• Title/Summary/Keyword: Yongin

Search Result 1,073, Processing Time 0.023 seconds

Effects of Ankle Joint Taping on Postural Balance Control in Stroke Patients

  • Kim, Yang Rae;Kim, Jae Ic;Kim, Yong Youn;Kang, Kwon Young;Kim, Bo Kyoung;Park, Joo Hyun;An, Ho Jung;Min, Kyung Ok
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.3 no.2
    • /
    • pp.446-452
    • /
    • 2012
  • This study aims to examine the effects of taping of the ankle joint on the static and dynamic balance and gait ability of stroke patients. Twenty-six stroke patients receiving physical therapy at a hospital located in Gyeonggi-do were divided equally into a group that had taping in physical therapy and an ordinary physical therapy group. They exercised for 30 minutes each, 3 times per week for 8 weeks from June to August 2011. Romberg's eye open and eye closed tests, limits of stability(LOS), forward and back test, timed up and go test(TUG) and 10-meter gait velocity test were performed to evaluate static balance, dynamic balance, and gait ability, respectively, prior to and 8 weeks after the intervention. Differences within each group in relation to the lapse of time were compared by a paired t-test. Differences between the two groups were compared by an independent t-test. Regarding comparison of differences within each group, all tests resulted in significant changes in both groups after the intervention (p<.05). Comparison of differences between the two groups showed that taping in the physical therapy group had significantly better test results than the ordinary physical therapy group in all measured items(p<.05). The after effects of ankle taping on stroke patients are more efficient and effective than ordinary physical therapy alone in improving balance and gait ability.

Effects of honeybee (Apis mellifera L.) venom by water supply on the performance of broiler chicken (봉독의 급수투여가 육계의 생산성에 미치는 영향)

  • Han, Sang-Mi;Lee, Kwang-Gill;Yeo, Joo-Hong;Oh, Baeg-Young;Kim, Bong-Soon;Lee, Woong;Kim, Soon-Tae
    • Korean Journal of Veterinary Service
    • /
    • v.33 no.2
    • /
    • pp.177-183
    • /
    • 2010
  • This study was conducted to investigate the antibiotic effects of bee venom (Apis mellifera) on the growth performance and blood characteristics in broiler chicken. 1-day-old broiler chicks were randomly divided into 3 groups with 3 replicates of 5,000 birds each. The treatments were control without antibiotic and bee venom, 0.5ppm or 1ppm bee venom. The final body weight and body weight gain were significantly higher in bee venom than control (P<0.05). The feed conversion ratio in all treated groups were significantly improved as compared to that of control (P<0.05). No significant differences among the groups were observed in the contents of total cholesterol, aspartate aminotransferase (AST), alanine aminotransferase (ALT), total protein, albumin and globulin in blood serum. The white blood cell, red blood cell, heterophil, lymphocyte, and stress indicator (heterophil:lymphocyte rate) were not significantly different among the groups. The superoxide dismutase-like activities in the groups that were water containing bee venom were significantly increased compared to those in the control group (P<0.05). It has been suggested that bee venom promotes the growth of broilers without any negative effect when added in broiler water.

Buccal cortical bone thickness on CBCT for mini-implant (치과용 콘빔CT영상에서 미니임플란트를 위한 협측피질골 두께)

  • Goo, Jong-Gook;Lim, Sung-Hoon;Lee, Byoung-Jin;Kim, Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.179-185
    • /
    • 2010
  • Purpose : Cortical bone thickness is one of the important factor in mini-implant stability. This study was performed to investigate the buccal cortical bone thickness at every interdental area as an aid in planning mini-implant placement. Materials and Methods : Two-dimensional slices at every interdental area were selected from the cone-beam computed tomography scans of 20 patients in third decade. Buccal cortical bone thickness was measured at 2, 4, and 6 mm levels from the alveolar crest in the interdental bones of posterior regions of both jaws using the plot profile function of $Ez3D2009^{TM}$ (Vatech, Yongin, Korea). The results were analyzed using by Mann-Whitney test. Results : Buccal cortical bone was thicker in the mandible than in the maxilla. The thickness increased with further distance from the alveolar crest in the maxilla and with coming from the posterior to anterior region in the mandible (p<0.01). The maximum CT value showed an increasing tendency with further distance from the alveolar crest and with coming from posterior to anterior region in both jaws. Conclusion : Interdental buccal cortical bone thickness varied in both jaws, however our study showed a distinct tendency. We expect that these results could be helpful for the selection and preparation of mini-implant sites.

Cyclic Alternating Pattern : Implications for Insomnia (불면증에서 순환교대파형의 의미)

  • Cyn, Jae-Gong
    • Sleep Medicine and Psychophysiology
    • /
    • v.17 no.2
    • /
    • pp.75-84
    • /
    • 2010
  • The cyclic alternating pattern (CAP) is a periodic EEG activity in NREM sleep, characterized by sequences of transient electrocortical events that are distinct from background EEG activities. A CAP cycle consists of two periodic EEG features, phase A and subsequent phase B whose durations are 2-60 s. At least two consecutive CAP cycles are required to define a CAP sequence. The CAP phase A is a phasic EEG event, such as delta bursts, vertex sharp transients, K-complex sequences, polyphasic bursts, K-alpha, intermittent alpha, and arousals. Phase B is repetitive periods of background EEG activity. The absence of CAP more than 60 seconds or an isolated phase A is classified as non-CAP. Phase A activities can be classified into three subtypes (A1, A2, and A3), based on the amounts of high-voltage slow waves (EEG synchrony) and low-amplitude fast rhythms (EEG desynchrony). CAP rate, the percentage of CAP durations in NREM sleep is considered to be a physiologic marker of the NREM sleep instability. In insomnia, the frequent discrepancy between self-reports and polysomnographic findings could be attributed to subtle abnormalities in the sleep tracing, which are overlooked by the conventional scoring methods. The conventional scoring scheme has superiority in analysis of macrostructure of sleep but shows limited power in finding arousals and transient EEG events that are major component of microstructure of sleep. But, it has recently been found that a significant correlation exists between CAP rate and the subjective estimates of the sleep quality in insomniacs and sleep-improving treatments often reduce the amount of CAP. Thus, the extension of conventional sleep measures with the new CAP variables, which appear to be the more sensitive to sleep disturbance, may improve our knowledge on the diagnosis and management of insomnia.

  • PDF

Analysis on the Prevention Measures and Factors of Alcohol-related Accident in the Construction Industry (건설업에서 음주사고 예방대책 실시현황 및 관련요인분석)

  • Lee, Na-Kyeong;Jung, Hye-Sun;Yi, Yun-Jeong;Jhang, Won-Gi;Kim, Ji-Yun;Yi, Kwan-Hyung
    • Korean Journal of Occupational Health Nursing
    • /
    • v.18 no.1
    • /
    • pp.98-105
    • /
    • 2009
  • Purpose: This study was to analyze the current preventive measures on alcohol-involved accident and the factors that affect such preventive measures in the construction industry. Method: The survey was administered to examine how the preventive measures on alcohol-involved accident were executed using the data of '2005 Occupational Safety and Health Survey' conducted in 2005 by the Occupational Safety and Health Research Institute. For this study, we analyzed 944 work places in the construction industry. Result: The preventive measures on alcohol-involved accident were being executed in 62.1% of construction companies. As for the number of actual preventive measures on alcohol-involved accident, work places in Jeolla-do executed 2.63 times more frequently than those in Chungcheong-do, and work places with the Occupational Safety and Health Conference executed 2.22 times more frequently than those without such a measure. Conclusion: Joining the Occupational Safety and Health Conference was to be one of the most influential ways of preventive measures on alcohol-involved accident in the construction industry. Accordingly, if workers and employers look for active measures and administer them through the Occupational Safety and Health Conference, it will reduce alcohol-involved accident in the construction industry and contribute to the better preventive measures on alcohol-involved accident in the construction and other industries.

  • PDF

Development of Artificial Neural Network Techniques for Landslide Susceptibility Analysis (산사태 취약성 분석 연구를 위한 인공신경망 기법 개발)

  • Chang, Buhm-Soo;Park, Hyuck-Jin;Lee, Saro;Juhyung Ryu;Park, Jaewon;Lee, Moung-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.499-506
    • /
    • 2002
  • The purpose of this study is to develop landslide susceptibility analysis techniques using artificial neural networks and to apply the newly developed techniques for assessment of landslide susceptibility to the study area of Yongin in Korea. Landslide locations were identified in the study area from interpretation of aerial Photographs and field survey data, and a spatial database of the topography, soil type and timber cover were constructed. The landslide-related factors such as topographic slope, topographic curvature, soil texture, soil drainage, soil effective thickness, timber age, and timber diameter were extracted from the spatial database. Using those factors, landslide susceptibility and weights of each factor were analyzed by two artificial neural network methods. In the first method, the landslide susceptibility index was calculated by the back propagation method, which is a type of artificial neural network method. Then, the susceptibility map was made with a GIS program. The results of the landslide susceptibility analysis were verified using landslide location data. The verification results show satisfactory agreement between the susceptibility index and existing landslide location data. In the second method, weights of each factor were determinated. The weights, relative importance of each factor, were calculated using importance-free characteristics method of artificial neural networks.

  • PDF

Research of Characterization of Covalently Cross-linked SPEEK/Cs-Substituted MoPA/Ceria 1wt% Composite Membrane for Water Electrolysis (Cs 치환에 따른 수전해용 공유가교 SPEEK/Cs(n)-MoPA/Ceria 1%(n = 1~3) 복합막의 특성 연구)

  • Park, Daeyoung;Hwang, Sungha;Oh, Seunghee;Yoon, Daejin;Kang, Ansoo;Moon, Sangbong;Chung, Janghoon
    • Journal of Hydrogen and New Energy
    • /
    • v.25 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • Ceria ($CeO_2$) was used to scavenge free radicals which attack the membrane in the polymer electrolyte membrane water electrolysis (PEMWE) circumstance and to increase the duration of the membrane. In order to improve the electrochemical, mechanical and electrocatalytic characteristics, engineering plastic of the sulfonated polyether ether ketone (SPEEK) as polymer matrix was prepared in the sulfonation reaction of polyether ether ketone (PEEK) and the organic-inorganic blended composite membranes were prepared by sol-gel casting method with loading the highly dispersed ceria and cesium-substituted phophomolybdic acid(Cs-MoPA) with cross-linking agent contents of 0.01mL. In conclusion, CL-SPEEK/$Cs_{(2.5)}$-MoPA/ceria(1%) membrane showed the optimum results such as 0.1095S/cm of proton conductivity at $80^{\circ}C$, 2.906meq./g-dry-membrane of ion exchange capacity and mechanical characteristics, and 49.73MPa of tensile strength which were better than Nafion 117 membrane.

A Heuristic Technique for Generating the Synchronizable and Optimized Conformance Test Sequences (최적화된 동기적 적합성시험 항목의 발견적 생성 방법)

  • Kim, Chul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.6
    • /
    • pp.470-477
    • /
    • 2015
  • This paper presents a new technique for generating an optimum synchronizable test sequence that can be applied in the distributed test architecture where both external synchronization and input/output operation costs are taken into consideration. The method defines a set of phases that constructs a tester-related digraph from a given finite state machine representation of a protocol specification such that a minimum cost tour of the digraph with intrinsically synchronizable transfer sequences can be used to generate an optimum synchronizable test sequence using synchronizable state identification sequences as the state recognition sequence for each state of the given finite state machine. This hybrid approach with a heuristic and optimization technique provides a simple and elegant solution to the synchronization problem that arises during the application of a predetermined test sequence in some protocol test architectures that utilize remote testers.

EM Algorithm based Air Flow and Power Data classification Analysis (EM 알고리즘기반의 공기 유량 및 전력 데이터 분류 분석)

  • Shim, Jae-Ryong;Noh, Young-Bin;Jung, Hoe-kyung;Kim, Yong-Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.551-553
    • /
    • 2016
  • Since air compressor, as an essential equipment used in the factory and plant operations, accounts for around 20% of the total domestic electricity consumption, a real time sensor data monitoring based analysis for electricity consumption reduction is important. In particular, flow rates and pressures of these monitored variables has a direct correlation with the power consumption. This paper proposes a method to identify if the measurement error of the flow rate sensor comes from the sensor measurement limit through bivariate classification analysis of the flow rate and power using the EM (Expectation and Maximization) Algorithm and show how to enable more accurate analysis by the correlation between the flow rate and power on the right-censored data.

  • PDF

Quantitative Assay of Recombinant Hepatitis B Surface Antigen by Using Surface Plasmon Resonance Biosensor (Surface plasmon resonance 바이오센서를 이용한 재조합 B형 간염 표면항원의 정량분석)

  • Lee, E. K.;Ahn, S. J.;Yoo, C. H.;Ryu, K.;Jeon, J. Y.;Lee, H. I.;Choi, S. C.;Lee, Y. S.
    • KSBB Journal
    • /
    • v.17 no.1
    • /
    • pp.20-25
    • /
    • 2002
  • We performed a basic experiment for rapid, on-line, real-time measurement of HBsAg by using a surface plasmon resonance biosensor to quantify the recognition and interaction of biomolecules. We immobilized the anti-HBsAg polyclonal antibody to the dextran layer on a CM5 chip surface which was pre-activated by N-hydroxysuccinimide for amine coupling. The binding of the HBsAg to the immobilized antibody was measured by the mass increase detected by the change in the SPR signal. The binding characteristics between HBsAg and its antibody followed typical monolayer adsorption isotherm. When the entire immobilized antibody was interacted, there was no additional, non-specific binding observed, which suggested the biointeraction was very specific as expected and independent of the ligand density. No significant steric hindrance was observed at 17.6 nm/$mm^2$ immobilization density. The relationship between the HBsAg concentration in the sample solution and the antigen bound to the chip surface was linear up to ca. $40\mu\textrm{g}$/mL, which is much wider than that of the ELISA method. It appeared the antigen-antibody binding was increased as the immobilized ligand density increased, but verification is warranted. This study showed the potential of this biosensor-based method as a rapid, simple, multi-sample, on-line assay. Once properly validated, it can serve as a more powerful method for HBsAg quantification replacing the current ELISA method.