• Title/Summary/Keyword: Z-축

Search Result 266, Processing Time 0.032 seconds

Comparative Study of CL Z-map Modeling for 3-Axis NC Machining (3축 NC 가공을 위한 CL Z-map 모델링 방법의 비교 연구)

  • Park, Jung-Whan;Chung, Yun-Chan;Choi, Byoung-Kyu
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.4
    • /
    • pp.325-335
    • /
    • 2000
  • Gouge-free tool-path generation is an important issue in mold & die machining and researches on cutter interference avoidance can be found in many articles. One of the various methods is construction of tool-offset surface of cutter-location (CL) surface on which the cutter-center point (CL-point) locates. Provided that the CL surface is represented in a suitable form, cutter-interference avoidance can be performed without the burden of computing CL data for every cutter-contact (CC) point. In the paper, various methods of constructing a CL surface in the z-map form are presented, where z-map is a special form of discrete nonparametric representation in which the height values at grid points on the xy-plane are stored as a 2D array z[i,j].

  • PDF

Comparison of landmark positions between Cone-Beam Computed Tomogram (CBCT) and Adjusted 2D lateral cephalogram (Cone-Beam Computed Tomogram (CBCT)과 Adjusted 2D lateral cephalogram의 계측점 차이에 관한 비교 연구)

  • Son, Soo-Jung;Chun, Youn-Sic;Kim, Minji
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.222-232
    • /
    • 2014
  • Purpose: This study aims to investigate if 2D analysis method is applicable to analysis of CBCT by comparing measuring points of CBCT with those of Adjusted 2D Lateral Cephalogram (Adj-Ceph) with magnification adjusted to 100% and finding out at which landmarks the difference in position appear. Materials and methods: CBCT data and Adj-Ceph (100% magnification) data from 50 adult patients have been extracted as research objects, and the horizontal (Y axis) and vertical (Z axis) coordinates of landmarks were compared. Landmarks have been categorized into 4 groups by the position and whether they are bilaterally overlapped. Paired t-test was used to compare differences between Adj-Ceph and CBCT. Results: Significant difference was found at 11 landmarks including Group B (S, Ar, Ba, PNS), Group C (Po, Or, Hinge axis, Go) and Group D (U1RP, U6CP, L6CP) in the horizontal (Y) axis while all the landmarks in vertical (Z) axis showed significant difference (P<.05). As a result of landmark difference analysis, a meaningful difference with more than 1 mm at 13 landmarks were indentifed in the horizontal axis. In the vertical axis, significant difference over 1 mm was detected from every landmark except Sella. Conclusion: Using the conventional lateral cephalometric measurements on CBCT is insufficient. A new 3D analysis or a modified 2D analysis adjusted on 19 landmarks of the vertical axis and 13 of the horizontal axis are needed when implementing CBCT diagnosis.

Fabrication of the Three Dimensional Accelerometer using Bridge Combination Detection Method (브리지조합 검출방식을 이용한 고온용 3축 가속도센서 제작)

  • Son, Mi-Jung;Seo, Hee-Don
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.196-202
    • /
    • 2000
  • In this paper, we proposed the new bridge combination detection method for three dimensional piezoresistive silicon accelerometer, and the accelerometer with SOI structures was fabricated by bulk micromachining technology for using higher temperature than $200^{\circ}C$. The sensitivities of fabricated accelerometer for X, Y and Z-axis acceleration were about 8mV/V G, 8mV/V G and 40mV/V G. The nonlinearity of the output voltage was 1.6%FS and cross-axis sensitivity was within 4.6%. We confirmed that the three bridges detection method is very simple and the output characteristics of this accelerometer were similar to arithmetic circuit method accelerometer. The temperature characteristics of SOI structure accelerometer showed high operating temperature and good stability. And the temperature coefficient of offset voltage and sensitivity were $1033ppm^{\circ}C^{-1}$ and $1145ppm^{\circ}C$ respectively.

  • PDF

An analysis angular movement and performance time during handspring salto forward stretched (핸드스프링 몸펴 앞공중1회 비틀기 동작의 소요시간 및 각운동량 분석)

  • Kwon, Oh-Seok;Yoon, Yang-Jin;Seo, Kuk-Woong
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.229-244
    • /
    • 2002
  • The purpose of this study were a two-fold: (1) to analyze event and phase of handspring salto forward stretched with turn; (2) to know the differences in the kinematic variables between two groups. A Kwon3D program served for the estimation of this study. The group was divided into three National representative and three well-trained calisthenics in this study. The results of this study revealed that (1) the forward somersault performance was increased when duration time in the air was long during the salto forward stretched that the duration time of Handspring is short, the pressure at takeoff is high, the stride is large, and hands are supporting on the ground quickly; (2) comparing the angular movement of anterior and posterior y axis and vertical z axis, the angular movement of right and left $\times$ axis was higher during the performance. As a result, the national representative players showed better performance in Handspring salto forward stretched with turn.

An Experimental Performance Evaluation with Xenomai for WSN (WSN을 위한 Xenomai의 실험적 성능평가)

  • Son, Tae-Yeong;Rim, Seong-Rak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.709-714
    • /
    • 2017
  • Structures like bridges or buildings need to be checked continuously to diagnose their safety. However, it is extremely difficult for the people who access such structures to check all areas directly. To overcome this problem, there is a lot of active research into structural health monitoring (SHM) with wireless sensor nodes (WSNs). In this paper, for more accurate checking of SHM with WSNs, we experimentally compare and evaluate the performance of Xenomai, which provides real-time processing under the traditional Linux kernel. For this purpose, we patch Xenomai into the traditional Linux kernel of a commercial embedded board, Raspberry Pi, and implement a task that periodically reads vibration data of the z-axis from an accelerometer in order to analyze the natural frequency of cantilever beams. Reading the data from the traditional Linux kernel with the same method, we analyze the natural frequency of the cantilever beams using Smart Office Analyzer. Finally, to review the validity of Xenomai for WSNs, we obtain vibration data on the z-axis from the accelerometer via wired network and compared and analyzed them the same way.

A Study on the Control System of Permanent Magnet Linear Synchronous Motor Applied to the Z-axis Operation Structure (Z축 운전구조를 갖는 선형 영구자석형 동기 전동기 운전제어에 관한 연구)

  • Choi, Chul;Lee, Jin-Ha;Park, Han-Woong;Kim, Chul-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.142-149
    • /
    • 2004
  • PMLSM(Permanent Magnet linear Synchronous Motor) has widely applied to industrial automations, machine tools and semiconductor equipments due to the merit on the reduction of noise, vibration and the superior dynamic characteristics in comparison to the conventional method, which uses mechanical transfer equipments. Especially, in the case of applying to Z-axis operation structure, control system needs the method of an initial angle setting and the improvement of up/down operation characteristics. This paper proposes an initial angle setting algorithm and a variable gain schedule using real speed and moving direction to improve up/down operation characteristics. The effectiveness of proposed algorithms Is demonstrated by comparing to a conventional gain system via 4-point absolute positions profile with each velocity, acceleration and deceleration.

Passive Device Library Implementation of LTCC Multilayer Board for Wireless Communications (무선통신용 LTCC 다층기판의 수동소자 라이브러리 구현)

  • Cho, Hak-Rae;Koo, Kyung Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.2
    • /
    • pp.172-178
    • /
    • 2019
  • This paper has designed, fabricated, and analyzed the passive devices realized using low temperature co-fired ceramic (LTCC) multi layer substrates by dividing into the shrinkage process and the non-shrinkage process. Using two types of ceramic materials with dielectric constant 7 or 40, we have fabricated the same shape of various elements in 2 different processes and compared the characteristics. For the substrate of dielctric constant 40, compared with the shrinkage process which has 17% shrink in the X and Y directions with 36% shrink in the Z direction, the non-shrinkage process has 43% shrink in the Z direction without shrink in the X and Y directions, so high dimensional accuracy and surface flatness can be obtained. The inductances and capacitances of the fabricated elements are estimated from measurement using empirical analysis equations of parameters and implemented as a design library. Depending on the substrate and the process, the inductance and capacitance depending on the turn number of winding and unit area have been measured, and empirical polynomials are proposed to predict element values.

Probing Cell-Type Specific Gene Expression in the Ovarian Cells of Drosophila by P-Element Mediated Enhancer Detection (P-요소를 이용한 노랑초파리 난소에서의 세포특이적 유전자발현의 검출)

  • 계명찬;조경상;김경진;이정주
    • The Korean Journal of Zoology
    • /
    • v.38 no.4
    • /
    • pp.505-513
    • /
    • 1995
  • P-lement mediated enhancer detector lines (EDla) were screened for reporter gene (1acZ expression In the ovary of Drosophila mejanogaster Cell-type spedfic 1acZ expression can be grouped Into three parts such as in the geimline, soma, and both. LacZ expression In germline cells was devided into 2 types; expression in nurse cells or in both of the nurse cells and oocote. In the stage-9 to stage-lO follicles, lacZ expression was observed either In the whole follicle cells around oocote or in the subpopulation of follicle cells in egg chamber. lacZ expression in the subset of follicle cells are showed in the centripetal follicle cells or the columnar follicle cells except centripetal follicle cells. Several lines showed anterior to postedor gradient pattern of lacZ expression in the follicle cells. Interestingly there were 3 lines in which lacZ was expressed In the polar cells and/or the horder cells of egg chamber. These lacZ expression patterns in the different ovarian cells of independent EDla reflect the cell type-spedflc expression of maternal genes nesr the P-element insertion, and might provide a basis for cloning of genes involved in oogenesis of Drosophila.

  • PDF