Effect of Bead Device Diameter on Z-Resolution Measurement in Tomosynthesis Images: A Simulation Study

  • Ryohei Fukui;Miho Numata;Saki Nishioka;Ryutarou Matsuura;Katsuhiro Kida;Sachiko Goto
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.63-71
    • /
    • 2022
  • Purpose: To clarify the relationship between the diameter of the simulated bead and the Z-resolution of the tomosynthesis image. Methods: A simulated bead was placed on a 1,024×1,024×1,024-pixel base image. The diameters were set to 0.025, 0.05, 0.1, 0.2, 0.3, 0.7, 1.0, and 1.3 mm. A bead was placed at the center of the base image and projected at a simulated X-ray angle range of ±45° to obtain a projected image. A region of interest was placed at the center of the bead image and the slice sensitivity profile (SSP) was obtained by acquiring pixel values in the z-direction. The full width at half maximum of the SSP was defined as the Z-resolution and the frequency response was obtained by the 1-D Fourier transform of the SSP. Results: Z-resolution increased with increasing bead diameter. However, there was no change in Z-resolution between 0.025 and 0.1 mm. The frequency response was similar to that of the Z-resolution, with a significant difference between 0.1 and 0.2 mm diameter. Conclusions: Z-resolution is dependent on the diameter of the bead, which should be selected considering the pixel size of the tomosynthesis image.

Boundary stress resolution and its application to adaptive finite element analysis

  • Deng, Jianhui;Zheng, Hong;Ge, Xiurun
    • Structural Engineering and Mechanics
    • /
    • v.6 no.1
    • /
    • pp.115-124
    • /
    • 1998
  • A novel boundary stress resolution method is suggested in this paper, which is based upon the displacements of finite element analysis and of high precision with stress boundary condition strictly satisfied. The method is used to modify the Zienkiewicz-Zhu ($Z^2$) a posteriori error estimator and for the h-version adaptive finite element analysis of crack problems. Successful results are obtained.

A Study on Shifted Multi-Z-Buffers Anti-Aliasing for 3D Implicit Surface Rendering (3차원 임플리시트 곡면 렌더링을 위한 시프트(shifted) 멀티 Z-버퍼 앤티 앨리어싱 연구)

  • Park Hwa Jin;Kim Hak Ran
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.2
    • /
    • pp.249-257
    • /
    • 2005
  • This paper aims at reducing aliasing in pixel-based rendering for 3D implicit surfaces by shifted multi Z-buffers. The voxelized implicit surfaces with high resolution take so much time in generating high Quality image without aliasing. So in rendering a voxelized implicit surfaces, a new antialiasing method which can generate a high quality image at a lower resolution is required. Therefore, this paper suggests that a method which get various sampling values by shifting several z-buffers in each voxel and average them, The advantages are effective memory, simple calculation and easy convergence with various filters. But, the increase of number of z-buffer also increase the consuming time rapidly. Therefore, the research for representing the relation the degree of image quality with the consumption of time as a number is required.

  • PDF

Experiment of the Precision micro-positioning stage (초정밀 마이크로 위치결정 스테이지의 제작 및 평가)

  • Han, C. S.;Paek, S.;No, M. K.;Lee, C. H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.244-247
    • /
    • 2002
  • The performance of the precision micro-positioning 4-dof stage is presented. The compact design utilizes the monolithic mechanism to achieve the translation in the Z axis and rotation in the $\theta$ z, $\theta$ x and $\theta$ y axes with high stiffness and high damping. Hysteresis, nonlinearity, and drift of the piezoelectric effects are improved by incorporating the sensors in a feedback control. Experiments demonstrate that the micro-positioning stage is capable of 2nm resolution over the travel range of 25$\mu\textrm$ m in the Z axis, 0.0l7 $\mu\textrm$ rad resolution over the 170$\mu\textrm$ rad in the $\theta$ z and 0.011 $\mu\textrm$ rad resolution over the $\mu\textrm$ rad in the $\theta$ x and $\theta$ y axes. The cross-axis interferences among the axes are at a noise range. This stage is available for positioning error compensation of the XY stage with large stroke.

  • PDF

HIGH-RESOLUTION NEAR-INFRARED SPECTRA OF NEARBY QUASARS

  • Le, Huynh Anh Nguyen;Pak, Soojong;Im, Myungshin;Ho, LuisC.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.91-91
    • /
    • 2012
  • We present high-resolution near-infrared host galaxy spectra of low-z quasars, PG0844+349 (z=0.064), PG1226+023 (z=0.158), and PG1426+015 (z=0.086). The observation was done by using the near-IR high resolution echelle spectrometer, IRCS, at the SUBARU 8.2 m telescope. The full width at half maximum of the point spread function was about 0.3 arcsec by using an Adaptive Optics system, which can effectively resolve the quasar spectra from the host galaxy spectra. The signal-to-noise ratios are increased by the total exposure time up to several hours per targets and the development of data reduction method. We compare our results to the stellar spectra library and sample spectra from Dasyra et al. (2007) and Watson et al. (2008). The identified spectral lines will be used to study the physical mechanism of quasars, and the velocity dispersions of the stars in the bulge of the host galaxy.

  • PDF

A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

A Double Z-buffer Antialiasing Method for Voxelized Implicit Surfaces (복셀로 표현된 임플리시트 곡면을 위한 시프트(shifted) 더블 Z-버퍼 앤티 앨리어싱)

  • 김학란;박화진
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.1
    • /
    • pp.44-53
    • /
    • 2004
  • This paper aims at presenting high quality at low resolution apply by a new antialiasing method for voxelized implicit surfaces. Implicit surfaces create a unique type of 3D-modeling. Some use of implicit surfaces are scientific and medical visualization, animation, medical simulation and interactive modeling. One of previous antialiasing methods for implicit surfaces presented by raytracing or texture mapping is making use of a stochastic sampling. But this method requires more calculation time and costs which is caused by complicated and difficult implicit functions. In the meanwhile, voxelized implicit surfaces generally use high resolution for good quality images but it costs to generate. In order to this problem, this paper suggests a shifted double Z-buffer which is very simple, more efficient and easy. Tn addition, there are applied box-filter and tent-filter to the double Z-buffer antialiasing method for better images. For results this method generate high quality image and it is easy to apply to various filters and is able to extend to multi Z-buffer.

  • PDF

Preliminary Study on the Detection of Late Potentials using High-Resolution Electrocardiography (HRECG에 의한 Late Potential의 검출에 관한 예비 연구)

  • Woo, Eung-Je;Park, Seung-Hun
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.63-65
    • /
    • 1993
  • We have done a preliminary study on the detection of ventricular late potentials using high-resolution electrocardiography. We designed a battery powered low-noise ECG amplifier. We used the XYZ lead system and the amplifier provides 3 channels of X, Y, and Z signals with a conventional gain and another 3 channels of the amplitude-limited X, Y, and Z signals with high-gain. 12-bit data acquisition system interfaces the amplifiers to a personal computer for further signal analysis. Beat alignment algorithm was implemented on the low-gain signals to synchronize the signal averaging of the high-gain amplitude-limited signals. We suggest the use of the weighted vector sum of X', Y', and Z' signals based on the SNR of each channel. We speculate that this new method will increase the accuracy of the LP detector at the expense of more complicated hardware.

  • PDF

Crystallographic Characterization of the (Bi, La)4Ti3O12 Film by High-Resolution Electron Microscopy (고분해능 전자현미경법을 이용한 (Bi, La)4Ti3O12 박막의 결정학적 특성 평가)

  • Lee, Doek-Won;Yang, Jun-Mo;Park, Tae-Su;Kim, Nam-Kyung;Yeom, Seung-Jin;Park, Ju-Chul;Lee, Soun-Young;Park, Sung-Wook
    • Korean Journal of Materials Research
    • /
    • v.13 no.7
    • /
    • pp.478-483
    • /
    • 2003
  • The crystallographic characteristics of the $(Bi, La)_4$$Ti_3$$O_{12}$ thin film, which is considered as an applicable dielectrics in the ferroelectric RAM device due to a low crystallization temperature and a good fatigue property, were investigated at the atomic scale by high resolution transmission electron microscopy and the high resolution Z-contrast technique. The analysis showed that a (00c) preferred orientation and a crystallization of the film were enhanced with the diffraction intensity increase of the (006) and (008) plane as the annealing temperature increased. It indicated a change of the atomic arrangement in the (00c) plane. Stacking faults on the (00c) plane were also observed. Through the comparison of the high-resolution Z-contrast image and the $Bi_4$$Ti_3$$O_{12}$ atomic model, it was evaluated that the intensity of the Bi atom was different according to the atomic plane, and it was attributed to a substitution of La atom for Bi at the specific atom position.

Identification of Chromosomal Band Markers of the Korean Native Chicken (한국재래계의 염색체 분염 표지 분석)

  • Baik, K. H.;Lee, C. Y.;Sang, B. D.;Choi, C. H.;Kim, H. K.;Sohn, S. H.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • The present study was carried out to establish the standard karyotype of the Korean Native Chicken and to find their chromosomal band markers using high-resolution banding technique. Chromosome analysis was performed on early chick embryos following in vitro culture of fertilized eggs of the yellow-brown and the red-brown lines of the Korean Native Chicken which had been established at National Livestock Research Institute. The high-resolution banding of the chromosome was achieved by treating the embryos with ethidium bromide and colchicine during culture. On GTG-banding, the Korean Native Chicken exhibited a typical chick banding pattern in all the macrochromosomes. Overall chromosomal morphology and positions of typical landmarks of the Korean Native Chicken were virtually identical to those of White Leghorn and International System for Standardized Avian Karyotypes(ISSAK). However, the lengths and G-band numbers of the Korean Native Chicken macrochromosomes were greater than those of White Leghorn and ISSAK. Especially in chromosomes 1 and Z, the Korean Native Chicken exhibited more separated bands in compared with ISSAK. In C-banding patterns, although a lot of observed cells had C-band polymorphic patterns, almost the Korean Native Chicken macrochromosomes had heterochromatic C-band on centromeres and/or near terminal part. However, the heterochromatic C-band was constantly observed at the end of q-arm of Z chromosomes and on the whole W chromosome. In addition, the Korean Native Chicken exhibited distinctive heteromorphic patterns of C-bands on the centromere of chromosome 3 and at the end of q-arm of Z chromosome between homologous chromosomes.