• Title/Summary/Keyword: Young-Hoon Kim

Search Result 9,817, Processing Time 0.048 seconds

A Study on Evaluating Solute Excretion in the Normal Neonate (정상 신생아에서 용질배설 측정 의의에 관한 연구)

  • Choi Jeong Hoon;Kim Mi Kyung;Yoo Kee Hwan;Hong Young Sook;Lee Joo Won;Kim Soon Kyum
    • Childhood Kidney Diseases
    • /
    • v.4 no.1
    • /
    • pp.6-10
    • /
    • 2000
  • Purpose: To evaluate whether the urinary creatinine concentration is a reliable reference value to standardize urinary solute excretion in a spot urine sample during the first week of life. Methods: Spontaneously voided urine specimens were obtained in 49 healthy full term neonates, and in 33 healthy older children with the median ages of $5.7{\pm}4.3$ years, two urine samples were available with an interval of 2 to 3 days. Urine creatinine concentration was determined by the Jaffe test(CoBAS, Integra, Roche, Swiss). Uurine osmolality was determined by the freezing point depression test(Multi-osmette, Precision, USA). Results: Mean urinary creatinine and osmolality values of the first urine samples were not significantly different with the second urine samples in each group. Mean urinary creatinine and osmolality values in neonates were significantly different from the older children of the each urine sample(P<0.01). In neonates, the mean of the urinary oreatinine/osmolality ratios was higher than that of the older children(P<0.01). The urinary creatinine and the creatinine/osmolality values of the first urine samples were closely correlated with those of the second samples in both two groups(P<0.001). Conclusion: The urinary creatinine concentration during the first day of life is relatively stable, even when corrected for urinary osmolality The urinary creatinine and the urinary creatinine/osmolality ratio, therefore, can be used to standardize the urinary excretion of solutes in the neonate.

  • PDF

Crossed Cerebellar and Cerebral Cortical Diaschisis in Basal Ganglia Hemorrhage (기저핵 출혈에 의한 교차 소뇌 해리 현상)

  • Lim, Joon-Seok;Ryu, Young-Hoon;Kim, Hee-Joung;Lee, Byung-Hee;Kim, Byung-Moon;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.397-402
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the phenomenon of diaschisis in the cerebellum and cerebral cortex in patients with pure basal ganglia hemorrhage using cerebral blood flow SPECT. Materials and Methods: Twelve patients with pure basal ganglia hemorrhage were studied with Tc-99m ECD brain SPECT. Asymmetric index (AI) was calculated in the cerebellum and cerebral cortical regions as |$C_R-C_L$/$(C_R-C_L){\times}200$, where $C_R$and $C_L$ are the mean reconstructed counts for the right and left ROIs, respectively. Hypoperfusion was considered to be present when AI was greater than mean +2 SD of 20 control subjects. Results: Mean AI of the cerebellum and cerebral cortical regions in patients with pure basal ganglia hemorrhage was significantly higher than normal controls (p<0.05): Cerebellum ($18.68{\pm}8.94$ vs $4.35{\pm}0.94$, $mean{\pm}SD$), thalamus ($31.91{\pm}10.61$ vs $2.57{\pm}1.45$), basal ganglia ($35.94{\pm}16.15$ vs $4.34{\pm}2.08$), parietal ($18.94{\pm}10.69$ vs $3.24{\pm}0.87$), frontal ($13.60{\pm}10.5$ vs $4.02{\pm}2.04$) and temporal cortex ($15.92{\pm}11.95$ vs $5.13{\pm}1.69$). Ten of the 12 patients had significant hypoperfusion in the contralateral cerebellum. Hypoperfusion was also shown in the ipsilateral thalamus (n=12), ipsilateral parietal (n=12), frontal (n=6) and temporal cortex (n=10). Conclusion: Crossed cerebellar diaschisis (CCD) and cortical diaschisis may frequently occur in patients with pure basal ganglia hemorrhage, suggesting that CCD can develop without the interruption of corticopontocerebellar pathway.

  • PDF

Differentiation of Bone Metastases and Fractures using 24 hour/3 hour Radio-uptake Ratio in Bone Scintigraphy (골신티그라피의 3시간과 24시간 방사능 섭취비를 이용한 골 전이와 골절의 감별)

  • Han, Song-Yee;Chun, Kyung-Ah;Chung, Yong-Ahn;Kim, Sung-Hoon;Kim, Young-Joo;Chung, Soo-Kyo;Park, Seog-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.512-518
    • /
    • 1999
  • Purpose: We evaluated the usefulness of 24 hour/3 hour radio-uptake ratio, lesion to non-lesion ratio, in differentiating bony metastases from acute (<2 months) and healing (${\geq}2$ months) fractures. Materials and Methods: Sixty-three patients (age range: 26-81, 32 males, 31 females) having 90 lesions (30 bone metastases, 30 acute fractures, 30 healing fractures) were included. Bone scans were obtained 3 and 24 hours after administration of 740 MBq of $^{99m}Tc$-MDP. The ratio of radio-uptake in the lesion to normal area was measured as 24/3 hour radio-uptake ratio ([lesion/non-lesion RUR at 24 hour]/[lesion/non-lesion RUR at 3 hour], 24/3 RUR) and analyzed clinical significance in differentiating bone metastases from acute or healing fractures. Results: Mean 24/3 RUR were $1.22{\pm}0.18$ for bone metastases, $1.25{\pm}0.14$ for acute fractures, and $0.99{\pm}0.15$ for healing fractures. 24/3 RUR values of bone metastases and acute fractures were not significantly different. But 24/3 RUR values of bone metastases and healing fractures, and those of acute and healing fractures were found to be significantly different (p<0.001). When 24/3 RUR of 1.0 was considered as the cut off point separating metastases from fracture, a sensitivity of 100% (30/30) was obtained. The specificity was 0% (0/30) in separating metastases from acute fractures, and 47% (14/30) in separating metastases from healing fractures. When 24/3 RUR of 1.2 was considered as the cut off point, sensitivity of 53% (16/30) in the diagnosis of bone metastasis, and specificity of 37% (11/30) in separating metastases from acute fractures, and 100% (30/30) in separating metastases from healing fractures were obtained. Conclusion: 24/3 RUR is useful in differentiating bone metastases from healing fractures, but not in differentiating bone metastases from acute fractures. A 24/3 RUR of less than 1.0 suggests healing fractures. A 24/3 RUR of more than 1.2 suggests bone metastases or acute fractures.

  • PDF

Freezing Time Prediction of Foods by Multiple Regression Analysis (다중회귀분석에 의한 식품의 동결시간 예측)

  • Jeong, Jin-Woong;Kim, Jong-Hoon;Park, Noh-Hyun;Lee, Seung-Hyun;Kim, Young-Dong
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.341-347
    • /
    • 1998
  • To develop simple and accurate analytical method for freezing time prediction of beef and tylose under various freezing conditions, freezing time (Y) was regressed against the reciprocal $(X_3)$ of difference of initial freezing point and freezing medium temperature, reciprocal $(X_4)$ of surface heat transfer coefficient, the initial temperature $(X_1)$ and thickness $(X_2)$ of samples which should cover most situations arising in frozen food industry. As results of the multiple regression analysis, equations were obtained as follows. $Y_{tylose}=3.45X_1+7642.84X_2+4642.67X_3+2946.89X_4-431.33\;(R^2=0.9568)$ and $Y_{beef}=0.68X_1+7568.98X_2+2430.78X_3+3293.26X_4-299.00\;(R^2=0.9897)$. These equations offered better results than Plank, Nagaoka and Pham's models, shown in satisfactory agreement with models of Cleland & Earle and Hung & Thompson when were compared to previous models, and the accuracy of its was very high as average absolute difference of about 10% in the difference between the fitted and experimental results. Also, thermal diffusivities of beef and tylose were measured as $4.43{\times}10^{-4}m^2/hr$ and $4.39{\times}10^{-4}m^2/hr$ at $6{\sim}7^{\circ}C$, $2.42{\times}10^{-3}m^2/hr$ and $3.32{\times}10^{-3}m^2/hr$ at $-10{\sim}-12^{\circ}C$. Initial freezing points of beef and tylose were $-1.2^{\circ}C\;and\;-0.6^{\circ}C$, respectively. Surface heat transfer coefficients were estimated $20.57\;W/m^2^{\circ}C$ with no-packing, $16.11\;W/m^2^{\circ}C$ with wrap packing and $13.07\;W/m^2^{\circ}C$ with Al-foil packing, and the cooling rate of immersion freezing method was about 10 times faster than that of air blast freezing method.

  • PDF

Development of Analytical Methods of Spinosad in Agricultural Commodities by HPLC with UV Detector and Monitoring (HPLC-UVD를 이용한 농산물 중 스피노사드 분석법 개선 및 잔류실태 조사)

  • Kim, Hee-Yun;Choi, Sun-Hee;Chung, So-Young;Choi, Hee-Ju;Kim, Yong-Hoon;Cho, Min-Ja;Seo, Eun-Chae;Han, Kyoung-Jin;Choi, Jae-Chun;Park, Hee-Ok;Ha, Sang-Chul;Shin, Il-Shik;Eom, Ji-Yoon
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.2
    • /
    • pp.125-133
    • /
    • 2011
  • The purpose of this study was to develop a methodology to detect spinosad which are difficult to analyze by multi-component simultaneous analysis of pesticide residues. We monitored spinosad due to the paucity of related information. The spinosad was determined using HPLC with UV detector at 250 nm. Correlation coefficient ($r^2$) for standard curve of spinosad A and D at standard concentration of 0.1-5.0 mg/kg were 0.999, respectively. Limit of quantitation (LOQ) of HPLC analysis was 0.005 mg/kg while limit of detection (LOD) was 0.001 mg/kg. Recovery experiments were conducted on five representative agricultural products to validate the analytical method. The recovery of proposed methods ranged from 74.9% to 104.0% and relative standard deviations were less than 10%. Spinosad residues were investigated in 16 commodities collected from 22 provinces. In this study, residues on all samples were not detected.

A Simultaneously Analytical Method of Phthalate and Adipate Plasticizers in Food Packaging by Dual-Column GC-FID System (Dual-Column GC-FID System을 이용한 식품 포장재 중 Phthalate류 및 Adipate류 가소제의 동시 분석법)

  • Kang Gil-Jin;Kwak In-Shin;Eom Mi-Ok;Jeon Dea-Hoon;Kim Hyung-il;Sung Jun-Hyun;Choi Jung-Mi;Kim Eun-Kyung;Lee Young Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.4
    • /
    • pp.277-283
    • /
    • 2005
  • A plasticizer is a substance which is added to a material to improve its processability, flexibility and stratchability. Phthalates and adipates are the most frequently used plasticizers of poly(vinyl chloride) (PVC). However, they can migtate into food from PVC food packaging, and some of them are especially suspected as endocrine disruptors. In this study, Simultaneous analysis of 13 phthalates and 9 adipates were carried out by dual-column gas chromatography system equipped wi two FID detectors for rapid confirmation and quantification. The Proposed method was validated with > 0.993 of linearity in the ranges of 10-500 mg/l, < $3.5\%$ RSD of reproducability in 10 inter-days sample preparations, and > $98.1\%$ of recoveries for all the plasticizers. DEHA was detected in all the 3 PVC wraps at levels of 176.9-198.5mg/g. Among the 51 samples of PVC gaskets, the targeted plasticizers were detected in 41 samples. Of these plasticizer detected samples,40 contained DIDP at the levels of 157.3-374.7 mg/g and one contained DMP at the levels of 165.6 mg/g. Also, some plasticizers were detected in other packaging materials such as PET, PP, PE, Pulp. But it might be attributed to contamination in manufacturing.

Characteristics of Vertical Ozone Distributions in the Pohang Area, Korea (포항지역 오존의 수직분포 특성)

  • Kim, Ji-Young;Youn, Yong-Hoon;Song, Ki-Bum;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.21 no.3
    • /
    • pp.287-301
    • /
    • 2000
  • In order to investigate the factors and processes affecting the vertical distributions of ozone, we analyzed the ozone profile data measured using ozonesonde from 1995 to 1997 at Pohang city, Korea. In the course of our study, we analyzed temporal and spatial distribution characteristics of ozone at four different heights: surface (100m), troposphere (10km), lower stratosphere (20km), and middle stratosphere (30km). Despite its proximity to a local, but major, industrial complex known as Pohang Iron and Steel Co. (POSCO), the concentrations of surface ozone in the study area were comparable to those typically observed from rural and/or unpolluted area. In addition, the findings of relative enhancement of ozone at this height, especially between spring and summer may be accounted for by the prevalence of photochemical reactions during that period of year. The temporal distribution patterns for both 10 and 20km heights were quite compatible despite large differences in their altitudes with such consistency as spring maxima and summer minima. Explanations for these phenomena may be sought by the mixed effects of various processes including: ozone transport across two heights, photochemical reaction, the formation of inversion layer, and so on. However, the temporal distribution pattern for the middle stratosphere (30km) was rather comparable to that of the surface. We also evaluated total ozone concentration of the study area using Brewer spectrophotometer. The total ozone concentration data were compared with those derived by combining the data representing stratospheric layers via Umkehr method. The results of correlation analysis showed that total ozone is negatively correlated with cloud cover but not with such parameter as UV-B. Based on our study, we conclude that areal characteristics of Pohang which represents a typical coastal area may be quite important in explaining the distribution patterns of ozone not only from surface but also from upper atmosphere.

  • PDF

Comparison of Gangjihwan and Combination of Gangjihwan and Gamisochehwan in the Improvement Effects of Nonalcoholic Fatty Liver Disease in a High Fat Diet-Fed NAFLD Mouse Model (고지방식이 비만마우스 모델에서 강지환(降脂丸)과 강지환(降脂丸)+가미소체환(加味消滯丸)의 비알콜성 지방간질환 개선효과 비교)

  • Jang, Du Hyon;Jung, Yang Sam;Kim, Jong Hoon;Kim, Byeong Chul;Seok, Hoa Jun;Yoo, Jae Sang;Ku, Ja Ryong;Yoon, Ki Hyeon;Jo, Ju Heum;Lee, Hye Rim;Roh, Jong Seong;Yun, Ho Young;Yoon, Michung;Shin, Soon Shik
    • Herbal Formula Science
    • /
    • v.22 no.1
    • /
    • pp.167-176
    • /
    • 2014
  • Objectives : This study investigated the improvement effects of Gangjihwan (DF) and combination of Gangjihwan and Gamisochehwan (GSH) on nonalcoholic fatty liver disease in a high fat diet-induced obese mouse model. Methods : Eight-week-old C57BL/6N mice were divided into five groups: a normal lean group given a standard diet, an obese control group given a high fat diet, and atorvastatin, DF, and DF+GSH groups given a high fat diet with atorvastatin (10 mg/kg), DF (40 mg/kg), and DF+GSH (80 mg/kg), respectively. After 8 weeks of treatment, body weight gain, blood lipid markers, ALT concentrations, liver weight and histology were examined. Results : 1. Body weight gain was significantly decreased in DF, DF+GSH and atorvastatin groups compared with control. The extent of decreases was eminent in DF+GSH group. 2. Circulating concentrations of total cholesterol, HDL-cholesterol and LDL-cholesterol were decreased in DF, DF+GSH and atorvastatin groups compared with control. The decreases were significant in DF+GSH and atorvastatin groups. 3. Liver weights were decreased in DF, DF+GSH and atorvastatin groups compared with control. In particular, liver weight was significantly reduced only in DF+GSH group. 4. Hepatic lipid accumulation was significantly decreased in DF, DF+GSH and atorvastatin groups compared with control, and the magnitude of which was more effective in DF+GSH group than in DF-only group. 5. Circulating ALT concentrations were decreased in DF, DF+GSH and atorvastatin compared with control, but ALS levels were significantly reduced only in DF+GSH group. Conclusions : In conclusion, these results suggest that DF decreases body weight gain, improves blood lipid metabolism, and reduces liver weight and hepatic lipid accumulation, contributing to the improvement of nonalcoholic fatty liver disease. In addition, these effects were more effective in DF+GSH combination group than in DF-only group.

The Study of Error for Analysis in Dynamic Image from the Error of Count Rates in NaI (Tl) Scintillation Camera (NaI (Tl) 신틸레이션 카메라에서 계수율 오차에 따른 동적 영상 분석치 산출 오류에 관한 연구)

  • Oh, Joo-Young;Kang, Chun-Goo;Kim, Jung-Yul;Park, Hoon-Hee;Oh, Ki-Baek;Kim, Jae-Sam
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.291-297
    • /
    • 2013
  • This study is aimed to evaluate the effect of $T_{1/2}$ upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with $^{99m}TcO_4^-$ of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in $x^2$ test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of $T_{1/2}$ error from change of gradient with -0.25% to +0.25%, if $T_{1/2}$ is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see $T_{1/2}$ error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a tendency that count rate changes over time at this study, and we proved that it can effect $T_{1/2}$. And also, there is need of appropriate phantoms and the method of quality management like this study, because there are not any advice or limitation degrees for domestic medical purpose scintillation camera.

Preliminary Investigations of the Dosimetric Properties of a Normoxic Polymethacrylic Acid Gel Dosimeter Using a Respiration-Motion Simulator (호흡모의움직임장치를 이용한 정상산소 폴리메타크릴산 겔 선량계의 선량특성)

  • Park, Chae Hee;Cho, Yu Ra;Cho, Kwang Hwan;Park, Ji Ae;Kim, Kyeong Min;Kim, Kum Bae;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.138-144
    • /
    • 2012
  • Dose distribution throughout the clinical organ range of motion was analyzed using a respiratory-motion simulator that was equipped with a polymer gel dosimeter and EBT2 film. The normoxic polymer gel dosimeter was synthesized from gelatin, MAA, HQ, THPC and HPLC. The gel dosimeter and EBT2 film were irradiated with Co-60 gamma rays that were moved along the x-axis and y-axis in ${\pm}1.5cm$ steps at five-second intervals. The field size was $5{\times}5cm^2$. The SSD was 80 cm and set to 10 Gy at a depth of 2 cm. The PDD at a depth of 50 mm was 75.2% in the ion chamber, 82.3% in the static state and 86.1% in the dynamic state in the gel dosimeter. The penumbra for the dynamic state target, which was measured using the gel dosimeter, averaged 10.89 mm, this is a 40.5% increase over the penumbra of the static state target of 7.74 mm. In addition, when measuring with gel dosimetry, the value for the penumbra is 36.6% smaller in the static state and 29.4% smaller in the dynamic state compared to measuring with film. The aim of this study was to investigate the dosimetric properties of a normoxic polymethacrylic acid gel dosimeter in static and dynamic states and to evaluate the potentiality as a relative dosimeter for dynamic therapeutic radiation.