclear material the following main categories may be considered: - unreported removal of nuclear material from an installation or during transit - unreported introduction of nuclear material into an installation - unreported transfer of nuclear material from one material balance area to another - unreported production of nuclear material, e. g. enrichment of uranium or production of plutonium - undeclared uses of the material within the installation. With respect to the amount of nuclear material that might be diverted in a given time (the diversion rate), the continuum between the following two limiting cases is cons dered: - one significant quantity or more in a short time, often known as abrupt diversion; and - one significant quantity or more per year, for example, by accumulation of smaller amounts each time to add up to a significant quantity over a period of one year, often called protracted diversion. Concealment methods may include: - restriction of access of inspectors - falsification of records, reports and other material balance areas - replacement of nuclear material, e. g. use of dummy objects - falsification of measurements or of their evaluation - interference with IAEA installed equipment.As a result of diversion and its concealment or other actions, anomalies will occur. All reasonable diversion routes, scenarios/strategies and concealment methods have to be taken into account in designing safeguards implementation strategies so as to provide sufficient opportunities for the IAEA to observe such anomalies. The safeguards approach for each facility will make a different use of these procedures, equipment and instrumentation according to the various diversion strategies which could be applicable to that facility and according to the detection and inspection goals which are applied. Postulated pathways sets of scenarios comprise those elements of diversion strategies which might be carried out at a facility or across a State's fuel cycle with declared or undeclared activities. All such factors, however, contain a degree of fuzziness that need a human judgment to make the ultimate conclusion that all material is being used for peaceful purposes. Safeguards has been traditionally based on verification of declared material and facilities using material accountancy as a fundamental measure. The strength of material accountancy is based on the fact that it allows to detect any diversion independent of the diversion route taken. Material accountancy detects a diversion after it actually happened and thus is powerless to physically prevent it and can only deter by the risk of early detection any contemplation by State authorities to carry out a diversion. Recently the IAEA has been faced with new challenges. To deal with these, various measures are being reconsidered to strengthen the safeguards system such as enhanced assessment of the completeness of the State's initial declaration of nuclear material and installations under its jurisdiction enhanced monitoring and analysis of open information and analysis of open information that may indicate inconsistencies with the State's safeguards obligations. Precise information vital for such enhanced assessments and analyses is normally not available or, if available, difficult and expensive collection of information would be necessary. Above all, realistic appraisal of truth needs sound human judgment.

  • PDF

A Study on the Treatment of Combine Electron Beam in the Treatment of Breast Cancer Tumor Bed (유방암 Tumor bed 치료 시 혼합 전자선 치료 방법에 대한 고찰)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.51-56
    • /
    • 2019
  • Purpose: The usefulness of using single-electron radiation for secondary radiotherapy of breast cancer patients after surgery is assessed and the use of a combine of different energy. Methods and materials : In this study, 40 patients (group A) using energy 6 MeV and 9 MeV, and 19 patients (group B) using a combine of 9 MeV and 12 MeV were studied among 59 patients who performed secondary care using combine electronic radiation. Each patient in each group, 6 MeV, 9 MeV, Combine(6 MeV / 9 MeV) and 9 MeV, 12 MeV, Combine (9 MeV / 12 MeV) were developed in different ways, and the maximum doses delivered to the original hospital, D95, D5, and $V_3$, $V_5$, $V_{10}$ were compared. Result: The D95 mean value of Group A treatment plan was $785.33{\pm}225.37cGy$, $1121.79{\pm}87.02cGy$ at 9 MeV, and $1010.98{\pm}111.17cGy$ at 6 MeV / 9 MeV, and the mean value at 6 MeV / 9 MeV was most appropriate for the dose. The mean values of the low dose area $V_3$ and $V_5$ in the lung of the breast direction being treated were $3.24{\pm}3.49%$ and $0.72{\pm}1.55%$ at 6 MeV, the highest 9 MeV at $7.25{\pm}4.59%$, $3.07{\pm}2.64%$, the lowest at 6 MeV. Maximum and average lung dose was $727.78{\pm}137.27cGy$ at 6 MeV / 9 MeV, $49.16{\pm}24.44cGy$, highest 9 MeV at $998.97{\pm}114.35cGy$, $85.33{\pm}41.18cGy$, and lowest 6 MeV at $387.78{\pm}208.88cGy$, $9.27{\pm}6.60cGy$. The value of $V_{10}$ was all close to zero. Group B appeared in the pattern of Group A. Conclusion: Relative differences in low-dose areas of the lungs $V_3$ and $V_5$ were seen and were most effective in the dose transfer of tumor bed in the application of combined energy. It is thought that the method of using electronic energy in further radiation treatments for breast cancer is a more effective way to use the energy effect of limiting energy resources, and that if you think about it again, it could be a little more beneficial radiation treatment for patients.

Problems in the Korean National Family Planning Program (한국가족계획사업(韓國家族計劃事業)의 문제점(問題點))

  • Hong, Jong-Kwan
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.2 no.2
    • /
    • pp.27-36
    • /
    • 1975
  • The success of the family planning program in Korea is reflected in the decrease in the growth rate from 3.0% in 1962 to 2.0% in 1971, and in the decrease in the fertility rate from 43/1,000 in 1960 to 29/1,000 in 1970. However, it would be erroneous to attribute these reductions entirely to the family planning program. Other socio-economic factors, such as the increasing age at marriage and the increasing use of induced abortions, definitely had an impact on the lowered growth and fertility rate. Despite the relative success of the program to data in meeting its goals, there is no room for complacency. Meeting the goal of a further reduction in the population growth rate to 1.3% by 1981 is a much more difficult task than any one faced in the past. Not only must fertility be lowered further, but the size of the target population itself will expand tremendously in the late seventies; due to the post-war baby boom of the 1950's reaching reproductive ages. Furthermore, it is doubtful that the age at marriage will continue to rise as in the past or that the incidence of induced abortion will continue to increase. Consequently, future reductions in fertility will be more dependent on the performance of the national family planning program, with less assistance from these non-program factors. This paper will describe various approaches to help to the solution of these current problems. 1. PRACTICE RATE IN FAMILY PLANNING In 1973, the attitude (approval) and knowledge rates were quite high; 94% and 98% respectively. But a large gap exists between that and the actual practice rate, which is only 3695. Two factors must be considered in attempting to close the KAP-gap. The first is to change social norms, which still favor a larger family, increasing the practice rate cannot be done very quickly. The second point to consider is that the family planning program has not yet reached all the eligible women. A 1973 study determineded that a large portion, 3096 in fact, of all eligible women do not want more children, but are not practicing family planning. Thus, future efforts to help close the KAP-gap must focus attention and services on this important large group of potential acceptors. 2. CONTINUATION RATES Dissatisfaction with the loop and pill has resulted in high discontinuation rates. For example, a 1973 survey revealed that within the first six months initial loop acceptance. nearly 50% were dropouts, and that within the first four months of inital pill acceptance. nearly 50% were dropouts. These discontinuation rates have risen over the past few years. The high rate of discontinuance obviously decreases the contraceptive effectiveness. and has resulted in many unwanted births which is directly related to the increase of induced abortions. In the future, the family planning program must emphasize the improved quality of initial and follow-up services. rather than more quantity, in order to insure higher continuation rates and thus more effective contraceptive protection. 3. INDUCED ABORTION As noted earlier. the use of induced abortions has been increase yearly. For example, in 1960, the average number of abortions was 0.6 abortions per women in the 15-44 age range. By 1970. that had increased to 2 abortions per women. In 1966. 13% of all women between 15-44 had experienced at least one abortion. By 1971, that figure jumped to 28%. In 1973 alone, the total number of abortions was 400,000. Besides the ever incre.sing number of induced abortions, another change has that those who use abortions have shifted since 1965 to include- not. only the middle class, but also rural and low-income women. In the future. in response to the demand for abortion services among rural and low-income w~men, the government must provide and support abortion services for these women as a part of the national family planning program. 4. TARGET SYSTIi:M Since 1962, the nationwide target system has been used to set a target for each method, and the target number of acceptors is then apportioned out to various sub-areas according to the number of eligible couples in each area. Because these targets are set without consideration for demographic factors, particular tastes, prejudices, and previous patterns of acceptance in the area, a high discontinuation rate for all methods and a high wastage rate for the oral pill and condom results. In the future. to alleviate these problems of the methodbased target system. an alternative. such as the weighted-credit system, should be adopted on a nation wide basis. In this system. each contraceptive method is. assigned a specific number of points based upon the couple-years of protection (CYP) provided by the method. and no specific targets for each method are given. 5. INCREASE OF STERILIZA.TION TARGET Two special projects. the hospital-based family planning program and the armed forces program, has greatly contributed to the increasing acceptance in female and male sterilization respectively. From January-September 1974, 28,773 sterilizations were performed. During the same time in 1975, 46,894 were performed; a 63% increase. If this trend continues, by the end of 1975. approximately 70,000 sterilizations will have been performed. Sterilization is a much better method than both the loop and pill, in terms of more effective contraceptive protection and the almost zero dropout rate. In the future, the. family planning program should continue to stress the special programs which make more sterilizations possible. In particular, it should seek to add the laparoscope techniques to facilitate female sterilization acceptance rates. 6. INCREASE NUMBER OF PRIVATE ACCEPTORS Among the current family planning users, approximately 1/3 are in the private sector and thus do not- require government subsidy. The number of private acceptors increases with increasing urbanization and economic growth. To speed this process, the government initiated the special hospital based family planning program which is utilized mostly by the private sector. However, in the future, to further hasten the increase of private acceptors, the government should encourage doctors in private practice to provide family planning services, and provide the contraceptive supplies. This way, those do utilize the private medical system will also be able to receive family planning services and pay for it. Another means of increasing the number of private acceptors, IS to greatly expand the commercial outlets for pills and condoms beyond the existing service points of drugstores, hospitals, and health centers. 7. IE&C PROGRAM The current preferred family size is nearly twice as high as needed to achieve a stable poplation. Also, a strong boy preference hinders a small family size as nearly all couples fuel they must have at least one or more sons. The IE&C program must, in the future, strive to emphasize the values of the small family and equality of the sexes. A second problem for the IE&C program to work. with in the: future is the large group of people who approves family planning, want no more children, but do not practice. The IE&C program must work to motivate these people to accept family planning And finally, for those who already practice, an IE&C program in the future must stress continuation of use. The IE&C campaign, to insure highest effectiveness, should be based on a detailed factor analysis of contraceptive discontinuance. In conclusion, Korea faces a serious unfavorable sociodemographic situation- in the future unless the population growth rate can be curtailed. And in the future, the decrease in fertility will depend solely on the family planning program, as the effect of other socio-economic factors has already been maximumally felt. A second serious factor to consider is the increasing number of eligible women due to the 1950's baby boom. Thus, to meet these challenges, the program target must be increased and the program must improve the effectiveness of its current activities and develop new programs.

  • PDF

Studies on Sclerotium rolfsii Sacc. isolated from Magnolia kobus DC. in Korea (목련(Magnolia kobus DC.)에서 분리한 흰비단병균(Sclerotium rolfsii Sacc.)에 관한 연구)

  • Kim Kichung
    • Korean journal of applied entomology
    • /
    • v.13 no.3 s.20
    • /
    • pp.105-133
    • /
    • 1974
  • The present study is an attempt to solve the basic problems involved in the control of the Sclerotium disease. The biologic stranis of Sclerotium rolfsii Sacc., pathogen of Sclerotium disease of Magnolia kobus, were differentiated, and the effects of vitamins, various nitrogen and carbon sources on its mycelial growth and sclerotial production have been investigated. In addition the relationship between the cultural filtrate of Penicillium sp. and the growth of Sclerotium rolfsii, the tolerance of its mycelia or sclerotia to moist heat or drought and to Benlate (methyl-(butylcarbamoy 1)-2-benzimidazole carbamate), Tachigaren (3-hydroxy-5-methylisoxazole) and other chemicals were also clarified. The results are summarizee as follows: 1. There were two biologic strains, Type-l and Type-2 among isolates. They differed from each other in the mode of growth and colonial appearance on the media, aversion phenomenon and in their pathogenicity. These two types had similar pathogenicity to the Magnolia kobus and Robinia pseudoacasia, but behaved somewhat differently to the soybaen and cucumber, the Type-l being more virulent. 2. Except potassium nitrite, sodium nitrite and glycine, all of the 12 nitrogen sources tested were utilized for the mycelial growth and sclerotial production of this fungus when 10r/l of thiamine hydrochloride was added in the culture solution. Considering the forms of nitrogen, ammonium nitrogen was more available than nitrate nitrogen for the growth of mycelia, but nitrate nitrogen was better for sclerotia formation. Organic nitrogen showed different availabilities according to compounds used. While nitrite nitrogen was unavailable for both mycelial growth and sclerotial formation whether thiamine hydrochlioride was added or not. 3. Seven kinds of carbon sources examined were not effective in general, as long as thiamine hydrochloride was not added. When thiamine hydrochloride was added, glucose and saccharose exhibited mycelial growth, while rnaltose and soluble starch gave lesser, and xylose, lactose, and glycine showed no effect at all,. In the sclerotial production, all the tested carbon sources, except lactose, were effective, and glucose, maltose, saccharose, and soluble starch gave better results. 4. At the same level of nitrogen, the amount of mycelial growth increased as more carbon Sources were applied but decreased with the increase of nitrogen above 0.5g/1. The amount of sclerotial production decreased wi th the increase of carbon sources. 5. Sclerotium rolfsii was thiamine-defficient and required thiamine 20r/l for maximun growth of mycelia. At a higher concentration of more than 20r/l, however, mycelial growth decreased as the concentration increased, and was inhibited at l50r/l to such a degree of thiamine-free. 6. The effect of the nitrogen sources on the mycelial growth under the presence of thiamine were recognized in the decreasing order of $NH_4NO_3,\;(NH_4)_2SO_4,\;asparagine,\;KNO_3$, and their effects on the sclerotial production in the order of $KNO_3,\;NH_4NO_3,\;asparagine,\;(NH_4)_2SO_4$. The optimum concentration of thiamine was about 12r/l in $KNO_3$ and about 16r/l in asparagine for the growth of mycelia; about 8r/l in $KNO_3$ and $NH_4NO_3$, and 16r/l in asparagine for the production of sclerotia. 7. After the fungus started to grow, the pH value of cultural filtrate rapidly dropped to about 3.5. Hereafter, its rate slowed down as the growth amount increased and did not depreciated below pH2.2. 8. The role of thiamine in the growth of the organism was vital. If thiamine was not added, the combination of biotin, pyridoxine, and inositol did not show any effects on the growth of the organism at all. Equivalent or better mycelial growth was recognized in the combination of thiamine+pyridoxine, thiamine+inositol, thiamine+biotin+pyridoxine, and thiamine+biotin+pyridoxine+inositol, as compared with thiamine alone. In the combinations of thiamine+biotin and thiamine+biotin+inositol, mycelial growth was inhibited. Sclerotial production in dry weight increased more in these combinations than in the medium of thiamine alone. 9. The stimulating effects of the Penicillium cultural filtrate on the mycelial growth was noticed. It increased linearly with the increase of filtrate concentration up to 6-15 ml/50ml basal medium solution. 10. $NH_4NO_3$. as a nitrogen source for mycelial growth was more effective than asparasine regardless of the concentration of cultural filtrate. 11. In the series of fractionations of the cultural filtrate, mycelial growth occured in unvolatile, ether insoluble cation-adsorbed or anion-unadsorbed substance fractions among the fractions of volatile, unvolatile acids, ether soluble organic acids, ether insoluble, cation-adsorbed, cation-unadsorbed, anion-adsorbed and anion-unadsorbed. and anion-un-adsorbed substance tested. Sclerotia were produced only in cation-adsorbed fraction. 12. According to the above results, it was assumed that substances for the mycelial growth and sclerotial formation and inhibitor of sclerotial formation were include::! in cultural filtrate and they were quite different from each other. I was further assumed that the former two substances are un volatile, ether insotuble, and adsorbed to cation-exchange resin, but not adsorbed to anion, whereas the latter is unvolatile, ether insoluble, and not adsorbed to cation or anion-exchange resin. 13. Seven amino acids-aspartic acid, cystine, glysine, histidine, Iycine, tyrosine and dinitroaniline-were detected in the fractions adsorbed to cation-exchange resin by applying the paper chromatography improved with DNP-amino acids. 14. Mycelial growth or sclerotial production was not stimulated significantly by separate or combined application of glutamic acid, aspartic acid, cystine, histidine, and glysine. Tyrosine gave the stimulating effect when applied .alone and when combined with other amino acids in some cases. 15. The tolerance of sclerotia to moist heat varied according to their water content, that was, the dried sclerotia are more tolerant than wet ones. The sclerotia harvested directly from the media, both Type-1 and Type-2, lost viability within 5 minutes at $52^{\circ}C$. Sclerotia dried for 155 days at$26^{\circ}C$ had more tolerance: sclerotia of Type-l were killed in 15 mins. at $52^{\circ}C$ and in 5 mins. at $57^{\circ}C$, and sclerotia of Type-2 were killed in 10 mins. both at $52^{\circ}C$ or $57^{\circ}C$. 16. Cultural sclerotia of both strains maintained good germinability for 132 days at$26^{\circ}C$. Natural sclerotia of them stored for 283 days under air dry condition still had good germinability, even for 443 days: type-l and type-2 maintained $20\%$ and $26.9\%$ germinability, respectively. 17. The tolerance to low temperature increased in the order of mycelia, felts and sclerotia. Mycelia completely lost the ability to grow within 1 week at $7-8^{\circ}C$> below zero, while mycelial felts still maintained the viability after .3 weeks at $7-20^{\circ}C$ below zero, and sclerotia were even more tolerant. 18. Sclerotia of type-l and type-2 were killed when dipped into the $0.05\%$ solution of mercury chloride for 180 mins. and 240 mins. respectively: and in the $0.1\%$ solution, Type-l for 60 mins. and Type-2 for 30 mins. In the $0.125\%$ uspulun solution, Type-l sclerotia were killed in 180 mins., and those of Type-2 were killed for 90 mins. in the$0.125\%$solution. Dipping into the $5\%$ copper sulphate solution or $0.2\%$ solution of Ceresan lime or Mercron for 240 mins. failed to kill sclerotia of either Type-l or Type-2. 19. Inhibitory effect on mycelial growth of Benlate or Tachi-garen in the liquid culture increased as the concentration increased. 6 days after application, obvious inhibitory effects were found in all treatments except Benlate 0.5ppm; but after 12 days, distingushed diflerences were shown among the different concentrations. As compared with the control, mycelial growth was inhibited by $66\%$ at 0.5ppm and by $92\%$ at 2.0ppm of Benlate, and by$54\%$ at 1ppm and about $77\%$ at 1.5ppm or 2.0ppm of Tachigaren. The mycelial growth was inhibited completely at 500ppm of both fungicides, and the formation of sclerotia was checked at 1,000ppm of Benlate ant at 500ppm or 1,000ppm of Tachigaren. 20. Consumptions of glucose or ammonium nitrogen in the culture solution usually increased with the increment of mycelial growth, but when Benlate or Tachigaren were applied, consumptions of glucose or ammonium nitrogen were inhibited with the increment of concentration of the fungicides. At the low concentrations of Benlate (0.5ppm or 1ppm), however, ammonium nitrogen consumption was higher than that of the ontrol. 21. The amount of mycelia produced by consuming 1mg of glucose or ammonium nitrogen in the culture solution was lowered markedly by Benlate or Tachigaren. Such effects were the severest on the third day after their treatment in all concentrations, and then gradually recovered with the progress of time. 22. In the sand culture, mycelial growth was not inhibited. It was indirectly estimated by the amount of $CO_2$ evolved at any concentrations, except in the Tachigaren 100mg/g sand in which mycelial growth was inhibited significantly. Sclerotial production was completely depressed in the 10mg/g sand of Benlate or Tachigaren. 23. There was no visible inhibitory effect on the germination of sclerotia when the sclerotia were dipped in the solution 0.1, 1.0, 100, 1.000ppm of Benlate or Tachigaren for 10 minutes or even 20 minutes.

  • PDF