• Title/Summary/Keyword: ZSI

Search Result 44, Processing Time 0.017 seconds

Modified Finite Control Set-Model Predictive Controller (MFCS-MPC) for quasi Z-Source Inverters based on a Current Observer

  • Bakeer, Abualkasim;Ismeil, Mohamed A.;Orabi, Mohamed
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.610-620
    • /
    • 2017
  • The Finite Control Set-Model Predictive Controller (FCS-MPC) for quasi Z-Source Inverters (qZSIs) is designed to reduce the number of sensors by proposing a current observer for the inductor current. Unlike the traditional FCS-MPC algorithm, the proposed model removes the inductor current sensor and observes the inductor current value based on the deposited prior optimized state as well as the capacitor voltage during this state. The proposed observer has been validated versus a typical MPC. Then, a comparative study between the proposed Modified Finite Control Set-Model Predictive Controller (MFCS-MPC) and a linear PID controller is provided under the same operating conditions. This study demonstrates that the dynamic response of the control objectives by MFCS-MPC is faster than that of the PID. On the other hand, the PID controller has a lower Total Harmonic Distortion (THD) when compared to the MFCS-MPC at the same average switching. Experimental results validate both methods using a DSP F28335.

A Single-Phase DC-AC Inverter Using Two Embedded Z-Source Converters (2대의 임베디드 Z-소스 컨버터를 이용한 단상 DC-AC 인버터)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1152-1162
    • /
    • 2011
  • In this paper, a single-phase DC-AC inverter using two embedded Z-source converters is proposed. The proposed inverter is composed of two embedded Z-source converters with common DC source and output AC load. The output AC voltage of the inverter is obtained by the difference of output capacitor voltages of each converter. The output voltage of each converter take shape of the asymmetrical AC waveform centering zero voltage. Therefore, the proposed inverter can generate the same output voltage despite low VA rating L-C elements, compared to the conventional inverter using high DC voltage with AC ripple. To verify the validity of the proposed system, the PSIM simulation was achieved under the condition of rapid increase of DC source (110[V]${\rightarrow}$150[V]) and R-load (50[${\Omega}$]${\rightarrow}$300[${\Omega}$]). For controlling the voltage of the inverter system, the one-cycle controller was adopted. As results, the proposed inverter output the constant AC voltage (220[V]rms/60[Hz]) for all conditions. Also, the R-L load and nonlinear diode load were adopted for the proposed inverter loads, and we could know that the its output voltage characteristics were as good as the pure R-load. Finally, the RMS and THD of output AC voltage were examined for the different loads, input DC voltages and reference voltage signals.

Three-Phase Z-Source Dynamic Voltage Restorer with a Fuel Cells Source (연료전지 전원을 갖는 3상 Z-소스 동적 전압 보상기)

  • Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.41-48
    • /
    • 2008
  • This paper proposes a three-phase Z-source dynamic voltage restorer (Z-DVR) to mitigate the voltage sag for the critical loads. The proposed system is composed of passive filter and Z-source topology inverter. As an ESS(Energy Storage System) of the proposed system is employed the Proton Exchange Membrane Fuel Cells (PEMFC). To calculate and control the harmonics and compensation voltage, $i_{d}-i_{q}$ theory in dq rotating reference frame and PI controller are used. In case that three-phase voltage sags occurred, a PSIM simulation was done for the performance comparison of the conventional method employed battery stacks and proposed method. As a result, considering the voltage compensation performance, each method was nearly similar. Also, the compensation performance and the %THD(%Total Harmonic Distortion) result under the various source voltage conditions (sag or swell) were presented and discussed to show the performance of the proposed system.

Ecological Survey of the Nakdong River Estuary (낙동강 하구 부근의 해양 환경 조사 연구)

  • 박청길
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.4
    • /
    • pp.1-20
    • /
    • 1986
  • Physical, chemical and biological surveys on Nakdong River estuary were made from October, 1985 to September, 1986. 1. For all the seasons except summer, the sea surface temperature in northwest area of the line which linked from Seo Island to Jisim Island was I-2$^{\circ}$C lower than in southeast area, but in summer the sea surface temperature in northwest area was I-2$^{\circ}$C higher than in southeast area. On the contrary, bottom temperature of coastal area was 1$^{\circ}$C higher than that of oceanic area except winter. 2. Surface salinity in summer and fall has minimum value of 1. 9%0 and maximum value of 32.9%0. This large variation was caused by the runoff of the Nakdong River. Effect of less saline Nakdong River water in northwest area of the line which linked from Seo Island to Jisim Island was greater than in southeast area. A strong current rip always formed near this line. 3. The yellowish-green colored zone was observed in the Nakdong River estuary throughout the year by influence of river discharge. The characteristics of the water quality in the zone have shown that the water color was grade 7 by the Forel water-color meter, transparency was less than 4 m, and concentration of suspended solids was more than 5 mg/1. This water body was in the state of eutrophication in terms of chlorophyll-a and inorganic nitrogen concentration during summer season. 4. During the study period, total 276 taxa were identified. Most of them were diatoms and dinoflagellates which consisted of 97.5%. The component ratio of the above two groups was 84.4% and 13.1 % respectively. Diatoms were plentiful in December and dinoflagellates in July. Dominant species were Nitzschia seriata in October, Thalassiosira rotula in December, Skeletoncma costatum in April, and Nitzschia longissima in July. 5. A total of 47 zooplankton taxa was identified from the samples collected. Copepods were numerically the most important components of zooplankton communities in the study area. The domir:ant copepod species were Paracalanus parvus, Acartia clausi and Temora turbinata. Noctiluca scintillans was the next important component. The other zooplankton with minor abundance were Cladocera. Sagitta spp., Cnidaria, Mysidacea, Lucifer spp. and Amphipoda. 6. During the study period, fishes from 47 families and 87 species were sampled in th~ study area. The four most abundant fish species were Rep~mucen//'s valencicnnei, Leiognathus n~cha!is, Amblychaeturicllthys hexanema and Sardirel/a zun:zsi. The fish species of the secondary importance in abundance were Cynoglossus joyneri, Sillago sihama, Engra~lis japonicus, Encdrias nebulos'l, Acanthogobius flavimanus, Trichiurus lepturus, LiParis tanai/ai, Cynagloss//'s interruptus, Aj)ogon line:z!us, Thrissz la 1l.'1la!ensis, and Limanda yokohamac.

  • PDF