• Title/Summary/Keyword: Yang Song-u

Search Result 123, Processing Time 0.022 seconds

Standardization and unification of the terms and conditions used for diagnosis in oriental medicine III (한의진단명과 진단요건의 표준화 연구III - 3차년도 연구결과 보고 -)

  • Choi, Sun-Mi;Yang, Ki-Sang;Choi, Seung-Hoon;Park, Kyung-Mo;Park, Jong-Hyun;Shim, Bum-Sang;Kim, Sung-Woo;Roh, Seok-Seon;Lee, In-Seon;Cheong, Jin-Hong;Lee, Jin-Yong;Kim, Dal-Rae;Im, Hyeong-Ho;Kim, Yun-Beom;Park, Seong-Sik;Song, Tae-Won;Kim, Jong-U;Lee, Seung-Gi;Choe, Yun-Jeong;Sin, Sun-Sik
    • Korean Journal of Oriental Medicine
    • /
    • v.3 no.1
    • /
    • pp.41-65
    • /
    • 1997
  • The diagnostic requirements were suggested and explained regarding the systems of differentiation of symptoms and signs in the third year study of standardization and unification of the terms and conditions used for diagnosis in oriental medicine. The systems were as follows : - analysing and differentiating of epidemic febrile disease - analysing and differentiating in accordance with the Sasang constitutional medicine baced on four-type recognition - differentiation of diease according to pathological changes of Chong and Ren channels - standards for diagnosis of women's disease - standards for diagnosis of children's disease - standards for diagnosis of motor and sensor disturbance(-muscle born joint etc.) - standards for diagnosis of neuropsychiatric diease - standards for diagnosis of five sense organ diease - standards for diagnosis of external disease. The indivisual diagnosis pattern was arranged by the diagnostic requirments in the following odor : another name, notion of diagnosis pattern, index of differentiation of symptoms and signs, the main point of diagnosis, analysis of diagnosis pattern, discrimination of diagnosis pattrrn, prognosis, a way of curing a diseases, prescription, herbs in common use, dieases appearing the diagnosis pattern, documents. The standards for diagnosis of each disease was arranged by the diagnostic requirments in the following odor. another name, notion of diease, the main point of diagnosis, analysing and differentiating of disease, analysis of diease, discrimination of disease, prognosis, a way of curing and prescription of disease, dieases In western medicine appearing the disease in oriental medicine, documents.

  • PDF

Study on the Acceptability and Effectiveness of an Oral Contraceptive Among Iud Drop-outs in Rural Korea

  • Yang, J.M.;Bang, S.;Song, S.W.;Youn, B.B.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.51-66
    • /
    • 1968
  • During a period of about one year(November '66 to December '67), the Yonsei University College of Medicine conducted a field trial of the oral contraceptive(Ovulen) in order to study its acceptability and use-effectiveness among IUD drop-outs in Koyang county. We can summarize the outstanding findings from this investigation as follows; 1. 61.4% of the IUD drop-outs interviewed (911 women) wanted to use the pill. Most of the reasons for not wanting to use it(352 women) pertained to either use of other contraceptive methods(98) or subfecundity(150) following IUD terminations. Only 83 out of 911 women gave reasons related to the difficulty of obtaining pills. Therefore, we can state that most IUD drop-outs if still in need of a contraceptive methods are in favor of trying the pill, and especially so if this method is conveniently available. 2. The 467 women or 37% of those who terminated IUD use actually visited the clinic for medical screening, and only 11 of them or 2.4% were rejected because of pregnancy and other medical reasons such as cervical erosion, myoma, breast mass, etc. 5.5% or 25 of the 456 women who received the first cycle did not take a single pill during the study period. 3. When we defined those 431 women who accepted and took one or more tablets we found that women over age 30, with 4 or more children, and/or with a higher educational level were the best prospects for recruitment. 4. In accuracy of use, about two thirds of the users started taking the pill on the 5 th day as directed for the first three cycles, but the percentages rose sharply to about 80% in later cycles. Tardiness in starting pill use in the first cycle may have occurred partly because they had to return to the clinic monthly to get each new cycle. Among acceptors who did not quit between cycles, 80 to 90% were regular users, missing two or less tablets in each cycle. 5) More than 60% of the users felt well and sometimes lost their pre-acceptance symptoms. especially dysmenorrhea. However, 27.4% (58 women) had side effects attributable to the pill compund as nausea, vomiting, indigestion, breast tenderness, decreased lactation or breakthrough bleeding. 25.0% (53 women) also complained of medical diseases or symptoms not related to the pill, especially during the first three cycles. However, as the confidence and experience of the client and the field workers grew, the incidence of unrelated medical complaints quickly fell to a lower level in the later cycles. 6. As of the end of this study, on December 31, 1967, 49.2% (212 women) had discontinued the use of the pill for medical reasons as well as for the non medical reasons. Only one case terminated use due to a pregnancy after taking pills. The cumulative continuation rates (by the life table method), were 58.9%, 51.9%, 41.0% at the end of 3 months, 6 months and one year, respectively. These rates are lower than in the U.S. studies. Even when we add the retaking group to the first segment, the continuation rate goes up only about 5% above the first segment rates mentioned above. Possible explanations are different dosages, the newerness of the method and the use of only one point for pill distribution in the country together with a monthly return for cycle 1, 2, 3, and 4-6.

  • PDF

Heavy concrete shielding properties for carbon therapy

  • Jin-Long Wang;Jiade J Lu;Da-Jun Ding;Wen-Hua Jiang;Ya-Dong Li;Rui Qiu;Hui Zhang;Xiao-Zhong Wang;Huo-Sheng Ruan;Yan-Bing Teng;Xiao-Guang Wu;Yun Zheng;Zi-Hao Zhao;Kai-Zhong Liao;Huan-Cheng Mai;Xiao-Dong Wang;Ke Peng;Wei Wang;Zhan Tang;Zhao-Yan Yu;Zhen Wu;Hong-Hu Song;Shuo-Yang Wei;Sen-Lin Mao;Jun Xu;Jing Tao;Min-Qiang Zhang;Xi-Qiang Xue;Ming Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2335-2347
    • /
    • 2023
  • As medical facilities are usually built at urban areas, special concrete aggregates and evaluation methods are needed to optimize the design of concrete walls by balancing density, thickness, material composition, cost, and other factors. Carbon treatment rooms require a high radiation shielding requirement, as the neutron yield from carbon therapy is much higher than the neutron yield of protons. In this case study, the maximum carbon energy is 430 MeV/u and the maximum current is 0.27 nA from a hybrid particle therapy system. Hospital or facility construction should consider this requirement to design a special heavy concrete. In this work, magnetite is adopted as the major aggregate. Density is determined mainly by the major aggregate content of magnetite, and a heavy concrete test block was constructed for structural tests. The compressive strength is 35.7 MPa. The density ranges from 3.65 g/cm3 to 4.14 g/cm3, and the iron mass content ranges from 53.78% to 60.38% from the 12 cored sample measurements. It was found that there is a linear relationship between density and iron content, and mixing impurities should be the major reason leading to the nonuniform element and density distribution. The effect of this nonuniformity on radiation shielding properties for a carbon treatment room is investigated by three groups of Monte Carlo simulations. Higher density dominates to reduce shielding thickness. However, a higher content of high-Z elements will weaken the shielding strength, especially at a lower dose rate threshold and vice versa. The weakened side effect of a high iron content on the shielding property is obvious at 2.5 µSv=h. Therefore, we should not blindly pursue high Z content in engineering. If the thickness is constrained to 2 m, then the density can be reduced to 3.3 g/cm3, which will save cost by reducing the magnetite composition with 50.44% iron content. If a higher density of 3.9 g/cm3 with 57.65% iron content is selected for construction, then the thickness of the wall can be reduced to 174.2 cm, which will save space for equipment installation.