• 제목/요약/키워드: YBCO CC

검색결과 65건 처리시간 0.039초

Tripod polishing을 이용한 IBAD/RABiTS 기판의 TEM 분석 (TEM analysis of IBAD/RABiTS substrates prepared by Tripod polishing)

  • 최순미;정준기;유상임;박찬;오상수;김철진
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권1호
    • /
    • pp.9-14
    • /
    • 2006
  • Sample preparation plays a critical role in microstructure analysis using TEM. Although TEM specimen has been usually prepared by jet-polishing or Ar-ion beam milling technique. these methods could not be applied to YBCO CC which is composed of IBAD or RABiTS substrates, several buffet layers, and YBCO superconducting layer because of big difference in mechanical strengths between the metallic phase and oxide phases. To obtain useful cross-sectional information such as interface between the phases or second phases in YBCO CC, it is prerequisite to secure the large area of thin section in the cross-sectional direction. The superconducting layer or the buffer layers are relatively weak and fragile compared to the metallic substrate such as Ni-5wt%W RABiTS of Hastelloy-based IBAD, and preferential removal of weak ceramic phases during polishing steps makes specimen preparation almost impossible. Tripod polisher and small jig were home-made and employed to sample preparation. The polishing angle was maintained <$1^{\circ}$ throughout the polishing steps using 2 micrometers attached to the tripod plate. TEM specimens with large and thin area could be secured and used for RABiTS/IBAD substrate analyses. In some cases, additional Ar-beam ion milling with low beam current and impinging angle was used for less than 30 sec. to remove debris or polishing media attacked to the specimens.

대전류용 초전도 연속전위도체의 외부자장 인가방향에 따른 자화손실 특성 (Angular Dependency of Magnetization Losses in Continuously Transposed Coated Conductors for Large Current Applications)

  • 한병욱;김우석;이지광;이세연;박상호;김영일;최경달
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.51-56
    • /
    • 2010
  • AC loss is main issue for power applications using YBCO coated conductor. The striated YBCO CC(Coated Conductor) has been proposed by several researchers to decrease a magnetization loss. A continuously transposed coated conductor (CTCC), suggested by our research group before, could be very useful for lower magnetization loss of large current power applications. In this paper, an AC loss reduction effect by the stack, striation and transposition of YBCO CCs under a time varying external magnetic field. To estimate the reduction effects for perpendicular magnetization loss, several CTCC samples were prepared and tested. Also, we measured angular dependency of magnetization losses of various CTCC samples.

A Study on the Short Circuit Characteristic of Metallic Stabilizer Free Coated Conductor for FCL Application

  • Park, Dong-Keun;Kim, Min-Jae;Yang, Seong-Eun;Kim, Young-Jae;Chang, Ki-Sung;Na, Jin-Bae;Ko, Tae-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권4호
    • /
    • pp.37-40
    • /
    • 2007
  • As power demands increase, development of the superconducting fault current limiter (SFCL) is being watched with interest. Many types of SFCLs using various superconducting materials have been developed. Especially, the FCL using coated conductor (CC) has been investigated actively at present. CCs have many advantages for the FCL application. YBCO materials used in CCs have a high n-value, and it is relatively easy to choose a matrix of the CC for high resistivity. If the CC has high resistivity, high voltage can be applied to the CC. Then total length of the CC used in SFCL, which has effects on total price and volume of the SFCL, can be reduced. Short circuit tests of two different types of CCs in the liquid nitrogen bath and its sub-cooled condition were performed and analyzed. An effect of high resistivity of the CC and cooling methods on fault current limiting characteristics could be verified in this paper.

차세대 고온초전도 선재를 이용한 영구전류시스템의 히터트리거 특성 해석 (A Characteristic Analysis of Heater Triggered Persistent Current System with 2G High Tc Superconducting Tape)

  • 박동근;강형구;양성은;안민철;윤용수;윤경용;이상진;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1228-1230
    • /
    • 2005
  • This paper deals with design of heater trigger switching in a persistent current system(PCS) by finite element method(FEM) analysis of YBCO coated conductor(CC) tape. Most promising superconducting wire is YBCO coated conductor tape in these days for its high n value and critical current independency from external magnetic field. It is expected to be used many superconducting application such as fault current limiter and cable etc. The superconducting magnet which is operated in persistent current mode in SMES, NMR, MRI and MAGLEV has many advantages such as a high uniformity of a magnetic field and reducing a thermal loss. A PCS system consists of magnet power supply (MPS) which energized current to a magnet, heater, a coated conductor tape for switching, and superconducting magnet. In this paper, the characteristic of thermal quench of the YBCO CC tape and BSCCO tape by heater trigger analyzed by FEM. And optimal length of heater is calculated by temperature and time analysis. This heater trigger analysis is expected to be a basic concept of PCS application design.

  • PDF

Effect of Bending Test Procedure on the Degradation Behavior of Critical Current in ReBCO Coated Conductor Tapes

  • Shin, H.S.;Dedicatoria, M.J.;Lee, N.J.;Oh, S.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권4호
    • /
    • pp.12-15
    • /
    • 2009
  • The $I_c$ degradation behavior of critical current in differently processed YBCO and SmBCO CC tapes with IBAD template has been investigated. It has been known that the residual strain in the CC tape will influence the shape of the $I_c$-strain window; $I_c$ may show a peak value if there exist a residual strain induced in the tape during manufacturing. The difference of residual strain may be resulted from the adopted different deposition techniques. In this study, bending test of CC tapes has been done using the Goldacker bending test rig which can produce both compressive and tensile bending strain continuously or alternately to the sample. For SmBCO CC tapes, in continuous compressive bending test, $I_c$ showed a minimal increase and did not degrade up to the largest strain that can be applied using the bending rig equivalent to 1.15% based on the sample thickness. However, in the case of alternate application of compressive and tensile bending strain, $I_c$ showed a larger degradation and a lower reversible limit when compared with the case of continuous application of the bending strain. When $I_c$ started to degrade significantly at the tension side, the reversibility ended, also at the compression side which is resulted from the permanent deformation like delamination or cracks that was induced due to tensile bending strain.

분리된 삼상자속구속형 전류제한기의 인덕턴스 변화에 따른 전류제한 특성 분석 (Analysis of Fault Current Limiting Characteristics According to Variation of Inductances in Separated Three-phase Flux-lock Type SFCL)

  • 두승규;두호익;김민주;박충렬;김용진;이동혁;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제22권6호
    • /
    • pp.522-525
    • /
    • 2009
  • We investigated the fault current characteristics of the separates three-phase flux-lock type superconducting fault current limiter(SFCL) according to the variation of inductances. The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core. And superconductor is series connected on secondary coil. Superconductor is using the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. To analyze the current limiting characteristics of a three-phase flux-lock type SFCL, the short circuit experiments were carried out fault such as the triple line-to-ground fault. The experimental result shows that fault current limiting characteristics of additive polarity winding was better than subtractive polarity winding and when the inductances of coil 2 was lower, resistances of YBCO CC was more generated.

Influence of bending strain on $I_c$ Degradation Behavior in YBCO Coated Conductor Tapes processed using RABiTS/MOD

  • Shin, Hyung-Seop;Dizon, John Ryan C.;Bonifacio, Rolly;Park, Jeong-Soo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권2호
    • /
    • pp.11-14
    • /
    • 2007
  • The critical current, $I_c$, degradation behaviors with bending strain were investigated in a commercially available YBCO coated conductor tape. In particular, the strain reversibility of $I_c$ and the influence of repeated bending on $I_c$ have been studied. Also, repeated bending at 77 K was done in order to understand the Ie behavior under cyclic bending strains. A reversible behavior of $I_c$ has been found up to a high bending strain of 1.60% for the RABiTS/MOD processed CC sample with copper reinforcement. Under repeated bending, the Ie showed a 95% $I_c$ retention up to 100 cycles for bending strains of 1.0% or less. The n-value behavior showed a good agreement with the $I_c$ degradation behavior, representing that any cracking did not occur on the YBCO film resulting from the reinforcement provided by the copper stabilizers.

SmBCO Coated Conductor의 교류손실 측정 (Measurement of AC Loss in SmBCO Coated Conductor)

  • 박명진;김우석;이지광;오상수;하홍수;김호섭;고락길;유상임;문승현;최경달
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.52-56
    • /
    • 2008
  • According to the improvement of HTS conductor, HTS tapes which have the high current capacity have been recently researched in several nations. For large power application, AC loss is the most important issue in the development of AC superconducting power devices because it is closely related to the system operation efficiency. In 1st generation wire of HTS conductor, BSCCO, AC loss is too large to use for power application. Also, It is well known in recently years that YBCO CC, the 2nd generation wire, has also too much AC loss to apply to AC power devices. There are many trials to develop the new HTS wire having the low AC loss around the world. In this research, we present the measurment result of magnetization losses in SmBCO coated conductors. We measured the magnetization loss generated by perpendicularly exposed external magnetic field and compared with the analytic value of the strip model. Also, we presented the results compared with measured magnetization loss of an YBCO coated conductor.

Influence of end-joint methods on magnetization loss in striated helical conductors

  • Kim, Woo-Seok;Kim, Yungil;Choi, Kyeongdal;Lee, Ji-Kwang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.39-43
    • /
    • 2013
  • To reduce the magnetization loss of a coated conductor, the striation and the transposition have to be accomplished for magnetic decoupling. The loss reduction effect in incomplete as well as complete striated YBCO CCs was reported in previous research. At the case of the incomplete striated sample, the end region of the sample is non-striated. So, it is not jointed with each other. In power applications, the joint is needed because current leads must be connected with HTS coils. In this research, the influence of end-joint methods with copper and superconducting joint on magnetization loss in striated YBCO CC and spiral winding samples are presented and compared with non-striated measured result.

분할형 YBCO CC 필라멘트 전류의 비접촉 측정 (Noncontact Current Measurement in Filaments of a Striated YBCO Coated Conductor)

  • 박상호;양귀상;변상범;김우석;이지광;박찬;최경달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.810-811
    • /
    • 2008
  • 현재 고온 초전도전력기기를 실용화하는데 교류손실이 문제가 되고 있다. 이러한 교류손실을 저감하기위해서 선재를 분할하는 방법에 대한 연구가 진행중이다. 분할된 초전도선재의 각 필라멘트의 전류분류가 일정하지 않을 경우 필라멘트의 임계전류 이상이 인가될 수 있다. 따라서 각 필라멘트에 흐르는 전류를 측정하여야 한다. 그러나 초전도선재의 필라멘트 각각의 전류를 측정하기는 어렵다. 본 연구에서는 초전도선재의 필라멘트의 각각의 전류를 비접촉 방식으로 측정할 수 있는 서치코일을 이용한 방법을 제안하였고 실험을 통해 이를 확인하였다.

  • PDF